Preview only show first 10 pages with watermark. For full document please download

Bp1 2-6

   EMBED


Share

Transcript

Valve Regulated Lead-Acid Rechargeable Battery BP1.2-6 The battery is constructed by plates, separators, safety valves and container. Since the electrolyte is held by a glassmat separator and plates, the battery can be used in any direction and position without leakage. PERFORMANCE SPECIFICATIONS Nominal Voltage(V)...................................................................................................................6 volts(3cells in series) Nominal Capacity(AH) 20 hour rate F.V.(1.75V/cell) ( 60mA to 5.25volts)........................................................................................1.2A.H. 10 hour rate F.V.(1.75V/cell) (114mA to 5.25volts).....................................................................................1.14A.H. 5 hour rate F.V.(1.75V/cell) (204mA to 5.25volts) ....................................................................................1.02A.H. 1 hour rate F.V.(1.55V/cell) (720mA to 4.65volts).....................................................................................0.72A.H. Approximate Weight...............................................................................................................................300g(0.66lbs.) Terminal Standard.......................................................................................................................................................Type T1 Internal Resistance (Fully Charged Battery)....................................................................................................<65m Maximum Discharge Current For 5 sec.(A)............................................................................................................18A Maximum Charge Current(A)..............................................................................................................................0.36A Ambient Temperature Charge.................................................................................................................................0oC(32oF)~40oC(104oF) Discharge..........................................................................................................................-20oC(-4oF)~50oC(122oF) Storage..............................................................................................................................-20oC(-4oF)~40oC(104oF) Vibration test: Frequency: 16.7 HZ Amplitude: 4mm Vibrate the battery horizontally or vertically for 60 minutes. The battery have no abnormality. Case......................................................................................................................................................................ABS Dimension(mm/inch) Length 1.5mm..........................................................................................................................97/3.82 Width 1.5mm..........................................................................................................................25/0.98 Container Height 1.5mm..........................................................................................................................51/2.01 Total Height 2mm.............................................................................................................................56/2.20 Application.............................................Security & Burglar Alarm Systems & Equipment, Guide Lights, Transceiver. BP1.2-6 Battery discharge characteristics (25°C/77°F) Battery Charging Characteristics (Typical example of the charge characteristic for the standby use) 5.50 0.204A 0.114A 0.06A 0.3A 5.00 0.72A 4.50 4.00 3.6A 3.50 1 2 3 5 10 2.4A 0.21 7.50 120 0.18 7.00 0.15 6.50 100 80 60 40 For cycle service 0 0 C ha rg e 6.00 20 30 1 Discharge 100%(0.05CA 20h) 50%(0.05CA 10h) 2 Constant voltage charging Charge voltage:2.275V/cell Charge current:0.1CA 3 Temperature 20°C(68°F) 5.50 5.00 60 2 3 5 10 20 0 30 0 5 10 20 25 Effect of Temperature on Long Term Float Life 10 8 Temperature Charging Max. charging compensation Voltage current coefficient of at 20OC (CA) charging voltage (V/cell) O (mV/ C/cell) -3 0.3 Charging time O 0.1CA, 20 C (h) 100% discharge Temp ( OC) 50% discharge 24 20 0~40 O (32~104 F) 2.40~2.50 15 Charge time (hr) Hr 2.25~2.30 vo lu m e Charge current -4 0.3 16 6 5 4 Life expectancy(year) Constant voltage & Constant current charging (with current restriction) 0.06 0.03 Charging Procedure For standby power Source 0.09 20 Discharge time Charging method 0.12 Charge voltage 1.2A Min Application Charge voltage(V) Charge volume(%) Terminal Voltage(V) 6.00 140 Charging current(CA) 6.50 Charging voltage : 2.275V/cell 3 2 1 10 O 0.5 O *Temperature compensation of charging voltage is not needed, when using the batteries within 5 C to 35 C range. 20 68 TERMINAL TYPE Terminal T1 50 oC 122 oF 40 104 Battery temperature mm(inch) OUTER DIMENSIONS 30 86 Constant power discharge characteristics at 25 oC/77 oF 3.2(0.13) 4.75(0.19) Discharge time Final Voltage 5Min 10Min 15Min 30Min 1Hr 3Hr 5Hr 10Hr 20Hr Battery output power(W) 0.8(0.03) 6.35(0.25) 5.40V 21.7 16.0 12.8 7.6 4.37 1.75 1.21 0.67 0.35 5.25V 25.1 17.3 13.4 7.9 4.50 1.78 1.22 0.68 0.36 5.10V 26.7 17.9 13.8 8.1 4.58 1.80 1.23 0.69 0.36 4.95V 27.9 18.4 14.1 8.2 4.63 1.81 1.23 0.69 0.36 4.80V 28.8 18.7 14.4 8.3 4.68 1.82 1.24 0.69 0.36 25 1.5(0.98 0.06) USA: B&B BATTERY(USA) INC. 6415 RANDOLPH ST.COMMERCE, CA,90040 U.S.A. TEL:1-323-278-1900.1-800-278-8599 FAX:1-323-278-1268 E-Mail:[email protected] EUROPE: B&B BATTERY(EUROPE) B.V. 3 WIJNGAARDVELD, 9300 AALST,BELGIUM TEL:(00)32-53781567 FAX:(00)32-53781567 E-Mail:[email protected] 56 2(2.20 0.08) 51 1.5(2.01 0.06) 97 1.5(3.82 0.06) TERMINAL POSITION RAOPING, GUANG DONG,CHINA,515700 TEL:86-768-7601001-2 FAX:86-768-7601469 E-Mail:[email protected] JAPAN: B&B BATTERY(JAPAN) CO., LTD. 1375-11 NARAHARA-MACHI,HACHIOJI, TOKYO 193-0803,JAPAN. TEL:81-426-25-6375 FAX:81-426-25-6375 E-Mail:[email protected] HONG KONG: NATIONAL TRADING LTD. TEL:852-2301-3800 FAX:852-2739-1182 E-Mail:[email protected] TAIWAN: B.B. BATTERY(TAIWAN) CO., LTD. TEL:886-6-502-5150 FAX:886-6-589-8087 E-Mail:[email protected] CHINA FACTORY: REV. Jun. 2005