Transcript
GUIDE SPECIFICATIONS EC Series 6-30 Large Commercial R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Heat Pump, Ground Water Heat Pump and Ground Loop Heat Pump applications for units up to 10 tons. Units intended for use on ground loop applications shall have an optional extended range package installed which consists of an insulated water to refrigerant heat exchanger. Units shall be Underwriter Laboratories (UL and cUL) listed for safety on all models. Each unit shall be run tested at the factory. Each unit shall be pallet mounted and stretch wrapped. The units shall be manufactured in an ISO9001:2000 certified facility. The units shall be designed to operate with entering fluid temperatures between 50˚F (10˚C) and 100˚F (38˚C) in cooling and between 50˚F (10˚C) and 80˚F (27˚C) in heating. With the optional factory installed extended range package units shall operate with entering fluid temperatures between 50˚F (10˚C) and 110˚F (43.3˚C) in cooling and between 25˚F (-3.9˚C) and 80˚F (27˚C) in heating. CASING & CABINET The cabinet shall be fabricated from heavy-gauge galvanized steel. The interior shall be insulated with ½” (12.7mm) thick, multi density, coated, glass fiber. All units shall allow sufficient service access to replace the compressors without unit removal. Two blower and two compressor compartment access panels shall be removable with supply and return ductwork in place. A duct collar shall be provided on the supply air opening of all vertical units. Units shall have a 1 inch thick throwaway type glass fiber filter as standard. The filter rack shall incorporate a 1 inch duct flange. Vertical units shall have an insulated divider panel between the air handling section and the compressor section to minimize the transmission of compressor noise, and to permit operational service testing without air bypass. Units shall have stainless steel condensate drain pan(s). REFRIGERATION CIRCUITS Units shall utilize refrigerant R-410A. All units shall contain sealed refrigerant circuits including hermetic compressors, thermal expansion valve metering devices, refrigerant drier, finned tube air-to-refrigerant heat exchangers, refrigerant reversing valves and service ports. Compressors shall be high efficiency, designed for heat pump duty, internally spring isolated (except for scroll type compressors) for maximum sound attenuation and mounted on rubber vibration isolators. Compressor motors shall be equipped with overload protection. Refrigerant reversing valves shall be pilot operated sliding piston type with replaceable encapsulated magnetic coils energized only during the cooling cycle. The finned tube coil shall be constructed of lanced aluminum fins not exceeding fourteen fins per inch bonded to rifled copper tubes in a staggered pattern not less than three rows deep and have a 600 PSIG (4140 Kpa) working pressure. Coils shall have a baked polyester enamel coating for protection against most airbourn chemicals. Coils shall have aluminum end sheets. The coaxial water-to-refrigerant heat exchangers shall be constructed of a
convoluted copper (optional cupro-nickel) inner tube and steel outer tube with a designed refrigerant working pressure of 600 PSIG (4140 Kpa) and a designed water side working pressure of no less than 400 PSIG (2750 Kpa). FAN MOTOR & ASSEMBLY(S) The fan(s) shall be belt driven DWDI forward curved type with dynamically balanced wheel(s). The housing(s) and wheel(s) shall be designed for quiet low velocity operation. The fan housing(s) shall be removable from the unit without disconnecting the supply air ductwork for servicing of the fan motor(s). The fan motor(s) shall be 1725 or 3450 RPM 56 frame sealed ball bearing type. The motor(s) shall be permanently lubricated and have thermal overload protection. ELECTRICAL Controls and safety devices will be factory wired and mounted within the unit. Controls shall include fan relay(s), compressor contactors, 24V transformer, reversing valve coils and a solid state lock-out control circuit (UPM). The UPM controller shall include the following features: Anti-short cycle time delay, random start, interstage delay, brown out/surge/power interruption protection, 120 second low pressure switch bypass timer, shutdown on high or low refrigerant pressure safety switch inputs, shutdown for the optional freezestat or high level condensate sensors, 24 VAC alarm output for remote fault indication, unit reset at thermostat or disconnect, ability to defeat time delays for servicing, time delay between stages and automatic intelligent reset. The UPM shall automatically reset after a safety shut down and restart the unit, if the cause of the shut down no longer exists, after the anti-short cycle and random start timers expire. Should a fault reoccur within 60 minutes after reset, then a permanent lockout will occur. A light emitting diode (LED) shall annunciate the following alarms for each refrigerant circuit: high refrigerant pressure, low refrigerant pressure, low water temperature and a high level of condensate in the drain pan (when equipped with the optional low water temperature and high level condensate sensors). The LED will display each fault condition as soon as the fault occurs. If a permanent lockout occurs, then the fault LED will display the type of fault until the unit is reset. Safety devices include a low pressure cutout set at 40 PSIG (280 Kpa) for loss of charge protection (a freezestat used for loss of charge protection is not acceptable) and a high pressure cutout control set at 600 PSIG (4140 Kpa). An optional energy management relay to allow unit control by an external source shall be factory installed. PIPING Supply, return water and condensate drain connections shall be copper or brass female pipe thread fittings and mounted flush to cabinet exterior.
ECSPECS.P65 REV: 05-11
38.00 40.00
Return Air Opening D(Duct Flange) 38.00 38.00 E(Filter Rack) 40.00 40.00
Notes:
Service Access Access To: Controls, Compressors, Refrigeration Components Blower & Motor Blower
Top Supply (FBT)
Rear Return
Front Return Standard Blower Orientation
ECSVDGIP.P65
Front Supply (FBF)
Standard Blower Orientation
Top Supply (FFT)
Optional Blower Orientation (979-032)
Rev. 5-11
Optional Blower Orientation (979-032)
Rear Supply (FFR)
Single Blower Large Commercial Units
EC072-120 Vertical Dimensions
Condensate connections are 0.75" FPT on -072 through -120 Due to continuing research and development, specifications are subject to change without notice.
Panel # 1 2 3
Replacement Filter Size -072 through -120 20 x 34-1/2 x 1 (2 per unit)
15.00 9.00 3.00 1.50"
-120 62.00 42.00 32.00
Condenser Connections A 14.75 14.75 B 8.50 8.50 C 2.75 2.75 Dia. (FPT) 1.00" 1.00"
-096 62.00 42.00 32.00
Height Width Depth
-072 62.00 42.00 32.00
Model
Dimension
All Dimensions +/- 0.125"
Dimensions
FHP Manufacturing Co. 601 N.W. 65th Court Fort Lauderdale, FL 33309 Phone: (954) 776-5471 Fax: (800) 776-5529 http://www.fhp-mfg.com
48.00 50.00
Return Air Opening
1.50"
Notes:
1 2 3
48.00 50.00
1.50"
24 x 24 x 1 (4 per unit)
Top Supply (FBT)
Rear Return
Front Return
ECSVDGIP.P65
Front Supply (FBF)
Standard Blower Orientation
Rev. 05-11
Optional Blower Orientation (979-032)
Rear Supply (FFR)
Standard Blower Orientation
Top Supply (FFT)
Optional Blower Orientation (979-032)
Single Blower Large Commercial Units
EC151-181 Vertical Dimensions
Condensate connections are 0.75" FPT on -151 through -181 Due to continuing research and development, specifications are subject to change without notice.
Controls, Compressors, Refrigeration Components Blower & Motor Blower
Service Access Access To:
-151 through -181
Panel #
-181 70.00 52.50 32.00
Replacement Filter Size
(Duct Flange)
Dia. (FPT)
(Filter Rack)
-151 70.00 52.50 32.00
Model
Condenser Connections
Height Width Depth
Dimension
All Dimensions +/- 0.125"
Dimensions
FHP Manufacturing Co. 601 N.W. 65th Court Fort Lauderdale, FL 33309 Phone: (954) 776-5471 Fax: (800) 776-5529 http://www.fhp-mfg.com
A B C
J K L
2.00 24.00 22.00
Return Air Dimensions 2.00 2.00 2.00 20.50 20.50 20.50 18.50 18.50 18.50
Condenser Connections 24.00 27.50 26.25 28.00 2.75 3.38 3.50 2.75 24.00 28.00 28.00 28.00 17.75 16.75 19.25 14.50 1"FPT 1.25"FPT 1.50"FPT 1"FPT
Panel# 1 2 3
Service Access Access To: Controls, Compressors Blower & Motor Compressors, Refrigeration Components
Replacement Filter Size 20 x 34-1/2 x 1 (2 per unit) 24 x 34 x 1 (2 per unit)
Supply Air Dimensions (Blower Outlet) 18.50 12.50 15.50 15.50 16.00 13.50 13.50 13.50 14.00 5.25 10.50 10.50
072-120 150
E F G H Diameter
-096 21.50 38.00 78.00
-150 26.75 42.00 82.00
Dimension -072 21.50 Height 38.00 Width 78.00 Depth
Model -120 21.50 38.00 78.00
All Dimensions +/- 0.125"
Dimensions
FHP Manufacturing Co. 601 N.W. 65th Court Fort Lauderdale, FL 33309 Phone: (954) 776-5471 Fax: (800) 776-5529 http://www.fhp-mfg.com
120 (-SLS Only) Notes: All condensate connections are 0.75" FPT. Due to continuing research and development, specifications are subject to change without notice. ECLHDGIP.P65
072, 096 & 150 (-SLS Only)
EC072-150 Horizontal Dimensions
Rev. 05-11
EC242 SLS CONFIGURATION ONLY
Dimensions
Replacement Filter Size EC180 24 x 34 x 1 (2) EC242 17 3/4 x 34 3/4 x 1(2)
Condenser Connections EC180 1.50"FPT EC242 2.00"FPT
Rev.05-11
Service Access Panel# Access To: 1 Controls, Compressors, Refrigeration Components 2 Blowers & Motors 3 Compressors, Refrigeration Components
EC180 SLS CONFIGURATION ONLY
EC180-242 Horizontal Dimensions
Notes: All dimensions +/- 0.125". All condensate connections are 1.25" FPT. Due to continuing research and development, specifications are subject to change without notice. EC180242HZIP.P65
FHP Manufacturing Co. 601 N.W. 65th Court Fort Lauderdale, FL 33309 Phone: (954) 776-5471 Fax: (800) 776-5529 http://www.fhp-mfg.com
Height 38.00 38.00 38.00 58.00
E
Controls, Compressors, Refrigeration Components Blower & Motor Blower
Rear Return Front Supply (FBF)
Front Return Top Supply (FFT)
Optional Blower Orientation (979-033)
ECDVDGIP.P65
Standard Blower Orientation
Standard Blower Orientation
Front Return Rear Supply (FFR)
Rev: 05-11
Rear Return Top Supply (FBT)
Optional Blower Orientation (979-033)
Dual Blower Large Commercial Units
EC210-360 Vertical Dimensions
Due to continuing research and development, specifications are subject to change with out notice.
1 2 3
Service Access Access To:
20 x 34-1/2 x 1 (4 per unit, 210-360) 30 x 34-1/2 x 1 (4 per unit, 360)
Recommended Replacement Filter Size (Nominal)
11.0
Optional Blower Orientation
Panel #
1.25"FPT
1.25"FPT 1.25"FPT 1.25"FPT
Supply Air Duct Collar Location (F)
2.00"FPT
40.00 40.00 40.00 60.00
D
Condensate Drain Diameter
2.75 2.75 2.75 3.50
C
6.00
360
2.00"FPT 2.00"FPT 2.00"FPT
B
8.75 8.75 8.75 9.00
Condenser Connection Diameter
18.00 18.00 18.00 17.00
A
Standard Blower Orientation
210 240 300
Model
Dimensions
All Dimensions +/- 0.125"
210 62.00 240 66.50 300 66.50 360 86.50
Model
FHP Manufacturing Co. 601 N.W. 65th Court Fort Lauderdale, FL 33309 Phone: (954) 776-5471 Fax: (800) 776-5529 http://www.fhp-mfg.com
EC072
2 STAGE PACKAGED UNITS
SPECIFICATION DATA SHEET
AQUARIUS SERIES
FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS
ELECTRICAL SPECIFICATIONS
MECHANICAL SPECIFICATIONS
Blower Loop Pump Electrical Elect. Compressor (x2) Characteristics Symbol RLA LRA FLA HP FLA HP 208/230-1-60 208/230-3-60 460-3-60
-1 -3 -4
13.0 7.8 3.9
74.0 68.0 34.0
7.0 3.6 1.8
1 1 1
- - -
Refrigerant: R-410A Air Coil Square Rows Tube Fins/ Feet Deep O.D. Inch 7.00 3 3/8 14 Water Coil Type Work Press Coaxial 450 psig Blower Size Compr Type 12x12 BD Reciprocating Net Weight Ship Weight 615 lbs 660 lbs
Min. Max. Circuit Fuse/ Amps Breaker
1 1 1
36.3 21.2 10.6
45 25 15
BLOWER PERFORMANCE Available External Static Pressure (Inches of Water, Gauge. Wet Coil and Filter Included) Motor 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 Sheave Closed - - - - - - - - 2420 2160 1900 1700 1/2 Open - - 2980 2800 2610 2400 2100 1800 - - - - Open 2780 2590 2350 2050 1780 - - - - - - -
FLUID PRESSURE DROP Fluid Pressure Flow Drop (GPM) (FOH) (PSIG) 10 6.0 2.6 12 8.3 3.6 14 11.0 4.8 16 14.0 6.1 18 17.3 7.5
ISO 13256-1 CERTIFIED PERFORMANCE DATA Rated at 2,300 CFM and 16.0 GPM Water Loop Ground Water Ground Loop (Ext. Range Required) Cooling Heating Cooling Heating Cooling Heating Capacity EER Capacity COP Capacity EER Capacity COP Capacity EER Capacity COP 72,000 13.0 92,000 4.5 80,400 18.6 72,400 3.8 75,600 14.2 54,800 3.2
CAPACITY DATA All performance at 2,300 CFM and 16.0 GPM EFT Range (Standard) 50oF to 100oF
COOLING
EFT Range (Ext. Range Option) 45oF to 110oF
HEATING
EFT Range (Standard) 50oF to 80oF
EFT Range (Ext. Range Option) 25oF to 80oF
Entering Entering Sensible Heat Fluid Air Total Sensible to Power of Temp. Temp. Capacity Capacity Total Input Reject EER (oF) (oF) (MBtuH) (MBtuH) Ratio (kW) (MBtuH)
Entering Entering Heat Fluid Air Total Power of Temp. Temp. Capacity Input Abs. COP (oF) (oF) (MBtuH) (kW) (MBtuH)
50o 60o 70o 85o 100o 50o 60o 70o 85o 100o 50o 60o 70o 85o 100o 50o 60o 70o 85o 100o
70 db 61owb o
75odb 63owb
80odb 67owb
85odb 71owb
70.46 67.85 65.23 61.30 57.38 75.50 72.70 69.90 65.70 61.49 82.87 79.80 76.73 72.12 67.51 90.24 86.90 83.56 78.55 73.54
46.54 45.19 43.99 42.43 41.10 55.65 54.03 52.60 50.75 49.16 61.44 59.66 58.08 56.04 54.29 67.29 65.34 63.62 61.38 59.47
0.66 0.67 0.67 0.69 0.72 0.74 0.74 0.75 0.77 0.80 0.74 0.75 0.76 0.78 0.80 0.75 0.75 0.76 0.78 0.81
4.05 4.50 4.95 5.63 6.31 4.07 4.53 4.98 5.66 6.34 4.11 4.56 5.02 5.71 6.39 4.14 4.60 5.06 5.75 6.44
84.29 83.22 82.14 80.52 78.90 89.41 88.16 86.90 85.02 83.14 96.89 95.38 93.87 91.60 89.33 104.37 102.60 100.83 98.18 95.53
17.4 15.1 13.2 10.9 9.1 18.5 16.1 14.0 11.6 9.7 20.2 17.5 15.3 12.6 10.6 21.8 18.9 16.5 13.7 11.4
Units are complete packages featuring 2 stage operation and containing compressors, reversing valve, expansion valve metering devices, and heat exchangers. Also included are safety controls: Overload protection for motors, high and low refrigerant pressure switches and a solid state lock-out circuit. Extended range option includes insulated water coils. Performance based on ARI/ISO rated air flow, fluid flow and voltage. For conditions other than rated, consult the FHP EAD selection software. Due to variations in installation actual performance may vary marginally from tabulated values. As a result of continuing research and development, specifications are subject to change without notice. EC072ip6 mod1 Rev: 05-11
50o 60o 70o 80o 50o 60o 70o 80o 50o 60o 70o 80o
60o
70o
80o
77.46 88.26 99.06 109.87 73.24 83.45 93.65 103.86 68.28 77.79 87.29 96.80
LOW TEMP HEATING
25o 30o 40o 25o 30o 40o 25o 30o 40o
60o
70o
80o
49.46 54.76 65.35 46.79 51.79 61.80 43.65 48.31 57.63
5.59 5.88 6.18 6.47 5.69 5.99 6.29 6.59 5.82 6.12 6.43 6.73
58.38 68.18 77.98 87.78 53.81 63.00 72.18 81.37 48.43 56.89 65.35 73.81
4.1 4.4 4.7 5.0 3.8 4.1 4.4 4.6 3.4 3.7 4.0 4.2
Extended Range Option Required Antifreeze Required
4.86 5.00 5.30 4.95 5.10 5.39 5.05 5.21 5.51
32.88 37.68 47.27 29.91 34.40 43.39 26.40 30.54 38.81
3.0 3.2 3.6 2.8 3.0 3.4 2.5 2.7 3.1
FHP MANUFACTURING COMPANY 601 N.W. 65th Court - Fort Lauderdale, FL 33309 Phone: (954) 776-5471 - Fax: (800) 776-5529 http://www.fhp-mfg.com
EC096
2 STAGE PACKAGED UNITS
SPECIFICATION DATA SHEET
AQUARIUS SERIES
FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS
ELECTRICAL SPECIFICATIONS
MECHANICAL SPECIFICATIONS
Compressors Min. Max. Electrical Elect. Blower Loop Pump (X 2) Circuit Fuse/ Characteristics Symbol RLA LRA FLA* HP* FLA HP Amps* Breaker 208/230-1-30 -1 21.2 113.0 12.3/12.3 1-1/2 /2 - - 60/60 80/80 208/230-3-60 -3 16.1 120.0 5.0/6.4 1-1/2 /2 - - 41.2/42.6 50/50 460-3-60 -4 8.4 60.0 2.5/3.2 1-1/2 /2 - - 21.4/22.1 25/30 575-3-60 -5 6.4 42.0 2.0/2.5 1-1/2 /2 - - 16.4/16.4 20/20 *Vertical units use one 1-1/2 HP motor (first value) while horizontal units use one 2 HP motor (second value)
Refrigerant: R-410A Air Coil Square Rows Tube Fins/ Feet Deep O.D. Inch 9.00 3 3/8 14 Water Coil Type Work Press Coaxial 450 psig Blower Size Compr Type 12x12 BD Scroll Net Weight Ship Weight 765 lbs 815 lbs
BLOWER PERFORMANCE Available External Static Pressure (Inches of Water, Gauge. Wet Coil and Filter Included) Motor 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 Sheave Closed - - - - - - - 2800 2650 2450 2300 2200 1/2 Open - - 3480 3340 3230 3075 2880 2690 2555 2355 - - Open 3110 2965 2835 2615 2460 2275 - - - - - -
FLUID PRESSURE DROP Fluid Pressure Flow Drop (GPM) (FOH) (PSIG) 12 5.7 2.4 14 7.5 3.2 18 11.7 5.1 21 15.5 6.7 24 19.7 8.5
ISO 13256-1 CERTIFIED PERFORMANCE DATA Rated at 2,800 CFM and 21.0 GPM Water Loop Ground Water Ground Loop (Ext. Range Required) Cooling Heating Cooling Heating Cooling Heating Capacity EER Capacity COP Capacity EER Capacity COP Capacity EER Capacity COP 96,000 14.0 116,000 4.8 116,000 20.6 93,200 4.2 104,000 15.4 73,600 3.5
CAPACITY DATA All performance at 2,800CFM and 21.0 GPM EFT Range (Standard) 50oF to 100oF
COOLING
EFT Range (Ext. Range Option) 45oF to 110oF
HEATING
Entering Entering Sensible Heat Fluid Air Total Sensible to Power of Temp. Temp. Capacity Capacity Total Input Reject EER (oF) (oF) (MBtuH) (MBtuH) Ratio (kW) (MBtuH)
50o 60o 70o 85o 100o 50o 60o 70o 85o 100o 50o 60o 70o 85o 100o 50o 60o 70o 85o 100o
70 db 61owb o
75odb 63owb
80odb 67owb
85odb 71owb
104.23 97.96 91.69 82.28 72.88 111.66 104.95 98.24 88.17 78.10 122.54 115.18 107.82 96.78 85.75 133.41 125.41 117.40 105.40 93.39
68.94 65.32 61.89 56.99 52.22 82.38 78.06 73.98 68.14 62.46 90.92 86.17 81.67 75.23 68.97 99.55 94.35 89.43 82.39 75.54
0.66 0.67 0.68 0.69 0.72 0.74 0.74 0.75 0.77 0.80 0.74 0.75 0.76 0.78 0.80 0.75 0.75 0.76 0.78 0.81
5.36 5.82 6.28 6.97 7.66 5.39 5.85 6.31 7.01 7.71 5.43 5.90 6.36 7.07 7.77 5.47 5.94 6.41 7.12 7.83
122.51 117.82 113.12 106.08 99.03 130.05 124.92 119.79 112.10 104.41 141.06 135.30 129.54 120.90 112.26 152.08 145.69 139.29 129.70 120.11
19.5 16.8 14.6 11.8 9.5 20.7 17.9 15.6 12.6 10.1 22.6 19.5 16.9 13.7 11.0 24.4 21.1 18.3 14.8 11.9
Units are complete packages featuring 2 stage operation and containing compressors, reversing valve, expansion valve metering devices, and heat exchangers. Also included are safety controls: Overload protection for motors, high and low refrigerant pressure switches and a solid state lock-out circuit. Extended range option includes insulated water coils. Performance based on ARI/ISO rated air flow, fluid flow and voltage. For conditions other than rated, consult the FHP EAD selection software. Due to variations in installation actual performance may vary marginally from tabulated values. As a result of continuing research and development, specifications are subject to change without notice. EC096ip6 mod1 Rev: 05-11
EFT Range (Standard) 50oF to 80oF
EFT Range (Ext. Range Option) 25oF to 80oF
Entering Entering Heat Fluid Air Total Power of Temp. Temp. Capacity Input Abs. COP (oF) (oF) (MBtuH) (kW) (MBtuH)
50o 60o 70o 80o 50o 60o 70o 80o 50o 60o 70o 80o
60o
70o
80o
99.81 112.12 124.42 136.73 94.37 106.00 117.62 129.25 87.98 98.81 109.63 120.46
LOW TEMP HEATING
25o 30o 40o 25o 30o 40o 25o 30o 40o
60o
70o
80o
67.70 73.73 85.79 64.03 69.73 81.13 59.72 65.03 75.64
6.63 6.91 7.19 7.48 6.75 7.04 7.33 7.62 6.89 7.19 7.49 7.78
77.20 88.53 99.87 111.20 71.35 81.98 92.62 103.25 64.45 74.26 84.08 93.89
4.4 4.8 5.1 5.4 4.1 4.4 4.7 5.0 3.7 4.0 4.3 4.5
Extended Range Option Required Antifreeze Required
5.91 6.06 6.34 6.02 6.17 6.46 6.15 6.30 6.60
47.52 53.06 64.15 43.48 48.69 59.09 38.73 43.53 53.13
3.4 3.6 4.0 3.1 3.3 3.7 2.8 3.0 3.4
FHP MANUFACTURING COMPANY 601 N.W. 65th Court - Fort Lauderdale, FL 33309 Phone: (954) 776-5471 - Fax: (800) 776-5529 http://www.fhp-mfg.com
EC120
2 STAGE PACKAGED UNITS
SPECIFICATION DATA SHEET
AQUARIUS SERIES
FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS
ELECTRICAL SPECIFICATIONS
MECHANICAL SPECIFICATIONS
Blower Loop Pump Electrical Elect. Compressor (x2) Characteristics Symbol RLA LRA FLA* HP* FLA HP 208/230-1-30 208/230-3-60 460-3-60 575-3-60
-1 -3 -4 -5
29.0 18.0 9.7 7.7
145.0 12.3 123.0 6.4/9.0 70.0 3.2/4.5 53.0 2.0/3.6
2 - - 2/3 - - 2/3 - - 2/3
Min. Max. Circuit Fuse/ Amps* Breaker 77.6 46.9/49.5 25.1/26.3 19.3/20.9
100 60/60 35/35 25/25
*Vertical units use one 2 HP motor (first value) while horizontal units use one 3 HP motor & 2 12x9 blowers (second value)
BLOWER PERFORMANCE Available External Static Pressure (Inches of Water, Gauge. Wet Coil and Filter Included) Motor 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 Sheave Closed - - - - - - - - 4400 4150 3830 3600 1/2 Open - - - 4660 4490 4240 3950 3600 3000 - - - Open 4680 4490 4270 4000 3700 3370 - - - - - -
Refrigerant: R-410A Air Coil Square Rows Tube Fins/ Feet Deep O.D. Inch 9.00 3 3/8 14 Water Coil Type Work Press Coaxial 450 psig Blower Size* Compr Type 15x15 BD Scroll Net Weight Ship Weight 725 lbs 770 lbs
FLUID PRESSURE DROP Fluid Pressure Flow Drop (GPM) (FOH) (PSIG) 16 4.8 2.1 20 7.2 3.1 24 10.0 4.3 28 13.2 5.7 32 16.8 7.3
ISO 13256-1 CERTIFIED PERFORMANCE DATA Rated at 4,000 CFM and 28.0 GPM Water Loop Ground Water Ground Loop (Ext. Range Required) Cooling Heating Cooling Heating Cooling Heating Capacity EER Capacity COP Capacity EER Capacity COP Capacity EER Capacity COP 124,000 13.2 158,000 4.4 134,000 18.3 123,000 3.9 127,200 14.7 100,000 3.2
CAPACITY DATA All performance at 4,000CFM and 28.0 GPM COOLING
EFT Range (Standard) 50oF to 100oF
EFT Range (Ext. Range Option) 45oF to 110oF
HEATING
Entering Entering Sensible Heat Fluid Air Total Sensible to Power of Temp. Temp. Capacity Capacity Total Input Reject EER (oF) (oF) (MBtuH) (MBtuH) Ratio (kW) (MBtuH)
50o 60o 70o 85o 100o 50o 60o 70o 85o 100o 50o 60o 70o 85o 100o 50o 60o 70o 85o 100o
115.83 70odb 112.65 61owb 109.46 104.68 99.90 124.14 75odb 120.73 63owb 117.32 112.20 107.08 136.30 80odb 132.56 67owb 128.82 123.21 117.60 148.45 85odb 144.38 71owb 140.31 134.21 128.11
76.39 74.91 73.71 72.36 71.49 91.40 89.64 88.21 86.60 85.56 100.95 99.01 97.43 95.67 94.52 110.60 108.48 106.75 104.82 103.56
0.66 0.66 0.67 0.69 0.72 0.74 0.74 0.75 0.77 0.80 0.74 0.75 0.76 0.78 0.80 0.75 0.75 0.76 0.78 0.81
6.91 7.65 8.39 9.49 10.60 6.94 7.69 8.43 9.55 10.66 7.00 7.75 8.50 9.62 10.75 7.05 7.81 8.56 9.70 10.83
139.40 138.74 138.08 137.08 136.09 147.84 146.97 146.10 144.79 143.48 160.18 159.00 157.82 156.05 154.28 172.51 171.02 169.54 167.31 165.08
16.8 14.7 13.1 11.0 9.4 17.9 15.7 13.9 11.8 10.0 19.5 17.1 15.2 12.8 10.9 21.1 18.5 16.4 13.8 11.8
Units are complete packages featuring 2 stage operation and containing compressors, reversing valve, expansion valve metering devices, and heat exchangers. Also included are safety controls: Overload protection for motors, high and low refrigerant pressure switches and a solid state lock-out circuit. Extended range option includes insulated water coils. Performance based on ARI/ISO rated air flow, fluid flow and voltage. For conditions other than rated, consult the FHP EAD selection software. Due to variations in installation actual performance may vary marginally from tabulated values. As a result of continuing research and development, specifications are subject to change without notice. EC120ip6 mod1 Rev: 05-11
EFT Range (Standard) 50oF to 80oF
EFT Range (Ext. Range Option) 25oF to 80oF
Entering Entering Fluid Air Total Power Temp. Temp. Capacity Input (oF) (oF) (MBtuH) (kW) o 134.90 9.83 50 151.74 10.26 60o 60o 168.58 10.68 70o 185.42 11.10 80o 127.56 10.01 50o 143.47 10.44 60o 70o 159.39 10.87 70o 175.30 11.30 80o 118.95 10.23 50o 133.77 10.67 60o 80o 148.58 11.11 70o 163.40 11.55 80o
LOW TEMP HEATING
25o 30o 40o 25o 30o 40o 25o 30o 40o
60o
70o
80o
90.98 99.23 115.74 86.07 93.86 109.46 80.30 87.56 102.09
Heat of Abs. COP (MBtuH) 101.33 4.0 116.73 4.3 132.13 4.6 147.53 4.9 93.39 3.7 107.84 4.0 122.28 4.3 136.72 4.5 84.03 3.4 97.35 3.7 110.66 3.9 123.97 4.1
Extended Range Option Required Antifreeze Required
8.78 8.99 9.41 8.93 9.15 9.58 9.13 9.35 9.79
61.02 68.55 83.62 55.57 62.64 76.76 49.14 55.66 68.68
3.0 3.2 3.6 2.8 3.0 3.3 2.6 2.7 3.1
FHP MANUFACTURING COMPANY 601 N.W. 65th Court - Fort Lauderdale, FL 33309 Phone: (954) 776-5471 - Fax: (800) 776-5529 http://www.fhp-mfg.com
EC150
2 STAGE HORIZONTAL PACKAGED UNITS
SPECIFICATION DATA SHEET
AQUARIUS SERIES
FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS
ELECTRICAL SPECIFICATIONS
MECHANICAL SPECIFICATIONS
Blower Loop Pump Electrical Elect. Compressor (x2) Characteristics Symbol RLA LRA FLA HP FLA HP 208/230-3-60 -3 20.5 155.0 9.0 3 - - 460-3-60 -4 9.6 75.0 4.5 3 - - 575-3-60 -5 7.6 54.0 3.6 3 - -
Min. Max. Circuit Fuse/ Amps Breaker 55.1 70 26.1 35 20.7 25
BLOWER PERFORMANCE Available External Static Pressure (Inches of Water, Gauge. Wet Coil and Filter Included) Motor 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 Sheave Closed - - - - - - 7120 6920 6530 6080 5660 5120 1/2 Open - - - 6860 6530 6120 5780 5380 4880 4090 - - Open 6770 6300 5880 5430 4970 4340 3750 - - - - -
Refrigerant: R-410A Air Coil Square Rows Tube Fins/ Feet Deep O.D. Inch 10.83 3 3/8 14 Water Coil Type Work Press Coaxial 450 psig Blower Size Compr Type 15x15 BD Scroll Net Weight Ship Weight 822 lbs 912 lbs
FLUID PRESSURE DROP Fluid Pressure Flow Drop (GPM) (FOH) (PSIG) 20 3.4 1.5 25 5.1 2.2 30 7.0 3.0 35 9.3 4.0 50 17.6 7.6
RATED IN ACCORDANCE WITH ISO 13256-1 Rated at 5,000 CFM and 35.0 GPM Water Loop Ground Water Ground Loop (Ext. Range Required) Cooling Heating Cooling Heating Cooling Heating Capacity EER Capacity COP Capacity EER Capacity COP Capacity EER Capacity COP 157,000 16.0 181,000 5.6 185,000 24.0 140,000 5.0 166,000 17.9 107,000 4.2
CAPACITY DATA All performance at 5,000 CFM and 35.0 GPM COOLING
EFT Range (Standard) 50oF to 100oF
EFT Range (Ext. Range Option) 45oF to 110oF
HEATING
Entering Entering Sensible Heat Fluid Air Total Sensible to Power of Temp. Temp. Capacity Capacity Total Input Reject EER (oF) (oF) (MBtuH) (MBtuH) Ratio (kW) (MBtuH)
50o 60o 70o 85o 100o 50o 60o 70o 85o 100o 50o 60o 70o 85o 100o 50o 60o 70o 85o 100o
160.90 70odb 151.98 61owb 143.05 129.67 116.28 172.66 75odb 163.11 63owb 153.55 139.22 124.89 189.86 80odb 179.38 67owb 168.91 153.20 137.49 207.06 85odb 195.66 71owb 184.27 167.18 150.09
105.09 100.04 95.30 88.62 82.23 126.34 120.31 114.67 106.71 99.10 139.85 133.21 126.99 118.22 109.83 153.50 146.24 139.43 129.84 120.67
0.65 0.66 0.67 0.68 0.71 0.73 0.74 0.75 0.77 0.79 0.74 0.74 0.75 0.77 0.80 0.74 0.75 0.76 0.78 0.80
8.47 9.24 10.00 11.15 12.30 8.51 9.28 10.05 11.21 12.37 8.57 9.34 10.12 11.29 12.46 8.62 9.41 10.19 11.37 12.55
189.81 183.50 177.19 167.73 158.27 201.70 194.78 187.86 177.48 167.10 219.09 211.27 203.46 191.73 180.01 236.48 227.77 219.05 205.98 192.91
19.0 16.5 14.3 11.6 9.5 20.3 17.6 15.3 12.4 10.1 22.2 19.2 16.7 13.6 11.0 24.0 20.8 18.1 14.7 12.0
Units are complete packages featuring 2 stage operation and containing compressors, reversing valve, expansion valve metering devices, and heat exchangers. Also included are safety controls: Overload protection for motors, high and low refrigerant pressure switches and a solid state lock-out circuit. Extended range option includes insulated water coils. Performance based on ARI/ISO rated air flow, fluid flow and voltage. For conditions other than rated, consult the FHP EAD selection software. Due to variations in installation actual performance may vary marginally from tabulated values. As a result of continuing research and development, specifications are subject to change without notice. EC150ip6 mod1 Rev: 05-11
EFT Range (Standard) 50oF to 80oF
EFT Range (Ext. Range Option) 25oF to 80oF
Entering Entering Fluid Air Total Power Temp. Temp. Capacity Input (oF) (oF) (MBtuH) (kW) o 155.13 9.77 50 176.61 10.36 60o 60o 198.10 10.95 70o 219.58 11.53 80o 146.89 9.92 50o 167.19 10.52 60o 70o 187.48 11.12 70o 207.78 11.72 80o 137.22 10.11 50o 156.12 10.73 60o 80o 175.02 11.34 70o 193.92 11.95 80o
LOW TEMP HEATING
25o 30o 40o 25o 30o 40o 25o 30o 40o
60o
70o
80o
99.43 109.96 131.03 94.27 104.22 124.11 88.20 97.46 115.99
Heat of Abs. COP (MBtuH) 121.79 4.7 141.27 5.0 160.74 5.3 180.21 5.6 113.03 4.3 131.28 4.7 149.52 4.9 167.77 5.2 102.70 4.0 119.51 4.3 136.31 4.5 153.12 4.8
Extended Range Option Required Antifreeze Required
8.30 8.59 9.18 8.42 8.72 9.32 8.58 8.88 9.50
71.12 80.65 99.70 65.52 74.45 92.30 58.92 67.14 83.58
3.5 3.8 4.2 3.3 3.5 3.9 3.0 3.2 3.6
FHP MANUFACTURING COMPANY 601 N.W. 65th Court - Fort Lauderdale, FL 33309 Phone: (954) 776-5471 - Fax: (800) 776-5529 http://www.fhp-mfg.com
EC151
2 STAGE VERTICAL PACKAGED UNITS
SPECIFICATION DATA SHEET
AQUARIUS SERIES
FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS
ELECTRICAL SPECIFICATIONS
MECHANICAL SPECIFICATIONS
Blower Loop Pump Electrical Elect. Compressor (x2) Characteristics Symbol LRA FLA HP FLA HP RLA
Min. Max. Circuit Fuse/ Amps Breaker
208/230-3-60 460-3-60 575-3-60
55.1 26.1 21.1
-3 -4 -5
20.5 9.6 7.6
155.0 75.0 54.0
9.0 4.5 2.0
3 3 1.5
- - -
- - -
70 35 25
BLOWER PERFORMANCE Available External Static Pressure (Inches of Water, Gauge. Wet Coil and Filter Included) Motor 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 Sheave High - - - - - - 7120 6920 6530 6080 5660 5120 Medium - - - 6860 6530 6120 5780 5380 4880 4090 - Low 6770 6300 5880 5430 4970 4340 3750 - - - - -
Refrigerant: R-410A Air Coil Square Rows Tube Fins/ Feet Deep O.D. Inch 14.33 3 3/8 14 Water Coil Type Work Press Coaxial 450 psig Blower Size Compr Type 15x15 BD Scroll Net Weight Ship Weight 882 lbs 972 lbs
FLUID PRESSURE DROP Fluid Pressure Flow Drop (GPM) (FOH) (PSIG) 20 3.4 1.5 25 5.1 2.2 30 7.0 3.0 35 9.3 4.0 50 17.6 7.6
RATED IN ACCORDANCE WITH ISO 13256-1 Rated at 5,000 CFM and 35.0 GPM Water Loop Ground Water Ground Loop (Ext. Range Required) Cooling Heating Cooling Heating Cooling Heating Capacity EER Capacity COP Capacity EER Capacity COP Capacity EER Capacity COP 147,000 16.0 181,000 5.6 175,000 24.0 140,000 5.0 155,000 17.9 107,000 4.2
CAPACITY DATA All performance at 5,000 CFM and 35.0 GPM EFT Range (Standard) 50oF to 100oF
COOLING
EFT Range (Ext. Range Option) 45oF to 110oF
HEATING
Entering Entering Sensible Heat Fluid Air Total Sensible to Power of Temp. Temp. Capacity Capacity Total Input Reject EER (oF) (oF) (MBtuH) (MBtuH) Ratio (kW) (MBtuH)
50o 60o 70o 85o 100o 50o 60o 70o 85o 100o 50o 60o 70o 85o 100o 50o 60o 70o 85o 100o
70 db 61owb o
75odb 63owb
80odb 67owb
85odb 71owb
152.16 143.16 134.17 120.67 107.17 163.30 153.67 144.04 129.59 115.14 179.60 169.04 158.48 142.64 126.80 195.90 184.41 172.92 155.69 138.46
99.28 94.12 89.25 82.34 75.65 119.41 113.27 107.47 99.23 91.27 132.21 125.44 119.06 109.98 101.20 145.15 137.75 130.76 120.83 111.23
0.65 0.66 0.67 0.68 0.71 0.73 0.74 0.75 0.77 0.79 0.74 0.74 0.75 0.77 0.80 0.74 0.75 0.76 0.78 0.80
8.12 8.81 9.50 10.53 11.56 8.16 8.85 9.54 10.58 11.62 8.21 8.91 9.61 10.65 11.70 8.27 8.97 9.67 10.73 11.78
179.88 173.23 166.57 156.59 146.62 191.15 183.88 176.60 165.70 154.79 207.63 199.45 191.27 179.00 166.73 224.11 215.02 205.93 192.30 178.67
18.7 16.3 14.1 11.5 9.3 20.0 17.4 15.1 12.2 9.9 21.9 19.0 16.5 13.4 10.8 23.7 20.6 17.9 14.5 11.8
Units are complete packages featuring 2 stage operation and containing compressors, reversing valve, expansion valve metering devices, and heat exchangers. Also included are safety controls: Overload protection for motors, high and low refrigerant pressure switches and a solid state lock-out circuit. Extended range option includes insulated water coils. Performance based on ARI/ISO rated air flow, fluid flow and voltage. For conditions other than rated, consult the FHP EAD selection software. Due to variations in installation actual performance may vary marginally from tabulated values. As a result of continuing research and development, specifications are subject to change without notice. EC151ip6 mod1 Rev: 05-11
EFT Range (Standard) 50oF to 80oF
EFT Range (Ext. Range Option) 25oF to 80oF
Entering Entering Heat Fluid Air Total Power of Temp. Temp. Capacity Input Abs. COP (oF) (oF) (MBtuH) (kW) (MBtuH)
50o 60o 70o 80o 50o 60o 70o 80o 50o 60o 70o 80o
60o
70o
80o
155.13 176.61 198.10 219.58 146.89 167.19 187.48 207.78 137.22 156.12 175.02 193.92
LOW TEMP HEATING
25o 30o 40o 25o 30o 40o 25o 30o 40o
60o
70o
80o
99.43 109.96 131.03 94.27 104.22 124.11 88.20 97.46 115.99
9.77 10.36 10.95 11.53 9.92 10.52 11.12 11.72 10.11 10.73 11.34 11.95
121.79 141.27 160.74 180.21 113.03 131.28 149.52 167.77 102.70 119.51 136.31 153.12
4.7 5.0 5.3 5.6 4.3 4.7 4.9 5.2 4.0 4.3 4.5 4.8
Extended Range Option Required Antifreeze Required
8.30 8.59 9.18 8.42 8.72 9.32 8.58 8.88 9.50
71.12 80.65 99.70 65.52 74.45 92.30 58.92 67.14 83.58
3.5 3.8 4.2 3.3 3.5 3.9 3.0 3.2 3.6
FHP MANUFACTURING COMPANY 601 N.W. 65th Court - Fort Lauderdale, FL 33309 Phone: (954) 776-5471 - Fax: (800) 776-5529 http://www.fhp-mfg.com
EC180
2 STAGE HORIZONTAL PACKAGED UNITS
SPECIFICATION DATA SHEET
AQUARIUS SERIES
FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS
MECHANICAL SPECIFICATIONS
ELECTRICAL SPECIFICATIONS Loop Pump Electrical Elect. Compressor (x2) Blower (x2) Characteristics Symbol LRA FLA HP FLA HP RLA 208/230-3-60
460-3-60 575-3-60
-3 -4 -5
22.4 10.6 7.7
149.0 75.0 54.0
6.4 3.2 2.0
2 2 2
- - -
Min. Max. Circuit Fuse/ Amps Breaker
- - -
63.2 30.3 21.3
80 40 25
BLOWER PERFORMANCE Available External Static Pressure (Inches of Water, Gauge. Wet Coil and Filter Included) Motor 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 Sheave Closed - - - - - - 7200 6940 6560 6150 5710 5140 1/2 Open - - 7200 6930 6580 6200 5800 5450 4920 - - - Open 6780 6350 5970 5540 5050 4510 - - - - - -
Refrigerant: R-410A Air Coil Square Rows Tube Fins/ Feet Deep O.D. Inch 10.83 3 3/8 14 Water Coil Type Work Press Coaxial 450 psig Blower Size Compr Type 12x12 BD Scroll Net Weight Ship Weight HZ 1,010 lbs 1,100 lbs
FLUID PRESSURE DROP Fluid Pressure Flow Drop (GPM) (FOH) (PSIG) 22 4.0 1.7 27 5.8 2.5 32 7.9 3.4 42 12.9 5.6 52 18.9 8.2
RATED IN ACCORDANCE WITH ISO 13256-1 Rated at 6,000 CFM and 42.0 GPM Water Loop Ground Water Ground Loop (Ext. Range Required) Cooling Heating Cooling Heating Cooling Heating Capacity EER Capacity COP Capacity EER Capacity COP Capacity EER Capacity COP 182,000 14.2 204,000 5.0 195,000 20.0 156,000 4.2 185,000 15.4 118,000 3.5
CAPACITY DATA All performance at 6,000 CFM and 42.0 GPM COOLING
EFT Range (Standard) 50oF to 100oF
EFT Range (Ext. Range Option) 45oF to 110oF
HEATING
Entering Entering Sensible Heat Fluid Air Total Sensible to Power of Temp. Temp. Capacity Capacity Total Input Reject EER (oF) (oF) (MBtuH) (MBtuH) Ratio (kW) (MBtuH)
50o 60o 70o 85o 100o 50o 60o 70o 85o 100o 50o 60o 70o 85o 100o 50o 60o 70o 85o 100o
165.85 70odb 161.63 61owb 157.40 151.06 144.72 177.90 75odb 173.38 63owb 168.85 162.07 155.28 195.52 80odb 190.57 67owb 185.61 178.17 170.73 213.15 85odb 207.75 71owb 202.36 194.27 186.18
108.66 106.78 105.30 103.78 102.97 130.43 128.19 126.43 124.62 123.66 144.28 141.81 139.87 137.87 136.82 158.27 155.57 153.45 151.26 150.11
0.66 0.66 0.67 0.69 0.71 0.73 0.74 0.75 0.77 0.80 0.74 0.74 0.75 0.77 0.80 0.74 0.75 0.76 0.78 0.81
9.80 10.91 12.03 13.71 15.39 9.85 10.97 12.10 13.78 15.47 9.91 11.05 12.18 13.89 15.59 9.98 11.13 12.27 13.99 15.70
199.29 198.88 198.47 197.86 197.24 211.50 210.82 210.14 209.11 208.09 229.36 228.28 227.19 225.56 223.93 247.23 245.74 244.25 242.01 239.78
16.9 14.8 13.1 11.0 9.4 18.1 15.8 14.0 11.8 10.0 19.7 17.2 15.2 12.8 11.0 21.3 18.7 16.5 13.9 11.9
Units are complete packages featuring 2 stage operation and containing compressors, reversing valve, expansion valve metering devices, and heat exchangers. Also included are safety controls: Overload protection for motors, high and low refrigerant pressure switches and a solid state lock-out circuit. Extended range option includes insulated water coils. Performance based on ARI/ISO rated air flow, fluid flow and voltage. For conditions other than rated, consult the FHP EAD selection software. Due to variations in installation actual performance may vary marginally from tabulated values. As a result of continuing research and development, specifications are subject to change without notice. EC180ip6 mod1 Rev: 05-11
EFT Range (Standard) 50oF to 80oF
EFT Range (Ext. Range Option) 25oF to 80oF
Entering Entering Fluid Air Total Power Temp. Temp. Capacity Input (oF) (oF) (MBtuH) (kW) o 171.73 11.87 50 196.70 12.49 60o 60o 221.66 13.11 70o 246.63 13.73 80o 162.53 12.07 50o 186.12 12.70 60o 70o 209.70 13.34 70o 233.29 13.97 80o 151.73 12.32 50o 173.69 12.96 60o 80o 195.66 13.61 70o 217.62 14.26 80o
LOW TEMP HEATING
25o 30o 40o 25o 30o 40o 25o 30o 40o
60o
70o
80o
107.18 119.42 143.89 101.54 113.10 136.22 94.92 105.68 127.22
Heat of Abs. COP (MBtuH) 131.22 4.2 154.06 4.6 176.91 5.0 199.75 5.3 121.34 3.9 142.76 4.3 164.19 4.6 185.61 4.9 109.69 3.6 129.45 3.9 149.20 4.2 168.96 4.5
Extended Range Option Required Antifreeze Required
10.32 10.63 11.25 10.49 10.80 11.44 10.70 11.02 11.67
71.96 83.14 105.49 65.75 76.23 97.19 58.41 68.07 87.40
3.0 3.3 3.7 2.8 3.1 3.5 2.6 2.8 3.2
FHP MANUFACTURING COMPANY 601 N.W. 65th Court - Fort Lauderdale, FL 33309 Phone: (954) 776-5471 - Fax: (800) 776-5529 http://www.fhp-mfg.com
EC181
2 STAGE VERTICAL PACKAGED UNITS
SPECIFICATION DATA SHEET
AQUARIUS SERIES
FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS
MECHANICAL SPECIFICATIONS
ELECTRICAL SPECIFICATIONS Blower Loop Pump Electrical Elect. Compressor (x2) Characteristics Symbol LRA FLA HP FLA HP RLA 208/230-3-60
460-3-60 575-3-60
-3 -4 -5
22.4 10.6 7.7
149.0 75.0 54.0
12.2 6.1 5.4
5 5 5
- - -
Min. Max. Circuit Fuse/ Amps Breaker
- - -
62.6 30.0 22.7
80 40 30
BLOWER PERFORMANCE Available External Static Pressure (Inches of Water, Gauge. Wet Coil and Filter Included) Motor 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 Sheave Closed - - - - - - 7200 6940 6560 6150 5710 5140 1/2 Open - - 7200 6930 6580 6200 5800 5450 4920 - - - Open 6780 6350 5970 5540 5050 4510 - - - - - -
Refrigerant: R-410A Air Coil Square Rows Tube Fins/ Feet Deep O.D. Inch 14.33 3 3/8 14 Water Coil Type Work Press Coaxial 450 psig Blower Size Compr Type 15x15 BD Scroll Net Weight Ship Weight 885 lbs 975 lbs
FLUID PRESSURE DROP Fluid Pressure Flow Drop (GPM) (FOH) (PSIG) 22 4.0 1.7 27 5.8 2.5 32 7.9 3.4 42 12.9 5.6 52 18.9 8.2
RATED IN ACCORDANCE WITH ISO 13256-1 Rated at 6,000 CFM and 42.0 GPM Water Loop Ground Water Ground Loop (Ext. Range Required) Cooling Heating Cooling Heating Cooling Heating Capacity EER Capacity COP Capacity EER Capacity COP Capacity EER Capacity COP 170,000 14.2 204,000 5.0 185,000 20.0 156,000 4.2 175,000 15.4 118,000 3.5
CAPACITY DATA All performance at 6,000 CFM and 42.0 GPM EFT Range (Standard) 50oF to 100oF
COOLING
EFT Range (Ext. Range Option) 45oF to 110oF
HEATING
EFT Range (Standard) 50oF to 80oF
EFT Range (Ext. Range Option) 25oF to 80oF
Entering Entering Sensible Heat Fluid Air Total Sensible to Power of Temp. Temp. Capacity Capacity Total Input Reject EER (oF) (oF) (MBtuH) (MBtuH) Ratio (kW) (MBtuH)
Entering Entering Heat Fluid Air Total Power of Temp. Temp. Capacity Input Abs. COP (oF) (oF) (MBtuH) (kW) (MBtuH)
50o 60o 70o 85o 100o 50o 60o 70o 85o 100o 50o 60o 70o 85o 100o 50o 60o 70o 85o 100o
70 db 61owb o
75odb 63owb
80odb 67owb
85odb 71owb
158.00 153.22 148.45 141.29 134.13 169.49 164.38 159.27 151.61 143.95 186.31 180.71 175.11 166.71 158.31 203.12 197.03 190.94 181.80 172.66
103.43 101.14 99.22 96.97 95.33 124.20 121.47 119.19 116.50 114.56 137.41 134.40 131.89 128.93 126.79 150.76 147.47 144.72 141.48 139.14
0.65 0.66 0.67 0.69 0.71 0.73 0.74 0.75 0.77 0.80 0.74 0.74 0.75 0.77 0.80 0.74 0.75 0.76 0.78 0.81
9.43 10.43 11.43 12.93 14.43 9.48 10.49 11.49 13.00 14.51 9.55 10.56 11.58 13.10 14.62 9.61 10.64 11.66 13.19 14.73
190.19 188.83 187.47 185.43 183.40 201.84 200.17 198.50 195.99 193.47 218.89 216.75 214.61 211.41 208.20 235.93 233.33 230.73 226.83 222.93
16.8 14.7 13.0 10.9 9.9 17.9 15.7 13.9 11.7 9.9 19.5 17.1 15.1 12.7 10.8 21.1 18.5 16.4 13.8 11.7
Units are complete packages featuring 2 stage operation and containing compressors, reversing valve, expansion valve metering devices, and heat exchangers. Also included are safety controls: Overload protection for motors, high and low refrigerant pressure switches and a solid state lock-out circuit. Extended range option includes insulated water coils. Performance based on ARI/ISO rated air flow, fluid flow and voltage. For conditions other than rated, consult the FHP EAD selection software. Due to variations in installation actual performance may vary marginally from tabulated values. As a result of continuing research and development, specifications are subject to change without notice. EC181ip6 mod1 Rev: 05-11
50o 60o 70o 80o 50o 60o 70o 80o 50o 60o 70o 80o
60o
70o
80o
171.73 196.70 221.66 246.63 162.53 186.12 209.70 233.29 151.73 173.69 195.66 217.62
LOW TEMP HEATING
25o 30o 40o 25o 30o 40o 25o 30o 40o
60o
70o
80o
107.18 119.42 143.89 101.54 113.10 136.22 94.92 105.68 127.22
11.87 12.49 13.11 13.73 12.07 12.70 13.34 13.97 12.32 12.96 13.61 14.26
131.22 154.06 176.91 199.75 121.34 142.76 164.19 185.61 109.69 129.45 149.20 168.96
4.2 4.6 5.0 5.3 3.9 4.3 4.6 4.9 3.6 3.9 4.2 4.5
Extended Range Option Required Antifreeze Required
10.32 10.63 11.25 10.49 10.80 11.44 10.70 11.02 11.67
71.96 83.14 105.49 65.75 76.23 97.19 58.41 68.07 87.40
3.0 3.3 3.7 2.8 3.1 3.5 2.6 2.8 3.2
FHP MANUFACTURING COMPANY 601 N.W. 65th Court - Fort Lauderdale, FL 33309 Phone: (954) 776-5471 - Fax: (800) 776-5529 http://www.fhp-mfg.com
EC210
2 STAGE VERTICAL PACKAGED UNITS
SPECIFICATION DATA SHEET
AQUARIUS SERIES
FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS
ELECTRICAL SPECIFICATIONS
MECHANICAL SPECIFICATIONS
Loop Pump Electrical Elect. Compressor (x2) Blower (x2) Characteristics Symbol LRA FLA HP FLA HP RLA 208/230-3-60 460-3-60 575-3-60
-3 -4 -5
29.5 14.7 12.2
195.0 95.0 80.0
5.0 2.5 2.0
1-1/2 1-1/2 1-1/2
- - -
Min. Max. Circuit Fuse/ Amps Breaker
- - -
76.4 38.1 31.5
100 50 40
BLOWER PERFORMANCE Available External Static Pressure (Inches of Water, Gauge. Wet Coil and Filter Included) Motor 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 Sheave Closed - - - - - - - - - - 7800 7500 1/2 Open - - - - - 8600 8200 7600 6900 5240 - - Open 8840 8400 8000 7560 7000 6400 - - - - - -
Refrigerant: R-410A Air Coil Square Rows Tube Fins/ Feet Deep O.D. Inch 18.10 3 3/8 14 Water Coil Type Work Press Coaxial 450 psig Blower Size Compr Type 15x15 BD Scroll Net Weight Ship Weight 1,090 lbs 1,180 lbs
FLUID PRESSURE DROP Fluid Pressure Flow Drop (GPM) (FOH) (PSIG) 30 5.9 2.6 40 9.9 4.3 50 14.8 6.4 60 20.5 8.9 70 27.0 11.7
RATED IN ACCORDANCE WITH ISO 13256-1 Rated at 7,000 CFM and 50.0 GPM Water Loop Ground Water Ground Loop (Ext. Range Required) Cooling Heating Cooling Heating Cooling Heating Capacity EER Capacity COP Capacity EER Capacity COP Capacity EER Capacity COP 220,000 14.6 270,000 5.1 292,000 22.5 204,000 4.5 250,000 17.2 152,000 3.9
CAPACITY DATA All performance at 7,000 CFM and 50.0 GPM EFT Range (Standard) 50oF to 100oF
COOLING
EFT Range (Ext. Range Option) 45oF to 110oF
HEATING
Entering Entering Sensible Heat Fluid Air Total Sensible to Power of Temp. Temp. Capacity Capacity Total Input Reject EER (oF) (oF) (MBtuH) (MBtuH) Ratio (kW) (MBtuH)
50o 60o 70o 85o 100o 50o 60o 70o 85o 100o 50o 60o 70o 85o 100o 50o 60o 70o 85o 100o
70 db 61owb o
75odb 63owb
80odb 67owb
85odb 71owb
263.76 241.26 218.76 185.02 151.27 282.93 258.85 234.76 198.64 162.52 310.97 284.57 258.17 218.57 178.97 339.01 310.29 281.58 238.50 195.43
172.75 159.18 145.98 126.49 106.81 207.40 191.22 175.50 152.29 128.84 229.43 211.60 194.28 168.70 142.85 251.69 232.19 213.25 185.27 157.01
0.65 0.66 0.67 0.68 0.71 0.73 0.74 0.75 0.77 0.79 0.74 0.74 0.75 0.77 0.80 0.74 0.75 0.76 0.78 0.80
14.11 14.86 15.61 16.75 17.88 14.18 14.93 15.69 16.83 17.97 14.27 15.04 15.80 16.95 18.10 14.37 15.14 15.91 17.07 18.23
311.90 291.98 272.05 242.17 212.29 331.31 309.82 288.32 256.09 223.85 359.68 335.90 312.11 276.43 240.74 388.06 361.98 335.89 296.76 257.64
18.7 16.2 14.0 11.0 8.5 20.0 17.3 15.0 11.8 9.0 21.8 18.9 16.3 12.9 9.9 23.6 20.5 17.7 14.0 10.7
Units are complete packages featuring 2 stage operation and containing compressors, reversing valve, expansion valve metering devices, and heat exchangers. Also included are safety controls: Overload protection for motors, high and low refrigerant pressure switches and a solid state lock-out circuit. Extended range option includes insulated water coils. Performance based on ARI/ISO rated air flow, fluid flow and voltage. For conditions other than rated, consult the FHP EAD selection software. Due to variations in installation actual performance may vary marginally from tabulated values. As a result of continuing research and development, specifications are subject to change without notice. EC210ip6 mod1 Rev: 05-11
EFT Range (Standard) 50oF to 80oF
EFT Range (Ext. Range Option) 25oF to 80oF
Entering Entering Heat Fluid Air Total Power of Temp. Temp. Capacity Input Abs. COP (oF) (oF) (MBtuH) (kW) (MBtuH)
50o 60o 70o 80o 50o 60o 70o 80o 50o 60o 70o 80o
60o
70o
80o
226.52 260.78 295.04 329.29 214.47 246.84 279.20 311.57 200.32 230.46 260.60 290.74
LOW TEMP HEATING
25o 30o 40o 25o 30o 40o 25o 30o 40o
60o
70o
80o
138.11 154.91 188.49 130.94 146.81 178.54 122.51 137.29 166.84
15.14 16.32 17.50 18.68 15.38 16.58 17.79 18.99 15.68 16.91 18.14 19.37
174.86 205.09 235.32 265.55 161.98 190.23 218.49 246.75 146.80 172.74 198.68 224.62
4.4 4.7 4.9 5.2 4.1 4.4 4.6 4.8 3.7 4.0 4.2 4.4
Extended Range Option Required Antifreeze Required
12.19 12.78 13.96 12.37 12.98 14.18 12.60 13.22 14.45
96.52 111.30 140.86 88.71 102.52 130.15 79.49 923.0 117.52
3.3 3.6 4.0 3.1 3.3 3.7 2.8 3.0 3.4
FHP MANUFACTURING COMPANY 601 N.W. 65th Court - Fort Lauderdale, FL 33309 Phone: (954) 776-5471 - Fax: (800) 776-5529 http://www.fhp-mfg.com
EC240
2 STAGE VERTICAL PACKAGED UNITS
SPECIFICATION DATA SHEET
AQUARIUS SERIES
FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS
ELECTRICAL SPECIFICATIONS
MECHANICAL SPECIFICATIONS
Loop Pump Electrical Elect. Compressor (x2) Blower (x2) Characteristics Symbol RLA LRA FLA HP FLA HP 208/230-3-60 -3 30.1 225.0 6.4 2 - - 460-3-60 -4 16.7 114.0 3.2 2 - - 575-3-60 -5 12.2 80.0 2.0 2 - -
Min. Max. Circuit Fuse/ Amps Breaker 80.5 110 44.0 60 31.5 40
BLOWER PERFORMANCE Available External Static Pressure (Inches of Water, Gauge. Wet Coil and Filter Included) Motor 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 Sheave Closed - - - - - - - - 9000 8800 8330 7660 1/2 Open - - - - 9320 8980 8480 7900 7200 6000 - - Open 9360 8980 8540 8000 7400 6740 - - - - - -
Refrigerant: R-410A Air Coil Square Rows Tube Fins/ Feet Deep O.D. Inch 18.10 3 3/8 14 Water Coil Type Work Press Coaxial 450 psig Blower Size Compr Type 15x15 BD Scroll Net Weight Ship Weight 1,310 lbs 1,400 lbs
FLUID PRESSURE DROP Fluid Pressure Flow Drop (GPM) (FOH) (PSIG) 30 3.7 1.6 40 6.2 2.7 50 9.3 4.0 60 12.9 5.6 75 19.2 8.3
RATED IN ACCORDANCE WITH ISO 13256-1 Rated at 8,000 CFM and 60.0 GPM Water Loop Ground Water Ground Loop (Ext. Range Required) Cooling Heating Cooling Heating Cooling Heating Capacity EER Capacity COP Capacity EER Capacity COP Capacity EER Capacity COP 248,000 14.4 315,000 5.0 310,000 21.1 250,000 4.5 275,000 16.0 180,000 3.9
CAPACITY DATA All performance at 8,000 CFM and 60.0 GPM COOLING
EFT Range (Standard) 50oF to 100oF
EFT Range (Ext. Range Option) 45oF to 110oF
HEATING
Entering Entering Sensible Heat Fluid Air Total Sensible to Power of Temp. Temp. Capacity Capacity Total Input Reject EER (oF) (oF) (MBtuH) (MBtuH) Ratio (kW) (MBtuH)
50o 60o 70o 85o 100o 50o 60o 70o 85o 100o 50o 60o 70o 85o 100o 50o 60o 70o 85o 100o
276.26 70odb 256.97 61owb 237.68 208.74 179.80 296.32 75odb 275.67 63owb 255.02 224.04 193.06 325.67 80odb 303.03 67owb 280.39 246.43 212.47 355.01 85odb 330.39 71owb 305.76 268.82 231.88
181.03 169.68 158.79 142.99 127.35 217.28 203.75 190.79 171.97 153.34 240.34 225.43 211.14 190.40 169.87 263.63 247.33 231.70 209.02 186.56
0.66 0.66 0.67 0.69 0.71 0.73 0.74 0.75 0.77 0.79 0.74 0.74 0.75 0.77 0.80 0.74 0.75 0.76 0.78 0.80
15.75 16.72 17.68 19.12 20.56 15.83 16.80 17.77 19.22 20.67 15.94 16.92 17.89 19.36 20.82 16.06 17.04 18.02 19.50 20.97
330.03 314.02 298.01 273.99 249.97 350.36 333.01 315.66 289.63 263.61 380.09 360.78 341.46 312.50 283.53 409.81 388.54 367.27 335.36 303.45
17.5 15.4 13.4 10.9 8.7 18.7 16.4 14.4 11.7 9.3 20.4 17.9 15.7 12.7 10.2 22.1 19.4 17.0 13.8 11.1
Units are complete packages featuring 2 stage operation and containing compressors, reversing valve, expansion valve metering devices, and heat exchangers. Also included are safety controls: Overload protection for motors, high and low refrigerant pressure switches and a solid state lock-out circuit. Extended range option includes insulated water coils. Performance based on ARI/ISO rated air flow, fluid flow and voltage. For conditions other than rated, consult the FHP EAD selection software. Due to variations in installation actual performance may vary marginally from tabulated values. As a result of continuing research and development, specifications are subject to change without notice. EC240VTip6 mod1 Rev: 05-11
EFT Range (Standard) 50oF to 80oF
EFT Range (Ext. Range Option) 25oF to 80oF
Entering Entering Fluid Air Total Power Temp. Temp. Capacity Input (oF) (oF) (MBtuH) (kW) o 268.16 17.79 50 307.37 19.21 60o 60o 346.57 20.64 70o 385.77 22.06 80o 253.82 18.08 50o 290.86 19.53 60o 70o 327.89 20.98 70o 364.93 22.44 80o 236.97 18.45 50o 271.47 19.93 60o 80o 305.96 21.41 70o 340.45 22.90 80o
LOW TEMP HEATING
25o 30o 40o 25o 30o 40o 25o 30o 40o
60o
70o
80o
166.82 186.04 224.47 158.07 176.22 212.53 147.79 164.69 198.51
Heat of Abs. COP (MBtuH) 207.45 4.4 241.79 4.7 276.14 4.9 310.48 5.1 192.10 4.1 224.19 4.4 256.27 4.6 288.36 4.8 174.02 3.8 203.45 4.0 232.87 4.2 262.30 4.4
Extended Range Option Required Antifreeze Required
14.23 14.94 16.37 14.46 15.18 16.63 14.73 15.48 16.96
118.25 135.04 168.62 108.73 124.41 155.77 97.50 111.87 140.62
3.4 3.6 4.0 3.2 3.4 3.7 2.9 3.1 3.4
FHP MANUFACTURING COMPANY 601 N.W. 65th Court - Fort Lauderdale, FL 33309 Phone: (954) 776-5471 - Fax: (800) 776-5529 http://www.fhp-mfg.com
EC242
2 STAGE HORIZONTAL PACKAGED UNITS
SPECIFICATION DATA SHEET
AQUARIUS SERIES
FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS
ELECTRICAL SPECIFICATIONS
MECHANICAL SPECIFICATIONS
Electrical Elect. Compressor (x2) Blower (x2) Loop Pump Characteristics Symbol RLA LRA FLA HP FLA HP 208/230-3-60 460-3-60 575-3-60
-3 -4 -5
30.1 16.7 12.2
225.0 114.0 80.0
6.4 3.2 2.0
2 2 2
- - -
Min. Max. Circuit Fuse/ Amps Breaker 80.5 110 44.0 60 31.5 40
- - -
BLOWER PERFORMANCE Available External Static Pressure (Inches of Water, Gauge. Wet Coil and Filter Included) Motor 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 Sheave Closed - - - - - - - - - - 8120 7500 1/2 Open - - - - - - 8280 7700 7000 5800 - - Open - - 8340 7800 7200 6540 - - - - - -
Refrigerant: R-410A Air Coil Square Rows Tube Fins/ Feet Deep O.D. Inch 15.30 3 3/8 14 Water Coil Type Work Press Coaxial 450 psig Blower Size Compr Type 15x15 BD Scroll Net Weight Ship Weight 1,310 lbs 1,400 lbs
FLUID PRESSURE DROP Fluid Pressure Flow Drop (GPM) (FOH) (PSIG) 30 3.7 1.6 40 6.2 2.7 50 9.3 4.0 60 12.9 5.6 75 19.2 8.3
RATED IN ACCORDANCE WITH ISO 13256-1 Rated at 8,000 CFM and 60.0 GPM Water Loop Ground Water Ground Loop (Ext. Range Required) Cooling Heating Cooling Heating Cooling Heating Capacity EER Capacity COP Capacity EER Capacity COP Capacity EER Capacity COP 248,000 14.4 315,000 5.0 310,000 21.1 250,000 4.5 275,000 16.0 180,000 3.9
CAPACITY DATA All performance at 8,000 CFM and 60.0 GPM EFT Range (Standard) 50oF to 100oF
COOLING
EFT Range (Ext. Range Option) 45oF to 110oF
HEATING
Entering Entering Sensible Heat Fluid Air Total Sensible to Power of Temp. Temp. Capacity Capacity Total Input Reject EER (oF) (oF) (MBtuH) (MBtuH) Ratio (kW) (MBtuH)
50o 60o 70o 85o 100o 50o 60o 70o 85o 100o 50o 60o 70o 85o 100o 50o 60o 70o 85o 100o
70 db 61owb o
75odb 63owb
80odb 67owb
85odb 71owb
276.80 257.51 238.21 209.27 180.33 296.86 276.21 255.55 224.58 193.60 326.20 303.56 280.92 246.96 213.00 355.55 330.92 306.29 269.35 232.41
179.28 168.06 157.31 141.70 126.25 215.10 201.73 188.92 170.33 151.92 237.88 223.15 209.03 188.54 168.25 260.89 244.78 229.34 206.93 184.75
0.65 0.65 0.66 0.68 0.70 0.72 0.73 0.74 0.76 0.78 0.73 0.74 0.74 0.76 0.79 0.73 0.74 0.75 0.77 0.79
15.60 16.56 17.52 18.96 20.40 15.68 16.64 17.61 19.06 20.51 15.79 16.76 17.74 19.20 20.66 15.90 16.88 17.87 19.34 20.82
330.03 314.02 298.01 273.99 249.97 350.36 333.01 315.66 289.63 263.61 380.09 360.78 341.46 312.50 283.53 409.81 388.54 367.27 335.36 303.45
17.7 15.6 13.6 11.0 8.8 18.9 16.6 14.5 11.8 9.4 20.7 18.1 15.8 12.9 10.3 22.4 19.6 17.1 13.9 11.2
Units are complete packages featuring 2 stage operation and containing compressors, reversing valve, expansion valve metering devices, and heat exchangers. Also included are safety controls: Overload protection for motors, high and low refrigerant pressure switches and a solid state lock-out circuit. Extended range option includes insulated water coils. Performance based on ARI/ISO rated air flow, fluid flow and voltage. For conditions other than rated, consult the FHP EAD selection software. Due to variations in installation actual performance may vary marginally from tabulated values. As a result of continuing research and development, specifications are subject to change without notice. EC242HZip6 mod1 Rev: 05-11
EFT Range (Standard) 50oF to 80oF
EFT Range (Ext. Range Option) 25oF to 80oF
Entering Entering Heat Fluid Air Total Power of Temp. Temp. Capacity Input Abs. COP (oF) (oF) (MBtuH) (kW) (MBtuH)
50o 60o 70o 80o 50o 60o 70o 80o 50o 60o 70o 80o
60o
70o
80o
267.63 306.83 346.03 385.24 253.29 290.32 327.36 364.40 236.44 270.93 305.42 339.92
LOW TEMP HEATING
25o 30o 40o 25o 30o 40o 25o 30o 40o
60o
70o
80o
166.30 185.51 223.95 157.54 175.70 212.01 147.26 164.17 197.99
17.63 19.06 20.48 21.90 17.93 19.38 20.83 22.28 18.29 19.77 21.26 22.74
207.45 241.79 276.14 310.48 192.10 224.19 256.27 288.36 174.02 203.45 232.87 262.30
4.4 4.7 5.0 5.2 4.1 4.4 4.6 4.8 3.8 4.0 4.2 4.4
Extended Range Option Required Antifreeze Required
14.07 14.79 16.21 14.30 15.02 16.48 14.58 15.32 16.80
118.26 135.05 168.63 108.74 124.42 155.78 97.51 111.88 140.63
3.5 3.7 4.0 3.2 3.4 3.8 3.0 3.1 3.5
FHP MANUFACTURING COMPANY 601 N.W. 65th Court - Fort Lauderdale, FL 33309 Phone: (954) 776-5471 - Fax: (800) 776-5529 http://www.fhp-mfg.com
EC300
2 STAGE VERTICAL PACKAGED UNITS
SPECIFICATION DATA SHEET
AQUARIUS SERIES
FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS
ELECTRICAL SPECIFICATIONS
MECHANICAL SPECIFICATIONS
Loop Pump Electrical Elect. Compressor (x2) Blower (x2) Characteristics Symbol RLA LRA FLA HP FLA HP 208/230-3-60 460-3-60 575-3-60
-3 -4 -5
48.1 18.6 14.7
245.0 125.0 100.0
9.0 4.5 3.6
3 3 3
- - -
Min. Max. Circuit Fuse/ Amps Breaker 126.2 150 50.9 60 40.3 50
- - -
BLOWER PERFORMANCE Available External Static Pressure (Inches of Water, Gauge. Wet Coil and Filter Included) Blower 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10 1.20 Speed Closed - - - - 10000 9650 9300 8950 8600 8200 - - 1/2 Open - 10500 10100 9700 8900 8500 8100 - - - - - Open 9900 9100 8700 8300 - - - - - - - -
Refrigerant: R-410A Air Coil Square Rows Tube Fins/ Feet Deep O.D. Inch 18.1 3 3/8 14 Water Coil Type Work Press Coaxial 450 psig Blower Size Compr Type 15 x 15 BD Scroll Net Weight Ship Weight 1,350 lbs 1,450 lbs
FLUID PRESSURE DROP Fluid Pressure Flow Drop (GPM) (FOH) (PSIG) 40 6.2 2.7 50 9.2 4.0 60 12.8 5.5 75 19.1 8.3 85 24.0 10.4
PERFORMANCE DATA Rated in accordance with ISO 13256-1 at 10,000 CFM and 75.0 GPM Water Loop Ground Water Ground Loop (Ext. Range Required) Cooling Heating Cooling Heating Cooling Heating Capacity EER Capacity COP Capacity EER Capacity COP Capacity EER Capacity COP 295,000 13.0 376,000 4.2 365,000 18.8 300,000 3.8 318,000 14.0 222,000 3.2
CAPACITY DATA All performance at 10,000 CFM and 75.0 GPM COOLING
EFT Range (Standard) 50oF to 100oF
EFT Range (Ext. Range Option) 45oF to 110oF
HEATING
Entering Entering Sensible Heat Fluid Air Total Sensible to Power of Temp. Temp. Capacity Capacity Total Input Reject EER (oF) (oF) (MBtuH) (MBtuH) Ratio (kW) (MBtuH)
50o 60o 70o 85o 100o 50o 60o 70o 85o 100o 50o 60o 70o 85o 100o 50o 60o 70o 85o 100o
329.18 70odb 306.89 61owb 284.59 251.16 217.72 352.69 75odb 328.83 63owb 304.97 269.18 233.39 387.09 80odb 360.93 67owb 334.77 295.53 256.30 421.48 85odb 393.03 71owb 364.57 321.89 279.21
217.55 204.46 191.92 173.75 155.80 260.04 244.44 229.51 207.87 186.48 287.07 269.88 253.42 229.57 206.00 314.37 295.57 277.57 251.49 225.71
0.66 0.67 0.67 0.69 0.72 0.74 0.74 0.75 0.77 0.80 0.74 0.75 0.76 0.78 0.80 0.75 0.75 0.76 0.78 0.81
18.61 19.86 21.10 22.96 24.83 18.72 19.97 21.22 23.09 24.97 18.86 20.12 21.38 23.27 25.16 19.01 20.28 21.55 23.45 25.36
392.70 374.65 356.60 329.53 302.46 416.57 396.97 377.38 347.99 318.60 451.46 429.60 407.75 374.97 342.18 486.35 462.23 438.12 401.94 365.77
17.7 15.5 13.5 10.9 8.8 18.8 16.5 14.4 11.7 9.3 20.5 17.9 15.7 12.7 10.2 22.2 19.4 16.9 13.7 11.0
Units are complete packages containing two compressors with independent refirgeration circuits, reversing valves, expansion valve metering devices, and heat exchangers. Also included are safety controls: Overload protection for motors, high and low refrigerant pressure switches and a solid state lock-out circuit. Extended range option includes insulated water coils. Performance based on ARI/ISO rated air flow, fluid flow and voltage. For conditions other than rated, consult the FHP EAD selection software. Due to variations in installation actual performance may vary marginally from tabulated values. As a result of continuing research and development, specifications are subject to change without notice. EC300ip6 mod1 Rev: 05-11
EFT Range (Standard) 50oF to 80oF
EFT Range (Ext. Range Option) 25oF to 80oF
Entering Entering Fluid Air Total Power Temp. Temp. Capacity Input (oF) (oF) (MBtuH) (kW) o 317.56 22.84 50 362.27 24.24 60o 60o 406.98 25.64 70o 451.69 27.03 80o 300.28 23.25 50o 342.52 24.68 60o 70o 384.76 26.10 70o 427.00 27.53 80o 279.97 23.76 50o 319.31 25.22 60o 80o 358.65 26.68 70o 397.99 28.14 80o
LOW TEMP HEATING
25o 30o 40o 25o 30o 40o 25o 30o 40o
60o
70o
80o
201.75 223.66 267.50 190.85 211.56 252.97 178.06 197.34 235.91
Heat of Abs. COP (MBtuH) 239.60 4.1 279.54 4.4 319.48 4.7 359.42 4.9 220.91 3.8 258.29 4.1 295.66 4.3 333.04 4.5 198.86 3.5 233.23 3.7 267.59 3.9 301.95 4.1
Extended Range Option Required Antifreeze Required
19.35 20.05 21.44 19.69 20.40 21.83 20.12 20.85 22.31
135.72 155.25 194.31 123.64 141.92 178.47 109.39 126.19 159.78
3.1 3.3 3.7 2.8 3.0 3.4 2.6 2.8 3.1
FHP MANUFACTURING COMPANY 601 N.W. 65th Court - Fort Lauderdale, FL 33309 Phone: (954) 776-5471 - Fax: (800) 776-5529 http://www.fhp-mfg.com
EC360
2 STAGE VERTICAL PACKAGED UNITS
SPECIFICATION DATA SHEET
AQUARIUS SERIES
FHP MANUFACTURING HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS
ELECTRICAL SPECIFICATIONS
MECHANICAL SPECIFICATIONS
Loop Pump Electrical Elect. Compressor (x2) Blower (x2) Characteristics Symbol LRA FLA HP FLA HP RLA 208/230-3-60 -3 55.8 340.0 12.2 5 - - 460-3-60 -4 26.9 173.0 6.1 5 - - 575-3-60 -5 23.7 132.0 5.4 5
Min. Max. Circuit Fuse/ Amps Breaker 150.0 200 72.7 90 64.1 80
BLOWER PERFORMANCE Available External Static Pressure (Inches of Water, Gauge. Wet Coil and Filter Included) Blower 0.20 0.30 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.20 Speed Closed - - - - - - - - - - 12900 10800 1/2 Open - - - - - 13050 11850 10350 7500 Open 12200 11575 10950 9600 7800 - - - -
- -
- -
Refrigerant: R-410A Air Coil Square Rows Tube Fins/ Feet Deep O.D. Inch 27.0 3 3/8 14 Water Coil Type Work Press Coaxial 450 psig Blower Size Compr Type 15 x 15 BD Scroll Net Weight Ship Weight 1,650 lbs 1,750 lbs
FLUID PRESSURE DROP
- -
Fluid Pressure Flow Drop (GPM) (FOH) (PSIG) 50 8.5 3.7 70 15.6 6.8 80 19.8 8.6 90 24.5 10.6 100 29.6 12.8
PERFORMANCE DATA Rated in accordance with ISO 13256-1 at 12,000 CFM and 90.0 GPM Water Loop Ground Water Ground Loop (Ext. Range Required) Cooling Heating Cooling Heating Cooling Heating Capacity EER Capacity COP Capacity EER Capacity COP Capacity EER Capacity COP 386,000 14.8 435,000 4.4 472,000 22.0 342,000 4.0 412,000 16.4 252,000 3.3
CAPACITY DATA All performance at 12,000 CFM and 90.0 GPM EFT Range (Standard) 50oF to 100oF
COOLING
EFT Range (Ext. Range Option) 45oF to 110oF
HEATING
EFT Range (Standard) 50oF to 80oF
EFT Range (Ext. Range Option) 25oF to 80oF
Entering Entering Sensible Heat Fluid Air Total Sensible to Power of Temp. Temp. Capacity Capacity Total Input Reject EER (oF) (oF) (MBtuH) (MBtuH) Ratio (kW) (MBtuH)
Entering Entering Heat Fluid Air Total Power of Temp. Temp. Capacity Input Abs. COP (oF) (oF) (MBtuH) (kW) (MBtuH)
50o 60o 70o 85o 100o 50o 60o 70o 85o 100o 50o 60o 70o 85o 100o 50o 60o 70o 85o 100o
70 db 61owb o
75odb 63owb
80odb 67owb
85odb 71owb
410.51 382.97 355.43 314.12 272.81 440.77 411.30 381.82 337.60 293.38 485.05 452.74 420.42 371.94 323.47 529.33 494.17 459.02 406.29 353.56
266.82 250.73 235.39 213.26 191.49 321.51 302.36 284.08 257.71 231.78 356.31 335.19 315.05 285.99 257.41 391.45 368.36 346.33 314.55 283.30
0.65 0.65 0.66 0.68 0.70 0.73 0.74 0.74 0.76 0.79 0.73 0.74 0.75 0.77 0.80 0.74 0.75 0.75 0.77 0.80
23.92 25.62 27.31 29.86 32.40 24.03 25.74 27.44 30.00 32.56 24.18 25.91 27.63 30.21 32.79 24.34 26.07 27.81 30.41 33.01
492.15 470.40 448.65 416.03 383.40 522.79 499.14 475.48 440.00 404.52 567.59 541.15 514.71 475.04 435.38 612.39 583.16 553.93 510.09 466.24
17.2 14.9 13.0 10.5 8.4 18.3 16.0 13.9 11.3 9.0 20.1 17.5 15.2 12.3 9.9 21.7 19.0 16.5 13.4 10.7
Units are complete packages containing two compressors with independent refirgeration circuits, reversing valves, expansion valve metering devices, and heat exchangers. Also included are safety controls: Overload protection for motors, high and low refrigerant pressure switches and a solid state lock-out circuit. Extended range option includes insulated water coils. Performance based on ARI/ISO rated air flow, fluid flow and voltage. For conditions other than rated, consult the FHP EAD selection software. Due to variations in installation actual performance may vary marginally from tabulated values. As a result of continuing research and development, specifications are subject to change without notice. EC360ip6 mod1 Rev: 05-11
50o 60o 70o 80o 50o 60o 70o 80o 50o 60o 70o 80o
60o
70o
80o
377.81 430.94 484.08 537.22 358.00 408.20 458.40 508.60 334.73 381.48 428.24 474.99
LOW TEMP HEATING
25o 30o 40o 25o 30o 40o 25o 30o 40o
60o
70o
80o
240.16 266.21 318.30 227.94 252.54 301.76 213.57 236.49 282.33
29.21 31.14 33.06 34.99 29.67 31.63 33.59 35.55 30.23 32.23 34.24 36.25
278.10 324.67 371.24 417.81 256.74 300.25 343.76 387.27 231.56 271.47 311.37 351.28
3.8 4.1 4.3 4.5 3.5 3.8 4.0 4.2 3.2 3.5 3.7 3.8
Extended Range Option Required Antifreeze Required
24.40 25.37 27.29 24.77 25.75 27.71 25.21 26.21 28.22
156.87 179.63 225.16 143.41 164.67 207.20 127.53 147.02 186.01
2.9 3.1 3.4 2.7 2.9 3.2 2.5 2.6 2.9
FHP MANUFACTURING COMPANY 601 N.W. 65th Court - Fort Lauderdale, FL 33309 Phone: (954) 776-5471 - Fax: (800) 776-5529 http://www.fhp-mfg.com
Notes
601 N.W. 65th Court, Ft. Lauderdale, FL 33309 Phone: 954-776-5471 | Fax: 954-776-5529 www.boschtaxcredit.com | www.fhp-mfg.com