Preview only show first 10 pages with watermark. For full document please download

Brand-rex Copper Cables - 10gplus Augmented

   EMBED


Share

Transcript

ugmented at e g o r y 6 S y t e m AC6 500MHz Sheath ross iller Cable Standards he cable is compliant with: • ISO 61156-5 ed 2, ANSI/TIA/EIA 568C and the draft standard EN 50288-11-1 23 W W olyolefin nsulation he cable is fully backwards compatible with ategory 5 and ategory 6 systems Independent 3rd Party Certification (3P) Brand-Rex Copper Cables - 10GPlus Communication Cable, U/UTP, 100 Ω, 4x2,AWG23/1 Electrical Characteristics @ 20°c Specification Typical Performance onductor oop esistance onductor esistance nbalance ielectric Strength nsulation esistance apacitance nbalance to arth Velocity of ropagation Skew ean haracteristic mpendance oupling ttenuation up to 1 hz ax 19Ω / 100m ax 2% 1.0kV dc or 0.7kV ac for 1 min >500 Ω.km @ 100-500 V test voltage <120 pF/100m <534 nsec/100m @ 100Mhz Max 40ns/100m @ 100Mhz 100+/-5 Ω @ 100 hz in 40d ax 19Ω / 100m 0.5% 100% in process test >5 Ω.km 40 pF/100m <490 nsec/100m @ 100Mhz (NVP for hand testers = 0.67) Max 30ns/100m @ 100Mhz 100+/-5 Ω @100 hz 56d Characteristic Typical Headroom vs (250MHz) Typical Headroom vs AC6 (500MHz) Return Loss Insertion Loss NEXT PSNEXT ELFEXT PSELFEXT PSANEXT PSAELFEXT 5d 6% 10d 10d 12d 12d 5d 2% 10d 20d 12d 12d 5d 6d PRODUCT DESCRIPTION 10GPlus U/UTP, 100 Ω, 4x2,AWG23/1 is a premium grade Class EA / Augmented ategory 6 cable to support 10 igabit thernet protocol for installation in horizontal and backbone applications. PRODUCT PERFORMANCE Core onductor: 23 W lain nnealed opper Wire nsulation: olyolefin iameter: 1.06mm ominal air: 2 of the above cores air olour: lue - White, range - White reen - White, rown - White Final Assembly able: Typical headroom on key S/N characteristics - for information only Typical Headroom vs Cat6 (250MHz) Sheath: Typical Headroom vs AC6 (500MHz) 0d 13d PSACR-N @ 500MHz PSAACR-N* @ 500MHz Mechanical and Environmental emp - nstallation: 0 to 50 emp - peration: -20 to 75 ax ensile oad: 10kg per cable in end adius: 8 x ffective iameter (installation) in end - peration: 4 x ffective iameter (operation) * ower Sum ttenuation to lien rosstalk (near end) atio he lien crosstalk performance of cables is assessed using a ‘6 round 1’ or ‘4 on a drum’ method. Product Part Numbering Part Number Length (m) 6 - 1-500V 500 6 - 1-1000V 1000 6 - 3-500 500 6 - 3-1000 1000 Fire Safety Rating Colour Nominal Cable Diameter (mm) Nominal Weight (Kg/Km) Calorific Value kWh/m S Violet 8.5 79 0.32 60332-1-2 S lue 8.5 81 0.42 60332-3-24 Cable type 4 of the above pairs cabled together around a cross filler S compound alogen ree cable types ( S and 61034 ) meet 60754-2