Valve Regulated Lead-Acid Rechargeable Battery BP7-12 The battery is constructed by plates, separators, safety valves and container. Since the electrolyte is held by a glassmat separator and plates, the battery can be used in any direction and position without leakage. PERFORMANCE SPECIFICATIONS Nominal Voltage(V).................................................................................................................................12 volts(6cells in series) Nominal Capacity(AH) 20 hour rate F.V.(1.75V/cell) (350mA to 10.50volts) ..................................................................................................7.0A.H. 10 hour rate F.V.(1.75V/cell) (665mA to 10.50volts) .............................................................................................6.65A.H. 5 hour rate F.V.(1.75V/cell) (1190mA to 10.50volts) ...............................................................................................5.95A.H. 1 hour rate F.V.(1.55V/cell) (4200mA to 9.30volts)....................................................................................................4.2A.H. Approximate Weight.............................................................................................................................................2540g.(5.60lbs.) Terminal Standard.........................................................................................................................................................................Type T2 Optional...........................................................................................................................................................................Type T1 Internal Resistance (Fully Charged Battery)....................................................................................................................<25m Maximum Discharge Current For 5 sec.(A).........................................................................................................................105A Maximum Charge Current(A).................................................................................................................................................2.1A Ambient Temperature Charge...................................................................................................................................................0oC(32oF)~40oC(104oF) Discharge............................................................................................................................................-20oC(-4oF)~50oC(122oF) Storage................................................................................................................................................-20oC(-4oF)~40oC(104oF) Vibration test: Frequency: 16.7HZ Amplitude: 4mm Vibrate the battery horizontally or vertically for 60 minutes. The battery have no abnormality. Case..........................................................................................................................................................................................ABS Dimension(mm/inch) Length 1.5mm...........................................................................................................................................151/5.94 Width 1.5mm.............................................................................................................................................65/2.56 Container Height 1.5mm.............................................................................................................................................93/3.66 Total Height 2mm................................................................................................................................................98/3.86 Application....................................................................UPS.Laboratory Equipment, Toy-Cars, Power Packs, Fishing Lights. BP7-12 Battery discharge characteristics (25°C/77°F) Battery Charging Characteristics (Typical example of the charge characteristics for the standby use) Terminal Voltage(V) 11.0 1.19A 0.665A 0.35A 1.75A 10.0 4.2A 9.0 8.0 21A 14A 0.21 15.0 120 0.18 14.0 100 0.15 13.0 80 60 40 Charge voltage(V) Charge volume(%) 12.0 140 Charge current(CA) 13.0 0.12 0.09 0.06 20 0.03 0 0 Charge voltage C ha rg e 1 Discharge 100 %(0.05CA X 20h) 50 %(0.05CA X 10h) 2 Constant voltage charging Charge voltage:2.275V/cell Charge current:0.1CA 3 Temperature:20°C(68°F) 12.0 11.0 10.0 Charge current 7A 0 0 7.0 1 2 3 5 10 20 30 60 2 3 5 10 20 15 20 25 Charge time (hr) Effect of Temperature on Long Term Float Life 10 8 Charging Procedure Temperature Charging compensation Voltage coefficient of O at 20 C voltage (V/cell) charging (mV/ OC/cell) 2.25~2.30 Charging time O 0.1CA, 20 C (h) Max. charging current (CA) 100% discharge 24 0.3 -3 Temp O ( C) 50% discharge 20 0~40 O (32~104 F) 2.40~2.50 0.3 -4 16 6 5 4 Life expectancy(year) Constant For standby voltage & power Source Constant current charging For (with current cycle service restriction) 10 30 Discharge time Charging method 5 Hr Min Application vo lu m e Charging voltage : 2.275V/cell 3 2 1 10 0.5 O 20 68 O *Temperature compensation of charging voltage is not needed, when using the batteries within 5 C to 35 C range. o mm(inch) Terminal T1 0.06) 65 1.5(2.56 USA: B&B BATTERY(USA) INC. 6415 RANDOLPH ST.COMMERCE, CA,90040 U.S.A. TEL:1-323-278-1900.1-800-278-8599 FAX:1-323-278-1268 E-Mail:[email protected] EUROPE: B&B BATTERY(EUROPE) B.V. 3 WIJNGAARDVELD, 9300 AALST,BELGIUM TEL:(00)32-53781567 FAX:(00)32-53781567 E-Mail:[email protected] Final Voltage 6.35(0.25) 4.75(0.19) 1.5(5.94 5Min 10Min 15Min 30Min 1Hr 3Hr 5Hr 10Hr 20Hr Battery output power(W) 0.8(0.03) 7.85(0.31) 0.06) 10.80V 253.1 186.3 149.3 88.8 50.95 20.40 14.07 7.86 4.11 10.50V 292.9 201.8 156.2 92.2 52.47 20.81 14.28 7.98 4.20 10.20V 311.2 209.1 161.0 94.3 53.42 21.00 14.36 8.02 4.22 9.90V 325.2 214.1 164.7 95.6 54.06 21.15 14.41 8.04 4.23 9.60V 336.0 218.4 168.0 96.6 54.60 21.27 14.45 8.04 4.23 TERMINAL POSITION 93 1.5(3.66 0.06) 98 2(3.86 0.06) 151 Discharge time Terminal T2 0.8(0.03) 6.35(0.25) o Constant power discharge characteristics at 25 C/77 F 3.4(0.13) 3.2(0.13) 50 oC 122 oF 40 104 Battery temperature TERMINAL TYPE OUTER DIMENSIONS 30 86 RAOPING, GUANG DONG,CHINA,515700 TEL:86-768-7601001-2 FAX:86-768-7601469 E-Mail:[email protected] JAPAN: B&B BATTERY(JAPAN) CO., LTD. 1375-11 NARAHARA-MACHI,HACHIOJI, TOKYO 193-0803,JAPAN. TEL:81-426-25-6375 FAX:81-426-25-6375 E-Mail:[email protected] HONG KONG: NATIONAL TRADING LTD. TEL:852-2301-3800 FAX:852-2739-1182 E-Mail:[email protected] TAIWAN: B.B. BATTERY(TAIWAN) CO., LTD. TEL:886-6-502-5150 FAX:886-6-589-8087 E-Mail:[email protected] CHINA FACTORY: REV. Jun. 2005