Preview only show first 10 pages with watermark. For full document please download

Bos 21m-pa-ie10-s4 Ordering Code: Bos00wt

   EMBED


Share

Transcript

PNP (2x), NO-NC (pins 4-2) Infrared DC, direct current BOS 21M-PA-IE10-S4 Ordering code: BOS00WT Through-beam sensor Series 21M Working Range: 0...20 m 1) Optical axis, 2) Display and control panel, 3) 270° rotatable Characteristic data Operating voltage Connection Switching freq. f max. Indicator Setting Adjuster Reference emitter Short-circuit protected Protected against polarity reversal Protected against reverse connection Degree of protection as per IEC 60529 Protection class 10...30 V DC Connector, M12x1-S04 500 Hz Stability - LED GN Sensitivity (Sn) Potentiometer 270° (1x) BOS 21M-XT-IS11-.. yes yes yes IP67 II Optical data Principle of optical operation Switching function, optical Light type Ambient light max. Receiver NO dark-on - NC light-on Infrared 10,000 Lux Electrical data Rated operating voltage Ue DC Effective operating current Ie Internet Balluff Germany Balluff USA Balluff China 24 V 100 mA : www.balluff.com : +49 (0) 7158 173-0, 173-370 : 1-800-543-8390 : +86 (0) 21-50 644131 Rated insulation voltage Ui Ready delay tv max. Utilisation category Load capacitance max. (at Ue) Off-state current Ir max. Ripple max. (% of Ue) Switching output Switching function Turn-off delay toff max. Turn-on delay ton max. No-load current max. Io at Ue Voltage drop Ud max. (at Ie) 75 V DC 200 ms DC 13 1 µF 10 µA 8% PNP (2x) NO-NC (pins 4-2) 1 ms 1 ms 35 mA 2V Mechanical data Connector type Eff. switching distance Sr Shock rating Vibration rating Ambient temperature Degree of contamination Sensing surface material Housing material Surface protection Mounting type M12x1-S04 20000 mm Half-sinus, 30gn, 11ms, 3x6 10-55 Hz, 1 mm ampl., 3x30 min -25...55 °C 3 PMMA GD-Zn, aluminum Powder coated Screw M4 1 (2) Print date: 05.10.2012 Selection date: 05.10.2012 PNP (2x), NO-NC (pins 4-2) Infrared DC, direct current BOS 21M-PA-IE10-S4 Ordering code: BOS00WT Through-beam sensor Series 21M Working Range: 0...20 m Design Operating range Ro Range Sn Block, rotatable connection 0...20 m Sn = 20 m, adjustable Basic data Basic standard IEC 60947-5-2 The sensor is functional again after the overload has been eliminated. Operating object (test target): Gray card, 200 x 200, lateral approach With connector, e.g. BKS-S 20-… total length = switch length +18 mm. For ESD hazard: Operate device using shielded cable. Only for NFPA 79 applications (machines with a supply voltage of maximum 600 volts). Device shall be connected only by using any R/C (CYJV2) cord, having suitable ratings. For additional information, refer to user's guide. Order accessories separately. Definitions see main catalog subject to change 1) Output function 2) Stability 3) Sensitivity Internet Balluff Germany Balluff USA Balluff China : www.balluff.com : +49 (0) 7158 173-0, 173-370 : 1-800-543-8390 : +86 (0) 21-50 644131 2 (2) Print date: 05.10.2012 Selection date: 05.10.2012