Transcript
BRIGON DM485 True RMS Digital Multimeter The DM 485 is a safety and rugged True RMS industrial Digital Multimeter perfect for HVAC and electrical technicians whose applications require consistent accuracy ●
Fully loaded True RMS Digital Multimeter
●
3-3/4 Digit LCD with back light and bar graph
●
Data Hold Function
●
MIN / MAX Peak
●
Auto & Manual Ranging
●
Shock proof protective rubber boot with holder for test leads
●
CATIII 1000V, CATIV 600V
Measuring Functions ● 1000 V AC/DC ●
10 A AC/DC
●
2000 µA Microamp AC/DC
●
40 MΩ Resistance
●
4000 µF Capacitance
●
Frequency / Duty cycle
●
- 50° ... + 1000 °C Temperature
●
Diode test
Scope of delivery
Why is True RMS so important: When measuring the value of an alternating current signal (AC) most hand held digital multimeters convert the signal into an average value and apply a correction factor. Average values are only accurate, if the input sinusoidal signal is stable and unchanging. However perfect sine waves are rare in most industrial and commercial applications. True RMS multimeters deliver more accurate AC measurements using the principle based on the laws of physics: the current, passing through a resistive load, dissipates energy in the form of heat. If the resistive load is a heating element and it remains constant, then the heat produced will be directly proportionate to the current passing through the load. Thus True RMS multimeters measure the heat dissipated by a constant resistive load and apply several formulas to calculate True RMS current value. Due to various disturbances and faults the deviation between True RMS and average current measurement may reach 40 % of the value.
Item
6560
BRIGON DM485 True RMS Digital Multimeter includes test leads, alligator clips, type K probe and batteries
BRIGON Messtechnik GmbH • Kronberger St. 11 • 63110 Rodgau • Germany Tel. + 49 (0) 6106 8207 0 • Fax + 49 (0) 6106 8207 40 • e-mail:
[email protected] • Internet: www.brigon.de Changes also technical changes without prior notice
16042 Rev. 0 / 22.02.2012
BRIGON DM485 True RMS Digital Multimeter Technical Data Measuring range AC Current Measurement
400 µA ... 400 mA
Resolution
Accuracy
0,01 µA ... 0,1 mA
± (1,2% + 5 digit) (40...400 Hz)
Overload protection 400 mA / 1000 V RMS
± (2,0% + 5 digit) (400 Hz...10 kHz)
(40 - 10 kHz) True RMS 4 A ... 10 A
1 mA ... 10 mA
± (1,8% + 5 digit) (40...400 Hz)
10 A / 1000 V RMS
± (2,5% + 10 digit) (400 Hz...10 kHz) AC Voltage Measurement
400 mV
0,1 mV
± (0,75% + 5 digit) (40...400 Hz)
1000 V RMS
± (2,5% + 10 digit) (400 Hz...20 kHz)
(40 - 20 kHz) True RMS 4 V ... 400 V
1 mV ... 100 mV
Input impedance > 10 MΩ
± (2,0% + 8 digit) (400 Hz...20 kHz) 1000 V
1V
< 100 pF DC Current Measurement
± (0,75% + 5 digit) (40...400 Hz)
± (0,75% + 8 digit) (40...400 Hz) ± (2,0% + 8 digit) (400 Hz... 1 kHz)
400 µA ... 400 mA
0,1 µA ... 0,1 mA
± (1,0% + 5 digit)
400 mA / 1000 V RMS
4 A ... 10 A
1 mA ... 10 mA
± (1,5% + 5 digit)
10 A / 1000 V RMS
400 mV
0,1 mV
± (0,5% + 4 digit)
1000 V
4V
1 mV
> 10 MΩ
40 V
10 mV
< 100 pF
400 V
100 mV
DC Voltage Measurement Input impedance
1000 V
1V
± (0,8% + 10 digit)
400 Ω ... 4 MΩ
100 mΩ ... 1 kΩ
± (1,0% + 5 digit)
40 MΩ
10 kΩ
± (1,5% + 10 digit)
Diode test
2,0 V
< 1,6 V DC
Capacitance
40 nF
0,01 nF
Resistance Measurement
600 V RMS
600 V RMS ± (3,5% + 6 digit)
600 V RMS
Measurement
400 nF ... 4000 µF
0,1 nF ... 1 µF
Frequency Measurement
9,999 Hz ... 999,9 kHz
0,001 Hz ... 0,1 kHz
± (0,1% + 4 digit)
600 V RMS
Temperature Measurement
- 50 ... +1000 °C
0,1 ... 1 °C
± (3,0 % + 3,0 °C)
600 V RMS
- 50 ... +1832 °F
0,1 ... 1 °F
± (3,0 % + 5,4 °F)
0,1 ... 99,9 %
0,1 %
± (0,2% je kHz + 0,1% + 5 digit)
Duty Cycle (0,5 Hz ...100 kHz, pulsewidth > 2 µs) Continuity test
< 30 Ω
Storage & Operation Temperature
0 ... 40 °C, -20 ... 60 °C by 0 ... 80 % rH
Dimensions & Weight
178 mm x 89 mm x 48 mm, 400 g
Power supply
2 x 1,5 V AA batteries
600 V RMS
600 V RMS
BRIGON Messtechnik GmbH • Kronberger St. 11 • 63110 Rodgau • Germany Tel. + 49 (0) 6106 8207 0 • Fax + 49 (0) 6106 8207 40 • e-mail:
[email protected] • Internet: www.brigon.de Changes also technical changes without prior notice
16042 Rev. 0 / 22.02.2012