Preview only show first 10 pages with watermark. For full document please download

@br@/@er@ G3vm-

   EMBED


Share

Transcript

Introduction General-purpose G3VM-@BR@/@ER@ MOS FET Relays DIP 6-pin, High-current and Low-ON-resistance Type High-load-voltage Small and HighMulti-contact-pair High-current and (2a, 2b, and 1a1b) Low-ON-resistance dielectric-strength MOS FET Relays in DIP 6-pin packages that achieve the low ON resistance and high switching capacity of a mechanical relay • Load voltage: 20 V, 40 V, 60 V, or 100 V • 20-V Relay: Continuous load current of 4 A (8 A) max. * • 40-V Relay: Continuous load current of 3.5 A (7 A) max. * • 60-V G3VM-61BR/ER Relay: Continuous load current of 2.5 A max. • 60-V G3VM-61BR1/ER1 Relay: Continuous load current of 3 A (6 A) max. * • 100-V Relay: Continuous load current of 2 A (4 A) max. * * Values in parentheses are for connection C. RoHS Compliant ■Application Examples High-dielectricstrength • Communication equipment • Security equipment • Test & Measurement equipment • Industrial equipment Current-limiting Low-output-capacitance and Low-ON-resistance ■Package • Power circuit ■Model Number Legend (Unit : mm, Average) G3V M- @ @ @ @ @ DIP 6-pin PCB Terminals 1 2 3 4 5 7.12 Small and Highload-voltage 1. Load Voltage 2 : 20 V 4 : 40 V 6 : 60 V 10 : 100 V 3.65 6.4 Surface-mounting Terminals 2. Contact form 1 : 1a (SPST-NO) 4. Additional functions R: Low ON resistance 7.12 3.65 6.4 Certified Models with Standards Certification DIP SOP SSOP USOP VSON Note: The actual product is marked differently from the image shown here. 3. Package B : DIP 6-pin with PCB terminals E : DIP 6-pin with surface-mounting terminals 5. Other informations When specifications overlap, serial code is added in the recorded order. Note: The actual product is marked differently from the image shown here. ■Ordering Information G3VM-@BR@/@ER@ Package Contact form DIP6 1a (SPST-NO) Stick packaging Continuous load current (peak value) * Load voltage Model (peak value) * Connection Connection Surface-mounting PCB Terminals A, B C Terminals Tape packaging Minimum package quantity Surface-mounting Terminals 20 V 4A 8A G3VM-21BR G3VM-21ER G3VM-21ER(TR) 40 V 3.5 A 7A G3VM-41BR G3VM-41ER G3VM-41ER(TR) 2.5 A − G3VM-61BR G3VM-61ER 3A 6A G3VM-61BR1 G3VM-61ER1 G3VM-61ER1(TR) 2A 4A G3VM-101BR G3VM-101ER G3VM-101ER(TR) 60 V 100 V 50 pcs. * The AC peak and DC value are given for the load voltage and continuous load current. Note: To order tape packaging for Relays with surface-mounting terminals, add “(TR)” to the end of the model number. 108 Model G3VM-61ER(TR) Minimum package quantity 1,500 pcs. MOS FET Relays Item Symbol Repetitive peak LED forward current LED forward current reduction rate G3VM-21BR G3VM-21ER G3VM-61BR G3VM-61ER G3VM-61BR1 G3VM-101BR G3VM-61ER1 G3VM-101ER 30 Unit IFP 1 A -0.3 mA/°C LED reverse voltage VR 5 V Connection temperature TJ 125 °C 20 40 4 3.5 IO Connection B Connection C ON current reduction rate Connection A Connection B ΔIO/°C Connection C Pulse ON current lop 8 7 -40 -35 -80 -70 12 10.5 60 2.5 − -22 − 7.5 100 3 2 6 4 -30 -20 -60 -40 9 6 100 μs pulses, 100 pps Ta ≥ 25°C V A mA/°C A Connection A: AC peak/DC Connection B and C: DC Ta ≥ 25°C t=100 ms, Duty=1/10 Connection temperature TJ 125 °C Dielectric strength between I/O (See note 1.) VI-O 2,500 Vrms Ambient operating temperature Ta -40 to +85 -20 to +85 -40 to +85 °C Tstg -55 to +125 -40 to +125 -55 to +125 °C With no icing or condensation °C 10 s Ambient storage temperature − Soldering temperature 260 AC for 1 min Connection Diagram Connection A 5 3 4 1 6 2 5 3 4 1 6 2 5 3 4 Load AC or DC Load DC Low-output-capacitance and Low-ON-resistance Connection C 6 2 Current-limiting Connection B 1 High-dielectricstrength Note: 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. Small and HighMulti-contact-pair High-current and (2a, 2b, and 1a1b) Low-ON-resistance dielectric-strength VOFF Connection A Continuous load current Measurement conditions mA ΔIF/°C Load voltage (AC peak/DC) Output G3VM-41BR G3VM-41ER IF High-load-voltage Input LED forward current General-purpose ■Absolute Maximum Ratings (Ta = 25°C) Introduction G3VM-@BR@/@ER@ Load DC Small and Highload-voltage Note: Only connection A can be used for the G3VM-61BR/ER. Certified Models with Standards Certification DIP SOP SSOP USOP VSON G3VM-@BR@/@ER@ 109 MOS FET Relays Item G3VM-21BR G3VM-41BR G3VM-61BR G3VM-61BR1G3VM-101BR Unit G3VM-21ER G3VM-41ER G3VM-61ER G3VM-61ER1 G3VM-101ER Symbol Minimum High-load-voltage LED forward voltage Input General-purpose ■Electrical Characteristics (Ta = 25°C) Small and HighMulti-contact-pair High-current and (2a, 2b, and 1a1b) Low-ON-resistance dielectric-strength Output Introduction High-dielectricstrength Current-limiting Low-output-capacitance and Low-ON-resistance Small and Highload-voltage Certified Models with Standards Certification DIP SOP SSOP USOP VSON G3VM-@BR@/@ER@ VF Measurement conditions 1.18 Typical 1.33 Maximum 1.48 V IF=10 mA Reverse current IR Maximum 10 μA VR=5 V Capacitance between terminals CT Typical 70 pF V=0, f=1 MHz Trigger LED forward current IFT Release LED forward current IFC Maximum resistance with output ON Typical 0.5 1 0.1 Typical 20 ILEAK 40 100 100 70 200 20 50 50 60 10 15 Typical Capacitance between terminals 65 Typical Connection C mA 30 Maximum RON Current leakage when the relay is open 3 Minimum Connection A Connection B 0.5 mA IO=1 A Maximum 5 − 8 10 25 Typical − 0.001 − Maximum 1 0.01 1 1000 400 1000 COFF Typical Capacitance between I/O terminals CI-O Typical 0.8 Insulation resistance between I/O terminals RI-O Minimum 1000 Typical 108 Turn-ON time tON Turn-OFF time tOFF Typical 2.5 2 IOFF=10 μA G3VM-21BR/21ER/41BR/41ER/ 61BR1/61ER1/101BR/101ER : IF=5 mA, mΩ IO=2 A (Connection A and B), IO=4 A (Connection C), t<1 s G3VM-61BR/ER : IF=10 mA, t=10 ms, IO=2 A μA VOFF=Load voltage ratings pF V=0, f=1 MHz pF f=1 MHz, VS=0 V MΩ VI-O=500 VDC, ROH≤60% 1 2 Maximum 5 1.5 5 Typical 0.1 0.2 0.1 Maximum 1 0.4 1 ms G3VM-21BR/21ER/41BR/41ER/ 61BR1/61ER1/101BR/101ER : IF=5 mA, RL=200 Ω, VDD=20 V (See note 2.) G3VM-61BR/ER : IF=10 mA, RL=200 Ω, VDD=20 V (See note 2.) Note: 2. Turn-ON and Turn-OFF Times IF 1 6 2 4 RL VDD VOUT IF VOUT 10% 90% t ON t OFF ■Recommended Operating Conditions For usage with high reliability, Recommended Operation Conditions is a measure that takes into account the derating of Absolute Maximum Ratings and Electrical Characteristics. Each item on this list is an independent condition, so it is not simultaneously satisfy several conditions. Item Symbol Load voltage (AC peak/DC) VDD Maximum G3VM-21BR G3VM-21ER G3VM-41BR G3VM-41ER 16 32 Minimum G3VM-@BR@/@ER@ Operating LED forward current IF Continuous load current (AC peak/DC) IO Ambient operating temperature Ta 5 Typical Maximum Minimum Maximum ■Spacing and Insulation Item Minimum Creepage distances 7.0 Clearance distances 7.0 Internal isolation thickness 0.4 110 Unit mm 2.5 60 V mA 25 3 2 -20 65 Unit 80 10 20 3.5 G3VM-101BR G3VM-101ER 5 − 25 4 G3VM-61BR1 G3VM-61ER1 48 10 10 Maximum G3VM-61BR G3VM-61ER 65 A °C MOS FET Relays 25 20 15 10 15 10 1 G3VM-21BR/21ER/41BR/41ER 61BR1/61ER1/101BR/101ER 0.1 0 0 -20 20 40 60 80 100 Ambient temperature Ta (°C) 6 5 G3VM-21ER/ER: Connection A, B 4 3 2 G3VM-101BR/ER: Connection C 6 5 4 G3VM-21ER/ER: Connection A, B 1.6 IO - Ta 10 9 8 7 6 5 4 3 2 1 1 G3VM-41BR/ER: Connection A, B 0 0 G3VM-61BR/ER G3VM-101BR/ER -2 20 40 60 80 100 Ambient temperature Ta (°C) -5 -0.2 G3VM-101BR/ER G3VM-61BR/ER 100 G3VM-61BR1/ER1 50 G3VM-41BR/ER G3VM-21BR/ER G3VM-21BR/ER -0.1 0 0.1 0.2 On-state voltage VON (V) -40 20 -20 0 20 40 40 60 80 100 Ambient temperature Ta (°C) IFT - Ta G3VM-61BR/ER: IO=2A, IF=10mA The others: IO=2A, IF=5mA, t<1s, Connection A 0 0 RON - Ta 150 -3 -4 -20 ● Trigger LED forward current vs. Ambient temperature 3.5 3 2.5 G3VM-61BR/ER: G3VM-61BR/ER IO=2A The others: IO=1A, t<1s, Connection A 2 G3VM-61BR1/ER1 1.5 G3VM-41BR/ER 1 0.5 G3VM-21BR/ER G3VM-41BR/ER 60 80 100 Ambient temperature Ta (°C) 0 G3VM-101BR/ER -40 -20 0 20 40 60 80 100 Ambient temperature Ta (°C) Certified Models with Standards Certification -1 On-state resistance RON (mΩ) G3VM-61BR1/ER1 0 0 Small and Highload-voltage G3VM-61BR/ER: Ta=25°C, IF=10mA The others: Ta=25°C, IF=5mA, Connection A -20 ● On-state resistance vs. Ambient temperature IO - VON 5 0 -40 Low-output-capacitance and Low-ON-resistance 20 40 60 80 100 Ambient temperature Ta (°C) Trigger LED forward current IFT (mA) -20 ● Continuous load current vs. On-state voltage 1 G3VM-61BR1/ER1: Connection C 2 -40 2 1.4 G3VM-41BR/ER: Connection A, B 0 3 1.2 G3VM-61BR/61ER 8 3 1 LED forward voltage VF (V) 9 7 0.8 Current-limiting Continuous load current IO (A) G3VM-21BR/ER: Connection C G3VM-41BR/ER: Connection C 0.01 IO - Ta 10 7 4 40 60 80 100 Ambient temperature Ta (°C) G3VM-61BR1/61ER1/101BR/101ER 9 1 20 IO - Ta 10 8 0 Continuous load current IO (A) -20 High-dielectricstrength Continuous load current IO (A) 20 G3VM-61BR/ER 5 -40 ● Continuous load current vs. Ambient temperature G3VM-21BR/21ER/41BR/41ER Continuous load current IO (A) 25 Ta=25°C 10 5 0 30 IF - VF 100 LED forward current IF (mA) LED forward current IF (mA) 30 IF - Ta 35 Small and HighMulti-contact-pair High-current and (2a, 2b, and 1a1b) Low-ON-resistance dielectric-strength LED forward current IF (mA) IF - Ta 35 ● LED forward current vs. LED forward voltage G3VM-61BR/61ER High-load-voltage ● LED forward current vs. Ambient temperature G3VM-21BR/21ER/41BR/41ER/ 61BR1/61ER1/101BR/101ER General-purpose ■Engineering Data Introduction G3VM-@BR@/@ER@ DIP SOP SSOP USOP VSON G3VM-@BR@/@ER@ 111 MOS FET Relays ● Turn ON, Turn OFF time vs. LED forward current G3VM-21BR/21ER/41BR/41ER G3VM-61BR/61ER/61BR1/61ER1/101BR/101ER VDD=20V, RL=200Ω, Ta=25°C G3VM-41BR/ER Small and HighMulti-contact-pair High-current and (2a, 2b, and 1a1b) Low-ON-resistance dielectric-strength 1 tON tOFF G3VM-21BR/ER 0.1 G3VM-41BR/ER 100 VDD=20V, RL=200Ω, Ta=25°C G3VM-61BR1/ER1 10 tON G3VM-101BR/ER 1 tOFF 0.1 G3VM-101BR/ER G3VM-61BR1/ER1 0.01 0.01 1 1 10 100 LED forward current IF (mA) ● Turn ON, Turn OFF time vs. Ambient temperature G3VM-21BR/21ER/41BR/41ER 10 100 LED forward current IF (mA) G3VM-61BR/61ER/61BR1/61ER1/101BR/101ER tON, tOFF - Ta VDD=20V, RL=200Ω, IF=5mA tON G3VM-41BR/ER High-dielectricstrength 1 G3VM-21BR/ER 0.1 tOFF Current-limiting Low-output-capacitance and Low-ON-resistance G3VM-41BR/ER -20 0 20 40 60 80 100 10 VDD=20V, RL=200Ω, IF=5mA G3VM-61BR1/ER1 tON 1 G3VM-101BR/ER G3VM-61BR/ER tOFF G3VM-101BR/ER 0.1 tOFF 0.01 -40 -20 Ambient temperature Ta (°C) 0 ILEAK - Ta 100 VOFF=Load voltage ratings G3VM-21BR/ER G3VM-101BR/ER 10 G3VM-61BR1/ER1 G3VM-61BR/ER 1 0.1 G3VM-61BR1/ER1 G3VM-41BR/ER 0.01 -20 20 40 60 80 100 Ambient temperature Ta(°C) 0 20 40 60 80 Ambient temperature Ta (°C) ■Appearance / Terminal Arrangement / Internal Connections ●Appearance Small and Highload-voltage ●Terminal Arrangement/Internal Connections (Top View) DIP (Dual Inline Package) DIP 6-pin G3VM-21BR/ER, -41BR/ER, -61BR1/ER1, -101BR/ER G3VM-21BR/ER, -41BR/ER, -61BR1/ER1, -101BR/ER Mold pin mark (See note 3.) Certified Models with Standards Certification DIP SOP SSOP USOP VSON ● Current leakage vs. Ambient temperature tON, tOFF - Ta 10 0.01 -40 tON tOFF G3VM-61BR/ER Current leakage ILEAK (nA) 10 Turn ON, Turn OFF time tON, tOFF (ms) 100 Turn ON, Turn OFF time tON, tOFF (ms) High-load-voltage tON, tOFF - IF tON, tOFF - IF Turn ON, Turn OFF time tON, tOFF (ms) General-purpose ■Engineering Data Turn ON, Turn OFF time tON, tOFF (ms) Introduction G3VM-@BR@/@ER@ 6 5 4 1 2 3 OMRON logo Model name (See note 2.) 932 Pin 1 mark LOT.NO. Special DIP 6-pin * G3VM-61BR/ER G3VM-61BR/ER 6 4 Mold pin mark (See note 3.) OMRON logo Model name (See note 2.) G3VM-@BR@/@ER@ 6 Pin 1 mark 932 LOT.NO. 1 Note: 1. The actual product is marked differently from the image shown here. Note: 2. “G3VM” does not appear in the model number on the Relay. Note: 3. The indentation in the corner diagonally opposite from the pin 1 mark is from a pin on the mold. * The external dimensions of the standard DIP 6-pin are the same, but the number of terminals is different. 112 2 3 MOS FET Relays G3VM-21BR/41BR/61BR1/101BR General-purpose ■Dimensions (Unit: mm) G3VM-21ER/41ER/61ER1/101ER Surface-mounting Terminals PCB Dimensions (BOTTOM VIEW) PCB Terminals Weight: 0.4 g Weight: 0.4 g 2.54 Six, 0.8-dia. holes High-load-voltage (0.61) 2.54 7.12±0.25 7.12±0.25 (0.61) (1.52) (1.52) 6.4±0.25 Actual Mounting Pad Dimensions 7.62±0.25 0.8±0.25 (Recommended Value, Top View) 7.62±0.25 3.65+0.15 -0.25 2.54 0.25+0.1 -0.05 1.2±0.15 2.5 min. 3.65+0.15 -0.25 7.85 to 8.80 0.5±0.1 2.54±0.25 2.54 4.0+0.25 -0.2 1.0 min. 8.3 to 8.8 1.2±0.15 1.0 min. 10.0 max. 2.54±0.25 1.3 1.5 Note: The actual product is marked differently from the image shown here. G3VM-61BR G3VM-61ER PCB Terminals Surface-mounting Terminals PCB Dimensions (BOTTOM VIEW) Weight: 0.4 g Weight: 0.4 g 2.54 Six, 0.8-dia. holes (0.61) 2.54 7.12±0.25 7.12±0.25 6.4±0.25 Actual Mounting Pad Dimensions 7.62±0.25 3.65+0.15 -0.25 1.2±0.15 0.5±0.1 2.54±0.25 3.65+0.15 -0.25 1.0 min. 1.2±0.15 7.85 to 8.80 2.54±0.25 2.54 4.0+0.25 -0.2 1.0 min. 2.54 Current-limiting 0.25+0.1 -0.05 2.5 min. (Recommended Value, Top View) 7.62±0.25 0.8±0.25 8.3 to 8.8 10.0 max. 1.3 1.5 Low-output-capacitance and Low-ON-resistance Note: The actual product is marked differently from the image shown here. ■Approved Standards UL recognized Contact form File No. UL (recognized) 1a (SPST-NO) E80555 Small and Highload-voltage Approved Standards High-dielectricstrength (0.61) (1.52) (1.52) 6.4±0.25 Small and HighMulti-contact-pair High-current and (2a, 2b, and 1a1b) Low-ON-resistance dielectric-strength 6.4±0.25 Introduction G3VM-@BR@/@ER@ Certified Models with Standards Certification ■Safety Precautions • Refer to the Common Precautions for All MOS FET Relays for precautions that apply to all MOS FET Relays. DIP SOP SSOP USOP VSON G3VM-@BR@/@ER@ 113