Preview only show first 10 pages with watermark. For full document please download

Bl6055 机芯使用说明书 (中文版)

   EMBED


Share

Transcript

1111 MOVEMENT INSTRUCTION EL MODE UP DOWN 1. FEATURES       Normal Time: Hour, Minuts, Second, Day and Weekday;12/24 hr format; Calendar ( Yr 2000-2099) 2-set alarm: Dailly alarn & hourly chime 1/100 Sencond Chronograph rangging form 0 to 59:59:99,with SPL function; Countdown funtcion, uo to 23hr.59min; Pedcometer mode. Smart shtp for 7 seconds Three types of pedometer: Total steps / time display mode→ Total steps / exerclse time display mode→ calories / mlleage display mode; User Information settings: metric / imperial→ weight→ G-Sensor sensitivity.in59sec,   50-day auto matic memory storage step function; Heart rate mode: Touch-on pulse measuring, showing dynamic heart rate 30-200 indicate whether the charging animation.   Whether the heart rate measurement mode 4 seconds EL backlight 2. FEATURE SELECTION 【MODE】:Change Function: Time Mode, Step Memory Mode,Heart Rate Mode. Press and hold 2 seconds to enter setting mode. Changing the setting tiems. 【DOWN】:Press reduce 1, press and hold for quickly adjust; Press and quickly on/offalarm; Press to turn on/pause stopwatch, countdown function; Press to downward check the history record. 【 UP 】:Press plus 1, press and hold for quickly adjust; Under Time mode,pressto change the following mode; AL1→ AL2→ Stopwatch→ coutdown; Total steps/ time display mode→ Total steps→ exerclse time display mode→ calies / mlleage display mode; Press and hold to lock/ unlock. 【 EL 】:Press to on EL light for 4 seconds;Press to no/off SPL function; Under pause the coutdown, press to the default value. 3. TIME/DATE SETTING  Press【 UP 】to switch the following mode:AL1→AL2→STOPWATCH→COUTDOWN, as shwn:   Press and hold 【MODE】2 seconds enter the time setting, 12/24 hour digit flashes; Press 【MODE】to switch settings items: 12/24hour format→hour→minute→second→year→month→day→hourly chime on/off→exit, as shown:  Press【DOWN】or【UP】key downward / upward adjust the setting items; press and hold【DOWN】or【UP】2 seconds to rapid adjust. Adjust year, month, day, weekday will updated automatically.  Under the time setting mode, no button operation for 30 4. ALARM  Under time mode, press【 UP 】to alarm mode.  Press【DOWN】to on /off alarm quickly ; the alarm icon dsiplay in all modes return on alarm.  Press and hold【MODE】2 seconds enter alarm setting, press【MODE】to switch the setting items: hour→minute,a As shows:  Press【UP】or【DOWN】downward/ upward adjust the settingitems, press and hold Press【UP】or【DOWN】 2seconds to rapid adjust. Alarm time is reached, the alarm icon flashes, 1 minute “BiBi” alarm reminder, press any key ti stop the alarm.  30 seconds without any key operation , auto-exit alarm setting mode,return to the time display mode.  In the alarm display mode, no button operatin, does not automatically return to time display mode. Note:enter the alarm setting mode, the alarm turn on automatically and display the alarm icon. 5. STOPWATCH  Press【UP】to switch stopwatch dome, the inittial value:00’00”00  Press【DOWN】to start/ stopstopwatch, press【EL】to zero when stop the time.  During the stopwatch timer, press 【EL】to turn on the SPL function, “SPL” will flash on the screen, stop watch running, Press【EL】again to return to the stopwatch timer.  Stopwatch reaching the maximum(59’59”99), thenon-alarm prompted to restart the stopwatch timer.  Stop the stopwatch, on buttin operation will not automatically return ti time display mode. NOTE:under turn on the SPL function, switch to other functions mode, automatically canceled SPL function, stopwatch to run continuely. 6. COUNTDOWN TIMER  Press【UP】to switch ti the countdown mode, the inittial value:00:00.00.  Press and hold【MODE】2 seconds to set the countdown timer, press【MODE】to switch setting tiems: hour→minute, As shown:  Press【UP】or【DOWN】downward/ upward adjust the setting value, press and hold【UP】or【DOWN】2 seconds to rapid adjust.  In the case of the countdown to 0 and can not start the countdown;countdown time, non-0, press【DOWN】key to start/stop the countdown.  Under pause the countdown, press【EL】to return to countdown settings.  Start countdown, the countdownicon will be blinking in all modes; stop the countdown, the countdown icon disappears.  When countdown reach to 00:00.00, the countdown icon disappears and 1 mibute “DiDi” alarm reminders, prees any key to stop the alarm.  When stop the alarm, display the countdown setting value.  When the alarm time and the countdown reaches the same time, the only rings countdown tips.  In the setting countdown, no button operation for 30 seconds, automatically exit setting and return the countdown mode.  In the countdown mode, no button operation, does not automatically return to time display mode.  NOTE: Enter the countdown setting, the countdown to zero automatically. 7. PEDOMETER MODE  Press【MODE】to switch to the pedometer mode, step number is displayed as 0.  Press【UP】to switch the display: Total steps/ time mode→Total steps/ exercise time mode→calories/ distance mode, As shown:  Total steps/ time mode : step and time display in the screen simultaneously, the steps display on the up LCD screen,the time display in the down LCD screen, Max step number :999999 Steps.  Total steps / exercise time mode: Total steps and exercise time display in the screen simultaneously, the steps display on the up LCD screen, the exercise time display on the down LCD screen, maximum steps:999999 steps/ 23 hours 59 minutes 59 seconds;  Calorie / distance moe: calories and mileage display on the screen simultaneously, the calorie display on the up LCD screen, the mileage display on the down LCD screen, maximum: 99999.9 kcal/ 9999.99KM or 9999.99 mile (calorie display with a Deccimal, mileage display with 2 decimal places).  In the step/ time mode or steps / exercise time mode, press and hold【MODE】key for 2 seconds to enter setup or check with the user information state,default: Metic setting item flashes.  Under the user information setting state, press【MODE】key to switch setting items: metric / imperril→weight→step distance→G-Sensor sensitivity, as shown:  Metric or imperial: The default to metric, press【UP】or【DOWN】key to switch the switch the selected metric / imperial. Adjustment of metric/ imperial; system setting items, the weight and step distance restore the default value automatically;  Setting weight: the default vaueis 60KG(132LB), adjustable range:30-200KG / 66-440LB;  Setting step distance: defaulf step distance is 70CM(28INCH), adjustable range:30-150CM/12-59INCH ;  Press【UP】or【DOWN】key up ward / downward adjust the setting items, press and hold【UP】or【DOWN】key for 2seconds to rapid adjust;  G-Sensor Sensitivity: default value: MIDDLE, the sensitivity level for choice: LOW→MIDDLE→HI.  In the step / time mode, press【EL】2 seconds, flashing display “ERASE”, you are prompted to zero; press【EL】 key to the steps number, calories, distancevalue is zero automatically, as shown:  In the pedometer mode, 30 minutes without any key operation, auto-return time display mode.  In the user information setting mode, on button operation for 30 seconds, automatically exit the setting mode.  In the steps to zero mdoe, 4 seconds without any key poeration, ro press any key (except the EL key), automatic exit the steps to zero mode, return to step display mode. NOTE: In the three types setp mode, all can count steps. 8. STEP MEMORY STORAGE MODE  press【MODE】key to switch to the step memory storage mode, the default value: 00;  The date of the historical recond display on the up LCD screen, the sreps, calores and distance of the historical recond on the down LCD screen with 2 second for the cycle of autonatic switching display(calories do not show decimal places, the mileage display 2 decimal places), as shown:  Press【UP】or【DOWN】key upward / downward to view the historical reconds.  Press and hold【EL】button for 2 seconds, the “ERASE” flashing display, you are prompted to clear all the reconded data; press【EL】key, auto clear recond of historical exercise, as shown:  In the state of the memory is cleared, on botton opearation for 4 seconds or press any key (except the EL key), automatic exit Clear History exercise recond sratus, return to step memory stored mode.  30 seconds without key opeartion, auto exit the step memory storage mode, return to the time display mode. 9. HEART RATE MODE  Press【MODE】key to enter heart rate mode, display “PULSE” the words and heart-shaped logo.  Heartbeat sugnai is detected, the heart-shaped signs began to beat, heart rate vaiue will display and  Under heart rate mode, if no heart rante is detected for 10 seconds, automatic returns to normal time mode. ATTENTION:  Both fingers have to cover the metal sensor as mush as possible. Exert pressure evenly. Under cold or dry weather, rub fingers before measuring pulse. REMARKS:  This device is not meant for medical purpose. Kindly consult your doctor if needed. Avoid using this device in strong static, sonic or electric affected environments. 10. MODE PROTECTION  In watch mode or pedometer mode, press【UP】key for 2 seconds to lock【MODE】button to switch to other modes, To prevent false triggering in the watch to the pedometer mode, resulting in power; To prevent the user noe exit form the pedometer mode, which leads to pedometer failed. NOTE: Open the lock function to display icon.