Transcript
Summary of Cost for Taj Orientation Center, Agra SI No. (A)
1 2
3 4
5 6
7 8 9 10 11 12 13
14 15 16 (B)
(C)
(0) (E)
(F) (G)
(H) 1 2
TOTAL (lln Lacs)
Name of Items INTERNAL & EXTERNAL ELECTRIFICATION W irinQ System Fan System . Earthina & Liahtina Protection Earthina Svstem Indoor and Out d oor lia ht fi xures Lioht pole C able/W irino .(L.T . cab le) Cable Trays H. T. System L.T. Pane ls MOBS/DBS LT Cab les System Feede r Piller Safety Ite ms Tele phone Syste m LAN Network Svstem TOTAL FIRE FIGHTING SYSTEM Fire Pump & Hydrant works Pi ping for fire figh ting Sprinkle r Syste m Fire extinguisher Fire electric panel Fire alarm system TOTAL HVAC HVAC Embeded under floor piping system TOTAL
68.79 4.29 8.57 2.00 798.35 35.67 6.48 263.68 22. 67 53.31 2 1.58 27.25 3.16 5.95 2.13 1.12 1325.00
.'
105.31 230.30 38.86 43. 20 7.63 109.30 534.60 1231.45 316 .05 1547.50
3407.10
TOTAL(A) TRANSFORMER 1000 KVA (2 NOs.) 500 KVA VOLTAGE STABLIZER(4 Nos.} 3 KVA INVERTER 10 KVA INVERTER 500 KVA D.G. Set (4 Nos.) • LIFT & ESCALATOR 13 Passanoer Lift (2 Nos.) Esca lator TOTAL(B) GRAND TOTAL (A+B)
21 .31 _32.20 0.00 2.84 187.41 0.00 37. 18 70.40 351.34
3758.44
~
•' r.,..__)
.. - ~ ' '
~'
--
BOQ OF TAJ ORIENTATION CENTER AT AGRA
SL. NO ITEM OF WORK 14 WIRING SYSTEM (Interna l w iring) :
Unit
Qty.
14.1
Supply & wiring of Submai n with two number 2.5 sq.mm. FR PVC insulated multi-strand single core copper cond uctor cab le in heavy guage 25 mm outer diameter PVC conduit pipe partly concealed in the wall and partly laid 111 slab alongwith the Metre 24000 rein forcement before con er eting . complete wilh 1.5 sq. mm. FR PVC insulated multi-strand copper conductor cable as earth wile drawn rnside the cond uit. comple te in all respects .
14.2
Supply & wiring of sub main with two number 2.5 sq . mm. FR PVC insulated 1100 volts grade single core copper conductor cable in 20mm dia heavy guage rigid steel conduit on surface, Metre with one no. 14 SWG copper earth continu ity wire etc, complete in all respects.
14.3
Wiring point for light with 1.0 sq.mm. FR PVC insulated multistrand single core copper conductor cable in heavy guage 25 mm outer diameter PVC conduit pipe partly concea led in the wall and partly laid in slab alongwith the reinforcement before concreting. complete with 1.5 sq mm. FR PVC insulated multistrand copper conductor cable as earth wile drawn inside, modular switch & ceiling rose/angle/ballen holder etc. complele in all respects, as directed, including matching clour wash.
Rate
AMOUNT
Reference
.,
98.00
2352000.00
1307(C)
950
170.00
161500.00
1301 (B)
Each
4000
527.00
2108000.00
138(C) + 187 (A)
14.4
Wiring point tor light with 1.5 sq.mm . FR PVC insulated single core copper conductor cable in heavy guage 20rnm dia heavy guage rigid steel pipe on surface, complete with 8 SWG GI Earth continuity wire drawn inside tr1e conduit, modular switch & Each ceiling rose/angle/batten holder on 3 mrn thick phenolic tanlinated backelite-s t1eet etc. cornplete 1n all respects, as directed, including matching cloUJ Welsh.
800
521 .00
416800.00
121 + 187 (A)
14.5
Wiring point for fa n I fresh air fan (ligt1t duty exha ust fan) with 1.0 sq.mm. FR PVC insulated multi-strand single core copper conductor cable in heavy guage 25 mm outer diameter PVC conduit pipe partly concealed in the wall and partly taid rn slab alongwith the rernlor cement before concrellng , complete with 1.5 sq. mm . FR PVC insulated multi-strand copper conductor cable as earth wite drawn inside, modular switch & ceiling rose etc. comple te in all respects, including matching clour wash.
Each
162
607.00
98334.00
140 ( C)+ 187 (A)
14.6
Wiring p oint for fan I fresh air fan (light duly exhaust fan) with 1.5 sq.111111. FR PVC insulated multi-strand ~ingle core copper conductor cab le in 25 mm outer diameter heavy guage ngrd steel pipe on surface complete with 8 SWG GI Earth conl1nuily wire drawn inside the conduit rnodu ar switch & ceiling rose etc. complete in all respects, including ma tch ing clour wash.
Each
30
589.00
17670.00 123+ 187 (A)
14.7
Supply & fixing of fan hook fabricated from MS rod for ceil ing fan each as also electronic fan regulator 120280 V. ISi marked, on tile existing switch board including making connections, required materic:il, labour, T/P etc. for proper completion of work to U1e satisfaction of the Engineer-i11charge of th e work
Each
162
354.00
57348.00 1123 + 1203 (A)
~~l~ ~o ~o -no ~-o f.m ~o ftrmr ~
1i~~ -.:fitf>!f_ ~C:l80; service life: 50,000h at 80% luminous flux; includes separate con trol gear; includes glass diffuser luminaire housing made of Aluminium; white trim: degree of protection: IP44 from room; class of protection II ; ceiling cutouts: 0120mm, recessed depth: 100 mm; Make: Trilux I Ssasso-XAL I Alpha Led
8.4
No
2,365,200.00
MR
No
290
4,777.00
1,385,330.00
MR
No
70
12,774.00
894, 180.00
MR
No
260
22 ,960.00
5,969,600.00
MR
'
-
8.5
3,240.00
'
SITC of LED Circular cylindrical surface-mounted downlight; with integrated LED module; aluminium reflector with reflection intensifying coated surface. Highly specular reflector. With symmetric narrow-wide light distribution. Luminaire luminous flux 1800 Im, Connected load 22 Watt, Luminous efficiency of luminaire 81 lm/W. Light colour neutral white (nw). colour temperature 4000 K, Colour rendering index Ra > 80. Specific parameters lo, de fining LED serv1c~ life L80 LED 11101 talily B10 Lurrn11a11e body of aluminium. Functional g,oo ve in cover ring for toolfree attachment of covers. Colour white. Integrated cover ring of die-cast zinc, powder-coated white. Luminaire diameter 0 238 mm, Luminaire height 162 mm. With electronic lransformer, switchable. Make: Trilu x Onperla 02 HR LED 2000 nw ET 01 I Zum tobel I Alpha Led SITC of Oust. shock & weather Uet) Proof Lurninaire suitable for 2 x 28 watts TL-5 Lamps, with electrinic ballast with 0.98 power factor, with high grade Polycarbonate housing with polycarbonate/stainless steel fastening clips & and UV stabilized hinged diffuser cover with all accessories mounted on a CRCA gear plate suitable for ease of maintenance. The enclosure sllall have an ingress pro tection of IP-65. Make: TCW'150 2, 80. Luminaire body of dia cas t aluminium colour white (RAL 9010), Luminaire diameter 403 mm. luminaire height 68 mm. Safety class I, Protection rating IP20, impact resistence 0.2.J. Heat resistance 650 "C" With electronic transformer. switchgear Type: POLARON WD2 ITR 40/55E (40/55w)
No.
30
19,604 .00
588,120.00
MR
"
8.7
SITC of 1 meter Track with Data bus 3 Circuit dali dimmable , dimensions 36rnmX32mm inclusive of live end with power and data feed and dead end & Continous connectors with L shape & T shape. Make: Alpha Led I Hoffmeister I Erco
No.
110
6,190.00
680,900.00
MR
8.8
SITC of 2 meter Track with Data bus, 3 Circuit dali dimmable, dimensions 36mmX32mm inclusive of live end with power and data feed and dead end & Continous connectors with L shape & T shape Make: Alpll a Led I Hoffmeister I Erco
No.
110
6,190.00
680,900.00
MR
No.
120
30,906.00
3,708,720.00
MR
No.
95
29,668.00
2 ,8 18,460.00
MR
8.9
SITC of Track Mounted Compact hi gh output 23w LED Spot Light with professional optics with varying field option, die-cast constru ction , three circui1 track adaptor as standard , supplied with integral non-dimming driver. Lockable lilt and rotation upto 355 degree. ou tpu t of 2000 lumens . CCT 3000K. LED modules with a narrower colour temperature tolerance and binning within 1 x 2 MacAdam Ellipses. inclusive of softening lens I honeycomb louvre . single Led module only with reflectors to control the light. head diameter approx 85mm and the fixture should be properly heat synced . Make: Apto Tl'ack, Alph a Led I Hoffmeister I Erco
SITC ofTrack Mounted Compact high output 15w LED Spot Light with professional optics with varying field option, die-cast construction. three circuit track adaptor as standard, supplied with integral non-dimming driver, Lockable till and rotation upto 355 degree. outpu t of 1300 lumens. CCT 3000K, LED modules with a narrower colour temperature tolerance and 8. 10 binning within 1 x 2 MacAdam Ellipses, inclusive of softening lens I honeycomb louvre, single Led module only with reflectors lo control the light. head diameter approx 85mm and the fixture should be properly hea t synced . Make: Apto T1ack. Alpha Led I Hofl,1le1:;t-,r I Erco
-
Pendant/Surface/ Recessed Moumed Luminaire LINE 50 LED 22W, 18501m, 4000K, dimmable, direct light distribution through polycarbonate diffuser, profile in extruded aluminum powder coated white finish, pendant mounting through 8.1 1 suspenders, integral HF electronic control gear, IP20, L= 11 80mm ; W=50mm: H=70mm : PL=300-1500mm max. Make:Trilux I XAUEquivalent
~
, 50.000 hrs, IP67 rated with loadbea1ing capacity of 3 tons , inclusive of remote driver. Make: L TL-E-A 1VZ0 9005, I Dot Spot/ Bega/Equivalent
No.
SITC of concre te embedded 10 W LED luminaire, wi th body in 316L stainle:,;s steel, wi th tempered glass pla te and mounting sleeve 150 mm x 0 80 mm included, pivoting lamp unit with ball mechanism, giving fl exi bility of +/- 25 degree tilt. fixtue to be IP68 wi th Thermoprotect system , 8.15 avoiding overheating of the spotlight ensuring a very long life of No. the LED> 35,000 hrs, connection cable 2 m fixture in 24VDC, having load bearing capacity of 3 tons with remote driver from meanwell. Make: Brilliance, Dot-Spot , German y I Equivalent SITC of 3 Wall wall recessed Led luminaire with glare protection, cavi ty wall sockets, protection class IP 64, also suitable for exterior use, stain less steel filling screws and seal 8.16 ring, housing Anodized aluminum, with square opaque cover, direct connection lo 230 VAC power supply. Make: Side Light. Dot-Spot. Germany Equivalent
No.
SITC of LED STRIPS-FLEXIBLE Bnghl energy saving long life (20,000 ilrs usage) flexible LED liglll Tape wil11 lra11sparent PU casing fixlu re with user fri endly driver for a maximum length 8.17 of 5 M housing with double sided adhesive tape: suitable for 9.6 Watt/mtr. tape suitable for 24V, driver suitable for 24VDC, integrated (non-dimmable) power supply Make · I Dot-Spol I BarthelmelEquivalent
Mtr
SITC of of Flexible Linear Luminaire wit h homogenous illumination Wa ttage Approx 10W l rntr IP68 24VDC wi th 8.18 complete driver & accessories. Make: Aqual uc, Barthelme I Dot-Spol I LEC
Mtr
165
106,026.00
17,494,290.00
MR
280
84,639.00
23,698,920.00
MR
30
6,457.00
193,710.00
MR
60
48 ,243.00
2,894,580.00
308
14,620.00
'
1,000
4,502,960.00
MR
~
,
~
3,400.00
3,400,000.00
MR
• 180
37,277.00
6, 709,860.00
MR
,, _;'r
SITC of Schreder make Modular family LED luminaire BRIKA 27W LED, an IP66 LEDSafe© optic compartment. a separate IP 66 control gear compartment with an impact resistance of IKOS, an extruded aluminium painted housing, a toughened glass protector, permanently seale d with a robotically dispensed silicone sealan t, closed at 01 1e end b\1 an end cover and the othe, end by a frame a11d ooor assembly (lo access control gear) both made of injection moulded polycarbonate, a removable control gear plate, safety plug and socket system, a high pressure die cast aluminium painted mounting spigot 8. 19 suita ble for horizontal mounting (0 32 - 42mm) with tilt No. flexibility of (+)(-) 10 degrees , with LensoFlex2® technology, PMMA len ses with wide pt1otometry for increased pole spacing , lifetime residual flux @ Tq 35 C @ 50.000 t1ours = 70% , Ta = SOC , surge protection of 10kV (1n d1frerer111al and co111mon mode), Powe, Factor > 0 90. Colour Rendering Index > 65 and neutral white lig ht (4,250oK). Model: BRIKA - 27W - NW, Make: Sch reder I Haper/Osram/ Equivalent
SUB TOTAL
60
11, 155.00
669,300.00
MR
'
79,834,694.50
•
,.. BOQ TAJ ORIENTATION CENTER AT AGRA S L. NO
9 9.1
ITEM OF WORK
Unit
Qty.
LIGHT POLES SITC of flnngc mounted 4 mlr lo ng ho t dip galvaniseu PU coated of approved color CON ICA L polas w1tl1 145 111111 bottom A/F & 75 mm lop A/F made up of 3 mm thick HT sheet along with base plate of size 240X240X 12mn1 with maximum wind speed of 169 Km/hr as required . The pole top shall be complete with 300 mm long brika si ng le arm bracket at 4flll with a tilt of 10 degree with lightening bolts as required. Tile followiny may be housed in the window provided for cable termin ation including the ir supply and fixing: : 6mm thick laminated mou11ling shee t o f suitable size inside the window by providing and weld ing three No GI slnps; 4 mm thick of suitable length and ha ving suitable size tapped holes - 10 nos. as required . : 1 No. : A set of 20 Amp brass neutral link, 2 way copper bus bar on existin g laminated sheet : 1 Set. : 4 way , 32 Amp heavy duty term inal block suitable for 10 sq. mm conductor- 2 nos. and shorting links (4nos.) 0 11 DIN c t1annel of suilable le11gth - on the exisung laminated sheet. : Earth stud welded al suitable height with two nos. washer, spring wa sher & nuts. : 2 Nos. 4 Nos. (20mm dia x 470111111 long) G .I founda tio n bolts with nuts washer, 2 nos. templates (4 mm thick, 220mm x 22 Omm size), making of 4 Nos. x 24 mm dia holes w ith PCD of 205mm for 4 M Poles . The template (Top) shall have a 120 mm dia hole at center for cable e11t1y Make: Brika Pole. Schreder I BajHj/Equ1valent
AMOUNT
REMARKS DSR2014/UPPW
'
No 9.2
Rate
80
24722.00
1977760.00
MR
944720.00
MR
CIVIL FOU NDATION & ERECTION OF POLES
9 .2. 1 Preparation of concrete foundation, installation, testing and commissioning and earthi ng for 4 M Pole. The concrete foundation sha ll be of size 550 m rn long, 550mm wide and 1200mrn deep with necessary excavation, providing & laying in position 1·2:4 RC C with laying base concrete: 150 mm thick (1:4:81.e. 1 cement: 4 coarse sand: 8 graded stone aggregate; 40mm nominal size). Providing, straightening, cutting , bending and placing in position reinforcement column of cold twisted bar of 8 mm dia. x 1OOOmm long (Apprx.) x 1 O Nos. and reinforcemen t ring of cold twisted bar of 8mm dia . x 1600 mm 10119 (Apprx.) x 8 Nos. (with 190 mm spacing) , casting RCC 1:2:4 including positioning of foundation bolt (Template) & PVC Tee & PVC Pip e of 65 mm dia. for cable entry at desire level slriclly as per drawing; and as per direction of Engineer-in-Charge as required .
.., No.
Preparation o f concrete foundatio n . installation , testing and commissio ning and earthing for Outdoor Bollard and Ground Burial Light. T he concrete foundation sha ll be of size 300 mm long , 300mm wide and 450rnm deep with necessary 9.2.2 excavation. providing & laying in p osition. Cable entry at desire level and all o ther conditi ons stric tly as per drawing 8nd as µer direction o f Engmee1 -:r,-Charge as required.
Sub Total - Light Poles
r-
80
11809.00
• No.
90
7158.00
644220.00
3566700.00
MR
BOQ OR IENTATION CENTER AT AGRA Unit SL. NO
ITEM OF WORK
10
LT CABLE SYSTEM : Supplying & laying of Aluminiu111 conductor. XLPE I PVC i nsulated, Armo ured served with sheathed cables. 1100 Volts g rade at a depth of 750 mm be low ground level over a cushion of 75 mm thi ck sa nd all around and protected with burnt bricks on s id e s and on top. On surface the cable run s hall be fix ed on MS clam ps etc. of suitable size or as directed by the engine er in charge, complete in all respect. T he armoring of the cable shall l.Je properly connected w ith the ea1ll I conductor by clamps etc
Qty.
Rate
AMOUNT
REMARKS DSR2014/UPPW
SC H. ITEMS
.
'
501 10.1.1 : 4C x 6 sq. m m. A2XWY 10.1 .2 : 4C x 4 sq . mm. A2XWY
M M M
9 30 515
10.2.1 : 06 sq. n 1m.
No .
10.2.2 : 04 sq . m m .
10.1.3 : 2C x 4 s q. m m. YWY
10.2
10. 3
860
255. 00 236.00
2 19300.00
73 .00
37 595.00
480
12. 00
5760 .00
(b)
No .
480
12.00
5760.00
(a)
No .
60
62 .00
3720.00
(g)
No.
60
49.00
29 40.00
(f)
M
360
427.00
153720.00
21 9 480.00
S upply & fixing of p lain or pin type copper tin plated c able socket (lug) to t11e cable leads. insulating with tape and making connection etc. complete in all respect as per direction of Engineer in charge.
(g) (f) 1 .17.20
504
S upply & fixing of Brass Nickle pla ted compression g land for PVC insulate d & armoured served sheathed, underground ca ble including rubber ring etc. complete in all respect. The armouring of the cab le shall be prope rly connected with the earth as per directi on of Engineer- lncharge. 503
10.3.1 : 4C x 6 sq. mm . A2XWY 10.3.2 : 4C x 4 sq. mm. A 2XWY
10.4
Providing. laying and fixing following dia G.I. pipe (medi um c lass) in ground com plete with G.I. fi ttings including trenching (75 cm deep) and re-filling e tc as required at s ite.(on ly For Ro ad Crossing) DSR-2014
10.4 .1 : 50 mn1 dia. Sub Tota l - LT Cab le Sy stem (Sch. Items)
.
...
648275.00
14.1 3.1
BOQ OF TAJ ORIENTATION CENTER, AGRA SL. NO
ITEM OF WORK
6
LT CABLE SYSTEM (Up to MOB - 1/C): S.I.T.C. 1100 Volts grade Cable as per I S 7098, P1 1 (Latest Edition) with Stianded Alu111inium concJuuor: XLPI:: insulated, · multi-core. bunched , Armoured/un-armoured with overall PVC insulation I Copper stranded conductor; PVC insulated as per I S 1554 (Latest Edi tion) Armo ured/un- armoured with overall PVC insulation. Cable shall have Nominal identification Plates al booth ends ('supply from' & ;supply lo') . The sizes are as follows :
Unit
Qty.
M
4370 900 1050 810 1010 650 550 320 275 480 500
Rate
AMOUNT
Remarks
SCH. ITEMS
A
6.1 6.2 6.3 6.4 6.5 6.6 6.7 6.8 6.9 6.10 6.11
8
6.12 6. 13 6. 14 6.15 6. 16 6. 17 6. 18 6.19
c
6.20
D
6.21 6.22 6.3 6.3.1
: 3.5C x 400 sq. mm l\2XFY 3.5C x 300 sq . mm. A2XFY 3.5C x 240 sq . mm. A2XFY 3.5C x 185 sq . mrn. A2XFY 3.5C x 150 sq. mm. A2XFY : 3.5C x 50 sq. mm. A2XFY : 3.5C x 35 sq. mm . A2XFY : 4C x 16 sq. mm. A2XWY : 4C x 4 sq . mm. A2XWY : 3C x 4 sq. mm. YWY : 1OC x 2.5 sq. mm. YWY Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed I XLPE aluminium conductor cable of 1.1 KV grade as required.
M
M M M M M M M M M
No No No No No No No No
100 8 12 4 10 4 6
: 04 sq. mm. Supply & fixing of Brass Nickle plated compression gland for PVC insulated & armoured served sheathed. underg.ound cable including rubber ring etc. complete in all respect The armouring of the cabl e shall be properly connected with the earth as per direction of Engineer-lncharge.
No
.
6.3.1.1 : 600 mm width X 50 mm depth X 2.0 mm thickness 6.3.1.2 : 450 mm width X 50 mm depth X 2.0 mm thickness 6.3.1.3 : 200 mm width X 50 mrn depth X 1.6 mm thickness
'
.
10,898,780.00 1,8 16,200.00 1,785,000.00 1,099, 170.00 1,147,360.00 367,250.00 213,400.00 104,960.00 64,900.00 144,960.00 29 1,500.00
501 (t) (s) (r) (q)
(p) (I) (k) (i) (f)
MR DSR-2014
: 3.5C x 400 sq. mm. A2XFY : 3.5C x 300 sq mm. A2XFY : 3.5C x 240 sq . mm. A2XFY : 3.5C x 185 sq. mm. A2XFY : 3.5C x 150 sq. mm. A2XFY : 3.5C x 50 sq. mm. A2XFY : 3.5C x 35 sq. mm. A2XFY : 4C x 16 sq. mm. A2XWY Supply & fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of Engineer in charge.
: 4C x 4 sq. mm. A2XWY : 3C x 4 sq. mm. A2XWY CABLE TRAYS Supplying and installing following size of perforated pre-painted M.S. cable trays wit11 perforation not more than 17 5%. in convenient sec1 ions, joined with connectors suspended from the cei ling with M S. suspenders including bolts & nuts. painting suspenders etc as required.
2,494.00 2,018.00 1,700.00 1,357.00 1,136.00 565.00 388.00 328.00 236.00 302.00 583.00
2
1,300.00 1,032.00 921.00 745.00 547.00 325.00 256.00 233.00
130,000.00 8,256.00 11 ,052.00 2,980.00 5,470.00 1,300.00 1,536.00 466.00
44
12.00
528.00
No No
503
...
""
2 12
49.00 49.00
9.1.31 9.1.30 9.1.29 9.1 .27 9.1 .26 9.1.22 9.1.21 9.1.33 504(A)
98.00 588.00
F D
. M M M
800 600 270
1,317.00 1,061.00 636.00
1,053,600.00 636,600.00 171 ,720.00
DSR-2014 4.1.7 4.1.6 4.1.3
6.4
6. 4.1 6.4.2 6.5 6.6
6.6.1 6.6.1 6.7
6.7.1 6.7.1 6.7. 1
m -
Supplying and installing following size of perforated pre-painted M.S. cable trays Tee's wi th perforation not more than 17.5%, joined witl) connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. : 600 mm width X 50 mm depth X 2.0 mrn thickness : 450 mm width X 50 mm depth X 2 0 mm thickness PIPES
OSR-2014
No. No.
4 4
4,758.00 3,774.00
19,032.00 15,096.00
Providing , laying and fixing following dia G.I. pi pe (medium clas s) in ground comp lete with G.I. fittings including trenching (75 cm deep)and rc-iill ing etc as required : 100 mm dia : 50 mm dia.
DSR-2014 M M
1100 " 500
1,438.00 428.00
1,581,800.00 214,000.00
Providing , lc1y1ng and fixiny following d 1c1 RCC pipe NP2 class (light duty) 111 ground complete with RCC co llars. Jointing wi th cemen t mortar 1:2 (1 cement : 2 fin e sand) incl uding trenching (75 cm deep) and refilling etc as req uired. 300 mm dia 250 mm dia 150 mm dia SUB TOTAL LT CABLE SYSTEM (SCH. ITEMS)
4.4.7 4.4.6
14.13.3 14.13.1
OSR-2014
M M M
750 650 500
538.00 432.00 365.00
403,500.00 280,800.00 182,500.00 22654402.00
14.14.4 14.14.3 14.14.2
24 70 40 400 1800
8,075.00 5,700.00 4,750.00 7,125.00 45.00
193,800.00 399,000.00 190,000.00 2,850,000.00 81,000.00
MR MR MR MR
NON SCH. ITEMS 6.8
CABL E PIT/TRENCH Provide Cabl e Pit/Cable trench of the following dimensions with removable cover. The pit/trench shall be made with PCC bottom and 230 mm thick masonary wall. The cable pit cover shall be of heavy duty Cast Iron size 500 x 500 / 300 x 300 as the case may be . The cable Trench shall be covered wi lh (out-door) 40 mm thick pre-cas1 Concrete I (in-door) 6 111111 checkered M. S. Plate removable covers as required. Pipes shall terminate in the pit/trench as per drawing .
6.8. 1 6.8.2 6.8.3 6.8.4 6.8.5
: 11000 x 1000 x 900 (Deep) mm cable pit. : 600 x 600 x 900 (Deep) mm cable pit. : 450 x 450 x 900 (Deep) mm ca ble pit : 1000 x 1000 mrn .(deep) cable trench MS angle 50x50x6 mm size= 360 meter (400x4.5=1800Kg.) SU B TOTAL LT CABLE SYSTEM:
'
.
No. No. No. M Kg.
3,71 3,800.00
2807
BOQ ORIENTATION CENTER AT AGRA SL. NO
1 1.1
1.2
1.3
ITEM OF WORK
Unit
Qty.
Rate
AMOUNT
Remarks
SCH. ITEMS H.T.SYSTEM Supplying and making indoor cable en d tern1111auo11 with heat shrinkable jointing kit complete with all accessories including lugs suitable for followi ng size of 3 core . XLPE aluminium conductor cable of 11 KV grade as required :
No
7
4 ,625 .00
32,315 .00
DSR 20 14
No
3
7 ,776.00
23,328.00
10.4.2 DSR 2014
: 3 C x 240 sq. mm. Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete w ith all accessories including lugs suitable for following size of 3 core. XLPE alum1n1urn co nductor cable of 11 KV grade as requirecl . : 3 C x 240 sq. mm. A2XFY cable. SUB TOTAL H. T. SYSTEM (SCH. ITEMS) NON SCH. ITEMS 11 KV DOUBLE POLE STRUCTURE Supply, erection. testing and com mi ssioning of 2 pole structure for providing 1 No. 11 KV ,400A GOS in nccordance wi th IE rules. & local authority specificat,on and drawings and compris ing o f the following.
a
2 Nos. 11 mtr. long MS STEEL poles complete with. pole excavation. MS STEEL foundati on, and back filling complete MS steel channel/ang le iron e tc.
b
1 Set of cross arms, branching. clamps and painting complete with GI nut, bolts & washers as req uired (for GO & DO) . LA con nection .
c
1 se t 11 KV Insulator complete with spindles & hardware & DOG 11KV ACSR conductors com plete as requi red.
d
1 No. 11 KV 400A TP Gang o perated Air break switches complete with 25mm dia GI pipe operating machanism , handle & locking arrangement.
e
1 set of 3 nos.1 1KV single pole drop out fuse complete with barrel fuses, and mounting arrangement.
f
1 set (3 nos.) 11KV lightning arrestor and connecting to all phases.
g
1 No. 150 mm dia GI pipe class 'B' (for XLPE cable protection) as required.
h
2 Set 50mrn dia 3m lon g G I pipe earthing with 25 x 6 mm GI earth strip complete as required (for GO & DO & LA)
1.4
. 10.5.2 5570 3.0 0 No.
1
MR
I
231842.00
231842.00
11 KV VCB PAN EL S. I.T.C. of 11 KV Vacuum Circu it Breaker panel - indoor mou nted, self- standing type (with 25KA/1Sec fault level) conforming to I S: 13327 I IEC 60298/60694 with degree o f protection to IPH3 as per IS 3427. The VCB shall conform to I S: 13118 I LEC 62271-1 00/200 and have a continuous cu rrent capaci ty of 630 Am ps (25KA/1 sec) qnd shall be horizontally isolated, horizontally draw-out type. three pole, trip free , complete with 24V DC trip- coil , Au xiliary contact for trip circuit, Spring Charging Motor, C T, P T metering & protection as required . Th e electrical components sh all be as follows: INCOMER VCB : 1 No. 630 Amps (25KA/1 sec) draw-out type, three pole, trip free motorised V acuum Circuit Breaker.
,
~
~
/
I
BUS BARS: 1 nos. aluminium bus bars with 800A cw rent carrying capacity with uniform cross section th rough out the panel length. OUT -GOING VCBs : 2 Nos. 630 (25KA/1 sec) Amps draw-ou t type, 1hree pole. trip free moto rised Vacuum Circui t Breakers. : 1 No. 11 KV/"110 V Bus Poten tial T ra nsformer (P .T .) or class- 1_ accuracy, con forming to IEC: 186(1987), com plete with HRC fuses on both sides . P. T. sha ll h ave 100 VA (minimum) capacity su fficient for protection and measuring circu its. : Du al ratio C. Ts 150/5/5 Am ps in llie 1/C VCB panel & 40/5/5 Am ps in th e ou t-giony VCB pane ls for metering and protection (0 2/5P1 0 accuracy) with suitable VA rati ng (1 5 VA rninrn), conforrni11y to IEC 44 1 (1996).
'
: Cable end-box for ca ble in the 1/C & OIG VCB panels up lo 11 KV, 240 s q. mm .. 3 core XLPE type (E). PROTECTION & METE RING for all VCB breakers· : Digital Multifunctional me ter (V. Alarm & Trip fa cilities.
A.
KWH, KVA. F & Pf) with MDI wi th
: Phase indication LED la mps Protection Relay -Numerical Non Communicable & other Auxilliary relays: : 1 No. 4-pole, non-directional. IDMTL 30/C+1 E/F w ith instante nous element relay. : 1 No. Combined U/V, ON and Frequency Re lay will1 Numeric al Communicable type (for 1/C VCB). · 1 No. Master Trip Relay. : 1 No. Tnp circu it healthy relay.
No
1
Alarm & annunciation Schemes for each VCB : : Common Alarm Schem e. : Hooter. : Annunciation panel with 6 annunciation w indows. PARTICULAR REQ UIREM ENTS FOR VACUUM CIRCUIT BR EAKERS Heater SOW, 230V AC : Power socket 230V AC
.2 NOS :1 No : All the internal wiring and interlocks to the breaker panel sha ll be factory compl eted . The breaker and pane sha ll conform to releva nt I S specification s (latest edition). POWER PACK: Power pack wi1h 220 Vo lt AC input & 24 Volt DC con tinuous ou tpu t suitable for closing/ tripping/ indication of the HT panel board with 3 VC Bs: as required.
-
1.5 HT CABLE & TE RMINATI ON: 1.5 .1 S.I.T.C. 11 KV (E) grade XLP E ca ble con forming to I S : 7098 (Part 11) , 1985 with stranded a luminium co nductor, ar moured, PVC Ol,(er-all insulated : conductor size : : 3 C x 240 sq. mm. A2XFY cable. S UB TOTAL H. T. SYSTE M (NON S CH. ITEMS)
I
159404 5.00
r-
,ff. ~ q ' l tj'O
.
~
1450 1000 800 50
M2 M2 M2 M2
689.00 845.00 954.00 1194.00
999050.00 845000.00 763200.00 59700.00
28
Sqm
6751.00
189028.00
40
Sqm
3838.00
153520.00
8
M2
8228.00
65824.00
1
M2
5314.00
531 4.00
4
Sqm
5142.00
20568.00
15 30
Sqm Nos
6700.00 6223.00
100500.00 186690.00
82 1.00
82100.00 7954213.00
~
100
M2
•
(40 oil seperators pressure relief devices ,filter drier moisture indicators.refrigerant economisers and complete operating charge of both refrigerant 134a & compressor oil.control safeties and diagnostics display.refrigerant pi ping.mounting baseframe etc. complete as per the specifications and the drawings of 265 TR Cooling capacity: Operation Parametres : Chiller· Water Temperature IN - 54 F Water Tem perature OUT - 44 F - 0 .0005 FPS Fouling Factor Condenser: Water Temperature IN - 90 F Water Temperature? OUT - 97.5 F Fouling Factor - 0 .001 FPS The cost of BMS compatibl e card shall be included in each chiller)
''j
/
'i
"#'
-
.'
lkwiTR of the chilling machine at full load shall not exceed 0.67 and COP shall at least be 5.85 (including one chilling machine as standby) 20.12.1
a)
NOSR
b)
NDSR
c)
NDSR
Water ci rculation Pumps : Supply.installation .testing and commissioning of centrifugal inline pumps complete with close coupled electric motor duly factory mounted on a common base frame with all accessories for recircu lation of chilled/hot/condenser water for the air-conditioning/heating system.All pumps shall be The pump motor shall be EFF1 type and suitabl e for 415_ +10% 50cycles, 3 phase power supply.The qoute-0 rates shall be inclusive of its insulation and cladding on chilled water and hot water pumps. Pump performance characteristics shall be as follows as per drawings and speci fications. Ch illed wa t er Primary Pumps Water flow Rate : 636US GPM Head : 12 m ( Including one standby) Chilled water secondary Pumps with control panel & VFDs 1DPT and PLC with duly downloaded software Water flow Rate : 636US GPM 11ead : 15 m ( Including one standby) Condense r water Pumps (insulat ion,cladding not requi re d on these pumps) Water flow Rate :1050US GPM : 23m Head ( Including one standby) Cool ing Tower s :
3
Nos.
4954084.00
14862252.00
3
Nos.
285424 .00
856272.00
3
Nos.
385243.00
1155729.00
423743.00
1271229.00
-
20.13.1
NDSR
..
to
3
Nos.
(ijs=) Supply, installation, testing and commissioning of FRP constructi on Induced draft Cross now type Cooling towers, Each tower shall be complete with FRP cold water basin, honeycomb design PVC fill, Casing, Hot water distribution system, ladder,2 nos of 5.5. kw axial flow fan with statically/dynamically balanced belt & pully drive, coupled with TEFC, EFF-1, Class F Insulation, tP55 indL1ction motor suitable for 415±10% volts. 50 Hz, 3 phase power supply. Basin shall be provided with accessories like quickfill, makeup & dra in , brass construction float valve, overflow pipe etc. Separate motor shall be provided in each cell of multi cell towers. Tower shall be selected on the basis detailed in the schedule. Tower shall be suitable for outdoor installation next to occupied areas as per drawings and specifications:
•
I a) NDSR 20.14.1
325TR (CT water in 97 .5 F/ CT water ou t 90 F) ( Including one standby) Floo r m ounted Air Handling Units : Supply,installation,tcsting and commissioning of sheet metal sectionalised construction draw th ru type AHUs in Double Skin construction. Each Air Hndling Units shall be with filters sections with prefilters ,chilled water cooling coils of Copper tu be and Alumin ium fins construction.squirrel cage induction EFF1 type motor.backward curved centrifugal/Plug fans.bell/direct drive and vibration 1solators,rnixi ng box ,coil size shall be selected for face velocity of 500 FPM. static shall be 60 mm.Motor shall be suitable for 41 5V/3Ph/50 Hz AC
3
Nos
684594 00
2053782.00
1 2 1
Nos. Nos. Nos.
618529.00 535909.00 262372.00
618529.00 1071818.00 262372.00
2 2
No No No No No No
179753.00 175287.00 159656.00 102716.00 90434.00 89318.00
359506.00 350574.00 638624.00 102716.Q{) 90434.cm 89318.00
Air moving capacities shall be as detailed below as per drawings and and specifications.{AII these AHUs shal l be with thermal break profile) a) b) c)
NDSR NDSR NDSR
20.15.1
,
a) b) c) d) e) f)
NDSR NDSR NDSR NDSR NDSR NDSR
18,000 cfm with 4 row cooling coil 15,500 cfm with 4 row cooling coil 6000 cfm with 6 row cooling coil Ceiling Suspended Air Hand ling Units : Supply,installation,testing and commissioning o f sheet metal sectionalised construction draw thru type AHUs in Double Skin construction. Each Air Hndling Units shall be with filter section with prefilters ,chilled water cooling coils of copper tube & Al. Fins construction.squirrel cage induction motor.cen trifugal fans and vibration isolators ,mixing box belt drive and vibration isolators .Coil size shall be selected for a max. face velocity of 500 FPM and sta tic shall be as Motor shall be suitable for 415V/3Ph/50Hz AC supply. Air moving capacities shall be as follows as per dray,iings and specificalions.(AII these AH Us shall be with thermal break 6,300 cfm with 4 row cool ing coil (with prefilters only /40 mm 6,000 cfm with 4 row cooling coil (with prefilters only /40 mm 5,700 cfm with 4 row cool ing coil (with prefilters only /40 mm 3,000 cfm with 4 row cooling coi l (with prefilters only /40 mm 2.500 cfm with 4 row cooling coil (with prefilters only /40 mm 2,200 cfm with 4 row cooling coil (with prefilters only /40 mm Exhaust Air Fan Sections
ihv:_rr. R17.ffi ~o "110 ·x1a Mo f'"u ~m fctqtf ~!f ~{tr,:{, ~
4 1 1 1
,;·
1,i
(40 -
.1
!"'
v a) b) c) d)
1 1 1 1
No No No No
1674 72.00 167472.00 128395 .00 104949.00
1674 72.00 167472.00 128395.00 104949 .00
4 8 7 2
Nos. Nos. Nos. Nos.
558239.00 558239.00 535909.00 279120.00
2232956.00 4465912.00 375136300 558240.00
4
Nos.
4785.00
19 140 .00
1
No
26 1250 .00
26 1250.00
a
12.0 TR Actual Cooling Capacity & 11 000 CMH circulation air quantity draw through type Chi lled Water Operated Vertical Zone Air Conditionin g Units with all necessary Chilled Water Coils. Microprocessor Based Controller, Con trol Valves, Filters. Variable Speed Fans and Motors, Controls etc.
27
Nos
1177095.00
3178 156 5.00
b
Plant Watch Pro ( complete monitoring and software integrated to all Underfloor air conditioni ng systems). (One for Each Area)
5
Nos.
396773.00
1983865.00
NDSR NDSR NDSR NDSR
20.17.1
a) b) c) d) 20.1 8. 1
NDSR NDSR NDSR NDSR
a)
NDSR
20.19.1
NDSR
a)
20 .20.1
Supply,1nstallation ,te sting and commissioning of Exhaust air fan fan section with backward curved fans and motor.drives set, trame,in double skin construction and complete in all respect as specifications and drawings of following capacities as per drawings and specifications 14000 cfm at 50 mm sta tic(For Kitchen exhaust) 11400 cfm at 50 mm sta tic(For Toilet exhaust) r 200 cfm at 50 mm static(For T oilet exhausl) 6300 cfrn at 50 mm sta lic(For Toilet exhausl) Ax ial fl ow E/A Fan : Supply.installation.testing and commissioning of Axial flow type Fans complete with motor with suitable Electric starter panels . It should be complete as per m anufacturer's specifications Axial Fans are of the following capacities : 55,000 cfm at 30 rnrn stutic (for basement areas Emergency 53,000 cfm at 30 mm static (for ba sement areas Emergency 50,000 cfm at 30 mm sta tic (for basement areas Emergency 29,000 cfm at 30 mm static (for basemen t areas Emergency Supply,installation, te sting and commissioning of Propeller type free discharge exhaus t fans complete with motor , fan ,exhaust Louvers as per drawings and specifications. 225 mm dia Ai r wash er : Supply,installalion,testi ng and commissioning of Double skin lype cell ulose paper fi ll airwasher . Ai1washer shall be factory assembled Double skin type complete with SS water tank pump,DIDW centrifugal fans.electric motor, celdek fill ing and water distribution header.Galvanised Iron (GI) piping with valves and fittings between airwasher and Pumps.The air moving capacities shall be as follows as per drawings and the specification s 12500 cfm at 50 mm static Supply of Under Fl oor Coo ling System along with accessories as per the following details of work of GEA Denco make as per below details :
NDSR
The Zone Air Con ditioning Unit will be mounted on a rigid base frame of·steel o f height to suit the raised modular fl oor i nstallation.T he width and length of the base frame will be selected to suit the size of the Zone Air Conditioning Unit. The cabinets will be attracti ve ly designed having, beveled corners with flu sh fitting panels. Units will have a rigid frame , manufactured from non corroding hinged front panel(s) to provide access for installation and servicing. Panel s shall be lined with class "O" non eroding insulation material with both thermal and acoustic properties.
~ tjlf~~ \iO go ~fl ~m R-ro fc;Jo ~ s,r..1il~ >i(tmf. ~
"'
..
--
!
• j
l
(fii) Zone Units be fitted with the low velocity filters. Filters to have an efficiency of 30% ASHRAE 52/76 Eurovent arrestance value 90% (G4). They shall be fitted in the return air stream. These filters shall be fitted in the return airside of the Zone Unit within the main cabinet.Filters will be held by a quick release retaining niechanism and be accessible from the front of the unit.A differential pressure tra11sd ucer shall be fitted which, through the alarm facility in the microprocessor controller, shall indicate when the filters need changing . A differential pressure transducer shall be fitted to monitor filter condition; hiy~, differential pressure will result in an ala,m. The Zone Units will be fitted with either two, three or four EC, Fan motor ( Electronic Commutated Type), d.A differential pressure transducer will be fi tted to monitor airnow; failure of said airflow will res ult in an alarm and automa tic disabling o f all unit functions. Fan motor speeds will be variable and dependent upon return air conditions. The fans will automatically modulate dependent upon return air conditions and will have an easily resettable upper and lower fan speed limit for cooling/heating modes.A low speed shall be assigned for dehumidification mode.The fan speed limits wi ll be easily modified on site to suit new site condition. Tt1e coils will be multi-row, constructed from 3/8" 0/D copper tubes wi th mechanically bonded aluminium fins. The coil face area shall be maximised to ensure high sensible heat ratio and lov, a1rside pressure drop, thereby minimising fan power and noise level. A drain tray shall be included to ensure efficient removal of the condensate, via a factory fitted trap.Units will be fitted with e 2 way m odulating valve having manual override facility with water pressure f temperature test points, and these com ponents shall be housed in the right hand end of the lr,:,hinet The electrical switchgear shall be contained in a cubicle located in the top of the unit, and shall include: Controller baseboard and interface cards ,MCB's and con tactors for fans, heaters and humidifier as appropriate.All electrical components shall be supplied and fitted by th e Underfloor Air Conditioning System manufacturer.Cabling shall be colour coded and numbered. and neaily run in trunking segregating high and low voltages. All wiring shall comply with BS EN 60204 Part 1.Auxiliary con\rol ci rcuits shall be 24 Volt. The electrical section shall be isolated from the air stream and accessible from the front of the unit.The electric board shall essenti ally include swi tch, transformer, safety automatic switches, fan motor contact, fa n motor speed controllers, additional contacts for r emote signaling etc.The unit will be provided with mains electrical disconnect switch.
.
l
--
~)
)l
All Zone Units will be fitted with an advanced tpuch sctreen type carel pco5 microprocessor controls system. designed and installed by the Underfloor Ai r Conditioning System manufacturer.The controls will provide maximum economy of operation, a comprehensive intelligent alarm system and a wide range of information for operators and service en gineers. All information will be presented in a user friendly format with tamper-proof setting up arrangements. The Zone Air Conditioning Unit will be capable of being networked to Local Env11 ornnental Control Units. Interrogation and control of manufacturer defined parameters will be capable from a central monitoring/control station(s) or via the Building Management System
i
~
Provide adequate Local Environ mental Control Units ( LECU's) lo achieve the design conditions. Units will be an intelligent fan tile, easily positioned anywhere in the raised modular floor.The Unit will be capable of being installed into the raised modular lloor wi thout the need or any stringers being supplied and 111stalled by U1e raised modular floor provider. The unit will be fitted with a fully modulating internal damper.The unit will be supplied with 2 No. Supply/Re-circulation Grilles.The unit will be designed and manufactured so as to occupy the space of a single 600mm x 600mm raised modular floor tile.The unit will be capable of being removed from a standard raised modular fl oor without the necessity of removing any other adjacent floor tiles.All user enable adjustment, fan speed and temperature setpoint, will be adjustable by the user. An optional hand held, battery powered, infra red remote controller maybe utilised.(0.10.2 m3/sec air flow capaci ty)
20.21.1
NOSR
306 The unit body will be cons tructed from polycarbonate, ABS, acrylic or PVC and shall have lire retardant properties. The body shall be machine vacuum formed.The unit will be 225mm overall in depth, when measured from the underside of the raised modular floor. The damper will be fitted with a fully modulating electrically operated actuator, which under the dictates of the onboard controller opens or closes the damper to allow air from the void to be drawn into the room. The damper will be fully modulating between the open and closed positioned.The modula ting damper will incorpora te non adjustable bleed, lo allow a permanent air bleed from the floor void in order to ensure a continuous fresh air supply to the room during conditions where the damper is fully closed.
.
~
~-atf1l n. .....n .JO ~o ~o f.:Io ~T\> ~n ~tt ~-nf ~~. ~c1ir.
'
'
Nos
11 903 1.00
36423486.00
Tne unit fan will comprise of a single Crossflow fan . s'ow sµeed design with perforated guide vane.The Crossflow fan will have forward curved blades terminating in end plates, and be partially surrounded by a perforated guide vane and curved body. During rotation the flow of air passes through part of the rotor blades into the rotor, creating an area of turbulence which. working with the guide system, deflects the air flow through another section of the rotor into the discharge duct of the fan casing. Fan to be fitted with maintenance free speed controllable external rotor motor. Fan to be filled with grooved ball bearings. lmpellor mounting with rubber elemen ts to reduce vibration.Fan to provide various separate fixed fan speeds that can be easily set by users or variable speed backward curved EC motor option also if there is a requirementand customisation is needed or mix of these two fans .
(49) .._____........
Two sliaight bar alum1n1urn grilles will be mounted on top of the unit, flush with the raised floor and will be designed for the general office environment. These grilles provide supply and extract air to the room.Each grille will be 200mm x 600mm and be supplied lo fit flush to the raised floor and finishes. Each grille will incorporate height adjustment to enable levelling to site specific floor tile and finish thickness.lnstatlling contractor to ensure supply of raised modular floor tile infills to be fitted between the unit grilles
1 he urnt v1ill be fitted , by the Underfloor Air Conditioning System manufacturer, with a three metre supply cable and plug.The unit will be supplied with a 2 No. network sockets, to enable connection of Local Environmental Unit networking cables.Each unit will be provided with a 5 metre network cable, for installation on site.The unit will be supplied complete with 2 No. tempera ture sensors. These sensors will be located in the unit so as to accura tely monitor local room temperature and underfloor plenum air temperature. All Local Environmental Control Units will be f itted by an advanced microprocessor con troller. T he controller will control all functions of the unit. Cooling: When the unit room sensor detects that the local temperature is too warm, the unit controller will interrogate the underfloor sensor. If the underfloor temperature is below that of the room air, the unit damper will modulate open to allow cooler air to the space. The damper will modulate sufficiently to offset t11e heat gain to the space
.
\JO
\'.Jlf-{ ~
284680.00
BOQ OF TAJ ORIENTATION CENTER, AGRA SL.
3
Unit
ITEM OF WORK
NO
Qty.
AMOUNT (Rs.)
Rate (Rs/unit)
Remarks
NON SCH. ITEMS DIESEL GENERATING SYSTEM S.I.T.C. 500 KVA, 415 V, 3 ph, 50 Hz Radiator cooled diesel generator (D G set) used for standby electrical energy generation. The D G Set shall be SILENT type conforming to the latest CPCB norms and shall comprise of: DIESEL ENGINE : . Vertical. multi-cylinder diesel engine of suitable b hp conforming to IS 10002, Turbo charged type, Electronic Governer Air cooled with water cooled radiator.
. '
ALTERNATOR: Directly coupled alternator conforming to IS: 4 722 generating 415 V, 3 phase, 50 Hz, power, Fly-wheel , Common base-frame. Suitable anti-vibration pads of required quantity & size, Silencer shall be residential type, Fuel tank (Day tank) suitable for eight hours operation - complete with fuel level indica tor, filler cap, drain valve etc .. Electrical starting and control equipment for electrical starting of D. G. Set with: : Battery charger. : Heavy duty battery set. Battery shall be suitable for at least 3 successive cold starts. Control Panel for control , monitoring & protection of
D G.Set.
NOTE: As per the Government notification, D G Setshall be enclosed in a canopy meeting the specified NORMS for sound pollution. ( Please Check with ADA also for Deisel Set useage, as it is a World 3. 1 heritage zone) 3.2 0 . G. EXHAUST SYSTEM : Supply of 200mm diameter MS Black Pipe, 4.85mm thick, complete with Bends & Flanges as required. a.
b.
: Supply of the rmal Insula tion on exhaust pipe with Mineral Wool 50mm Thick wire mesh and 26 gauge aluminium cladding
13539196.00
No.
4
3384799.00
Mtrs.
32
3407.00
109024.00
Mtrs.
32
2032.00
65024.00
114.00
570000.00 167640.00
Kg .
5000
· Supply of Alumi nium cladding for the residential silencers
No.
8
e.
: Supply of SS Flexible Belows
No .
8
20955.00 20955.00
3.3
4
44450.00
177800.00
a.
FUEL PIPING between Day tank & Engine · Supply & Installation 990 Liter Capacity Day oil fu~I tank fabricated from 2mrn thick MS Sheet complete w ith fuel level indicator and lower & upper level fuel control system.
394.0 0
47280.00
b.
: Supply & Install ation of MS Pipe 25 mm with Bend s, flanges packing Mtrs. as required.
c. 3.4
: Supply & Installation of set of Fuel Pipe fittings like valves. tee, elbows etc. as required. D. G. AM F WITH LOAD MANAGEMENT PANEL
25400.00
101600.00
c.
ct.
Supply of MS Support for exhaust piping.
MR
167640.00
, ~
.... No.
.
Set
120 4
MR
•
v
/
S.I.T.C of D G AMF W ITH LOAD MANAGEMENT PANEL: Au tomatic mains failure panel with load management arrangement (AMF-LM) for 2 x500 KVA DG sets with the Mains feeders. The Panel s hall be self stand ing, made of Sheet steel (2 mm for doors & 1.6 mm other faces), s urface treated with 7 tank process and painted with anticorrosion painl/powder coated. The enclosure shall be IP 52 protected as per I S: 2147. : The controls of the AMF panel and the load management sequence, as per the SLD, shall be PLC control based. The mains fa ilure shall be sensed on incoming s ide of mains contactor and initiate the starting cycle of D G s et after an adjustable 0-6 sec delay The switch over of power between the Mains power and the D G Power shall take place with suitably sized (EDO) ACBs in the AM F Panel. After the D.G set has started, on restoration of mains power, D.G set s hall continue to run for an adjustable time of 0-10 minutes before switc hing back to mains power. : The components in the AMF panel shall be as follows:
(6:
...
All ACBs shall have: Inbuilt TRIP LED indication. lcs = lcu = lcw for 1 sec.for the breakers with built-in microprocessor based releases , : Adjustable over current with time setting, short circuit w ith time setting, earth fault with time setting. : R,Y,B phase indication lamps (LED Type) with Control MCB I MPCB as per fault requirement. : Instantaneous short circui t A ll MCCBs sha ll have· · lcs =lcu = 100% for the breakers . . MCCB's upto 250A shall be w i1h thermal - magnetic releases and beyond 250A shall be with micro-processor based releases. : MCCB's shall be with extended rotary handle. (EDO) ACBs shall be as per SLD as follows with req uired con trols: : 41 5 V, 50 Hz, 800 A, 4Pole (EDO) ACB : 5 Nos. · 415 V, 50 Hz, 800 A, 4Pole Isolator (O ff Load) 2 Nos. BUS BARS. : 800A TP + N Aluminium suitable for 1.1 KV with a fault level with-stand: 20 KA for 1 second in two parts as per SLD. The Earth Bus shall be of CU & run contnuously throughout the width of the panel.
.
: Protection of the feeders as required. : All controls. Annunciations and indications for safe and trouble-free operation of the D G Set. : The operational sequence shall be PLC controlled as per the scheme in the SLD.
.
~
,,)
: Dual Source Energy Meter with MDI suitable for 1600 KW. : C lass B+C surge arrester w ith nominal discharge current(ln as per IEC 61643-1) 30KA (for 8/20rns) & Impulse current 7KA( for 10/350ms) between ph ase to neutral. & 50KA (8120rns) impulse current for neutral to earth. Maximum continuous operating voltage shall be 320V Response time (ta) s11all be less than 25ns for phase to neutral. Voltage pro tection level shall be less than 900V at SKA (8/20ms) for phase to neutral & 1.2KV for neutral to earth. (080 Bettermann make or equivalent). : 1 No.
I~
No SUB TOTAL OG SYSTEM (OG Sets+AMF-LM)
-t7~,o rcto f'~(i ~l ~ ~PT,/. ~c"Ffl
,
•