Preview only show first 10 pages with watermark. For full document please download

Bk Th5220d1151 R 6

   EMBED


Share

Transcript

COMPOSITE WIRING DIAGRAM QW DEHUMIDIFICATION SERIES 2 230/208/60-1, REPRESENTS UNIT WITH CIRCUIT BREAKER KIT. 4101-100 A TB1 O1 Y Y1 C ATTACH TO TERM. C ON TB2 C H200 8403-058 TH5220D1151 3 BL 6 R 5 R E Y 4 HUM G O Y Y O/B BL AUX BR 230/208-60-1 240/220-50-1 PER NAMEPLATE OPTIONAL CS2000 ENERGY MONITOR (USE WITH "A" THERMOSTAT ONLY) 1 AREA OCCUPIED 2 HVAC PWR CB1 NO NC C NO NC C 3 L2 BK R 4 L1 5 GND 6 7 BK 8 O1 Y Y1 C 9 R Rc 10 R C BK "G" THERMOSTAT OPTION 5 4 11 3 2 1 IBM IBM 15 14 12 10 9 6 3 2 1 4102-033 C COMPONENT CODE L1 L2 O PR R BK BL Y BR BK G HUMIDISTAT 5 4 4 E E A1 O1 G G G Y Y1 Y W1 Y1 O/B B B AUX W2 W1 BL R R Y T O Y BL W2 BR R R R R C C C BK L L Rc BK R O H200 3 PL2 O 6 BL R 4 Y A1 T G O Y1 Y O B BL BR R R C BK 2 3 6 BL R 5 R E 4 HUM Y T G O Y Y O/B BL W2 BR C "F" THERMOSTAT OPTION TIMER R BK C L PK Y L1 L2 PK HPC CC T1 T2 BK R BL 4 R 6 R T1 7 240 CC R ALR Y C LPC LPC 5 BK 8 BK R C COM BK GND 9 LABELED WIRES CONNECT A B C D IF NO OPTIONS USED. 10 L 11 E1 RV 1 W 2 A1 3 W2 4 5 G 6 D 7 8 9 1 PR 2 RAT L E E1 BK TWV H Y0 A2 GND RAT Y Y 4102-031 B "E", "F", AND "G" ARE FACTORY WIRED THERMOSTAT OPTIONS R B R RLB C CRC R BL BL BK BR PR LC LI LO S Y R BK S O C RV TWV R BL BL BK BK TB5 REMOVE JUMPER WHEN LAC IS INSTALLED WIRING CODE FACTORY FIELD OPTIONAL STD. HIGH VOLTAGE LOW VOLTAGE ACCESSORY R QW-DA 4100C115 C BK TB4 T1 T2 MOVE RED WIRE TO 208V TAP FOR 208V OPERATION INSTALL JUMPER FOR HIGH SPEED F BLOWER OPER. ON MODELS 36, 42, 48, AND 60 Y 10 11 CIRCUIT BREAKER #1 CIRCUIT BREAKER #2 COMPRESSOR CONTACTOR COMPRESSOR CONTROL MODULE COMPRESSOR COMPRESSOR RUN CAPACITOR FUSE BLOCK GROUND HIGH PRESSURE CONTROL HEAT STRIP #1 HEAT STRIP #2 INDOOR BLOWER MOTOR LOW PRESSURE BYPASS LOW PRESSURE CONTROL OUTDOOR FAN MOTOR OUTDOOR MOTOR RELAY ACCESSORY PLUG #1 ACCESSORY PLUG #2 ACCESSORY PLUG #3 PRESSURE LOCKOUT INDICATOR PHASE MONITOR RETURN AIR TSTAT RELAY LOGIC BOARD REV. VALVE SOLINOID TRANSFORMER #1 TRANSFORMER #2 TERMINAL BLOCK #1 TERMINAL BLOCK #2 TERMINAL BLOCK #3 TERMINAL BLOCK #4 TERMINAL BLOCK #5 TERMINAL BLOCK #6 TERMINAL BLOCK #7 THREE WAY VALVE 208 Rc R R CCM BR 3 G1 H200 W2 PLI 4102-032 A 8403-058 B Y BK L "E" THERMOSTAT OPTION G2 F 1 Y W2 TH5220D1151 G TB2 R E HUM R BK BK Y BL Y BL BR R R BK PR 5 BK R PL1 1 2 3 Y BL 9 BR 10 11 12 4102-034 B IF93-380 PL3 1 2 3 BR BK R PR PK LOW VOLTAGE TERMINAL BLOCK "X" THERMOSTAT OPTIONS (FIELD WIRED) W1 1 2 3 4 5 6 7 8 UPPER CONTROL PANEL E 6 5 LOWER CONTROL PANEL 8403-058 TH5220D1151 6 BK Y RV C S R COMP HPC LPC TWV 4100-115 C CONDENSER SECTION 3 8403-049 IF93-380 CB1 CB2 CC CCM COMP CRC FB GND HPC HS1 HS2 IBM LPB LPC OFM OMR P1 P2 P3 PLI PM RAT RLB RV T1 T2 TB1 TB2 TB3 TB4 TB5 TB6 TB7 TWV COLOR CODE BK BL BR G GY O BLACK BLUE BROWN GREEN GRAY ORANGE PK PR R T Y PINK PURPLE RED TAN YELLOW