Bob Rodgers Drive

   EMBED


Share

Transcript

GENERAL NOTES: 1. MOST EXISTING UNDERGROUND UTILITIES ARE NOT INDICATED. THE EXISTING UNDERGROUND UTILITIES INDICATED ARE SCHEMATIC ONLY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR JOBSITE LOCATING AND PROTECTING ALL EXISTING UNDERGROUND UTILITIES PRIOR TO TRENCHING OR BORING. 2. INFORMATION INCLUDED ON THIS DRAWING IS INTENDED TO INDICATE THE GENERAL CHARACTER AND EXTENT OF WORK REQUIRED. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. UG UG UG UG TO LIGHTING FIXTURE BEYOND A-7,9 BLDG E UG NOTES: TECH BUILDING BUILDING "E" REMOVE EXISTING LIGHT POLE AND CONCRETE FOUNDATION. REMOVE CONDUCTORS FROM UNDERGROUND CONDUIT TO NEAREST JUNCTION. ABANDON EXISTING CONDUIT BELOW GRADE. JOBSITE SURVEY DEMOLITION REQUIREMENTS. EXISTING POWER UTILITY DIP POLE UG EXISTING SPLICE BOX G E-U UG HE E-O PRESERVE CONTINUITY OF EXISTING CIRCUIT AFTER REMOVAL OF EXISTING LIGHT POLE. EXISTING LIGHT POLE SHALL REMAIN. APPROXIMATE ROUTE OF PRIMARY CABLES. JOBSITE LOCATE AND PROTECT DURING CONSTRUCTION. E-U G UG UG E-OHE UG EXISTING PAD MOUNTED TRANSFORMER G BLDG C E-U UG E-UG HE E-O EXISTING MAIN SWITCHBOARD "MDP" UG EXISTING PANEL "B" LIBRARY & CLASSROOM BUILDING "C" EXISTING PANEL "DPA" B-14 BLDG D B-16 BLDG D UG SRRGC BUILDING "D" UG ODGE BERMEA BUILDING "A" BOB R ADMINISTRATION BUILDING RS DR IVE SRRGC BUILDING "B" STRIDDE, CALLINS & ASSOCIATES INC. CONSULTING MECHANICAL * ENGINEERS ELECTRICAL (361) 883-9199 Fax (361) 883-9177 342 S. Navigation Blvd. Corpus Christi, TX 78405-3615 Registration # F-006328 GENERAL NOTES: 1. MOST EXISTING UNDERGROUND UTILITIES ARE NOT INDICATED. THE EXISTING UNDERGROUND UTILITIES INDICATED ARE SCHEMATIC ONLY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR JOBSITE LOCATING AND PROTECTING ALL EXISTING UNDERGROUND UTILITIES PRIOR TO TRENCHING OR BORING. 2. INFORMATION INCLUDED ON THIS DRAWING IS INTENDED TO INDICATE THE GENERAL CHARACTER AND EXTENT OF WORK REQUIRED. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. PANEL "HK" PANEL "LK" UG NEW LIBRARY & CLASSROOM ADDITION UG PANEL "LCA3" PANEL "LA2" PANEL "LA" UG PANEL "LCA2" PANEL "LCA" PANEL "HA" PANEL "LCA1" EXISTING PAD MOUNTED TRANSFORMER PANEL "LA1" NOTES: EXISTING LIGHT POLE AND FIXTURES TO REMAIN. TECH BUILDING BUILDING "E" PANEL "MDP" UG BORE BELOW EXISTING DRIVE AS REQUIRED TO INSTALL CONDUIT. PANEL "HDPA" E H E-O UG UG HE E-O E-UG EXISTING SPLICE BOX METER #10 E-U G NEW PAD MOUNTED TRANSFORMER UG TUNNEL BELOW EXISTING CONCRETE FLATWORK AS REQUIRED TO INSTALL CONDUIT. IN-GRADE BOX SHALL BE QUAZITE CAT. NO. PG1324BA18 WITH PG1324HA17. TOP OF BOX SHALL BE 1" ABOVE FINISHED GRADE. PROVIDE 12" DEEP SAND BED BELOW BOX. BOX SHALL BE FOR PULLTHROUGH ONLY. SPLICES IN BOX WILL NOT BE PERMITTED. TWO (2) - #1, #6 GRND., 1 1/4"C. HA-13,15 TWO (2) - #8, #10 GRND., 1"C. #10 G E-U 30A., 250V., 2P, NF, NEMA-3R DISCONNECT SWITCH. MOUNT TO SIGN/ MARQUEE BASE AS REQUIRED. COORDINATE LOCATION WITH SIGN VENDOR. E-U G UG E-OHE #10 UG EXISTING MAIN MAIN SWITCHBOARD "MDP" PROVIDE GROUND ROD, GROUNDING CONDUCTOR, AND REQUIRED GROUNDING / BONDING FOR SIGN / MARQUEE. REFER TO POWER RISER DIAGRAM ON SHEET E3-2 FOR REQUIREMENTS. ROUTE CONDUIT BELOW EXISTING CONCRETE FLATWORK AND TRANSFORMER FOUNDATION AS REQUIRED TO INSTALL CONDUIT INTO PRIMARY COMPARTMENT OF EXISTING PAD MOUNTED TRANSFORMER. EXISTING PANEL "A" MAIN SHUNT-TRIP PUSHBUTTON. REFER TO POWER RISER DIAGRAM 2/E3-2 FOR REQUIREMENTS. EXISTING PANEL "B" THREE (3) - 2" CONDUIT WITH PULLCORD. STUB CONDUIT TO 2'-0" ABOVE FINISHED FLOOR. COORDINATE LOCATION WITH OWNER. NEW PANEL "DPA" TO REPLACE EXISTING LIBRARY & CLASSROOM BUILDING "C" ROUTE CONDUIT UP FROM BELOW GRADE EXPOSED ON EXTERIOR WALL. EXTEND CONDUIT UP TO ABOVE ACCESSIBLE CEILING AND ROUTE THROUGH EXISTING WALL VIA "LB" CONDUIT BODY. STUB CONDUIT TO 2'-0" BEYOND EXTERIOR WALL INSIDE EXISTING BUILDING. SRRGC BUILDING "D" TWO (2) - #4, #8 GRND., 1" C ROUTE CONDUIT UP FROM BELOW GRADE EXPOSED ON EXTERIOR WALL. EXTEND CONDUIT UP TO LEVEL OF PANEL "DPA" AND ROUTE THROUGH EXISTING WALL VIA "LB" CONDUIT BODY. EXTEND TO PANEL "DPA". JOBSITE VERIFY REQUIREMENTS. NEW PANEL "C" DPA-31 SRRGC BUILDING "B" BERMEA BUILDING "A" ODGE C-13,15 C-9,11 BOB R ADMINISTRATION BUILDING RS DR IV E NEW ADDITION SRRGC BUILDING "D" UG UG C-9,11 C-13,15 UG UG UG DPA-31 UG UG UG UG C-13,15 UG C-9,11 DPA-31 NEW SIGN / MARQUEE UG #10 #10 UG UG UG #10 UG #10 UG #10 UG STRIDDE, CALLINS & ASSOCIATES INC. CONSULTING MECHANICAL * ENGINEERS ELECTRICAL (361) 883-9199 Fax (361) 883-9177 342 S. Navigation Blvd. Corpus Christi, TX 78405-3615 Registration # F-006328 PANEL "HK" PANEL "LK" CANTEEN 100 HK-1 LK-60 LK-59 101A JAN. 104 CLASSROOM 108 STOR. 101B MEN 105 KITCHEN 101 101C STOR. 102 WOMEN 106 HALL 107 (1) D. 103 HA-9 #10 DL CLASSROOM 169 HALL 109 STOR. 159 PREP. 158 HALL 124 OFFICE 119 OFFICE 120 PHYSICS CLASSROOM 157 DL CLASSROOM 168 HALL 125 LIBRARY 110 MULTIPURPOSE 161 COMPUTER 118 STORAGE 117 WORK 116 D.L. CLASSROOM 121 SEMINAR ROOM 115 MEN 163 HA-4 HA-6 CLASSROOM 122 WOMEN 162 PANEL "HA" MECH. 166 STOR 164 HA-2 HALL 165 HA-7 JAN. 167 HALL 126 HA-8 SEMINAR ROOM 114 SEMINAR ROOM 113 HA-1,3,5 SEMINAR ROOM 123 SEMINAR ROOM 111 LIBRARY OFFICE 112 #10 #10 HALL 127 CLASSROOM 130 CLASSROOM 131 CLASSROOM 132 DL COMPUTER 133 GENERAL NOTES: 1. INFORMATION INCLUDED ON THIS DRAWING IS INTENDED TO INDICATE THE GENERAL CHARACTER AND EXTENT OF WORK REQUIRED. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. HA-9 #10 #10 #10 (1) #10 NOTES: CONNECT FIXTURES WITHIN SPACE TO PROVIDE DUAL SWITCHING VIA THE INSTALLED 50% TO 100% STEP DIMMING BALLAST UNLESS OTHERWISE INDICATED. SWITCH NEAREST STRIKE SIDE OF DOOR SHALL CONTROL 50% LEAD OF STEPPED BALLAST WITHIN FIXTURES. ALL LAMPS WITHIN FIXTURE SHALL BE CONTROLLED BY 100% SWITCH. CONNECT BALLAST AND EMERGENCY BATTERY PACK TO UNSWITCHED CONDUCTOR. ROUTE CONDUIT AND CONDUCTORS THROUGH LIGHTING CONTACTOR "CA" LOAD / POLE (INDICATED). DERIVE UNSWITCHED CONDUCTOR FOR EMERGENCY BALLAST IN FIXTURES TYPE "J1" AND "P1" FROM LINE SIDE OF LIGHTING CONTACTOR. TIME CLOCK "TC1" SHALL BE INTERMATIC CAT. NO. T174CR. CONNECT LOAD SIDE TO CONTACTOR "CA" CONTROL COIL. LIGHTING CONTACTOR "CA" SHALL BE SQUARE D, CLASS 8903, TYPE LG80VO4CPI. REFER TO SHEET E2-2 FOR CONTINUATION. CEILING FAN SHALL BE BIG ASS FAN HAIKU 60 CAT. NO. S3150-X2-20 WITH CLEAR LENS LED MODULE. COORDINATE FINISH COLOR WITH ARCHITECT / OWNER. REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR REQUIREMENTS. PROVIDE ALL ACCESSORIES FOR A COMPLETE INSTALLATION. BIG ASS FANS HAIKU 60 WIRELESS WALL CONTROL. CONTROL FANS AS INDICATED. REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR REQUIREMENTS. PROVIDE ALL ACCESSORIES FOR A COMPLETE INSTALLATION. STRIDDE, CALLINS & ASSOCIATES INC. CONSULTING MECHANICAL * ENGINEERS ELECTRICAL (361) 883-9199 Fax (361) 883-9177 342 S. Navigation Blvd. Corpus Christi, TX 78405-3615 Registration # F-006328 LIGHTING FIXTURE SCHEDULE FIXTURE TYPE ACRYLIC PRISMATIC RECESSED PROVIDE STEP DIMMING (50% TO 100%) BALLAST. LITHONIA CAT. NO. 2SP8 G 2 32 A12125 BSNP LP841 EL14 2-F32T8 FURNISHED 65[W] 41K MVOLT WHITE ENAMEL ACRYLIC PRISMATIC RECESSED PROVIDE STEP DIMMING (50% TO 100%) BALLAST. PROVIDE FACTORY INSTALLED BATTERY PACK. LITHONIA CAT. NO. SP8 G 1 32 A12125 GEB10PS LP841 1-F32T8 FURNISHED 35[W] 41K MVOLT WHITE ENAMEL ACRYLIC PRISMATIC RECESSED LITHONIA CAT. NO. SP8 G 1 32 A12125 GEB10PS LP841 EL 1-F32T8 FURNISHED 35[W] 41K MVOLT WHITE ENAMEL ACRYLIC PRISMATIC RECESSED LITHONIA CAT. NO. 2SP8 G 2 32 A12125 GEB10IS LP841 2-F32T8 FURNISHED 65[W] 41K MVOLT WHITE ENAMEL ACRYLIC PRISMATIC RECESSED LITHONIA CAT. NO. 2SP8 G 2 32 A12125 GEB10PS EL14 2-F32T8 FURNISHED 65[W] 41K MVOLT WHITE ENAMEL ACRYLIC PRISMATIC RECESSED LITHONIA CAT. NO. 2SP8 G 2 17 A12125 GEB10IS 2-F17T8 35[W] 41K MVOLT WHITE ENAMEL ACRYLIC PRISMATIC RECESSED D LITHONIA CAT. NO. 2SP8 G 2 17 A12125 GEB10IS EL14 2-F17T8 35[W] 41K MVOLT WHITE ENAMEL ACRYLIC PRISMATIC RECESSED PROVIDE FACTORY INSTALLED BATTERY PACK. D1 LITHONIA CAT. NO. ELM 2 LED L.E.D. FURNISHED NONE WHITE THERMOPLASTIC ARCYLIC SURFACE WALL PROVIDE FACTORY INSTALLED BATTERY PACK. REFER TO SPECIFICATIONS FOR MOUNTING REQUIREMENTS. LITHNOIA CAT. NO. ZL2 L48 4600 LP840 L.E.D. FURNISHED 75[W] 40K MVOLT WHITE ENAMEL MEDIUM DIFFUSE LENSE SURFACE COORDINATE LOCATION WITH STRUCTURE, DUCT, PIPING, ETC. LITHONIA CAT. NO. 2SP8 G 2 17 A12125 BSNP 2-F17T8 35[W] 41K MVOLT WHITE ENAMEL ACRYLIC PRISMATIC RECESSED PROVIDE STEP DIMMING (50% TO 100%) BALLAST. LITHONIA CAT. NO. 2ES8 P 2 32 BSNP L841HT8 2-F32T8 FURNISHED 65[W] 41K MVOLT WHITE ENAMEL WHITE ANGLED BLADES RECESSED PROVIDE STEP DIMMING (50% TO 100%) BALLAST. PROVIDE WITH 3100 LUMEN, LONG LIFE, 41K LAMPS. GOTHAM CAT. NO. EVO 41/22 8 AR L.E.D. FURNISHED 40[W] 41K NONE CRS SEMISPECULAR RECESSED GOTHAM CAT. NO. EVO 41/22 8 AR ELR L.E.D. FURNISHED 40[W] 41K NONE CRS SEMISPECULAR RECESSED PROVIDE FACTORY INSTALLED BATTERY PACK AND REMOTE MOUNTED TEST SWITCH. COORDINATE REMOTE TEST SWITCH LOCATION WITH OWNER. LITHONIA CAT. NO. 2SP8 G 3 32 A12125 GEB10IS LP841 LG 3-F32T8 FURNISHED 100[W] 41K MVOLT WHITE ENAMEL ACRYLIC PRISMATIC RECESSED PROVIDE DUAL BALLASTS TO ALLOW DUAL SWITCHING WITHIN SPACE. PROVIDE PREMIUM LENS GASKETING, INVERTED LENS, AND WHITE ALUMINUM DOOR FRAME. 3-F32T8 LITHONIA CAT. NO. 2SP8 G 3 32 A12125 GEB10IS LP841 LG FURNISHED 100[W] EL14 41K MVOLT WHITE ENAMEL ACRYLIC PRISMATIC RECESSED PROVIDE DUAL BALLASTS TO ALLOW DUAL SWITCHING WITHIN SPACE. PROVIDE PREMIUM LENS GASKETING, INVERTED LENS, AND WHITE ALUMINUM DOOR FRAME. PROVIDE FACTORY INSTALLED BATTERY PACK AND TEST SWITCH LITHONIA CAT. NO. 2SP8 G 3 17 A12125 GEB10IS LP841 LG 3-F17T8 FURNISHED 55[W] 41K MVOLT WHITE ENAMEL ACRYLIC PRISMATIC SURFACE PROVIDE DUAL BALLASTS TO ALLOW DUAL SWITCHING WITHIN SPACE. PROVIDE PREMIUM LENS GASKETING, INVERTED LENS, AND WHITE ALUMINUM DOOR FRAME. LITHONIA CAT. NO. DSXW1 LED 20C 530 50K T3M DDBXD L.E.D. FURNISHED 40[W] 50K MVOLT DIE-CAST ALUMINUM DARK BRONZE PRECISION MOLDED ACRYLIC SURFACE MOUNT AT 14'-6" ABOVE FINISHED FLOOR UNLESS OTHERWISE DIRECTED BY ARCHITECT. LITHONIA CAT. NO. DSXW1 LED 20C 530 50K T3M ELCW DDBXD L.E.D. FURNISHED 40[W] 50K MVOLT DIE-CAST ALUMINUM DARK BRONZE PRECISION MOLDED ACRYLIC SURFACE MOUNT AT 14-6" ABOVE FINISHED FLOOR UNLESS OTHERWISE DIRECTED BY ARCHITECT.PROVIDE FACTORY INSTALLED BATTERY PACK. MOUNT FIXTURE3 ABOVE DOOR AT ELEVATION SELECTED BY ARCHITECT. LITHONIA CAT. NO. DSX2 LED 80C 1000 50K T2M RPA PER DDBXD L.E.D. FURNISHED 275[W] 50K MVOLT DIE-CAST ALUMINUM DARK BONZE PRECISION MOLDED ACRYLIC POLE PROVIDE LITHONIA CAT. NO. RTA 30 8G FBC VD DDB POLE. COORDINATE FACTORY DRILL MOUNTING WITH FIXTURE QUANTITIES AS INDICATED. PROVIDE FACTORY WELDED STUD IN POLE SHAFT ADJACENT TO HAND HOLE FOR CONNECTION OF GROUNDING CONDUCTOR. PROVIDE FACTORY INSTALLED PHOTOELECTRIC CELL. XA LITHONIA CAT. NO. LE S 1R EL L.E.D. FURNISHED NONE BRUSHED ALUMINUM RED THERMOPLASTIC SURFACE PROVIDE FACTORY INSTALLED BATTERY PACK. PROVIDE MOUNTING HARDWARE FOR TOP, BACK, END MOUNTING. XB LITHONIA CAT. NO. LE S 2R EL L.E.D. FURNISHED NONE BRUSHED ALUMINUM RED THERMOPLASTIC SURFACE PROVIDE FACTORY INSTALLED BATTERY PACK. PROVIDE MOUNTING HARDWARE FOR TOP, END MOUNTING. B1 C C1 CLASSROOM 148 CLASSROOM 147 CLASSROOM 145 CLASSROOM 146 OFFICE 150 OFFICE 154 EM F G H OFFICE 149 OFFICE 153 HA-11 HALL 144 #10 #10 J J1 K HA-10 HALL 143 K1 OFFICE 142 OFFICE 138 M P HA-12 #10 (2) DL CLASSROOM 134 CLASSROOM 135 #10 CLASSROOM 136 #10 #10 GENERAL NOTES: 1. CLASSROOM 137 OFFICE 139 #10 STOR. 140 #10 REMARKS DIFFUSER WHITE ENAMEL B HALL 152 MOUNTING BODY MVOLT A1 OFFICE 151 FINISH 2-F32T8 FURNISHED 65[W] 41K FIRE 160 I.T. OFFICE 155 LAMPS LITHONIA CAT. NO. 2SP8 G 2 32 A12125 BSNP LP841 A I.T. 156 CATALOG REFERENCE BALLAST/ DRIVER VOLTAGE P1 OFFICE 141 R PROVIDE WITH FACTORY INSTALLED EMERGENCY BATTERY PACK AND TEST SWITCH. PROVIDE FACTORY INSTALLED BATTERY PACK. NOTES: INFORMATION INCLUDED ON THIS DRAWING IS INTENDED TO INDICATE THE GENERAL CHARACTER AND EXTENT OF WORK REQUIRED. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. CONNECT FIXTURES WITHIN SPACE TO PROVIDE DUAL SWITCHING VIA THE INSTALLED 50% TO 100% STEP DIMMING BALLAST UNLESS OTHERWISE INDICATED. SWITCH NEAREST STRIKE SIDE OF DOOR SHALL CONTROL 50% LEAD OF STEPPED BALLAST WITHIN FIXTURES. ALL LAMPS WITHIN FIXTURE SHALL BE CONTROLLED BY 100% SWITCH. CONNECT BALLAST AND EMERGENCY BATTERY PACK TO UNSWITCHED CONDUCTOR. REFER TO SHEET E2-1 FOR CONTINUATION. DERIVE UNSWITCHED CONDUCTOR FOR EMERGENCY BALLAST IN FIXTURES TYPE "J1" AND "P1" FROM LINE SIDE OF LIGHTING CONTACTOR. ROUTE CONDUIT AND CONDUCTORS THROUGH LIGHTING CONTACTOR "CA" LOAD / POLE (INDICATED). FROM LINE SIDE REFER TO SHEET E2-1 FOR LOCATION OF PANEL / LIGHTING CONTACTOR. N PHASE COLOR WHITE PP SW PHASE COLOR WITH WHITE SW TRACER N RED BLACK BLUE LOW VOLTAGE 3 CONDUCTOR CONTROL CABLE OCCUPANCY SENSOR AS SCHEDULED. O* POWER PACK AS SCHEDULED SWITCHING AS INDICATED ON FLOOR PLAN. PHASE COLOR WITH WHITE TRACER TO LIGHT FIXTURES BEYOND. OCCUPANCY SENSOR SCHEDULE MARK DESCRIPTION MANUFACTURER/ MODEL NO. OCCUPANCY SENSOR GENERAL NOTES : 1. OCCUPANCY SENSOR LOCATIONS INDICATED ON THE DRAWINGS ARE SCHEMATIC. 2. CEILING MOUNTED MOTION SENSORS IN TYPICAL INSTRUCTIONAL SPACES SHALL BE MOUNTED AS NEAR THE CENTER OF ROOM AS IS POSSIBLE. 3. ALL MOTION SENSORS (WHETHER WALL OR CEILING MOUNTED) SHALL BE INSTALLED OR MOUNTED TO A JUNCTION BOX. 4. ALL MOTION SENSORS SHALL BE MOUNTED AT LEAST 4'-0" AWAY FROM HVAC SUPPLY GRILLS. 5. ALL OCCUPANCY SENSOR TERMINATIONS SHALL BE MADE IN AN APPROVED JUNCTION BOX. STRIDDE, CALLINS & ASSOCIATES INC. CONSULTING MECHANICAL * ENGINEERS ELECTRICAL (361) 883-9199 Fax (361) 883-9177 342 S. Navigation Blvd. Corpus Christi, TX 78405-3615 Registration # F-006328 ENTRY PORCH 125 OFFICE 206 OFFICE 208 MECH. 207 B-6 B-2 OFFICE 106 C-3 OFFICE 105 OFFICE 104 C-5 C-7 PANEL "C" LARGE CLASSROOM 124 CORR. 204 MEDIUM CLASSROOM 111 SMALL CLASSROOM 110 STUDENT AREA 109 CONFERENCE 108 OFFICE 103 OFFICE 107 FILE STORAGE 122 WAIT/ SECR. 102 OFFICE 209 OFFICE 205 CLASSROOM 210 JAN. 123 CORRIDOR 200 EXISTING PANEL "B" C-1 CLASSROOM 202 FIBER OPTIC 115 WOMEN 112 LIBRARY 121 TELECONF. 116 MECH. 114 MEN 113 COMP. LAB 117 OBSERVATION 119 NEW PANEL "DPA" TO REPLACE EXISTING B-4 COMP. LAB 118 CLASSROOM 201 PRODUCTION ROOM 101 STORAGE 120 B-8 CLASSROOM 203 ENTRY PORCH 126 GENERAL NOTES: 1. INFORMATION INCLUDED ON THIS DRAWING IS INTENDED TO INDICATE THE GENERAL CHARACTER AND EXTENT OF WORK REQUIRED. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. NOTES: CONNECT FIXTURES WITHIN SPACE TO PROVIDE DUAL SWITCHING VIA THE INSTALLED 50% TO 100% STEP DIMMING BALLAST UNLESS OTHERWISE INDICATED. SWITCH NEAREST STRIKE SIDE OF DOOR SHALL CONTROL 50% LEAD OF STEPPED BALLAST WITHIN FIXTURES. ALL LAMPS WITHIN FIXTURE SHALL BE CONTROLLED BY 100% SWITCH. CONNECT BALLAST AND EMERGENCY BATTERY PACK TO UNSWITCHED CONDUCTOR. DERIVE UNSWITCHED CONDUCTOR FOR EMERGENCY BALLAST IN FIXTURES TYPE "J1" FROM LINE SIDE OF LIGHTING CONTACTOR / TIME CLOCK / PHOTOCELL. JOBSITE LOCATE SOURCE. EXISTING FIXTURE SHALL REMAIN. INSTALL ADDITIONAL UNSWITCHED CONDUCTOR IN EXISTING CONDUIT. JOBSITE SURVEY REQUIREMENTS. INTERCEPT EXISTING CONDUIT AND CONDUCTORS AT APPROXIMATE LOCATION INDICATED. EXTEND NEW CONDUIT AND CONDUCTORS TO NEW FIXTURES AS INDICATED. JOBSITE SURVEY REQUIREMENTS. EXISTING FIXTURE SHALL BE REMOVED. REMOVE CONDUCTORS BACK TO LAST EXISTING FIXTURE TO REMAIN UNLESS OTHERWISE INDICATED. CONTRACTOR SHALL REWORK EXISTING CONDUIT AND CONDUCTORS TO PRESERVE EXISTING CONTINUITY AS REQUIRED. JOBSITE SURVEY REQUIREMENTS. REPLACE EXISTING LIGHT FIXTURE WITH NEW FIXTURE AS INDICATED. JOBSITE SURVEY REQUIREMENTS. PRESERVE EXISTING CIRCUIT CONTINUITY DURING FIXTURE REPLACEMENT. INSTALL NEW FIXTURE AT ELEVATION OF EXISTING BUILDING MOUNTED LIGHT FIXTURES. JOBSITE SURVEY ELEVATION. PROVIDE FIRE RATED ENCLOSURE FOR FIXTURE INDICATED. STRIDDE, CALLINS & ASSOCIATES INC. CONSULTING MECHANICAL * ENGINEERS ELECTRICAL (361) 883-9199 Fax (361) 883-9177 342 S. Navigation Blvd. Corpus Christi, TX 78405-3615 Registration # F-006328 NOTE: ALL WIRING DEVICES AND DISCONNECT SWITCHES SERVING KITCHEN 1. NOTES: EQUIPMENT SHALL BE INSTALLED AT LOCATIONS / ELEVATIONS COORDINATED WITH APPROVED KITCHEN EQUIPMENT SUBMITTALS / SHOP DRAWINGS. GENERAL NOTES: INFORMATION INCLUDED ON THIS DRAWING IS INTENDED TO INDICATE THE GENERAL CHARACTER AND EXTENT OF WORK REQUIRED. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. TV BOX 2" CONDUIT CAMERA BOX MOUNT 2" ABOVE COUNTER OR SPLASH. 2" CONDUIT TO ABOVE ACCESSIBLE CEILING PANEL "LK" ACF-1 4" 4" 4"W x 4"H x 4"D NEMA-1 BOX WITH COVER. PROVIDE 2" CLOSE NIPPLE IN COVER. 6'-5" INSTALL OUTLET BOX FLUSH IN SUSPENDED CEILING. COORDINATE LOCATION WITH ARCHITECT. PANEL "HK" CORNER WALL 3' FURNISH AND INSTALL FLUSH MOUNTED JUNCTION BOX FOR CCTV CAMERA BY OWNER. REFER TO TELEVISION / CAMERA DETAIL 3/E3-1 FOR REQUIREMENTS. PROVIDE A TOTAL OF TWO (2) - 2-GANG BOXES WITH TWO (2) - 2" CONDUIT FROM EACH BOX TO ABOVE ACCESSIBLE CEILING. STOR. 101B LK-54 LK-1,3 REFER TO TELEVISION / CAMERA DETAIL 3/E3-1 FOR REQUIREMENTS. LK-7,9,11 TRANSFORMER "TXLK" (SUSPENDED) 101A LK-51 JAN. 104 INSTALL OUTLET BOXES FLUSH IN CASEWORK / MILLWORK. REFER TO ARCHITECTURAL DETAILS FOR REQUIREMENTS. MEN 105 LK-11 ONE (1) - 2-GANG BOX WITH TWO (2) - 1" CONDUIT FROM BOX TO ABOVE ACCESSIBLE CEILING. LK-53 C LK-13 COORDINATE ROUGH-IN REQUIREMENTS WITH PLUMBING CONTRACTOR. 2'-10" ONE (1) - 1" CONDUIT WITH PULLCORD. ROUTE CONDUIT FROM DEMONSTRATION DESK / CASEWORK / FLOOR BOX IN SLAB TO WALL INDICATED. ROUTE CONDUIT UP CONCEALED IN WALL TO ABOVE ACCESSIBLE CEILING. FCU LK-61 I.M. C LK-10 LK-8 C C C FCU ROUTE CONDUIT AND CONDUCTORS IN SLAB TO WALL INDICATED. ROUTE CONDUIT AND CONDUCTORS UP CONCEALED IN WALL TO ABOVE ACCESSIBLE CEILING. LK-12,14,16 LK-18,20 FLOOR 101C 1'-6" COORDINATE RECEPTACLE LOCATION FOR RECESSED MOUNTED CHILLER WITH PLUMBING CONTRACTOR. PROVIDE #12 / 2 SJO PORTABLE CORD AND CORD CAP FOR RECESSED CHILLER. COORDINATE REQUIREMENTS WITH PLUMBING CONTRACTOR. #10 LK-15,17,19 UG LK-21,23 (S.T.) LK-48,50,52 #10 FREEZER COOLER LK-22,24,26 (S.T.) KEF-1 LK-30,32,34 (S.T.) KITCHEN 101 ROUTE FLEXIBLE METAL CONDUIT CONCEALED IN CASEWORK / MILLWORK. COORDINATE ROUTING WITHIN CASEWORK / MILLWORK WITH CASEWORK / MILLWORK VENDOR / INSTALLER. REFRIGERATION RACK / CONDENSING UNIT ON ROOF. TWO (2) - 1" CONDUIT WITH PULLCORD. ROUTE CONDUIT FROM CASEWORK / MILLWORK IN SLAB TO WALL INDICATED. ROUTE CONDUIT UP CONCEALED IN WALL TO ABOVE ACCESSIBLE CEILING. STOR. 102 DAISY CHAIN A MAXIMUM THREE (3) - DATA OUTLETS TOGETHER WITHIN CASEWORK / MILLWORK INDICATED. PROVIDE 1" FLEXIBLE METAL CONDUIT BETWEEN DAISY CHAINED DATA OUTLETS. COORDINATE ROUTING WITHIN CASEWORK / MILLWORK WITH CASEWORK / MILLWORK VENDOR / INSTALLER. LK-27,29,31 (S.T.) HALL 107 LK-38 (S.T.) PROVIDE POWER AND CONTROL CONNECTIONS AS REQUIRED FOR MOTORIZED PROJECTION SCREEN. COORDINATE LOCATION AND REQUIREMENTS WITH ARCHITECT / MOTORIZED PROJECTION SCREEN VENDOR. 3-#3, #8 GRND., 1 1/4"C. PANEL "HK" PANEL "LK" TRANSFORMER "TXLK" SUSPENDED STOR. 101B LK-42 FLUSH MOUNTED OUTLET BOX FOR MOTORIZED PROJECTION SCREEN CONTROL DEVICE. CONTROL DEVICE SHALL BE FURNISHED BY MOTORIZED PROJECTION SCREEN VENDOR. ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT, CONDUCTORS, TERMINATIONS, AND INSTALLATION OF VENDOR FURNISHED CONTROLLER. COORDINATE LOCATION AND REQUIREMENTS WITH ARCHITECT / VENDOR. WOMEN 106 LK-43,45,47 (S.T.) JAN. 104 101A LK-35,37,39 (S.T.) LK-44 (S.T.) SWITCH FURNISHED INTEGRAL TO KITCHEN HOOD CONTROL PANEL. D. 103 MEN 105 PROVIDE POWER AND CONTROL CONNECTIONS TO AIR CURTAIN FAN / DOOR SWITCH FURNISHED BY KITCHEN EQUIPMENT VENDOR. LK55,57 CANTEEN 100 REFER TO ENLARGED PARTIAL POWER PLAN 2/E3-1 FOR REQUIREMENTS WITHIN AREA INDICATED. 101C 30A., 250V., 3P., NF, NEMA-4X STAINLESS STEEL DISCONNECT SWITCH. MOUNT SWITCH BELOW POT WASH SINK COUNTER. KEF-1 STOR. 102 PROVIDE LINE CONNECTIONS AT JUNCTION BOX FURNISHED WITH REFRIGERATION EQUIPMENT. WOMEN 106 LIGHT SWITCH FURNISHED WITH COOLER / FREEZER. HALL 107 D. 103 KITCHEN 101 30A., 250V., 2P., NF, NEMA-4X STAINLESS STEEL DISCONNECT SWITCH. MOUNT SWITCH ABOVE AIR CURTAIN FAN. CLASSROOM 108 PROVIDE CONNECTION TO FIXTURE / DEVICE FURNISHED WITH COOLER / FREEZER AT NOTE NO. 21. LCA1-1 LCA1-3,5 HALL 124 EF-2 DF-1 LA1-22 LA1-16 HALL 109 MANUAL MOTOR STARTER FOR USE AS SERVICE DISCONNECT SWITCH SHALL BE SQUARE D CLASS 2510, TYPE FW1P. LA1-1,3,5 ALL CONDUIT PENETRATIONS THROUGH COOLER / FREEZER PANELS SHALL HAVE SEAL FITTINGS WITH SEALANT. SEAL ALL PENETRATIONS. LA1-23 LCA-13 LCA1-35,37,39 FURNISH AND INSTALL ALL CONTROL INTERLOCK WIRING TO REFRIGERATION RACK / CONDENSING UNIT ON ROOF AS REQUIRED BY CONTROL WIRING DIAGRAMS FURNISHED BY REFRIGERATION EQUIPMENT VENDOR. LCA-25,27 LA-40 PREP. 158 LCA1-45 LA1-21 STOR. 159 LCA-55 OFFICE 119 LCA1-42 LCA1-13 D.L. CLASSROOM 169 LA1-19 LCA1-22 LCA1-28 LCA1-30 OFFICE 120 MANUAL MOTOR STARTER FOR USE A SERVICE DISCONNECT SHALL BE SQUARE D CLASS 2510, TYPE FW2P. MULTIPURPOSE 161 LCA1-32 ROUTE CONTROL AND INTERLOCK WIRING TO COOLER / FREEZER / "FCU" UNIT AS REQUIRED. LCA-29 MOUNT DEVICE AS REQUIRED TO REGISTER TABLE. COORDINATE REQUIREMENTS WITH ARCHITECT / KITCHEN CONSULTANT. LCA-55 LCA1-40 LCA-26,28 TYPICAL LCA-47 D.L. CLASSROOM 168 LCA1-2 LCA1-48 WORK 116 TYPICAL LCA1-7 LCA1-11 STOR. LCA1-9 117 LCA1-38 LCA1-49 TRANSFORMER "TXLCA" LCA1-19,21 LA-21,23 LCA-30 JAN. 167 SEMINAR ROOM 115 LCA1-55, 57,59 STOR 164 TRANSFORMER "TXLA" LCA1-4 TYPICAL HOOD CONTROL PANEL FURNISHED BY KITCHEN EQUIPMENT VENDOR AND INSTALLED BY ELECTRICAL CONTRACTOR. LA-7,9,11 TYPICAL LA19,11 TERMINATE AT LOAD SIDE POLE OF NORMALLY OPEN CONTACT IN FIRE SUPPRESSION PANEL. PROVIDE PARALLEL CONNECTION TO SHUNT TRIP CIRCUIT BREAKER CONTROL COILS AT PANEL "LK". REFER TO HOOD VENDOR FURNISHED WIRING DIAGRAMS. LA-19 LA1-26 LCA1LA1-12,14 24,26 LA113,15 PROVIDE POWER CONNECTION TO FIRE SUPPRESSION PANEL FURNISHED AND INSTALLED BY THE FIRE SUPPRESSION CONTRACTOR. COORDINATE LOCATION WITH FIRE SUPPRESSION CONTRACTOR. LCA-49 LCA-53 D.L. CLASSROOM 121 PANEL "LA1" LIBRARY 110 TYPICAL LA1-6,8,10 4 - #3, #8 GRND., 1 1/4" CONDUIT. PROVIDE LINE SIDE CONNECTION TO LOAD CENTER FURNISHED WITH SERVING UNIT. LA-37 LCA1-50 LA1-2,4 1" CONDUIT WITH PULLCORD ROUTED IN SLAB TO COMPUTER IN KITCHEN OFFICE. TERMINATE AT COMMUNICATION OUTLET IN KITCHEN OFFICE. PHYSICS 157 LCA1-6,8 LA1-25 PANEL "LCA1" LA-22,24 LA-20 LCA1-41 TYPICAL PROVIDE #12/2 WITH GROUND SJO CORD AND CORD CAP. TERMINATE AT ICE MACHINE AS REQUIRED. LCA-51 HALL 125 COMPUTER 118 COORDINATE LOCATION OF REFRIGERATION RACK / CONDENSING UNIT WITH ARCHITECT / EQUIPMENT VENDOR. LA-38 HALL 165 PANEL "LCA" PANEL "LA" LA-8,10 TYPICAL MECH. 166 WOMEN 162 MEN 163 PROVIDE 120 VOLT CONNECTION AS REQUIRED AT JUNCTION BOX FURNISHED WITH HOOD FOR LIGHTING FIXTURES. LCA-43 3 - #8, #8 GRND., 1 1/4" CONDUIT. LA-12,14,16 3 - #4, #8 GRND., 1 1/4" CONDUIT. PANEL "HA" PANEL "HDPA" LCA-28 LA-25,27 LCA-18 LCA-26 PROVIDE OCTAGON BOX IN WALL AT 48" ABOVE FINISHED FLOOR. ROUTE A 1/2" CONDUIT WITH PULLCORD TO FIRE SUPPRESSION PANEL. COORDINATE ROUTE WITH FIRE SUPPRESSION CONTRACTOR. PROVIDE LINE SIDE CONNECTION TO LOAD CENTER FURNISHED WITH SERVING UNIT. LCA1-47 SEMINAR ROOM 114 TYPICAL 30A., 250V., 3P., NF, NEMA-3R DISCONNECT SWITCH. MOUNT SWITCH ABOVE ROOF. PROVIDE SWITCH SUPPORT IN ACCORDANCE WITH ROOFING CONTRACTOR REQUIREMENTS. DF-1 CLASSROOM 122 PANEL "MDP" HALL 126 LCA-48,50 LA-13,15,17 LCA-45 LCA-42 LCA-44,46 LCA-56,58 LCA-52,54 PROVIDE LINE AND LOAD SIDE TERMINATIONS AT DISPOSAL CONTROL PANEL AS REQUIRED. COORDINATE REQUIREMENTS WITH KITCHEN EQUIPMENT VENDOR FURNISHED DRAWINGS. LIBRARY OFFICE 112 SEMINAR ROOM 111 LCA1-58 SEMINAR ROOM 113 LA1-18,20 PROVIDE POWER CONNECTION TO SECURITY GATE AS REQUIRED. COORDINATE REQUIREMENTS WITH ARCHITECT / OWNER. LA1-17 LCA-33,35 LCA1-15 LCA-31 CLASSROOM 123 METER MAIN SHUNT-TRIP PUSHBUTTON. REFER TO POWER RISER DIAGRAM 2/E3-2 FOR REQUIREMENTS. 100A., 250V., 3P., NF, NEMA-4X STAINLESS STEEL DISCONNECT SWITCH. LCA-34,36 LCA-32 LCA-37,39 FLOOR BOX SHALL BE HUBBELL CAT. NO. HBLCFB401CB WITH HUBBELL CAT. NO. HBLTCGNTSW COVER FLANGE ASSEMBLY. PROVIDE TWO (2) - HUBBELL CAT. NO. HBLST302SGY DUPLEX FACE PLATES AND ONE (1) - HUBBELL CAT. NO. HBLDE301SGY STYLE LINE FACE PLATES. PROVIDE ALL ACCESSORIES FOR A COMPLETE INSTALLATION. COORDINATE FLOOR BOX LOCATION WITH ARCHITECT / OWNER. LCA-41 LA-29 D.L. COMPUTER 133 LCA1-43 HALL 127 CLASSROOM 130 LCA1-44,46 CLASSROOM 131 CLASSROOM 132 FLOOR BOX SHALL BE HUBBELL CAT. NO. 3SFBC WITH HUBBELL CAT. NO. 3SFBCGYA COVER FLANGE ASSEMBLY. PROVIDE ONE (1) - HUBBELL CAT. NO. 3SFBRP DUPLEX KNOCKOUT AND ONE (1) - HUBBELL CAT. NO.L 3SFBDS STYLE LINE OPENING. PROVIDE ALL ACCESSORIES FOR A COMPLETE INSTALLATION. COORDINATE FLOOR BOX LOCATION WITH ARCHITECT / OWNER. PROVIDE POWER AND CONTROL CONNECTIONS AS REQUIRED FOR AUTOMATIC DOOR OPENER. COORDINATE LOCATION AND REQUIREMENTS WITH ARCHITECT / AUTOMATIC DOOR OPENER VENDOR. LCA-38,40 LA-30 FLUSH MOUNTED OUTLET BOX FOR AUTOMATIC DOOR OPENER CONTROL DEVICE. CONTROL DEVICE SHALL BE FURNISHED BY AUTOMATIC DOOR OPENER VENDOR. ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT, CONDUCTORS, TERMINATIONS, AND INSTALLATION OF VENDOR FURNISHED CONTROLLER. COORDINATE LOCATION AND REQUIREMENTS WITH ARCHITECT / AUTOMATIC DOOR OPENER VENDOR. SECURITY GATE CONTROLLER MOUNTED BELOW DESK. PROVIDE POWER CONNECTION TO / FROM SECURITY GATE AS REQUIRED. MOUNT AT ELEVATION SELECTED BY ARCHITECT / OWNER. STRIDDE, CALLINS & ASSOCIATES INC. CONSULTING MECHANICAL * ENGINEERS ELECTRICAL (361) 883-9199 Fax (361) 883-9177 342 S. Navigation Blvd. Corpus Christi, TX 78405-3615 Registration # F-006328 ELECTRICAL LEGEND NOTE: SYMBOL I.T. 156 SYMBOL S RACEWAY WITH NUMBER OF CONDUCTORS INDICATED WALL OUTLET WITH SURFACE MOUNTED FIXTURE AS SCHEDULED RACEWAY IN CONCRETE FLOOR SLAB AND/OR WALLS WITH NUMBER OF CONDUCTORS INDICATED LA2-15 RECEPTACLE - SEE WIRING DEVICE SCHEDULE FIRE 160 MANUAL MOTOR STARTER, SURFACE MOUNTED E LA1,2 1" DISCONNECT SWITCH CONTROL TIME CLOCK - SEE DRAWING NOTES J JUNCTION BOX UNGROUNDED CONDUCTORS CONDUCTOR SIZE INDICATED IF OTHER THAN NO. 12 AWG 208 VOLT OR 240 VOLT SINGLE PHASE CONNECTION TO EQUIPMENT NOTED #10 CONDUCTORS SHALL BE SIZE INDICATED FOR ENTIRE LENGTH OF CIRCUIT 208 VOLT OR 240 VOLT THREE PHASE CONNECTION TO EQUIPMENT NOTED LCA3-2, 4,6 PANEL "LCA3" ELECTRICAL BRANCH CIRCUIT PANEL AS NOTED 277 VOLT SINGLE PHASE CONNECTION TO EQUIPMENT NOTED OFFICE 151 DISTRIBUTION PANEL OR SWITCHBOARD AS NOTED 480 VOLT THREE PHASE CONNECTION TO EQUIPMENT NOTED TELEPHONE BOARD CONTROL OUTLET AND CONNECTIONS AS REQUIRED COMBINATION TELEPHONE/DATA TRANSMISSION OUTLET BOX SEE SPECIFICATIONS CLASSROOM 148 OFFICE 154 CLASSROOM 145 CLASSROOM 146 CLASSROOM 147 OFFICE 150 BRANCH CIRCUIT BREAKER SIZE IN PANEL INDICATED IF OTHER THAN 1P20A NEUTRAL CONDUCTOR 120 VOLT SINGLE PHASE CONNECTION TO EQUIPMENT NOTED LCA38,10 PANEL AND CIRCUIT NUMBERS CONDUIT SIZE IF INDICATED 30/2 T EXISTING RACEWAY ARROWS INDICATE HOME RUN TO PANEL CONTACTOR - C LCA312,14 LCA3-19, 21,23 UNDERGROUND RACEWAY WALL SWITCH - SEE WIRING DEVICE SCHEDULE C DESCRIPTION CEILING OUTLET WITH FIXTURE AS SCHEDULED UG LCA318,20 LCA3-25, 27,29 OFFICE 155 DESCRIPTION CEILING OUTLET WITH FLUORESCENT FIXTURE AS SCHEDULED LCA3-22, 24,26 LCA3-28,30 THIS IS A STANDARD LEGEND. ALL SYMBOLS AND ABBREVIATIONS HEREIN MAY NOT BE APPLICABLE TO THIS PROJECT. TS SPRINKLER SYSTEM TAMPER SWITCH - SEE SPECIFICATIONS FS SPRINKLER SYSTEM FLOW SWITCH - SEE SPECIFICATIONS TV TELEVISION OUTLET BOX - SEE SPECIFICATIONS RTU H FIRE ALARM SYSTEM HEAT DETECTOR FPB FAN POWERED BOX FA FIRE ALARM SYSTEM MANUAL STATION EWC ELECTRIC WATER COOLER FACP FIRE ALARM SYSTEM CONTROL PANEL EWH ELECTRIC WATER HEATER RA WP S FIRE ALARM SYSTEM SMOKE DETECTOR FL FIRE ALARM SYSTEM STROBE F FIRE ALARM SYSTEM COMBINATION HORN/STROBE F HALL 152 HWCP FIRE ALARM SYSTEM REMOTE ANNUNCIATOR HOT WATER CIRCULATION PUMP WEATHERPROOF DEVICE OR ENCLOSURE RTVAV EF PACKAGED ROOFTOP VAV UNIT EXHAUST FAN TYP. FIRE ALARM SYSTEM EXTERIOR HORN PACKAGED ROOFTOP UNIT TYPICAL WP FL C F CEILING MOUNTED FIRE ALARM SYSTEM STROBE CEILING MOUNTED FIRE ALARM SYSTEM COMBINATION HORN/STROBE C OFFICE 153 LA2-16 OFFICE 149 LCA2-22,24 LCA2-20 LA2-17 LCA2-19,21 LCA2-17 LCA2-14 LCA2-16,18 WIRING DEVICE LEGEND AND SCHEDULE LCA2-10,12 LCA2-8 SYMBOL CHARACTERISTICS #10 LA2-8 LA2-1,3,5 LA2-10,12,14 HALL 144 LA2-18 LCA3-1 #10 OFFICE 138 HALL 143 LCA2-13,15 LCA2-11 LCA2-2 LCA2-5 120-277 20 SINGLE POLE SWITCH CSB20AC1 CSB120 CSB1-20 3-WAY 120-277 20 THREE-WAY SWITCH CSB20AC3 CSB320 CSB3-20 4-WAY 120-277 20 FOUR-WAY SWITCH CSB20AC4 CSB420 CSB4-20 SD ELECTRONIC DIMMER 120 - SINGLE POLE DIMMER SWITCH NEMA 5-20R 125 20 DUPLEX CONVENIENCE OUTLET 5362A HBL5366 5366 NEMA 5-20R 125 20 GFI RECEPTACLE 2095 GF5362 7899 NEMA 5-20R 125 20 WEATHERPROOF GFI CONVENIENCE RECEPTACLE 2095 GF5362 7899 NEMA 14-20R 125/250 20 3820 HBL8410 NEMA 5-20R 125 20 ISOLATED GROUND RECEPTACLE - ORANGE IG6300 IG5362 5362IG NEMA 18-20R 120/208 20 THREE PHASE, 4-WIRE, 4-POLE RECEPTACLE 3822 HBL7250 7250-FR NEMA 18-50R 120/208 50 THREE PHASE, 4-WIRE, 4-POLE RECEPTACLE - HBL8350A 8350-A 277/480V. GEAR 18 [KA] A.I.C. GFI 120/240V. GEAR 10 [KA] A.I.C. WP GFI LIGHTING LCA2-7,9 LCA2-4,6 LCA2-1 LA2-13 A/C LOADS: HEATING COOLING OFFICE 141 CLASSROOM 135 CLASSROOM 136 CLASSROOM 137 OFFICE 139 84.3 [KVA] * MISC. EQUIPMENT LA2-7,9 10.5 [KVA] 20 50 30[KA] A.I.C. LA2-4,6 METER BY POWER UTILITY COMPANY. STOR. 140 - EXISTING PAD MOUNTED TRANSFORMER AT TECH. BUILDING "E". PANEL "MDP" SURFACE MOUNTED SURFACE MOUNTED PAD MOUNTED TRANSFORMER BY POWER UTILITY COMPANY. PAD BY CONTRACTOR. COORDINATE TRANSFORMER PAD REQUIREMENTS WITH POWER UTILITY COMPANY. LA-39 #10 #10 2"C. BY CONTRACTOR FOR METER CABLES INSTALLED BY POWER UTILITY COMPANY. UG UG 4 - #1, #6 GRND, 1 1/2"C. 2 - 4" CONDUIT WITH PULLCORD. GENERAL NOTES: 25[KA] A.I.C. 4-#6, #6 GRND., 1"C. PANEL "HA" 250A. M.L.O. SQUARE D NF WITH 1-2P-20A. EDB 30-1P-20A. EDB 4-1P-15A. EDB 6-1P-SPACES PANEL "LCA2" 1200A. 100% RATED WITH INTEGRAL GROUND FAULT AND PHASE FAILURE MAIN ELECTRONIC C/B SQUARE D I-LINE TYPE HCP PROTECTION WITH 1-3P-500A. LC 1-3P-150A. HG 3-3P-125A. HG 1-3P-100A. HG 1-3P-90A. HG 1-3P-70A. HG 2-3P-60A. HG 1-3P-35A. HG 1-3P-15A. HG 3-3P-SPACES HG TVSS DEVICE SQUARE D TVS4EMA24A PANEL "HDPA" SURFACE MOUNTED 600A. M.L.O. SQUARE D I-LINE TYPE NF (84-CIRCUIT PANEL) WITH 1-3P-30A. EGB 7-3P-25A. EGB 14-3P-20A. EGB 2-3P-15A. EGB 1-1P-40A. EGB 3-1P-35A. EGB 1-1P-25A. EGB 1-1P-20A. EGB 6-1P-SPACES EGB 2 - 2 1/2" CONDUITS WITH 3 - #250 MCM, #1 NEUT., #2 GRND., IN EACH #3/0 GRND., 1 1/4"C. 4 - 3" CONDUITS WITH 4 - #350 MCM IN EACH CONDUIT. UG NOTES: (POWER RISER DIAGRAM ONLY) PROVIDE CIRCUIT BREAKER, CONDUIT, AND CONDUCTORS AS REQUIRED BY TVSS DEVICE. NOTES: (ELECTRICAL POWER FLOOR PLAN ONLY) ONE (1) - 2-GANG BOX WITH TWO (2) - 1" CONDUIT FROM BOX TO ABOVE ACCESSIBLE CEILING. MOUNT ADJACENT TO OR ABOVE GEAR TO BE PROTECTED. CONDUCTOR LENGTH SHALL BE AS SHORT AS POSSIBLE. INSTALL OUTLET BOX FLUSH IN SUSPENDED CEILING. COORDINATE LOCATION WITH ARCHITECT. 3/4" X 10' COPPER GROUND ROD. FURNISH AND INSTALL FLUSH MOUNTED JUNCTION BOX FOR CCTV CAMERA BY OWNER. REFER TO TELEVISION / CAMERA DETAIL 3/E3-1 FOR REQUIREMENTS. INSTALL GROUND BOND TO WATER MAIN AND BUILDING STEEL AS REQUIRED BY N.E.C. 4-#1/0, #6 GRND., 1 1/2"C. 3 - #6, #8 GRND., 3/4"C. 3 - #3, #8 GRND., 1 1/4"C. 4-#6, #6 GRND., 1"C. TVSS DEVICE SQUARE D TVS4EMA16A PANEL "HK" PROVIDE A TOTAL OF TWO (2) - 2-GANG BOXES WITH TWO (2) - 2" CONDUIT FROM EACH BOX TO ABOVE ACCESSIBLE CEILING. THREE (3) - 3/4" X 10' COPPER GROUND RODS SPACED 10'-0" APART. REFER TO TELEVISION / CAMERA DETAIL 3/E3-1 FOR REQUIREMENTS. ROUTE CONDUIT BELOW EXISTING CONCRETE FLATWORK AND TRANSFORMER FOUNDATION AS REQUIRED TO INSTALL CONDUIT IN PRIMARY COMPARTMENT OF EXISTING PAD MOUNTED TRANSFORMER. INSTALL SURFACE RACEWAY 6" ABOVE COUNTER OR SPLASH. SURFACE RACEWAY SHALL BE WIREMOLD CAT. NO. 4,000 SERIES RACEWAY. PROVIDE RACEWAY BASE, COVER, DIVIDER, WIRE CLIPS, COUPLINGS, SEAM CLIP, BLANK END FITTINGS, WALL BOX CONNECTOR, FACEPLATES, ETC. AS REQUIRED FOR A COMPLETE INSTALLATION. CONDUIT RACEWAYS TO WIREMOLD RACEWAYS SHALL BE CONCEALED FLUSH IN WALL. ALL CONDUIT SHALL ENTER WIREMOLD RACEWAY VIA WALL BOX CONNECTOR. PROVIDE RED MUSHROOM HEAD MOMENTARY CONTACT PUSHBUTTON (130 VOLT RATED) IN A NEMA 3-R DIE-CAST LOCKABLE ENCLOSURE. PROVIDE ENGRAVED LABEL WHICH IS 1/8" THICK WHITE PLASTIC WITH RED SUNKEN LETTERS (3/4" STROKE) TO READ "MAIN ELECTRICAL DISCONNECT". PROVIDE REQUIRED CONNECTION TO SHUNT TRIP CONTROL COIL IN MAIN CIRCUIT BREAKER OF MAIN SWITCHBOARD "MS". REFER TO ELECTRICAL SITE PLAN FOR LOCATION. TWO (2) - 1" CONDUIT WITH PULLCORD. ROUTE CONDUIT FLUSH IN WALL FROM WIREMOLD WALL BOX CONNECTOR TO ABOVE ACCESSIBLE CEILING. FLUSH MOUNTED #6 GRND., 1/2"C. 4" 4" REFER TO TELEVISION / CAMERA DETAIL 3/E3-2 FOR REQUIREMENTS. 6'-5" 2'-10" 1'-6" PANEL "LA" PANEL "LCA" SURFACE MOUNTED SURFACE MOUNTED 150A. MAIN C/B SQUARE D NQ (54-CIRCUIT PANEL) WITH 1-3P-100A. QOB 1-3P-60A. QOB 1-2P-30A. QOB 38-1P-20A. QOB 8-1P-SPACES 250A. MAIN C/B WITH ISOLATED AND EQUIPMENT GROUND BAR SQUARE D NQ (72-CIRCUIT PANEL) WITH 1-3P-100A. QOB 3-3P-60A. QOB 45-1P-20A. QOB 15-1P-SPACES 3-#1/0, #6 GRND, 1 1/2"C. TVSS DEVICE SQUARE D TVS2EMA12A CORNER WALL CAMERA BOX WINDOW 1' 2' 4"W x 4"H x 4"D NEMA-1 BOX WITH COVER. PROVIDE 2" CLOSE NIPPLE IN COVER. FURNISH AND INSTALL FLUSH MOUNTED JUNCTION BOX FOR CCTV CAMERA BY OWNER. REFER TO TELEVISION / CAMERA DETAIL 3/E3-2 FOR REQUIREMENTS. 3 - #250 MCM, #500 MCM NEUT., #2 ISOL. GRND., #2 GRND., 3"C. 4-#6, #6 GRND., 1"C. #1/0 GRND., 3/4"C. FLUSH MOUNTED OUTLET BOX FOR AUTOMATIC DOOR OPENER CONTROL DEVICE. CONTROL DEVICE SHALL BE FURNISHED BY AUTOMATIC DOOR OPENER VENDOR. ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT, CONDUCTORS, TERMINATIONS, AND INSTALLATION OF VENDOR FURNISHED CONTROLLER. COORDINATE LOCATION AND REQUIREMENTS WITH ARCHITECT / AUTOMATIC DOOR OPENER VENDOR. #1/0 GRND., 3/4"C. 4 - #1/0, #6 GRND., 1 1/2"C. PROVIDE POWER AND CONTROL CONNECTIONS TO ELECTRIC GONG. INSTALL ELECTRIC GONG FURNISHED BY FIRE SPRINKLER CONTRACTOR AT LOCATION SELECTED BY FIRE SPRINKLER CONTRACTOR. COORDINATE REQUIREMENTS AND WIRING DIAGRAMS WITH / FROM FIRE SPRINKLER CONTRACTOR. 2" CONDUIT 75 KVA K-13 RATED . . 2" CONDUIT TO ABOVE ACCESSIBLE CEILING TV BOX TRANSFORMER "TXLCA" 45 KVA . 112.5 KVA ONE (1) - 1" CONDUIT WITH PULLCORD. ROUTE CONDUIT FLUSH IN WALL FROM WALL BOX CONNECTOR TO BELOW CONCRETE SLAB. ROUTE BELOW CONCRETE SLAB TO WALL INDICATED, RISE UP CONCEALED IN WALL TO ABOVE ACCESSIBLE CEILING. TRANSFORMER "TXLA" 250A. M.L.O. SQUARE D I-LINE TYPE HCN WITH 1-3P-150A. HD 1-3P-60A. FA 2-3P-15A. FA 12-1P-20A. FA 6-1P-SPACES TRANSFORMER "TXLK" PROVIDE POWER AND CONTROL CONNECTIONS AS REQUIRED FOR AUTOMATIC DOOR OPENER. COORDINATE LOCATION AND REQUIREMENTS WITH ARCHITECT / AUTOMATIC DOOR OPENER VENDOR. SEE DRAWING NOTES * N.E.C. PERMITTED DIVERSITY HAS BEEN REMOVED FROM LOAD QUANTITY INDICATED. LCA2-3 INFORMATION INCLUDED ON THIS DRAWING IS INTENDED TO INDICATE THE GENERAL CHARACTER AND EXTENT OF WORK REQUIRED. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. - 711.3 [KVA] LA2-11 1. - 478.5 [KVA] 276.1 [KVA] TOTAL CONNECTED LOAD PANEL "LA2" SINGLE PHASE, 4-WIRE, 3-POLE, GROUNDING LIGHT DUTY RECEPTACLE - REMARKS 102.9 [KVA] * * KITCHEN EQUIPMENT LA2-19 20 35.1 [KVA] * OFFICE 142 #10 D.L. CLASSROOM 134 SPST CONNECTED LOADS: LCA3-3,5 MANUFACTURER'S REFERENCE P. & S. HUBBELL LEVITON DESCRIPTION S S3 S4 THE FOLLOWING MINIMUM FAULT CURRENT RATINGS SHALL BE REQUIRED UNLESS OTHER FAULT CURRENT RATINGS ARE INDICATED: LA2-2 RATING VOLTS AMPS FLOOR 2'-6" 4 - #500 MCM, #1/0 GRND., 4"C. 4-#6, #6 GRND., 1"C. TVSS DEVICE SQUARE D TVS2EMA12A 4 - #3, #6 GRND., 1 1/4"C. 4 - #3, #6 GRND., 1 1/4"C. 3 - # 3, #4/0 NEUT., #6 ISOL. GRND., #6 GRND., 2"C. 4 - # 3, #6 ISOL. GRND., #6 GRND., 2"C. 3 - # 6, #3 NEUT., #8 ISOL. GRND., #8 GRND., 1 1/2"C. PANEL "LK" PANEL "LA1" PANEL "LA2" PANEL "LCA1" PANEL "LCA2" PANEL "LCA3" FLUSH MOUNTED SURFACE MOUNTED SURFACE MOUNTED SURFACE MOUNTED SURFACE MOUNTED SURFACE MOUNTED 350A. MAIN C/B SQUARE D NQ (84-CIRCUIT PANEL) WITH 1-3P-90A. QOB 1-3P-90A. QOB (S.T.) 1-3P-80A. QOB (S.T.) 1-3P-60A. QOB 2-3P-50A. QOB (S.T.) 2-3P-30A. QOB 1-3P-20A. QOB (S.T.) 1-3P-15A. QOB 1-2P-40A. QOB 1-2P-20A. QOB (S.T.) 1-2P-15A. QOB 2-1P-20A. QOB (S.T.) 28-1P-20A. QOB 10-1P-SPACES 225A. M.L.O SQUARE D NQ WITH 34-1P-20A. QOB 8-1P-SPACES 100A. M.L.O SQUARE D NQ WITH 24-1P-20A. QOB 6-1P-SPACES 225A. M.L.O WITH ISOLATED AND EQUIPMENT GROUND BAR SQUARE D NQ (72-CIRCUIT PANEL) WITH 59-1P-20A. QOB 13-1P-SPACES 225A. M.L.O WITH ISOLATED AND EQUIPMENT GROUND BAR SQUARE D NQ WITH 34-1P-20A. QOB 8-1P-SPACES 225A. M.L.O. WITH ISOLATED AND EQUIPMENT GROUND BAR SQUARE D NQ WITH 30-1P-20A. QOB STRIDDE, CALLINS & ASSOCIATES INC. CONSULTING MECHANICAL * ENGINEERS ELECTRICAL (361) 883-9199 Fax (361) 883-9177 342 S. Navigation Blvd. Corpus Christi, TX 78405-3615 Registration # F-006328 GENERAL NOTES: NOTES: 1. INFORMATION INCLUDED ON THIS DRAWING IS INTENDED TO INDICATE THE GENERAL CHARACTER AND EXTENT OF WORK REQUIRED. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. INSTALL OUTLET BOX FLUSH IN SUSPENDED CEILING. COORDINATE LOCATION WITH ARCHITECT. ENTRY PORCH 125 MOUNT AT 4'-5" ABOVE FINISHED FLOOR. ONE (1) - 2-GANG BOX WITH TWO (2) - 1" CONDUIT FROM BOX TO ABOVE ACCESSIBLE CEILING. PROVIDE A 4"W X 4"H X 4"D NEMA-1 FLUSH BOX WITH COVER. PROVIDE A 3" CLOSE NIPPLE IN COVER. PROVIDE A 3" CONDUIT WITH PULLCORD TO ABOVE ACCESSIBLE CEILING. MOUNT AT 4'-5" ABOVE FINISHED FLOOR. REMOVE EXISTING GFI RECEPTACLE AND WEATHER-PROOF COVER. PROVIDE AND INSTALL NEW DUPLEX RECEPTACLE WITH STAINLESS STEEL COVERPLATE. PROVIDE A 4"W X 4"H X 4"D NEMA-1 FLUSH BOX WITH COVER. PROVIDE A 3" CLOSE NIPPLE IN COVER. PROVIDE A 3" CONDUIT WITH PULLCORD TO ABOVE ACCESSIBLE CEILING. MECH. 207 OFFICE 106 OFFICE 105 LC-33 LC-41 OFFICE 104 OFFICE 206 OFFICE 208 LARGE CLASSROOM 124 LC-35 CLASSROOM 210 PANEL "C" CORRIDOR 204 MEDIUM CLASSROOM 111 SMALL CLASSROOM 110 STUDENT AREA 109 OFFICE 205 CONFERENCE 108 OFFICE 107 LC-40,42 LC-43 LC-29,31 OFFICE 103 WAIT/ SECR. 102 OFFICE 209 A-26 FILE STORAGE 122 JAN. 123 CORRIDOR 200 LC-17,19 LC-37,39 LC-21,23 LC-36,38 LC-25,27 EXISTING PANEL "A" EXISTING PANEL "B" FIBER OPTIC 115 WOMEN 112 LIBRARY 121 COMP. LAB 117 TELECONF. 116 MECH. 114 COMP. LAB 118 OBSERVATION 119 PRODUCTION ROOM 101 CONFERENCE 203 CLASSROOM 202 CLASSROOM 201 NEW PANEL "DPA" TO REPLACE EXISTING MEN 113 STORAGE 120 ENTRY PORCH 126 4-#6, #6 GRND., 1"C. EXISTING MAIN SWITCHBOARD "MDP" EXISTING METER EXISTING POWER UTILITY COMPANY PAD MOUNTED TRANSFORMER #3/0 GRND., 3/4"C. EXISTING PANEL "DPA" PAD MOUNTED NEMA-3R SERVICE ENTRANCE RATED 1200A. MAIN C/B WITH 1-3P-600A. (EXISTING COMPLEX) 1-3P-600A. (BUILDING D) 1-3P-400A. (ADMIN. BUILDING) 1-3P-225A. (SPARE) LIGHTING A/C LOADS: HEATING COOLING TOTAL CONNECTED LOAD 79.8 [KVA] 105.1 [KVA] EXISTING POWER UTILITY COMPANY PAD MOUNTED TRANSFORMER 198.1 [KVA] * N.E.C. PERMITTED DIVERSITY HAS BEEN REMOVED FROM LOAD QUANTITY INDICATED. TO POWER UTILITY COMPANY DIP POLE TWO (2) - 4" CONDUIT WITH 4-#500 MCM, #1/0 GRND., IN EACH. UG #3/0 GRND., 3/4"C. PAD MOUNTED NEMA-3R SERVICE ENTRANCE RATED 1200A. MAIN C/B WITH 1-3P-600A. (EXISTING COMPLEX) 1-3P-800A. (BUILDING D) 1-3P-400A. (ADMIN. BUILDING) 1-3P-225A. (SPARE) TO ADMIN BUILDING FOUR (4) - 4" CONDUIT WITH 4-#500 MCM, #1/0 GRND., IN EACH. TO EXISTING COMPLEX #2/0 GRND., 3/4"C. 3/4" X 10' COPPER GROUND ROD UG UG TWO (2) - 4" CONDUIT WITH 4-#500 MCM, #1/0 GRND., IN EACH. 4-#500 MCM, #1/0 GRND., 4"C. UG UG TWO (2) - 4" CONDUIT WITH 4-#500 MCM, #1/0 GRND., IN EACH. UG UG TWO (2) - 4" CONDUIT WITH 4-#500 MCM, #1/0 GRND., IN EACH. 4-#500 MCM, #1/0 GRND., 4"C. TO ADMIN BUILDING TO EXISTING COMPLEX 4-#350 MCM, #2 ISOL. GRND., #2 GRND., 4"C. NOTES: (POWER RISER DIAGRAM ONLY) EXISTING CIRCUIT BREAKER SHALL BE REPLACED BY NEW CIRCUIT BREAKER. REFER TO REVISED PARTIAL POWER RISER DIAGRAM - BUILDING "D" FOR REQUIREMENTS. 3.0 [KVA] 4-#4/0, #4 GRND., 3"C. 21.0 [KVA] 64.8 [KVA] 4-#1/0, #6 GRND., 2"C. 141.4 [KVA] * N.E.C. PERMITTED DIVERSITY HAS BEEN REMOVED FROM LOAD QUANTITY INDICATED. EXISTING METER 3.0 [KVA] TOTAL CONNECTED LOAD 57.4 [KVA] * MISC. EQUIPMENT 66.5 [KVA] * A/C LOADS: HEATING COOLING 16.2 [KVA] * 23.5 [KVA] MISC. EQUIPMENT UG UG EXISTING BUILDING "D" CALCULATED LOADS: EXISTING MAIN SWITCHBOARD "MDP" BOND AT BUILDING D UG FOUR (4) - 4" CONDUIT WITH 4-#500 MCM, #1/0 GRND., IN EACH. 800A. MAIN C/B SQUARE D I-LINE TYPE HCP WITH ISOLATED GROUND AND EQUIPMENT GROUND BAR WITH 1-3P-300A. LA 1-3P-225A. (PANEL "A") QB 1-3P-150A. QB 1-3P-125A. (PANEL "B") QB 2-3P-100A. QB 1-3P-60A. FA 2-3P-30A. FA 1-2P-30A. FA 2-1P-20A. FA SURFACE MOUNTED 10 [KA] A.I.C. LIGHTING 600A. M.L.O. WITH 1-3P-225A. (PANEL "A") 1-3P-125A. (PANEL "B") 2-3P-100A. 2-3P-30A. 1-2P-30A. 1-1P-20A. UG UG 120/208V. GEAR * BOND AT BUILDING D TO POWER UTILITY COMPANY DIP POLE NEW PANEL "DPA" NEW BUILDING "D" CALCULATED LOADS: SURFACE MOUNTED TVSS DEVICE SQUARE D TVS2EMA16A(C) THE FOLLOWING MINIMUM FAULT CURRENT RATINGS SHALL BE REQUIRED UNLESS OTHER FAULT CURRENT RATINGS ARE INDICATED: EXISTING PANEL "A" EXISTING PANEL "A1" EXISTING PANEL "B" SURFACE MOUNTED SURFACE MOUNTED SURFACE MOUNTED 225A. M.L.O. WITH FEED THROUGH LUGS WITH 37-1P-20A. 5-1P-SPACE 225A. M.L.O. WITH 1-2P-20A. 37-1P-20A. 3-1P-SPACE 125A. M.L.O. WITH 36-1P-20A. 6-1P-SPACE 4-#4/0, #4 GRND., 3"C. EXISTING DISTRIBUTION PANELBOARD SHALL BE REPLACED BY NEW DISTRIBUTION PANELBOARD. DISCONNECT AND RECONNECT ALL EXISTING CONDUIT AND CONDUCTORS ENTERING PANELBOARD AS REQUIRED. JOBSITE SURVEY REQUIREMENTS. REFER TO REVISED PARTIAL POWER RISER DIAGRAM - BUILDING "D" FOR REQUIREMENTS. 4-#1/0, #6 GRND., 2"C. 4-#6, #6 GRND., 1"C. PROVIDE AND INSTALL NEW CIRCUIT BREAKER INDICATED IN EXISTING MAIN SWITCHBOARD "MDP". PROVIDE ALL ACCESSORIES FOR A COMPLETE INSTALLATION. JOBSITE SURVEY REQUIREMENTS AND CIRCUIT BREAKER MANUFACTURER. EXISTING PANEL "A" EXISTING PANEL "A1" EXISTING PANEL "B" NEW PANEL "C" SURFACE MOUNTED SURFACE MOUNTED SURFACE MOUNTED SURFACE MOUNTED INSTALL NEW DISTRIBUTION PANELBOARD "DPA" IN / AT SAME APPROXIMATE LOCATION OF EXISTING DISTRIBUTION PANELBOARD "DPA" IN EXISTING MECHANICAL ROOM IN BUILDING "D". RECONNECT ALL EXISTING CONDUIT AND CONDUCTORS AT NEW DISTRIBUTION PANELBOARD AS REQUIRED. JOBSITE SURVEY REQUIREMENTS. 225A. M.L.O. WITH FEED THROUGH LUGS WITH 37-1P-20A. 5-1P-SPACE 225A. M.L.O. WITH 1-2P-20A. 37-1P-20A. 3-1P-SPACE 125A. M.L.O. WITH 36-1P-20A. 6-1P-SPACE 400A. M.L.O. SQUARE D NQ (84-CIRCUIT PANEL) WITH ISOLATED GROUND AND EQUIPMENT GROUND BAR WITH 1-3P-60A. QOB 1-3P-40A. QOB 1-3P-35A. QOB 2-2P-50A. QOB 2-2P-30A. QOB 2-2P-20A. QOB 51-1P-20A. QOB 12-1P-SPACE BOND ISOLATED GROUND BAR AND EQUIPMENT GROUND BAR IN PANEL AS REQUIRED BY NFPA 70. PROVIDE CIRCUIT BREAKER, CONDUIT, AND CONDUCTORS AS REQUIRED BY TVSS DEVICE. A 3P/60A. CIRCUIT BREAKER IS INCLUDED WITHIN PANEL. 4-#4/0, #4 GRND., 3"C. MOUNT ADJACENT TO OR ABOVE GEAR TO BE PROTECTED. CONDUCTOR LENGTH SHALL BE AS SHORT AS POSSIBLE. PROVIDE GROUND BOND TO BUILDING STEEL AND WATER MAIN AS REQUIRED BY N.E.C. REMOVE EXISTING BOND TO BUILDING STEEL AND WATER MAIN. 4-#4/0, #4 GRND., 3"C. TVSS DEVICE SQUARE D TVS2EMA12A STRIDDE, CALLINS & ASSOCIATES INC. CONSULTING MECHANICAL * ENGINEERS ELECTRICAL (361) 883-9199 Fax (361) 883-9177 342 S. Navigation Blvd. Corpus Christi, TX 78405-3615 Registration # F-006328 PANEL "HK" PANEL "LK" EWH-1 JAN. 104 STOR. 101B 101A 2-#8, #10 GRND, 3/4"C. LK-56,58 MEN 105 KITCHEN 101 CANTEEN 100 HK-8,10,12 HK-7,9,11 101C KSF-1 ON ROOF CLASSROOM 108 KEF-1 WOMEN 106 STOR. 102 KEF-1 ON ROOF RTU-1 ON ROOF MDP-7 HALL 107 D. 103 EF-2 ON ROOF VB1-4 HA-23 EF-2 HALL 124 FPB2-3 LA1-24 FPB1-4 MDP-6 HALL 109 #10 HDPA-27 RTVAV-1 FPB2-1 #10 HDPA-11 STOR. 159 HDPA-7 FPB1-5 FPB1-1 VB2-2 OFFICE 119 HA-16 DL CLASSROOM 169 OFFICE 120 I.T. 156 MULTIPURPOSE 161 FPB2-4 #10 #10 PREP. 158 HDPA-1 HALL 125 HDPA-9 COMPUTER 118 HDPA-13 FPB2-2 MDP-11 DL CLASSROOM 168 HDPA-25 D.L. CLASSROOM 121 HA-17 RTVAV-2 ON ROOF PHYSICS CLASSROOM 157 HDPA-15 FPB1-2 STOR. 117 #10 WORK 116 OFFICE 154 LA-34,36 HVAC DDC PANEL EF-3 #10 FPB2-6 EWH-2 HWCP-1 HDPA-5 #10 SEMINAR ROOM 115 STOR 164 CLASSROOM 122 MEN 163 WOMEN 162 LA-31 EF-1 ON ROOF LA-32 LA-33 JAN. 167 HDPA-17 PANEL "HDPA" MDP-10 HA-14 HALL 129 VB2-1 RTU-2 ON ROOF SEMINAR ROOM 113 RTVAV-3 ON ROOF HDPA-31 HDPA-24 HA-21 FPB3-1 PANEL "MDP" HALL 126 VB1-3 #10 HDPA-2 OFFICE 153 MDP-9 LA-35 SEMINAR ROOM 114 HA-19 HALL 165 PANEL "HA" MDP-8 VB1-2 PANEL "LA" MECH. 166 #10 FPB1-3 LIBRARY OFFICE 112 HALL 152 HDPA-3 LIBRARY 110 SEMINAR ROOM 111 I.T. OFFICE 155 FPB2-5 VB1-1 PANEL "LA1" RTU-3 ON ROOF #10 HDPA-29 #10 FPB2-7 HDPA-19 CLASSROOM 123 HDPA-21 FPB2-8 HDPA-23 FPB2-9 FPB2-10 CLASSROOM 130 FPB2-11 CLASSROOM 131 FPB2-12 DL COMPUTER 133 DL CLASSROOM 134 CLASSROOM 132 HALL 127 GENERAL NOTES: 1. 2. NOTES: INFORMATION INCLUDED ON THIS DRAWING IS INTENDED TO INDICATED THE GENERAL CHARACTER AND EXTENT OF WORK REQUIRED. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. THREE (3) - #8, #8 GRND., 3/4"C. 30A. 250V., 2P, NF, NEMA-1 DISCONNECT SWITCH. THREE (3) - #4, #8 GRND., 1"C. MANUAL MOTOR STARTER FOR USE AS SERVICE DISCONNECT SHALL BE SQUARE D CLASS 2510, TYPE FG1P. VERIFY EXACT LOCATION OF PARTITIONS, WALLS, FIXTURES, ETC. WITH DIMENSIONED ARCHITECTURAL PLANS. THREE (3) - #1, #6 GRND., 1 1/4"C. 60A., 250V., 2P, NF, NEMA-1 DISCONNECT SWITCH. RECEPTACLE FURNISHED INTEGRAL TO UNIT. ROUTE CONDUIT AND CONDUCTORS THROUGH KITCHEN HOOD CONTROL PANEL. REFER TO NOTE 36 ON SHEET E3-1 FOR LOCATION OF KITCHEN HOOD CONTROL PANEL. ROUTE CONDUIT AND CONDUCTORS THROUGH RELAY FURNISHED AND INSTALLED BY HVAC CONTROLS CONTRACTOR. COORDINATE RELAY LOCATION WITH HVAC CONTROLS CONTRACTOR. COORDINATE DEVICE LOCATION WITH DEVICE INDICATED ON SHEET E2-1. TWO (2) - #8, #8 GRND., 3/4"C. STRIDDE, CALLINS & ASSOCIATES INC. CONSULTING MECHANICAL * ENGINEERS ELECTRICAL (361) 883-9199 Fax (361) 883-9177 342 S. Navigation Blvd. Corpus Christi, TX 78405-3615 Registration # F-006328 FIRE 160 I.T. 156 FPB3-2 OFFICE 151 HDPA-4 I.T. OFFICE 155 VB3-1 HALL 152 CLASSROOM 148 HA-24 OFFICE 150 OFFICE 154 CLASSROOM 147 FPB3-4 CLASSROOM 145 CLASSROOM 146 FPB3-5 FPB3-6 FPB3-7 FPB3-3 OFFICE 153 OFFICE 149 HDPA-6 HDPA-8 HDPA-10 HDPA-12 HDPA-26 HALL 144 HDPA-28 FPB3-12 HA-26 VB3-2 HDPA-14 HDPA-16 HDPA-18 OFFICE 142 HDPA-20 OFFICE 138 FPB3-8 FPB3-9 FPB3-10 DL CLASSROOM 134 CLASSROOM 135 CLASSROOM 136 HALL 143 FPB3-11 CLASSROOM 137 OFFICE 141 OFFICE 139 STOR. 140 GENERAL NOTES: 1. INFORMATION INCLUDED ON THIS DRAWING IS INTENDED TO INDICATE THE GENERAL CHARACTER AND EXTENT OF WORK REQUIRED. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 2. VERIFY EXACT LOCATION OF PARTITIONS, WALLS, FIXTURES, ETC. WITH DIMENSIONED ARCHITECTURAL PLANS. 3. REFER TO SHEET E3-1 FOR LOCATION OF PANELS "HDPA" AND "HA". NOTES: TWO (2) - #8, #8 GRND., 3/4"C. STRIDDE, CALLINS & ASSOCIATES INC. CONSULTING MECHANICAL * ENGINEERS ELECTRICAL (361) 883-9199 Fax (361) 883-9177 342 S. Navigation Blvd. Corpus Christi, TX 78405-3615 Registration # F-006328 ENTRY PORCH 125 MECH. 207 PANEL "C" OFFICE 106 OFFICE 105 OFFICE 104 C-44 OFFICE 206 FSD LARGE CLASSROOM 124 FSD OFFICE 208 FSD C-32,34 FSD #10 MEDIUM CLASSROOM 111 SMALL CLASSROOM 110 STUDENT AREA 109 CLASSROOM 210 OFFICE 205 WAIT/ SECR. 102 CONFERENCE 108 CORRIDOR 204 FSD FPB-4-6 FSD FSD C-28,30 C-24,26 OFFICE 103 OFFICE 107 #10 FSD FPB-4-4 OFFICE 209 FSD JAN. 123 FILE STORAGE 122 RTVAV-4 ON ROOF FPB-4-5 C-8,10 FSD FSD C-18,20,22 FSD DPA-14, 16,18 FPB-4-1 FPB-4-3 CORRIDOR 200 C-45 EXISTING PANEL "A" EXISTING PANEL "B" FSD FSD FSD FSD FSD FSD FSD FSD C-12,14,16 FIBER OPTIC 115 FPB-4-2 WOMEN 112 LIBRARY 121 FSD FSD TELECONF. 116 MECH. 114 COMP. LAB 117 OBSERVATION 119 COMP. LAB 118 CLASSROOM 202 PRODUCTION ROOM 101 CLASSROOM 201 CLASSROOM 203 MEN 113 NEW PANEL "DPA" TO REPLACE EXISTING STORAGE 120 ENTRY PORCH 126 GENERAL NOTES: 1. 2. NOTES: INFORMATION INCLUDED ON THIS DRAWING IS INTENDED TO INDICATE THE GENERAL CHARACTER AND EXTENT OF WORK REQUIRED. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. THREE (3) - #1, #6 GRND., 1 1/4"C. VERIFY EXACT LOCATION OF PARTITIONS, WALLS, FIXTURES, ETC. WITH DIMENSIONED ARCHITECTURAL PLANS. FOUR (4) - #8, #10 GRND., 1"C. THREE (3) - #8, #10 GRND., 3/4"C. DEVICE FURNISHED INTEGRAL TO UNIT. STRIDDE, CALLINS & ASSOCIATES INC. CONSULTING MECHANICAL * ENGINEERS ELECTRICAL (361) 883-9199 Fax (361) 883-9177 342 S. Navigation Blvd. Corpus Christi, TX 78405-3615 Registration # F-006328 STOR. 101B 101A JAN. 104 CANTEEN 100 MEN 105 CLASSROOM 108 101C KITCHEN 101 STOR. 102 KEF-1 HALL 107 RTU-1 ON ROOF WOMEN 106 D. 103 EF-2 MULTIPURPOSE 161 HALL 109 PREP. 158 HALL 124 RTVAV-1 ON ROOF STOR. 159 OFFICE 119 OFFICE 120 DL CLASSROOM 169 HALL 125 COMPUTER 118 RTU-3 ON ROOF RTVAV-2 ON ROOF PHYSICS CLASSROOM 157 DL CLASSROOM 121 LIBRARY 110 CLASSROOM 168 WORK 116 STOR. 117 SEMINAR ROOM 115 MECH. 166 HALL 165 SEMINAR ROOM 114 CLASSROOM 122 CLASSROOM 123 HALL 127 CLASSROOM 130 1. INFORMATION INCLUDED ON THIS DRAWING IS INTENDED TO INDICATE THE GENERAL CHARACTER AND EXTENT OF WORK REQUIRED. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 2. VERIFY EXACT LOCATION OF PARTITIONS, WALLS, FIXTURES, ETC. WITH DIMENSIONED ARCHITECTURAL PLANS. 3. FURNISH AND INSTALL DUCT TYPE SMOKE DETECTORS AT SUPPLY AND RETURN AIR DUCTS FOR AIR HANDLING UNITS MARK "RTU-1", "RTU-2", "RTU-3", RTVAV-1", RTVAV-2", AND "RTVAV-3" INDICATED ON HVAC AND ELECTRICAL DRAWINGS. PROVIDE DETECTORS WITH AUXILIARY RELAYS, VISUAL (LED) ANNUNCIATORS, AND ENCLOSURE. REFER TO SPECIFICATIONS FOR REQUIREMENTS. 4. SYSTEMS CABLING SUCH AS FIRE ALARM CABLING MAY BE RUN EXPOSED ONLY ABOVE ACCESSIBLE CEILING. ALL CABLING INSTALLED IN WALLS, BELOW CEILING, IN UNFINISHED SPACES (SUCH AS MECHANICAL ROOMS), AND CABLING THAT WILL BE VISIBLE TO THE OWNER MUST BE IN CONDUIT. REFER TO SPECIFICATIONS. RTVAV-3 ON ROOF RTU-2 ON ROOF SEMINAR ROOM 113 LIBRARY OFFICE 112 GENERAL NOTES: MEN 163 JAN. 167 HALL 126 SEMINAR ROOM 111 WOMEN 162 STOR 164 CLASSROOM 131 CLASSROOM 132 D.L. COMPUTER 133 NOTES: 1/2" CONDUIT WITH PULLCORD ROUTED FROM DOOR HEADER TO ABOVE ACCESSIBLE CEILING. REFER TO SHEET E3-1 FOR FLOOR BOX AND CONDUIT STUB REQUIREMENTS. PROVIDE FIRE ALARM SYSTEM MONITOR MODULE AND CONNECTION TO MONITOR STATUS OF HOOD FIRE SUPPRESSION PANEL. STRIDDE, CALLINS & ASSOCIATES INC. CONSULTING MECHANICAL * ENGINEERS ELECTRICAL (361) 883-9199 Fax (361) 883-9177 342 S. Navigation Blvd. Corpus Christi, TX 78405-3615 Registration # F-006328 FIRE 160 I.T. 156 OFFICE 151 OFFICE 155 CLASSROOM 148 OFFICE 154 CLASSROOM 147 CLASSROOM 146 CLASSROOM 145 OFFICE 150 HALL 152 OFFICE 153 OFFICE 149 HALL 157 144 HALL 143 CLASSROOM 134 CLASSROOM 135 CLASSROOM 136 OFFICE 138 OFFICE 142 OFFICE 139 OFFICE 141 CLASSROOM 137 STOR. 140 GENERAL NOTES: 1. INFORMATION INCLUDED ON THIS DRAWING IS INTENDED TO INDICATE THE GENERAL CHARACTER AND EXTENT OF WORK REQUIRED. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 2. VERIFY EXACT LOCATION OF PARTITIONS, WALLS, FIXTURES, ETC. WITH DIMENSIONED ARCHITECTURAL PLANS. 3. SYSTEMS CABLING SUCH AS FIRE ALARM CABLING MAY BE RUN EXPOSED ONLY ABOVE ACCESSIBLE CEILING. ALL CABLING INSTALLED IN WALLS, BELOW CEILING, IN UNFINISHED SPACES (SUCH AS MECHANICAL ROOMS), AND CABLING THAT WILL BE VISIBLE TO THE OWNER MUST BE IN CONDUIT. REFER TO SPECIFICATIONS. NOTES: 1/2" CONDUIT WITH PULLCORD ROUTED FROM DOOR HEADER TO ABOVE ACCESSIBLE CEILING. STRIDDE, CALLINS & ASSOCIATES INC. CONSULTING MECHANICAL * ENGINEERS ELECTRICAL (361) 883-9199 Fax (361) 883-9177 342 S. Navigation Blvd. Corpus Christi, TX 78405-3615 Registration # F-006328 ENTRY PORCH 125 MECH. 207 OFFICE 106 OFFICE 105 OFFICE 104 OFFICE 206 OFFICE 208 FSD FSD FSD LARGE CLASSROOM 124 FSD FSD CORRIDOR 204 MEDIUM CLASSROOM 111 SMALL CLASSROOM 110 STUDENT AREA 109 WAIT/ SECR. 102 CONFERENCE 108 OFFICE 107 FSD EXISTING FIRE ALARM CONTROL PANEL FSD OFFICE 205 OFFICE 103 CLASSROOM 210 OFFICE 209 FSD FILE STORAGE 122 JAN. 123 FSD FSD FSD FSD RTVAV-4 ON ROOF CORRIDOR 200 FSD FSD FSD FSD FSD FSD FSD FSD FSD FIBER OPTIC 115 WOMEN 112 LIBRARY 121 TELECONF. 116 MECH. 114 COMP. LAB 117 OBSERVATION 119 COMP. LAB 118 CLASSROOM 202 PRODUCTION ROOM 101 CLASSROOM 201 CLASSROOM 203 MEN 113 STORAGE 120 ENTRY PORCH 126 GENERAL NOTES: NOTES: 1. INFORMATION INCLUDED ON THIS DRAWING IS INTENDED TO INDICATE THE GENERAL CHARACTER AND EXTENT OF WORK REQUIRED. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 1/2" CONDUIT WITH PULLCORD ROUTED FROM DOOR HEADER TO ABOVE ACCESSIBLE CEILING. 2. VERIFY EXACT LOCATION OF PARTITIONS, WALLS, FIXTURES, ETC. WITH DIMENSIONED ARCHITECTURAL PLANS. REMOVE EXISTING REMOTE ANNUNCIATOR AND RELOCATE TO NEW LOCATION INDICATED BY NOTE 3. PROVIDE AND INSTALL A STAINLESS STEEL COVERPLATE ON / OVER EXISTING FLUSH MOUNTED BOX. 3. FURNISH AND INSTALL DUCT TYPE SMOKE DETECTORS AT SUPPLY AND RETURN AIR DUCTS FOR AIR HANDLING UNIT MARK RTVAV-4 INDICATED ON HVAC AND ELECTRICAL DRAWINGS. PROVIDE DETECTORS WITH AUXILIARY RELAYS, VISUAL (LED) ANNUNCIATORS, AND ENCLOSURE. REFER TO SPECIFICATIONS FOR REQUIREMENTS. 4. SYSTEMS CABLING SUCH AS FIRE ALARM CABLING MAY BE RUN EXPOSED ONLY ABOVE ACCESSIBLE CEILING. ALL CABLING INSTALLED IN WALLS, BELOW CEILING, IN UNFINISHED SPACES (SUCH AS MECHANICAL ROOMS), AND CABLING THAT WILL BE VISIBLE TO THE OWNER MUST BE IN CONDUIT. REFER TO SPECIFICATIONS. 5. CONTRACTOR SHALL PROVIDE EXTENSIONS FROM THE EXISTING FIRE-LITE MS502UD FIRE ALARM CONTROL PANEL TO SERVE NEW DEVICES INDICATED AS REQUIRED. JOBSITE SURVEY EXTENSION REQUIREMENTS. 6. CONTRACTOR SHALL PROVIDE RELAYS, POWER SUPPLY, LINE CARD, ETC., AS REQUIRED TO ADD NEW DEVICES TO THE EXISTING FIRE-LITE MS502UD FIRE ALARM CONTROL PANEL. JOBSITE SURVEY REQUIREMENTS. 7. CONTRACTOR SHALL RE-CERTIFY THE EXISTING FIRE ALARM AND DETECTION SYSTEM WITHIN THE BUILDING AT OR NEAR COMPLETION OF PROJECT. THE CONTRACTOR SHALL INSERT THE INSPECTION / CERTIFICATION REPORT WITHIN THE OPERATION AND MAINTENANCE MANUALS. NEW LOCATION FOR EXISTING REMOTE ANNUNCIATOR. EXTEND FIRE ALARM CABLE / CONDUCTORS AS REQUIRED. MOUNT SMOKE DETECTOR IN SKYLIGHT AT OR NEAR PEAK AS REQUIRED BY NFPA 72. COORDINATE REQUIREMENTS WITH ARCHITECTURAL SECTIONS / DETAILS. PROVIDE MONITOR MODULE TO MONITOR STATUS OF FIRE SMOKE DAMPER. COORDINATE REQUIREMENTS WITH HVAC CONTRACTOR. STRIDDE, CALLINS & ASSOCIATES INC. CONSULTING MECHANICAL * ENGINEERS ELECTRICAL (361) 883-9199 Fax (361) 883-9177 342 S. Navigation Blvd. Corpus Christi, TX 78405-3615 Registration # F-006328