Transcript
Digital Audio Wiring / Installation
110 Ω balanced
OmniLIVE - FRNC - AES/ EBU 110 Ω - n x 2 x 0.22 mm²
OL22H..
• 0.22 mm² (AWG24/7) stranded tinned copper conductors • overall Braid Shield • halogen-free and flame retardant acc. to IEC60332-3-24 (cable bundle test)
The compact Audio-multicore OmniLIVE - FRNC for permanent installation cable complies with all national and international safety requirements, including the extremely difficult to reach flame retardance according to IEC 60332-3-24 (cable bundle test). Due to the pair taping with PP foil a very small external diameter could be achieved and still show exceptional electric properties (0.22 mm ² conductor cross section, 47 pF/m capacitance, pair and overall screen, low attenuation, correspondent to the ARD / ZDF specification 3/3, highly suitable for analogue and digital audio signals) .
Das kompakte Audiomulticore OmniLIVE - FRNC für die Festinstallation hält alle nationalen und internationalen Sicherheitsanforderungen ein, so auch die äußerst schwierig zu erreichende Flammwidrigkeitsprüfung gemäß VDE 0482-Teil 266-2-4 / Prüfart C und IEC 60332-3-24 (Kabelbündeltest). Durch den Einsatz einer Paarbewicklung mit PP-Folie konnten trotz überragender elektrischer Eigenschaften (0.22 mm² Leiterquerschnitt, 47 pF/m, Paar- und Gesamtschirm, niedrige Dämpfung, konform zum ARD/ZDF Pflichtenheft 3/3) sehr kleine Außendurchmesser erzielt werden.
Conductor
stranded tinned copper, 7 x 0.20 mm (AWG 24/7)
Leiteraufbau
verzinnte Cu-Litze, 7 x 0,20 mm (AWG 24/7)
Cross Section
0.22 mm²
Leiterquerschnitt
0,22 mm²
Insulation
Foam-Skin PE, KLOTZ multicore colour-code
Isolation
Foam-Skin PE, KLOTZ Multicore Farbcode
Pair Shielding
AL/PETP-foil + tinned stranded drain wire
Paarschirm
AL/PETP-Folie + verzinnte Cu-Beilauflitze
Pair Taping
PP foil
Paarbewicklung
PP-Folie
Overall Shield
tinned copper braid, coverage 85%
Gesamtschirm
verzinnter Cu-Geflechtschirm, Bedeckung > 85%
Overall Jacket
FRNC, grey
Außenmantel
FRNC, grau
Min. Bending Radius
10 x overall diameter
Min. Biegeradius
10 x Außendurchmesser
Working Temperature
-20 °C / +70 °C
Betriebstemperatur
-20 °C / +70 °C
Flame Retardancy
IEC 60332-3-24
Flammwidrigkeit
IEC 60332-3-24
Halogen-Free
IEC 60754-2
Halogenfrei
IEC 60754-2
Conductor Resistance
< 85 Ω/km
Leiterwiderstand
< 85 Ω/km
Kapazität
Capacitance Cond./Cond.
47 pF/m
Ader/Ader
47 pF/m
Characteristic Impedance
110 Ω
Wellenwiderstand
110 Ω
Dämpfung [dB/100m]
Attenuation [dB/100m] 1 MHz
2.6
1 MHz
2,6
3 MHz
4.2
3 MHz
4,2
6 MHz
5.5
6 MHz
5,5
10 MHz
7.1
10 MHz
7,1
Nebensprechdämpfung
Crosstalk Attenuation 15 kHz
> 100 dB
15 kHz
> 100 dB
10 MHz
> 80 dB
10 MHz
> 80 dB
Insulation Resistance
> 1 GΩ x km
Isolationswiderstand
> 1 GΩ x km
Prüfspannung
Test Voltage Cond./Cond.
1200 V
Ader/Ader
1200 V
Cond./Shield
500 V
Ader/Schirm
500 V
grey Order Code Bestell-Nr.
88
Number of Pairs Paarzahl
Outer Ø Außen Ø
Colour Farbe
Weight Gewicht
OL22H08
8
12.2 mm
grey
200 g/m
—
500
OL22H12
12
15.0 mm
grey
275 g/m
—
500
Bulk Cables
Standard Length [m] Standard Längen [m]
Max. Length / Reel Max. Länge / Spule
*lengths other than standard lengths supplied on request *von Standardlängen abweichende Längen auf Anfrage