Preview only show first 10 pages with watermark. For full document please download

• Simultaneous Measurement And Control Of Up To Four Parameters In

   EMBED


Share

Transcript

.book Page 1 Thursday, August 14, 2008 8:19 AM OPTISENS MAC 080 Technical Datasheet • Simultaneous measurement and control of up to four parameters in waste water treatment processess • Supports the full range of OPTISENS 2000 Sensors with automated self cleaning • “Plug and Play” installation, easy calibration, networking capability and highest reliability due to the digital technology .book Page 2 Thursday, August 14, 2008 8:19 AM OPTISENS MAC 080 nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn MAC 080 Multiparameter Converter High End OPTISENS MAC 080 Multiparameter Converter allows a reliable and precise measurement of up to four parameters for waste water and sludge applications. Suitable for the complete range of OPTISENS 2000 Sensors and fitted with the newest digital technology, a large, illuminated graphic display, build-in heater and up to four measuring channels, the OPTISENS MAC 080 is the perfect choice for all measuring applications in industrial and municipal waster water treatment facilities. The rugged design and automated cleaning features of the stainless steel sensors result in the highest reliability for operation in harsh environments. Last but not least, the compact instrument can be easily installed and operated with optimal cost of ownership. Highlights • Support of the complete OPTISENS 2000 Stainless Steel Sensor series with automated cleaning function • Up to four measuring channels • Digital technology for highest reliability and “Plug & play” installation • Rugged design and built-in heater for installations in harsh environments • User-friendly operation with only three membrane keys and large graphic display • Two relays free programmable • Field upgradeable software • Optional Profibus DP Modul Industries • Municipal and industrial waste water treatment facilities • Water monitoring stations Application • Monitoring and control of waste water treatment processes 2 www.krohne.com .book Page 3 Thursday, August 14, 2008 8:19 AM nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn OPTISENS MAC 080 OPTISENS MAC 080 Options/Accessories The MAC 080 in standard configuration is suitable for the connection of up to two sensors. An expansion module for two additional Analog outputs or a Profibus DP module for transmission of up to four measuring channels are available optional. MAC 080 Options: • Expansion module for two additional Analog outputs • Profibus DP module • Solenoid valves for automated spray cleaning of the Sensor (available in 230 V or 117 V) • Y-splitter for the connection of more than one sensor to the flushing valve (Please note! One valve can supply max. 2 sensors) Please note! Only one expansion module can be mounted, either the extra two mA-Module or the Profibus DP module MAC 080 Accessories: • Mounting plate with sunshield for the mounting of Converter, Solenoid valves and junction box • Mounting post, if installation on handrail is not possible • Connection box for connection of up to four OPTISENS 2000 Sensors For more details regarding the options and accessories please refer to the order matrix at the end of this data sheet. www.krohne.com 3 .book Page 4 Thursday, August 14, 2008 8:19 AM OPTISENS MAC 080 nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn OPTISENS 2000 Sensor series: The MAC 080 converter can be used with four different sensors of the OPTISENS 2000 Series measuring Suspended Solids, Dissolved Oxygen, pH and ORP values. All OPTISENS 2000 Sensors are equipped with integrated flush nozzles for automated spray cleaning and enclosed in an extremely robust stainless steel body with streamline design and large outer diameter to minimize ragging. • OPTISENS OAS 2000 Suspended Solids Sensor • OPTISENS OAS 2000 Suspended Solids Sensor (in-line version) • OPTISENS AAS 2000 Dissolved Oxygen Sensor • OPTISENS PAS 2000 pH Sensor • OPTISENS PAS 2000 ORP Sensor The Sensors can either be fitted onto a flexible telescopic rod for immersion into basins or mounted onto a slide rail for installation on side walls. For more information please consult the respective technical data sheets. 4 www.krohne.com .book Page 5 Thursday, August 14, 2008 8:19 AM nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn OPTISENS MAC 080 Single Parameter Measuring System 1 2 3 4 5 6 MAC 080 Converter Solenoid valve for flushing (to be ordered with MAC 080) MAA 2000 Adjustable telescope rod with handrail mounting OAS 2000 Sensor for suspended solids incl. 10 m cable and flush hose Mounting post Mounting plate with sunshield www.krohne.com 5 .book Page 6 Thursday, August 14, 2008 8:19 AM OPTISENS MAC 080 nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn Two Parameter Measuring System 1 2 3 4 5 6 7 8 6 MAC 080 Converter Solenoid valve for flushing (to be ordered with MAC 080) MAA 2000 Adjustable telescope rod with handrail mounting OAS 2000 Sensor for suspended solids incl. 10 m cable and flush hose AAS 2000 DO Sensor incl. 10 m cable and flush hose Junction box for connection of up to 4 sensors (to be ordered with MAC 080) Mounting post Mounting plate with sunshield www.krohne.com .book Page 7 Thursday, August 14, 2008 8:19 AM nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn OPTISENS MAC 080 Four Parameter Measuring System 1 MAC 080 Converter 2 Solenoid valve for flushing (to be ordered with MAC 080) 3 MAA 2000 Adjustable telescope rod with handrail mounting 4 OAS 2000 Sensor for suspended solids incl. 10 m cable and flush hose 5 AAS 2000 DO Sensor incl. 10 m cable and flush hose 6 PAS 2000 ORP Sensor incl. 10 m cable and flush hose 7 AAS 2000 DO Sensor incl. 10 m cable and flush hose 8 Junction box for connection of up to 4 sensors (to be ordered with MAC 080) 9 Mounting post 10 Mounting plate with sunshield www.krohne.com 7 .book Page 8 Thursday, August 14, 2008 8:19 AM OPTISENS MAC 080 nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn Technical Data Measuring System Application Monitoring and control of waste water treatment processes Modular construction A typical measuring system consists of: OPTISENS 080 Converter incl. solenoid valves, junction box and expansion modules (if necessary) OPTISENS 2000 Sensors including cable and flush hose (up to four) OPTISENS MAA 2000 Mounting assemblies Optional: Mounting plate and mounting post Converter Design Plastic enclosure (IP65) for wall mounting Cable feedthrough M20, IP68 rated (½” NPT adapter available optional) Display Graphic display Graphic display, 70x40 mm (illuminated) Keypad Three button membrane key pad Languages English, German, Swedish Installation conditions Ambient temperature -20...+50°C / -4…+122°F Storage temperature 0…+60°C / +32…+140°F Installation Wall or handrail mountable (using optional available mounting plate) Materials Enclosure Polycarbonate enclosure Cable feedthrough Nickel plated brass, inserts polyamid Electrical connections Power supply 85…250 VAC – 50/60 Hz Power consumption 20 Watts (0.180 A @ 110V) Fuse 3.15 A Slow 250 V 4 x 20 mm Input Output Sensor inputs (up to four) Digital communication RS485 One direct sensor input via M12 Plug 2...4 via external junction box (option); Standard cable length 10 m (max. up to 100 m) Digital inputs 3 digital inputs (for selection of different calibration curves) Analog outputs Two 4…20 mA outputs, (extendable to four via expansion module), galvanic isolated, 450 Ohm Relay outputs 2 relays: Dry contacts, normally open, 250 V AC, max. 12 A 8 www.krohne.com .book Page 9 Thursday, August 14, 2008 8:19 AM nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn OPTISENS MAC 080 Serial interface RS232 "log line" to PC (mainly used for service); 19200 baud, 8 bits, 1 stop bit, no parity, no flow control; using simple ASCII protocol described in the manual; Field bus (optional) Profibus DP-V0 (slave) module Approvals Protection class IP68 (Nema 6) Approval mark CE Electromagnetic compatibility (89/336/EEC) Electromagnetic compatibility (EMC) in accordance with: EN 61000-6-4:2001: Emission standard for industrial environments; EN 61000-6-2:2001: Immunity for industrial environments Low Voltage Directive (89/336/EEC) Safety requirements for electrical equipment for measurement, control, and laboratory use in accordance with EN 61010-1:2001 Module for two addtl. outputs (option) 1 Functions To extend the MAC 080 Analog Outputs to a total of 4 Design PCB only, will be installed inside the MAC 080 box Ambient temp -20...+50°C / -4...+122°F if installed in a operational MAC 080 Storage temp 0…+60°C / +32…+140°F Dimensions 86 x 54 mm / 3.39" x 2.13" Weight 35 g / 1.23 oz Output signals Two 4...20 mA (20...4 mA), galvanic isolated, 450 Ω Profibus DP module (option) 1 Functions For connection of MAC 080 to a Profibus network as a slave and to enable connection of four OPTISENS 2000 sensors Fieldbus type DP-V0 slave communication according to EN 50170 (DIN 19245, IEC 61158), Protocol version 1.10 Design PCB only, will be installed inside the MAC 080 box Ambient temperature -20...+50°C / -4...+122°F if installed in a operational MAC 080 Storage temperature 0...+70°C / +32...+158°F Dimensions 86 x 54 mm / 3.39" x 2.13" Power +5 V max. 350 mA Output RS485 optically isolated Profibus interface with DC/DC converter on board; Automatic baud rate detection (96000 bit/s...12 Mbit/s) 1 Only one optional module can be installed. Either the two additional outputs module OR the Profibus DP module www.krohne.com 9 .book Page 10 Thursday, August 14, 2008 8:19 AM OPTISENS MAC 080 nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn Dimensions & Weights b a c d k i h g f Dimensions [mm] e Dimensions [inch] a 78 3.07 b 40 1.57 c 180 7.09 d 164 6.46 e M20 cable feedthrough (NPT adapter optional) f 29 1.14 g 4.3 Ø0.17 h 239 9.41 i 255 10.04 k 279 10.98 1.3 kg 2.8 lbs Weight 10 www.krohne.com .book Page 11 Thursday, August 14, 2008 8:19 AM nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn OPTISENS MAC 080 Order code Accessories VGA Z C 08000 Mounting post, 1700mm height, incl. horizontal bar VGA Z C 08010 Mounting plate with sunshield for OPTISENS converter www.krohne.com 11 .book Page 12 Thursday, August 14, 2008 8:19 AM OPTISENS MAC 080 nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn KROHNE measuring technology - Product overview • • • • • • Electromagnetic flowmeters Variable area flowmeters Mass flowmeters Ultrasonic flowmeters Vortex flowmeters • • • • • Level measuring instruments Temperature measuring instruments Pressure measuring instruments Analysis Oil and gas industry Flow controllers Addresses: Germany KROHNE sales companies Northern sales office KROHNE Messtechnik GmbH & Co. KG Bremer Str. 133 D-21073 Hamburg Phone:+49 (0)40 767 3340 Fax:+49 (0)40 767 33412 [email protected] ZIP code: 10000 - 29999, 49000 - 49999 Western and middle sales office KROHNE Messtechnik GmbH & Co. KG Ludwig-Krohne-Straße D-47058 Duisburg Phone:+49 (0)203 301 4416 Fax:+49 (0)203 301 10416 [email protected] ZIP code: 30000 - 34999, 37000 48000, 50000 - 53999, 57000 - 59999, 98000 - 99999 Southern sales office KROHNE Messtechnik GmbH & Co. KG Landsberger Str. 392 D-81241 Munich Phone:+49 (0)89 121 5620 Fax:+49 (0)89 129 6190 [email protected] ZIP code: 0 - 9999, 80000 - 89999, 90000 - 97999 KROHNE Messtechnik GmbH & Co. KG Rüdesheimer Str. 40 D-65239 Hochheim/Main Phone: +49(0)6146) 827 30 Fax:+49 (0)6146 827 312 [email protected] ZIP code: 35000 - 36999, 54000 56999, 60000 - 79999 Instrumentation and control equipment catalog TABLAR Messtechnik GmbH Ludwig-Krohne-Str. 5 D-47058 Duisburg Phone:+49 (0)2 03 305 880 Fax:+49 (0)2 03 305 8888 [email protected]; www.tablar.de TD MAC 080 R01 en Subject to change without notice Southwestern sales office International Australia KROHNE Australia Pty Ltd Quantum Business Park 10/287 Victoria Rd Rydalmere NSW 2116 Phone: +61 2 8846 1700 Fax: +61 2 8846 1755 [email protected] Austria KROHNE Gesellschaft m.b.H. Modecenterstraße 14 A-1030 Vienna Phone:+43 (0)1/203 45 32 Fax:+43 (0)1/203 45 32 99 [email protected] Belgium KROHNE Belgium N.V. Brusselstraat 320 B-1702 Groot Bijgaarden Phone:+32 (0)2 4 66 00 10 Fax:+32 (0)2 4 66 08 00 [email protected] Brazil KROHNE Conaut Controles Automaticos Ltda. Estrada Das Águas Espraiadas, 230 C.P. 56 06835 - 080 EMBU - SP Phone:+55 (0)11-4785-2700 Fax:+55 (0)11 4785-2768 [email protected] China KROHNE Measurement Instruments (Shanghai) Co. Ltd., (KMIC) 9th Floor, Puyuan Science Park, Building A 396 Guilin Road Shanghai 200233 Tel.: +86 (021) 6470 5656 Fax: +86 (021) 6451 6408 [email protected] Czech Republic Krohne CZ, spol. s r.o. Sobìsická 156 63800 Brno Phone: +420 (0)545.242 627 Fax: +420 (0)545 220 093 [email protected] © KROHNE 08/2008 France KROHNE S.A.S. Les Ors BP 98 F-26103 ROMANS Cedex Phone:+33 (0)4 75 05 44 00 Fax:+33 (0)4 75 05 00 48 [email protected] www.krohne.com Great Britain KROHNE Ltd. Rutherford Drive Park Farm Industrial Estate Wellingborough Northants NN8 6AE Phone:+44 (0)19 33 408 500 Fax:+44 (0)19 33 408 501 [email protected] CIS Kanex KROHNE Engineering AG Business Centre "POLLARS", office 164 Derbenevskaya nab., 11-B 113114 Moscow/Russia Tel. / Fax: +7 (0)495 913-68-41 Tel. / Fax: +7 (0)495 913-68-42 Tel. / Fax: +7 (0)495 913-68-43 Tel. / Fax: +7 (0)495 913-68-44 [email protected] India Krohne Marshall Ltd. A-34/35, M.I.D.C. Industrial Area, H-Block Pimpri Poona 411018 Phone:+91 (0)202 744 2020 Fax:+91 (0)202 744 2020 [email protected] Iran KROHNE Liaison Office North Sohrevardi Ave. 26, Sarmad St., Apt. #9 Tehran 15539 Phone: +9821 8874 5973 Fax: +9821 8850 1268 [email protected] Italy KROHNE Italia Srl. Via V. Monti 75 I-20145 Milan Phone:+39 02 4300 661 Fax:+39 02 4300 6666 [email protected] Korea KROHNE Korea Room 508 Miwon Bldg 43 Yoido-Dong Youngdeungpo-Ku Seoul, Korea Phone: 00-82-2-782-1900 Fax: 00-82-2-780-1749 [email protected] Netherlands KROHNE Nederland B.V. Kerkeplaat 14 NL-3313 LC Dordrecht Phone:+31 (0)78 630 6200 Fax:+31 (0)78 630 6405 Service Direct: +31 (0)78 630 6222 [email protected] Norway KROHNE Norway A.S. Ekholtveien 114 NO-1521 Moss Phone:+47 (0)69 264 860 Fax:+47 (0)69 267 333 [email protected] Poland KROHNE Polska Sp.z.o.o. ul. Stary Rynek Oliwski 8a 80-324 Gdansk Phone: +48 (0)58 520 9211 Fax.:+48 (0)58 520 9212 [email protected] Switzerland KROHNE AG Uferstr. 90 CH-4019 Basel Phone:+41 (0)61 638 30 30 Fax:+41 (0)61 638 30 40 [email protected] Singapore Tokyo Keiso - KROHNE (Singapore) Pte. Ltd. 14, International Business Park, Jurong East Chiyoda Building, #01-01/02 Singapore 609922 Phone: (65) 6567 4548 Fax : (65) 6567 9874 [email protected] Republic of South Africa KROHNE Pty. Ltd. Bushbock Close Corporate Park South Midrand, Gauteng P.O. Box 2069 Midrand, 1685 Tel.: +27 (0)11 314 1391 Fax: +27 (0)11 314 1681 [email protected] Spain I.I. KROHNE IBERIA, S.r.l. Poligono Industrial Nilo Calle Brasil, nº. 5 28806 Alcalá de Henares Madrid Phone: +34 (0)91 883 2152 Fax: +34 (0)91 883 4854 [email protected] USA KROHNE, Inc. 7 Dearborn Road Peabody, MA 01960 Phone: +1 (800) FLOWING Phone: +1 (978) 535 6060 (in MA) [email protected] Representatives Algeria Argentina Cameroon Canada Chile Columbia Croatia Denmark Ecuador Egypt Finland Gabon Ghana Greece Hong Kong Hungary Indonesia Iran Ireland Israel Ivory Coast Japan Jordan Kuwait Libya Lithuania Malaysia Mauritius Mexico Morocco New Zealand Peru Portugal Romania Saudi Arabia Senegal Slovakia Slovenia Sweden Taiwan Thailand Tunisia Turkey Venezuela Yugoslavia Other countries KROHNE Messtechnik GmbH & Co. KG Ludwig-Krohne-Str. 5 D-47058 Duisburg Phone:+49 (0)203 301 0 Fax:+49 (0)203 301 389 [email protected]