Transcript
Bulletin 700-FS
Electronic High Performance Timing Relays
Bulletin 700-FS Timing Relays • Multi-Function 10 functions selectable 10 time settings selectable • Single-Functions 11 single-functions selectable 12 time settings available • Special Functions 3 single-functions selectable 12 time settings available
Bulletin 700-FS Timing Relays • Multi-Function 10 functions selectable 10 time settings available • Single-Functions 2 single-functions selectable 10 time settings available
Table of Contents Description
Page
Description
Page
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-11
Type Designation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-6
Specifications
Product Selection Multi-Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-7
Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-12 Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-13
Single-Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-8
Approvals and Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-13
Unequal Repeat Cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-10
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-14
Reset Delay without Supply Voltage . . . . . . . . . . . . . . . . . . . . 8-10 Star-delta Timing Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-11
Rockwell Automation
8-5
8
Bulletin 700-FS
Electronic High Performance Timing Relays Type Designation Multi-Function
700-FS
M Function M Multi-function timing relays 8 single-functions ON and OFF function additional (for commissioning and inspection)
3
U
U23
Assem. of Contacts
Time Range
3 1 Changeover U 0.05 s … 60 h contact 1 C/O 4 2 Changeover contacts 2 C/O (output 2 programmable as instantaneous contact)
Supply Voltage Z12 U23 U18 A40
12 VDC 24 … 48 VDC 24 … 240 V 50/60 Hz 24 … 240 VUC 400 V 50/60 Hz
Single-Functions
700-FS
A Functions A On-delay B Off-delay
700-FS
Functions
8
On-delay Reset delay Pick-up and reset delay One-shot Fleeting off-delay Flashing started by impulse Flashing started by pause Pulse generator On-delay with impulse control One-shot / Watch dog Pulse converter
U
Assem. of Contacts 3 1 Changeover contact 1 C/O 4 2 Changeover contacts 2 C/O
A A B C D E F G I J K L
3
Time Range U 0.05 s … 60 h
Supply Voltage Z12 U23 A40
3
A
Assem. of Contacts 3 1 Changeover contact 1 C/O
U23
0.05 0.15 0.5 1.5 0.05 0.15 0.5 1.5 0.05 0.15 0.5 3
… … … … … … … … … … … …
VDC VDC V 50/60 Hz V 50/60 Hz
U23
Time Range A B C D E F G H I J K L
12 24 … 48 24 … 240 400
1 3 10 30 1 3 10 30 1 3 10 60
s s s s min min min min h h h h
Supply Voltage Z12 U23 U18 A40
12 VDC 24 … 48 VDC 24 … 240 V 50/60 Hz 24 … 240 VUC 400 V 50/60 Hz
Special-Functions
700-FS
H Functions H Unequal repeat cycle
3
U
U23
Assem. of Contacts
Time Range
3 1 Changeover contact 1 C/O
U 0.05 s … 60 h V 2 x 0.05 s… 60 h
Supply Voltage Z12 U23 A40
700-FS
Q Functions Q Off-delay without Supply Voltages
700-FS
Y Functions Y Star-Delta Timing Relays
8-6
3
Q
Assem. of Contacts
Time Range Q 0.15 s … 10 min
2
C
Assem. of Contacts
Supply Voltage U18
0.5 1.5 0.05 0.15 0.5
… … … … …
24 … 240 VUC
U23
Time Ranges C D E F G
VDC VDC V 50/60 Hz V 50/60 Hz
U18
3 1 Changeover contact 1 C/O 4 2 Changeover contacts 2 C/O
2 2 normally open contacts 2 N.O.
12 24 … 48 24 … 240 400
10 30 1 3 10
s s min min min
Supply Voltages U23 A40
24 … 48 VDC 24 … 240 V 50/60 Hz 400 V 50/60 Hz
Rockwell Automation
Bulletin 700-FS
Electronic High Performance Timing Relays Product Selection Multi-Function Overall-width 22.5 mm according to DIN 43880 Description Multi-function timing relays 700-FSM includes 10 setting functions: Multi-Time Setting Range 0.05 s…60 h (A) - On-delay (1s) 0.05…1 s (B) - Off-delay (3s) 0.15…3 s (C) - On- and off-delay (10s) 0.5…10 s (D) - One-shot (1mn) 0.05…1 min (E) - Fleeting off-delay (3mn) 0.15…3 min (F) - Flashing started by impulse (10mn) 0.5…10 min (I) - Pulse generator (1h) 0.05…1 h (L) - Pulse converter (3h) 0.15…3 h (On) - ON-Function * (10h) 0.5…10 h (Off) - OFF-Function * (60h) 3…60 h * (for commissioning and inspection) Cat. No. PQ Cat. No. Supply Voltages (A1/A2) U23 24…48 VDC; 24…240 V, 50/60 Hz 700-FSM3UU23 700-FSM4UU23 Z12 12 VDC 700-FSM3UZ12 700-FSM4UZ12 1 700-FSM3UU18 700-FSM4UU18 U18 24…240 VUC A40 400 V, 50/60 Hz 700-FSM3UA40 700-FSM4UA40 (B) Off-delay
Availability from stock on request on request on request (A) On-delay
A1/A2 15 18 16 25 28 26 21 24 ➋ 22
U Output 1 Output 2
t t
Output 2 LED
L/+
15
A1
21 25
A1/A2
U S
N/-
A2
18 16 28 26 24 22 ➌ ➋
Z1 Z2
Output 1
t
Output 2
t
A1/B1 15 18 16 25 28 26 21 24 ➋ 22
Output 2
➊
L/+
A1 B1 S
N/-
A2
15
Z1 Z2 ➌
LED
(C) On- and Off-delay
A1 B1 S
A1/B1
Output 1
t
t
Output 2
t
15 18 16
t
25 28 26 21 24 ➋ 22
Output 2
N/-
A2
15
21 25
S
t
Output 2
t
Output 2
A1/B1 15 18 16 25 28 26 21 24 ➋ 22
➊
L/+
A1 B1 S
N/-
A2
LED
15
Output 1 Output 2
t
0.5s 0.5s
Output 2
15 18 16 28 25 26 21 24 ➋ 22
LED
15
A1
Output 1 Output 2
21 25
8 N/-
A2
18 16 28 26 24 22 ➌ ➋
Z1 Z2
A1/A2
Output 1
t
Output 2
t
t
t
t
t
t t
t
25 28 26 21 24 ➋ 22
Output 2
18 16 28 26 24 22 ➌ ➋
Z1 Z2
t
15 18 16
L/+
15
A1
N/-
A2
Z1 Z2 ➌
LED
L/+
15
A1
N/-
A2
21 25
A1/A2
U S
21 25
18 16 28 26 24 22 ➋
18 16 28 26 24 22 ➌ ➋
Z1 Z2
Output 1
t
18 15 16
Output 2
t
28 25 26
Output 2
➊
L/+ A1/B1
21 24 ➋ 22
A1 B1 S
N/-
A2
(Off) OFF-Function A1/A2 18 15 16 25 28 26
LED
U
A1/A2
Output 1
18 15 16
Output 2
25 28 26
15
21 25
18 16 28 26 24 22 ➌ ➋
Z1 Z2
LED
(On) ON-Function U
18 16 28 26 24 22 ➋
(L) Pulse converter A1/A2
t
t
U
21 25
(I) Pulse generator U
21 25
(F) Flashing started by impulse A1/A2
Output 1
t
Output 2
L/+
LED
(E) Fleeting off-delay U
Output 1
18 15 16 28 25 26 24 21 ➋ 22
Output 2
18 16 28 26 24 22 ➌ ➋
Z1 Z2
LED
A1/B1
U
➊
L/+
S
1
(D) One-shot A1/A2
U
PQ
Unmistakably Function Display by LED Output in rest position, no timing
LED
Output in rest position, time running Output in operating position, no timing Output in operating position, time running
➊ A voltage other than the supply voltage can be used for the impulse control. ➋ Output 2, selectable as instantaneous contact with sliding switch on front panel ➌ Bridge or potentiometer 10 kΩ, min. 0.25 W (low voltage) for external setting. PQ = Package Quantity Accessories - Page 8-11 Specifications - Page 8-12 Dimensions - Page 8-14
Rockwell Automation
8-7
Bulletin 700-FS
Electronic High Performance Timing Relays Product Selection Single-Function Overall-width 22.5 mm according to DIN 43880 Description ✪ Available Mono-Time Ranges Complete the Cat. No. with the corresponding identification ✪ from the table on the next page (bottom).
Z12 U23 U18 A40
Supply Voltages (A1/A2) 12 VDC 24 … 48 VDC 24 … 240 V, 50/60 Hz 24 … 240 VUC 400 V, 50/60 Hz
Additionally for Functions A and B: U Available Mono-Time Ranges 0.05 s…60 h (1s) 0.05…1 s (1mn) 0.05…1 min (3s) 0.15…3 s (3mn) 0.15…3 min (10s) 0.5…10 s (10mn) 0.5…10 min
Function Diagrams / Connection Diagrams
Cat. No.
PQ
from stock: 700-FSA3✪U23 700-FSA3UU23 on request: 700-FSA3✪Z12 700-FSA3UZ12 700-FSA3✪U18 700-FSA3✪A40 700-FSA3UA40
1
from stock: 700-FSB3✪U23 700-FSB3UU23 on request: 700-FSB3✪Z12 700-FSB3UZ12 700-FSB3✪U18 700-FSB3✪A40 700-FSB3UA40
1
(1h) 0.05…1 h (3h) 0.15…3 h (10h) 0.5…10 h (60h) 3…60 h
Cat. No.
PQ
from stock: 700-FSA4UU23 on request: 700-FSA4UZ12 700-FSA4UA40
1
from stock: 700-FSB4UU23 on request: 700-FSB4UZ12 700-FSB4UA40
1
(A) On-delay The output contact changes state after the time delay is completed. A1/A2 15 18 16
U Output
t
LED A1/A2 15 18 16 25 28 26 21 24 ➋ 22
U Output 1 Output 2
t t
Output 2 LED
8
L/+
A1
15
N/-
A2
18 16
L/+
A2
N/-
21 25
15
A1
18 16 28 26 24 22 ➌ ➋
Z1 Z2
(B) Off-delay The output contact changes state when switch „S“ is closed. When switch „S“ is opened, the time delay begins. After the time delay is completed, the contact returns to shelf state. A1/A2
U
➊
L/+
A1 B1 S
S Output
15
A1/B1 15 18 16
t
LED
N/A1/A2
U S Output 1
t
Output 2
t
A1/B1 15 18 16 25 28 26 21 24 ➋ 22
Output 2
A2
18 16 ➊
L/+
A1 B1 S
A2
N/-
15
21 25
18 16 28 26 24 22 ➌ ➋
Z1 Z2
LED
(C) On- and Off-delay The output contact changes state after the time delay is completed. After the time delay is completed, the contact returns to shelf state. A1/A2
U
➊
L/+
A1 B1 S
S
15
A1/B1
t
Output
t
15 18 16
LED
N/-
A2
from stock: 700-FSC3✪U23 on request: 700-FSC3✪Z12 700-FSC3✪U18 700-FSC3✪A40
1
—
from stock: 700-FSD3✪U23 on request: 700-FSD3✪Z12 700-FSD3✪U18 700-FSD3✪A40
1
—
18 16
1
(D) One-shot The output contact changes state when the relay is energised. The output contact returns to shelf state when the time delay is completed. L/+ A1/B1
U Output
t
A1
15
A2
18 16
15 18 16
LED
N/-
➊ A voltage other than the supply voltage can be used for the impulse control ➋ Output 2, selectable as instantaneous contact with sliding switch on front panel ➌ Bridge or potentiometer 10 kΩ, min. 0.25 W (low voltage) for external setting PQ = Package Quantity Accessories - Page 8-11 Specifications - Page 8-12 Dimensions - Page 8-14
8-8
Rockwell Automation
Bulletin 700-FS
Electronic High Performance Timing Relays Product Selection Description Function Diagrams/ Connection Diagrams (E) Fleeting off-delay The output contact changes state after closing and opening switch „S“. After the time delay is completed, the contact returns to shelf state. A1/A2
U
Output
A1/B1 15 18 16
t
LED
N/-
A2
15
18 16
(F) Flashing Started by Impulse The output contact changes state when power is applied. At the end of the time delay, the output contact returns to shelf state. This cycle continues until the power is removed. U Output 1
t
t
t
t
A1/A2 15 18 16 t
LED
L/+
N/-
A1
15
A2
18 16
A1/A2
U Output 1
t
t
t
t
A1
15
A2
18 16
18 t 15 16
LED
N/-
(I) On-delay Pulse Generator The output contact changes state when the time delay is completed. After 0.5 s the contact opens. L/+
A1/A2
U
t
Output
A1
15 18 16 A2
N/-
18 16
(J) On-delay (Pulse Controlled) When switch „S“ is closed, the output contact changes state. A1/A2
U
A1 B1 S
S Ausgang
15
A1/B1 15 18 16
t
LED
N/-
A2
18 16
(K) One-Shot / Watch Dog When switch „S is closed, the output contact changes state. A1/A2 U
A1 B1 S
S Output
15
A1/B1 15 18 16
t
LED
N/-
A2
18 16
(L) Pulse converter When switch „S is closed, the output contact changes state. The time „t“ is not influenced by the duration of the control pulse. A1/A2 U
A1 B1 S
S Output
➊
L/+
15
A1/B1
t
15 18 16
LED
N/-
A2
1
1
8
1
from stock: 700-FSK3✪U23 on request: 700-FSK3✪Z12 700-FSK3✪U18 700-FSK3✪A40
➊
L/+
from stock: 700-FSG3✪U23 on request: 700-FSG3✪Z12 700-FSG3✪U18 700-FSG3✪A40
from stock: 700-FSJ3✪U23 on request: 700-FSJ3✪Z12 700-FSJ3✪U18 700-FSJ3✪A40
➊
L/+
1
from stock: 700-FSI3✪U23 on request: 700-FSI3✪Z12 700-FSI3✪U18 700-FSI3✪A40
15
0.5s
LED
1
from stock: 700-FSF3✪U23 on request: 700-FSF3✪Z12 700-FSF3✪U18 700-FSF3✪A40
(G) Flashing Started by Pause The output contact remains in the shelf state until the time delay is completed. When the time delay is completed, the contact changes state. This cycle continues until the power is removed. L/+
PQ
from stock: 700-FSE3✪U23 on request: 700-FSE3✪Z12 700-FSE3✪U18 700-FSE3✪A40
➊
L/+
A1 B1 S
S
Cat. No.
18 16
1
from stock: 700-FSL3✪U23 on request: 700-FSL3✪Z12 700-FSL3✪U18 700-FSL3✪A40
1
➊ A voltage other than the supply voltage can be used for the impulse control
✪ Mono-Time Ranges Complete the Cat. No. with mono-time range identification Time Ranges ✪
0.05…1 s A
0.15…3 s B
0.5…10 s C
1.5…30 s D
0.05…1 min E
0.15…3 min F
Time Ranges ✪
0.5…10 min G
1.5…30 min H
0.05…1 h I
0.15…3 h J
0.5…10 h K
3.0…60 h L
PQ = Package Quantity Accessories - Page 8-11 Specifications - Page 8-12 Dimensions - Page 8-14
Rockwell Automation
8-9
Bulletin 700-FS
Electronic High Performance Timing Relays Product Selection Special Functions Overall-width 22.5 mm according to DIN 43880 Description Multi-Time Setting Ranges
Supply Voltages (A1/A2) 12 VDC 24 … 48 VDC 24 … 240 V, 50/60 Hz A40 400 V, 50/60 Hz Function Diagrams/ Connection Diagrams (H) Flasher (Repeat Cycle Starting with Pulse or Pause) The repeat cycle timer permits different setting for on and off times. The following operating modes are possible depending on device and drive: - Output starts with pulse or pause - Controlled by supply voltages or additional control contact. - Period runoff or continuous cycles (when operated with control contact). - Joint selection of time ranges with 700-FSH3U or individual selection of time range with 700-FSH3V for pulse and pause time. Supply Voltage Controlled, Oscillating Mode Starting with Pause Z12 U23
A1/A2
U S Output
t2
t1
S A1
N/-
A2
LED
B1 15
18 16
Supply Voltage Controlled, Oscillating Mode Starting with Pulse A1/A2
U S
8
S A1
L/+
B1 15
A1/B1 t1
t1
t2
Output
t2
15 18 16
18 16
A2
N/-
LED
Pulse controlled, Oscillating Mode Starting with Pulse and Pause A1/A2 U S
from stock: 700-FSH3UU23 700-FSH3VU23 on request: 700-FSH3UZ12 700-FSH3VZ12 700-FSH3UA40 700-FSH3VA40
1
➊
L/+
A1 B1 S
15
A1/B1 t2
Output
0.5…10 min 0.05…1 h 0.15…3 h 0.5…10 h 3… 60 h
A1/B1 15 18 16
t2
t1
L/+
U 0.05 s…60 h V 2 x 0.05 s…60 h (1s) 0.05… 1 s (10mn) (3s) 0.15… 3 s (1h) (10s) 0.5… 10 s (3h) (1mn) 0.05…1 min (10h) (3mn) 0.15…3 min (60h) Cat. No. PQ
t1
t2 t1
15 18 16
LED
N/-
A2
18 16
Pulse controlled, Oscillating Mode Starting with Pulse ➊
L/+
A1/A2 U S
A1 B1 S
15
A1/B1 t1
t2
Output
t1
t2
15 18 16
LED
N/-
A2
18 16
➊ A voltage other than the supply voltage can be used for the impulse control Multi-Time Setting Ranges Q 0.15 s…10 min Supply Voltages (A1/A2) U18 24 … 240 VUC Function Diagrams/ Connection Diagrams (Q) Off-delay without Supply Voltages When input power is turned on, the output contact changes state. When the power is removed, the time delay begins. The output contact returns to shelf state at the end of the time delay. L/+ U Output
t
N/-
U
Output 2
15
from stock: 700-FSQ3QU18
A1/A2 15 18 16
LED
Output 1
A1
A1/A2
t
15 18 16
t
25 28 26
LED
L/+
N/-
A2
18 16
A1
15
A2
(2.5s) 0.15 … 2.5 s (10s) 0.5 … 10 s Cat. No. PQ
25
(80s) 4 … 80s (10mn) 0.5 … 10min Cat. No. PQ
1
from stock: 700-FSQ4QU18
1
18 16 28 26
Accessories - Page 8-11 Specifications - Page 8-12 Dimensions - Page 8-14
8-10
Rockwell Automation
Bulletin 700-FS
Electronic High Performance Timing Relays Product Selection/ Accessories Special Functions Overall-width 22.5 mm according to DIN 43880 Description
✪ Available Mono-Time Ranges Complete the Cat. No. with the corresponding identification ✪ from Supply Voltages (A1/A2) the table below. U23 24 … 48 VDC 24 …240 V, 50/60 Hz A40 400 V, 50/60 Hz Function Diagrams / Connection Diagrams
Cat. No.
PQ
from stock: 700-FSY2✪U23 on request: 700-FSY2✪A40
1
(Y) Star-Delta Timing Relay When power is applied, the output contact (Y) changes state. After the fixed time tu, the output contact ∆ changes state. Both output contacts return to shelf state whenever the power is removed. A1/A2
U
t
L
A1
N
A2
17
17/18 17/28
tu = 50...65 ms LED
18 Y
28 ∆
✪ Mono-Time Ranges Complete the Cat. No. with mono-time identification. Time Ranges
0.5…10 s
1.5…30 s
0.05…1 min
0.15…3 min
0.5…10 min
✪
C
D
E
F
G
8 Accessories Cat. No.
PQ
Setting Knob with Scale Raised setting knob for time setting without tools
700-FSK
10
Screw Adapter For surface mounting according to drilling plan EN 50 002
199-FSA
5
Description
Labelling Material •
Uniform labelling material for contactors, motor protection devices, timing relays and circuit breakers. For product information and ordering informations see chapter 3.
PQ = Package Quantity
Dimensions - Page 8-14
Rockwell Automation
8-11
Bulletin 700-FS
Electronic High Performance Timing Relays Specifications Specifications Time characteristics (according to VDE 0435, Part 2021) ± 5% of the rime range end value (tmax.)
Setting accuracy
± 0.2% of the setting value voltage: ± 0.001%/%∆U temperature: ± 0.025%/°C
Repeatability Tolerances
Supply Supply Voltages Voltage Tolerance AC DC Power Consumption at 240 VAC [VA] at 24 VDC [W] Time Energised Reset Value [ms] Voltage Isolation Cable Length of Supply Voltage Control [m]
24…48 VDC and 24…240 VAC, 50/60 Hz (dual voltage) -15%/+10% -20%/+20% 5 0.5 100% 50 <20 ms without reset (supply voltage) max. 250
Pulse Control (B1) Pulse Duration AC [ms] DC [ms] Input Voltage Input Current [mA] Cable Length without parallel load between B1 and A2 [m] with load (<3 kΩ) between B1 and A2 [m]
8
>50 >30 same as supply voltage range 1 max. 250 max. 50
Outputs Contact Type Switching Capacity
Relays as changeover switch Voltage: 440 VAC Current Ith: 8 A Power: 2000 VA according to IEC 947-5-1: 3 A/440 VAC (inductive load, AC 14) 3 A/250 VAC (inductive load, AC 15) 1 A/24 VDC (inductive load, DC 13) according to UL 508: 1.5 A/250 VAC (B300) 3 A/120 VAC (B300) 10 A gL
Short-circuit Resistance Lifespan mechanical
[operations]
30 Mio.
electrical
[operations]
4 Mio. at 1 A/250 VAC, cos ϕ = 1 0.2 Mio. at 6 A/250 VAC, cos ϕ = 1 1.5 Mio. at 1 A/250 VAC, cos ϕ = 0.3 0.3 Mio. at 3 A/250 VAC, cos ϕ = 0.3 0.5 Mio. at 6 A/24 VDC, resistive 2 Mio. at4 A/24 VDC, resistive 2 Mio. at 0.2 A/230 VDC, resistive 1 Mio. at 0.4 A/24 VDC, L/R = 20 ms 1 Mio. at 0.2 A/110 VDC, L/R = 20 ms 1 Mio. at 0.1 A/230 VDC, L/R = 20 ms 1 LED, combination signal
State Indication
Product Selection - Page 8-7
8-12
Rockwell Automation
Bulletin 700-FS
Electronic High Performance Timing Relays Specifications
General Data Insulation Characteristics
2 kVAC/50 Hz test voltage according to VDE 0435 and 6 kV 1.2/50 µs surge voltage according to IEC 947-1 between all inputs and outputs Performance of following requirements: according to IEC 1000-4-5: 4 kV 1.2/50 µs according to IEC 1000-4-4: 6 kV 6/50 ns according to IEC 1000-4-2: contact 8 kV, air 8 kV according to IEC 801-3: level 3 according to IEC 801-6: level 3 electromagnetical field according to EN 55 022: class B according to VDE 106, part 101 56 cycles (24 h) at 25…40°C and 95% rel. humidity according to IEC 68-2-30 and IEC 68-2-3 4 G in 3 axis at 10…500 Hz, test FC according to IEC 68-2-6 50 G according to IEC 68-2-27
EMC Interference Immunity Surge Capacity of Supply Voltage Burst ESD Discharge Electromagnetic HF field Conducted electromagnetic HF field signal EMC Emmission Safe Isolation Climatic Withstand Vibration Resistance Shock Resistance Protection Class Enclosure Terminals Weight Approvals Ambient Temperature Open Enclosed Storage Terminals
[g]
[°C] [°C] [°C]
IP 40, IP 30 (single-function) IP 20 according to IEC 947-1 100 CE, UL Listed, C-UL Listed, Germanischer Lloyd -25 … +60 -25 … +45 -40 … +85 Screw terminal M3.5 for pozidrive No.2, Philips and slotted screws No. 2. Suitable for power screw driver. Rated tightening torque 0.8 Nm (max. 1.2 Nm) Dual-chamber system for terminal cross-sections of 1 x 0.5 mm2 … 2 x 2.5 mm2
Mounting
8
(solid) or 2 x 2.5 mm2 (stranded, flexible with sleeve), AWG 20…14. Finger protection according to VDE 0106 Front mounting; For snap-on mounting on DIN rail 35 mm or screw fixing by adapter and 2 screws M4
Product Selection - Page 8-7
Rockwell Automation
8-13
Bulletin 700-FS
Electronic High Performance Timing Relays Dimensions Dimensions are shown in millimeters 96
96
7
35
78.8
22.5
7
35
78.8
22.5
101
101
109
109
700-FS (1 C/O)
22.5
700-FS (2 C/O)
22.5
13
75
58
35
7
8
12
17
35
78.8
4.3
96
109
700-FSH3V…
2
4.3
101
5.5
9
199-FSA
Product Selection - Page 8-7
8-14
Rockwell Automation
Bulletin 700-FE
Economy Timing Relays
Bulletin 700-FE Timing Relay • Multi-Function 4 functions selectable 4 time settings selectable • Single-Functions 4 single-functions selectable 4 time settings selectable
Bulletin 700-FE Timing Relay • Multi-Function 4 functions selectable 6 time settings selectable • Single-Functions 6 single-functions selectable 6 time settings selectable • Special Function 1 single-function 4 time settings selectable
Table of Contents Description
Page
Description
Page
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-19
Type Designation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-16
Specifications
Product Selection Multi-function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-17
Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-20 Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-21
Single-functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-18
Standards and Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-21
Star-Delta-Timing Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-19
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-22
Rockwell Automation
8-15
8