Preview only show first 10 pages with watermark. For full document please download

Bnc Cable To Connector List

   EMBED


Share

Transcript

Cable Jack Pin Crimp Hex Crimp Stripping & Panel in mm in mm Tool Belden Belden 1277R, 1278R, 1279R NBTC75BNN5 1.6 4.53  - -  Belden 1406B, 1407B, 1417B NBTC75BVV5 1.6 5.00 - - Belden 1426A, 1505A (ANH) NBNC75BLP9X NBNC75BLP9 NBNB75GLP9 1.07 1.6 6.47  - - Belden 1505F NBNC75BJP9X NBNC75BJP9 1.07 1.6 6.47  - - Belden 1506A NBNC75BIJ9 1.6 5.41  - - Belden 1520A, 1521A, 1522A, 179DT NBTC75BFI4 NBTB75CFI4 1.6 4.06  - - Belden 1694A (ANH) NBNC75BTU11X NBNC75BTU11 1.07 1.6 7.36  - -  NBNC75BTUP11X 1.07 7.06 - - Belden 1694F NBNC75BRU11 1.6 7.36  - - Belden 1695A NBNC75BQP11 1.6 6.47  - - Belden 1855A NBNC75BDD6X NBNC75BDD6 1.07 1.6 4.53  - - Belden 1865A NBTC75BXX6 1.6 5.00  - - Belden 1855ENH NBNC75BFG7X NBNC75BFG7 1.07 1.6 5.00  - - Belden 7731A (ANH) NBLC75BVZ17 1.8 10.00 - -  Belden 8218 NBTC75BXX5 1.6 5.00  - - Belden 8241 NBNC75BLP7X NBNC75BLP7 1.07 1.6 6.47  - - Belden 8241F NBNC75BLP9X NBNC75BLP9 NBNB75GLP9 1.07 1.6 6.47  - - Belden 8281 NBNC75BXY9 1.6 8.23  - - Belden 8281F NBNC75BYY9 1.6 8.23  - - Belden 9221 NBTC75BLI4 1.6 4.06  - - Belden 1794A NBNC75BZV14 1.6 8.23  - - Canare Canare L-3CFB, L-3C2VS NBNC75BHK7 1.6 5.41  - - Canare L-4CFB NBNC75BLP9X NBNC75BLP9 NBNB75GLP9 1.07 1.6 6.47  - - Canare L-4.5CHD, L-4.5CHWS NBNC75BTU11X NBNC75BTU11 1.07 1.6 7.36  - - Canare L-5CFB NBNC75BYY11 1.6 8.23  - - Canare LV-61S NBNC75BLP7X NBNC75BLP7 1.07 1.6 6.47  - - Canare LV-77S NBNC75BYY9 1.6 8.23  - - Canare V(3-5)-3C NBNC75BGG7 1.6 5.00  - - Canare V(3-5)-4CFB NBNC75BJJ9 1.6 5.41  - - Canare V(3-5)-5C NBNC75BRS9 1.6 7.01  - - Canare V(3-5)-5CFB NBNC75BWS11 1.6 7.01  - - Canare L-1.5C2VS NBTC75BLI4 1.6 4.06  - - Canare L-3CFW NBNC75BLP7X NBNC75BLP7 1.07 1.6 6.47  - - Canare L-5CFW NBNC75BYY11 1.6 8.23  - - Canford  Canford SDV-M NBTB75CNN5 1.6 4.53 - - Canford SDV, SDV-X, SDM NBNC75BFG7X NBNC75BFG7 1.07 1.6 5.00  - - Canford SDV-L, SDV-F NBNC75BWS11 1.6 7.01  - - Canford SDV-HD NBLC75BVZ17 1.8 10.00 - -  Canford SDV-F-HD NBNC75BWU13 1.6 7.36  - - Canford VCS (BBC PSF1/3) NBNC75BLS7 1.6 7.01  - - Clark Clark CD7559-0, CD7559F-0 NBNC75BLP9X NBNC75BLP9 1.07 1.6 6.47  - - Clark CD7523-7 NBNC75BDD6X NBNC75BDD6 1.07 1.6 4.53  - - Clark CD7506-0 NBNC75BTU11X NBNC75BTU11 1.07 1.6 7.36  - - Clark CD7506F-0 NBNC75BRU11 1.6 7.36  - - Commscope Commscope 2065V NBNC75BIJ9 1.6 5.41  - - Commscope 2279V NBNC75BQP11 1.6 6.47  - - Commscope 5563 NBNC75BLP7X NBNC75BLP7 1.07 1.6 6.47  - - Commscope 5565 NBNC75BLP9X NBNC75BLP9 NBNB75GLP9 1.07 1.6 6.47  - - Commscope 5765 NBNC75BTU11X NBNC75BTU11 1.07 1.6 7.36  - - Commscope 7536 (03-05) NBTC75BXX6 1.6 5.00  - - Commscope 7538 NBNC75BDD6X NBNC75BDD6 1.07 1.6 4.53  - - 126 setting standards + CS-BNC-TCI rearTWIST HD Tiny CS-BNC-LCV rearTWIST HD G u i d e CS-BNC-LCS rearTWIST UHD C o n n e c t o r UHD t o CS-BNC-RT C a b l e HD           - Cable Jack Pin Crimp Hex Crimp Stripping & Panel in mm in mm Tool Draka Multimedia Cable 0.31 / 1.45 AF, 753-1304(2), 755-1302 NBTC75BFI4 NBTB75CFI4 0.41 / 1.9 AF, 753-1104, 755-1103, 755-1101 NBTC75BNN5 NBTB75CNN5 0.51 / 2.3 Dz, 757-1001, VADN 7243 NBTC75BVX6 0.6 / 2.8 AF, 0.6 L / 2.8 AF NBNC75BFG7X NBNC75BFG7 1.07 HD Pro 0.6/2.8 AF NBNC75BFG7X NBNC75BFG7 1.07 0.6 / 3.7, 0.6L / 3.7 NBNC75BLP7X NBNC75BLP7 1.07 0.6 / 3.7 Dz NBNC75BLS7 0.8 / 3.7 AF, 755-801(803, 804) NBNC75BLP9X NBNC75BLP9 NBNB75GLP9 1.07 Highflex 08L/3.7D, HD Pro 0.8/3.7 AF NBNC75BLP9X NBNC75BLP9 1.07 0.8 / 4.9 Dz NBNC75BXY9 1.0 / 4.8 AF, 755-901/5 NBNC75BUU11X NBNC75BUU11 NBNB75GUU11 1.07 1.2L / 4.8Dz, 1.2L / 4.95AF NBNC75BWU13 1.4 / 6.6 AF NBLC75BSX14 1.6 / 7.3AF NBLC75BVZ17 Suhner Suhner G02233 NBTC75BFI4 NBTB75CFI4 Suhner G04233D NBNC75BLS7 Suhner S02223 NBTC75BLI4 Suhner S04233, S04263 NBNC75BLP9X NBNC75BLP9 NBNB75GLP9 1.07 Suhner S05133-07 NBNC75BTU11X NBNC75BTU11 1.07 Suhner S05163-02 NBNC75BTU11X NBNC75BTU11 1.07 Percon Percon VK2 NBTC75BNN5 Percon VK5 NBNC75BFG7X NBNC75BFG7 1.07 Percon VK6 NBNC75BLP9X NBNC75BLP9 1.07 Percon VK7 NBNC75BUU11X NBNC75BUU11 1.07 Percon VK77 NBNC75BTU11X NBNC75BTU11 1.07 Percon VK770F NBNC75BWU13 Percon VK8 NBLC75BSX14 Percon VK9 NBLC75BVZ17 Percon VK95 NBNC75BLP7X NBNC75BLP7 1.07 Van Damme Van Damme 268-175-000 NBNC75BUU11X NBNC75BUU11 1.07 Van Damme 268-275-000 NBNC75BJP9X NBNC75BJP9 1.07 Van Damme 268-306-000 NBNC75BLP9X NBNC75BLP9 1.07 Van Damme 268-408-000 NBTC75BFI14 Van Damme 268-475-000 NBNC75BTU11X NBNC75BTU11 1.07 Van Damme 268-675-000 NBNC75BTU11X NBNC75BTU11 1.07 Van Damme 278-475-000 NBLC75BVZ17 Van Damme 278-175-000 NBNC75BUU11X NBNC75BUU11 1.07 Van Damme 278-975-000 NBNC75BLP9X NBNC75BLP9 1.07 Van Damme 278-775-000 NBTC75BSS5 Van Damme 278-075-000 NBNC75BFG7X NBNC75BFG7 1.07 Van Damme 278-075-006 NBNC75BFG7X NBNC75BFG7 1.07 Van Damme 278-375-000 NBNC75BUU11X NBNC75BUU11 1.07 + CS-BNC-TCI rearTWIST HD Tiny CS-BNC-LCV rearTWIST HD G u i d e CS-BNC-LCS rearTWIST UHD C o n n e c t o r UHD t o CS-BNC-RT C a b l e  - -  1.6 4.53  1.6 5.00  1.6 5.00  1.6 5.00  1.6 6.47  1.6 7.01  1.6 6.47  1.6 6.47  1.6 8.23  1.6 7.36  1.6 7.36  1.75 9.73 - 1.8 10.00 - - - - - - - - - - - -   - - - - - - - - - - - - -  - - - - - - - - - - - - - - - - - - -  - - - - - -  - - HD 1.6 4.06 1.6 1.6 1.6 1.6 1.6 1.6 4.06 7.01 4.06 6.47 7.36 7.36  1.6 1.6 1.6 1.6 1.6 1.6 1.75 1.8 1.6 4.53 5.00 6.47 7.36 7.36 7.36 9.73 10.0 6.47  1.6 1.6 1.6 1.6 1.6 1.6 1.8 1.6 1.6 1.6 1.6 1.6 1.6 7.36 6.47 6.47 6.47 7.36 7.36 10.00 7.36 6.47 4.53 5.00 5.00 7.36 www.neutrik.com           - -        -        - - - - - - - - - - - - - - - - - - - - -  - - - - - -    -   - 127 Cable Jack Pin Crimp Hex Crimp Stripping & Panel in mm in mm Tool Argosy Image Argosy Image 360 NBNC75BFG7X NBNC75BFG7 1.07 1.6 5.00  Argosy Image 720 NBNC75BLP9X NBNC75BLP9 1.07 1.6 6.47  Argosy Image 1000 NBNC75BTU11X NBNC75BUU11 NBNB75GUU11 1.07 1.6 7.36  CAE CAE MC75 NBTC75BLI5 NBTB75CLI5 1.6 4.06  CAE MC75.39 NBTC75BVX6 1.6 5.00  CAE KX6A NBNC75BLP7X NBNC75BLP7 1.07 1.6 6.47  CAE VCB75 NBNC75BNP9 1.6 6.47  CAE VCB 100 NBNC75BXU13 1.6 7.36  CAE HD1250FLEX NBNC75BXU13 1.6 7.01  CAE HD10460LSZH NBNC75BTS11 1.6 7.01  CAE HD0628LSZH NBNC75BFG7X NBNC75BFG7 1.07 1.6 5.00  CAE HD08370LSZH NBNC75BLP9X NBNC75BLP9 1.07 1.6 6.47  CAE HD16720LSZH NBLC75BVZ17 1.8 10.00 - Cordial Cordial CVI 3-7 NBNC75BFG7X NBNC75BFG7 1.07 1.6 4.53  Cordial CVI 06-28 NBNC75BFG7X NBNC75BFG7 1.07 1.6 5.00  Cordial CVI 06-28HD, CVI 06-28HD-FRNC NBNC75BFG7X NBNC75BFG7 1.07 1.6 5.00  Cordial CVI (CVM) 06-37 NBNC75BLP7X NBNC75BLP7 1.07 1.6 6.47  Cordial CVI 08-37 HD-FRNC NBNC75BNP9 1.6 6.47  Cordial CVI 10-48 HD NBNC75BUU11X NBNC75BUU11 1.07 1.6 7.36  Cordial CVI 10-48 HD-FRNC NBNC75BWS11 1.6 7.01  Cordial CVM 08-32 HD-FLEX NBNC75BIJ9 1.6 5.41  Cordial CVM 12-50 HD-FLEX NBNC75BWU13 1.6 7.36  Kabeltronik Kabeltronik HFV 1.0/4.8 AF-FRNC NBNC75BRU11 1.6 7.36  Kabeltronik HFV 0.6/2.8 AF-FRNC NBNC75BFG7X NBNC75BFG7 1.07 1.6 5.00  Kabeltronik MVP 5x 0.6/2.8 AF-FRNC NBNC75BFG7X NBNC75BFG7 1.07 1.6 5.00  KLOTZ KLOTZ V06/28, V062SH, VMXx75Y NBNC75BFG7X NBNC75BFG7 1.07 1.6 5.00  KLOTZ V06/37 NBNC75BLP7X NBNC75BLP7 1.07 1.6 6.47  KLOTZ V08/37H, VD083SH NBNC75BLP9X NBNC75BLP9 1.07 1.6 6.47  KLOTZ VD083LP 0.8L/3.7DZ NBNC75BJP9X NBNC75BJP9 1.07 1.6 6.47  KLOTZ V10/48, V10/48H NBNC75BTU11X NBNC75BUU11 NBNB75GUU11 1.07 1.6 7.36  KLOTZ V16/72 NBLC75BVZ17 1.8 10.00 - Nexans Nexans HF 75 0.6/2.9 02YS(ST)CH NBNC75BFG7X NBNC75BFG7 1.07 1.6 5.00  Nexans HF 75 1.6/7.2 02Y(ST)C(ST)H NBNC75BVZ17 1.8 10.00 - Nexans HF 75 0.6/3.7 2YCY NBNC75BLP7X NBNC75BLP7 1.07 1.6 6.47  Proel Proel HPC 805 NBNC75BLP7X NBNC75BLP7 1.07 1.6 6.47  Proel HPC 810 NBNC75BLP9X NBNC75BLP9 1.07 1.6 6.47  Proel HPC 820 NBNC75BFH6 1.6 5.00  RG RG11 NBLC75BVZ17 1.8 10.00 -  RG59B/U NBNC75BLP7X NBNC75BLP7 1.07 1.6 6.47 RG179B/U NBTC75BLI4 1.6 4.06  SOMMER SOMMER 600-0051 (M/L/S) NBNC75BLP7X NBNC75BLP7 1.07 1.6 6.47  SOMMER 600-0054 (M/L/S) NBNC75BLP7X NBNC75BLP7 1.07 1.6 6.47  SOMMER 600-0101M NBNC75BFG7X NBNC75BFG7 1.07 1.6 5.00  SOMMER 600-0104M NBNC75BFG7X NBNC75BFG7 1.07 1.6 5.00  SOMMER 600-162(F), Vctor 0.8/3.7 NBNC75BLP9X NBNC75BLP9 1.07 1.6 6.47  SOMMER 600-025* -03 (05) NBTC75BLI5 NBTB75CLI5 1.6 4.06  SOMMER 600-0701 NBTC75BLI5 NBTB75CLI5 1.6 4.06  SOMMER 600-020* -03 (05) NBTC75BLI5 NBTB75CLI5 1.6 4.06  SOMMER 600-0451 NBNC75BLP9X NBNC75BLP9 NBNB75GLP9 1.07 1.6 6.47  SOMMER 600-0751 NBTC75BVX6 1.6 5.00  Tesca Tesca Bengal NBTC75BNS4 1.6 4.53  Tesca Supra NBNC75BFG7X NBNC75BFG7 1.07 1.6 5.00  Tesca Massimo NBLC75BSX14 1.75 9.73 - Tesca Sphere NBLC75BVZ17 1.8 10.00 - Tesca Presto NBNC75BJP9 1.6 6.47  Tesca Prima NBNC75BTS11 1.6 7.01  Tesca Linea NBNC75BNP9 1.6 6.47  Tesca Vostok NBNC75BWS12 1.6 7.01  Tesca Dublo NBNC75BWS12 1.6 7.01  Others AT&T 735 NBTC75BSS5 1.6 4.53  COMM-TEC RGBHV NBTC75BSS5 1.6 4.53  BBC PSF 1/3* NBNC75BLS7 1.6 7.01  Bryant BD SD50 NBNC75BRS9 1.6 7.01  Bryant BD SD53F NBNC75BJP9X NBNC75BJP9 1.07 1.6 6.47  Bryant SD10F, SD11 NBNC75BTU11X NBNC75BTU11 1.07 1.6 7.36  Bryant SD50F NBNC75BLP9X NBNC75BLP9 1.07 1.6 6.47  COVID CVD 1300-1500 NBTC75BLI5 NBTB75CLI5 1.6 4.06  Eupen 705 CRT 5V-HS NBNC75BTS11 1.6 7.36  Extron BNC-5HR NBTC75BNN5 NBTB75CNN5 1.6 4.53  Extron BNC-5RC NBNC75BFG7X NBNC75BFG7 1.07 1.6 5.00  GEPCO VDM230 NBNC75BDD6X NBNC75BDD6 1.07 1.6 4.53  GEPCO VPM2000 NBNC75BLP9X NBNC75BLP9 NBNB75GLP9 1.07 1.6 6.47  GEPCO VSD2001 NBNC75BTU11X NBNC75BTU11 1.07 1.6 7.36  Helix 734 NBNC75BNP9 1.6 6.47  Helix 735 NBTC75BSS5 1.6 4.53  Hirschmann KOKA 712Cu NBNC75BTS9 1.6 6.47  Kansai 3C-5S NBNC75BFH6 1.6 5.00  Kelsey SD-1 NBNC75BFG7X NBNC75BFG7 1.07 1.6 5.00  Kelsey SD-1-LL NBNC75BWS11 1.6 7.01  KROSCHU (341 270, 341 280) NBTC75BLI4 1.6 4.06  Quadtronics CABPGHD70MW-500 NBNC75BFG7 1.07 1.6 5.00  Wisi MK 99A NBNC75BWS12 1.6 6.47  ZNK CM14B NBTC75BFI4 NBTB75CFI4 1.6 4.06  * Registered trademark of BBC 128 setting standards + CS-BNC-TCI rearTWIST HD Tiny CS-BNC-LCV rearTWIST HD G u i d e CS-BNC-LCS rearTWIST UHD C o n n e c t o r UHD t o CS-BNC-RT C a b l e HD - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  -  - - - - - - - -  - - - - - - - - - - - - - - - - -  -  - - - -  -  - - - - - -  -  -  - -  -  - - -  - - - - - - -  -  - - - - - -  - -  - - - - - -  - - - - -  - - -  - Cable O.D. Pin crimp mm mm (square) G u i d e Hex Crimp mm Stripping Tool + CS-BNC-TCI Inner Insulator Conductor C a b l e CS-BNC-RT t o CS-BNC-LCV C o n n e c t o r CS-BNC-LCS rearTWIST HD & UHD NBLC75BVZ17 NBLC75BSX14 NBNC75BDD6 NBNC75BDD6X NBNC75BFG7 NBNC75BFG7X NBNC75BFH6 NBNC75BGG7 NBNC75BHK7 NBNC75BIJ9 NBNC75BJJ9 NBNC75BJP9 NBNC75BJP9X NBNC75BLP7 NBNC75BLP7X NBNC75BLP9 NBNC75BLP9X NBNC75BLS7 NBNC75BNP9 NBNC75BQP11 NBNC75BRS9 NBNC75BTS9 NBNC75BTS11 NBNC75BTU11 NBNC75BTU11X NBNC75BTUP11X NBNC75BTU13 NBNC75BUU11 NBNC75BUU11X NBNC75BRU11 NBNC75BWS11 NBNC75BWS12 NBNC75BWU13 NBNC75BXU13 NBNC75BXY9 NBNC75BYY9 NBNC75BYY11 NBNC75BZV14 < < < < < < < < < < < < < < < < < < < < < < < < < < < < < < < < < < < < < < 1.7 1.4 0.6 0.6 0.7 0.7 0.6 0.7 0.7 0.9 0.9 0.9 0.9 0.7 0.7 0.9 0.9 0.7 0.9 1.1 0.9 0.9 1.1 1.1 1.1 1.1 1.3 1.1 1.1 1.1 1.1 1.2 1.4 1.4 0.9 0.9 1.1 1.4 < < < < < < < < < < < < < < < < < < < < < < < < < < < < < < < < < < < < < < 8.0 6.6 2.8 2.8 3.1 3.1 3.1 3.2 3.3 3.6 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 4.1 4.5 4.8 4.7 4.7 4.7 4.7 4.7 4.7 4.9 4.9 4.7 5.1 5.1 5.1 5.3 5.3 5.2 5.2 5.2 < 10.4 1.80 (Hex crimp) 10.00 - < 9.5 1.75 (Hex crimp) 9.73 - < 4.3  1.6 4.53 < 4.3  1.07 4.53 < 4.7  1.6 5.00 < 4.7  1.07 5.00 < 4.9  1.6 5.00 < 4.7  1.6 5.00 < 5.6  1.6 (or 1.75 Hex) 5.41 < 5.3 1.6  5.41 < 5.3 1.6  5.41 < 6.3 1.6  6.47 < 6.3 1.07  6.47 < 6.3 1.6  6.47 < 6.3 1.07  6.47 < 6.3 1.6  6.47 < 6.3 1.07  6.47 < 6.9 1.6  7.01 < 6.3 1.6  6.47 < 6.3 1.6  6.47 < 6.9 1.6  7.01 < 6.9 1.6  7.01 < 6.9 1.6  7.01 < 7.3 1.6  7.36 < 7.3 1.07  7.36 < 7.3 1.07  7.06 < 7.3 1.6  7.36 < 7.3 1.6  7.36 < 7.3 1.07  7.36 < 7.3 1.6  7.36 < 6.9 1.6  7.01 < 6.9 1.6  7.01 < 7.3 1.6  7.36 < 7.3 1.6  7.36 < 8.0 1.6  8.23 < 8.0 1.6  8.23 < 8.0 1.6  8.23 < 8.0 1.6 (or 1.75 Hex) 8.23  < < < < < < < < < < 0.4 0.4 0.5 0.5 0.4 0.5 0.5 0.6 0.5 0.6 < < < < < < < < < < 1.6 1.8 1.8 2.0 2.0 2.3 2.5 2.5 2.6 2.6 < < < < < < < < < < - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -   rearTWIST TINY NBTC75BFI4 NBTC75BLI4 NBTC75BLI5 NBTC75BNN5 NBTC75BNS4 NBTC75BSS5 NBTC75BVV5 NBTC75BVX6 NBTC75BXX5 NBTC75BXX6 2.9 1.6 2.9 1.6 2.9 1.6 3.1 1.6 3.5 1.6 3.4 1.6 3.8 1.6 4.0 1.6 4.0 1.6 4.0 1.6  4.06  4.06  4.06  4.53  4.53  4.53  5.00  5.00  5.00  5.00 - - - - - - - - - - - - - - - - - - - -           2.9 1.6 3.1 1.6 2.9 1.6 6.3 1.6 7.3 1.6 6.3 1.6 7.3 1.6  4.06  4.53  4.06  6.47  7.36  6.47  7.36 - - - - - - - - - - - - - -        C A B L E J A C K S ( T I N Y & PA N E L V E R S I O N ) NBTB75CFI4 NBTB75CNN5 NBTB75CLI5 NBNB75GLP9 NBNB75GUU11 NBNB75ILP9 NBNB75IUU11 < < < < < < < 0.4 0.5 0.5 0.9 1.1 0.9 1.1 < < < < < < < 1.6 2.0 1.8 3.8 4.9 3.8 4.9 < < < < < < < www.neutrik.com 129