Transcript
SUPPLY AIR THERMISTOR
MOTOR POWER PLUG RED 1
RED
BLOWER MOTOR
WHITE 2
WHITE BLACK 3
BLACK MOTOR CONTROLLER
RED
SECONDARY LIMIT
1
RED
YELLOW
YELLOW 2
53 WHITE
4
ORANGE BROWN 5
BROWN
77
60
4
78
79
RED/BLACK
9 58
2
6
10
3
7
11
4
8
12
13
16
83
18
87
14
RED
BLUE
11
107
F
1
Y
NO NC
COM
BLUE
BROWN
111
LOW AMBIENT CONTROL
61 61
PURPLE
R
RED
Y2
D
A
LOW VOLTAGE TERMINAL STRIP
BLUE High Speed Solenoid
1
COMPRESSOR CRANK CASE HEATER (OPT.)
YELLOW/BLACK Start Kit
104
Y1
3
YELLOW
S
FOR 208 OPERATION MOVE THIS RED WIRETO 208 VOLT TRANSFORMER TAP
OUTDOOR AIR THERMISTOR
47
86 84
85
BROWN/WHITE
BLACK Outdoor Fan Motor (see chart)
YELLOW BROWN
86
C N FA
22
YELLOW
R
2
69
TERMINAL 23 STRIP
E
YELLOW
BLUE
Yellow
70
RT
57 53
99
Wire Identification numbers for Bard use only. Factory
High Voltage
RM
BLUE
71
W2
99
C
HE
10
BLACK
8
G
99
Compressor
Yellow
RED
6 7
W1
BLACK
5
C
43
BLACK
BLACK/WHITE BLACK/WHITE
RED/WHITE
4
62
RED
T1 T2
GRAY GRAY
Compressor Contactor
BROWN
75
YELLOW/BLACK
Low Pressure Control
60
4
COMP. CCH RELAY (OPT.)
L1 L2
BLUE
3
57
60
BLACK BLACK BLUE
1 2
Return Air Thermistor
GREEN
RED RED BLACK BLACK
1
LPC LPC
Y
R
4 5
C
110
VENT PLUG
2 3 5 + Y U
83
YELLOW/RED YELLOW/RED PINK BLACK/WHITE 57
ALR
CC
63
HPC
Freeze 52 Thermostat
RED RED
Hi Pressure Control
COMPRESSOR CONTROL 20 MODULE
63
ECONOMIZER COMMUNICATION MODULE 42
61
1 Com
49
ECONOMIZER LOGIC CONTROL 40
17
83
15 K Ω
88
51
BLACK/RED BLACK/RED
BLACK RED
19 RESISTOR
ECONOMIZER ENERGY MODULE 41
BLACK 85
3 2
RED RED
82
5
PURPLE
BLACK
POWER LOSS CHANGEOVER RELAY
BLACK RED
81
81
Damper Actuator Motor 2....10 Vdc + 2....10 Vdc + 24 Vac/Vdc
83
RED/WHITE
x
RED
49
82
x
BLACK
14
BLACK
101
BLACK/WHITE
73
49
BLACK
12
79
GREEN
8
x
Input +
RED
49
WHITE
13
18
BLACK 49
BLACK
11
ADJ. + x Output - x +
RED WHITE GREEN
76
RED
7
208/230-60-1
Converter
35 820 Ω RESISTOR
15
9
RED 52 48 Vdc to 24 Vdc
BLACK BLACK/RED BLACK/RED BLACK
14
10
73
GRAY
6
72
BLACK/RED
GRAY
9
80
ORANGE
BLACK
BLACK/WHITE BLACK/WHITE
5
74
67
+
Circuit Breaker
TERM BLOCK 33
ECON CHANGOVER RELAY
77
ORANGE
52 Vdc
31
WHITE
PINK
BLACK/WHITE ORANGE YELLOW
76
64
48
-
48
RED/BLACK
BLACK
72
DANGER
WHITE
BLACK/WHITE
BLACK/RED
1
48
71
BLUE BLACK/WHITE
ORANGE
58
L2
Circuit Breaker
RED RED
58
56
BLACK/WHITE RED
57
ORANGE
BLACK/WHITE
BLACK/WHITE
ORANGE
RED
NO NC 70
ORANGE
T1
48
RED
L1 29
BLACK BLACK
ALARM RELAY
12
67
T2
COM
74
93
56
BLACK
3
92
48
48
BLACK/WHITE
68
WARNING
!
USE COPPER CONDUCTORS ONLY SUITABLE FOR AT LEAST 75° C.
*ELECTRICAL SHOCK HAZARD *DISCONNECT POWER BEFORE SERVICING.
RED BLACK BLACK BLACK
90
67
2
RED
94
89
FILTER RELAY
NO NC
96 27
91
66
12
1
L1 RED
100
RED/WHITE
RED/WHITE COM
75
RED
95
!
RED
56
BLACK
56
BLACK/WHITE
59
ORANGE
103
106
L2
51
RED
HEATER CONTACTOR 1
PURPLE FULL LOAD SPEED RELAY
12
98
T1
102
PURPLE/WHITE
69
T2
1
ECON. BLOWER RELAY
RED
NO NC
ORANGE
1
27
62
GREEN
BLACK/WHITE
RED
48
67
L1
9
COM
50 FILTER SWITCH
L2
NO NC
ORANGE
2
HEATER CONTACTOR 2
PART LOAD SPEED RELAY
12
51 YELLOW/BLK
59
208V
48
240V
YELLOW/RED
48
26
YELLOW/RED
COM
9
48
BLACK BLACK
63
9
PURPLE/WHITE
PRIMARY LIMIT
105
56
65
FL SPEED POTENTIOMETER
3
5 KW HEAT STRIP
97
55
R
GREEN
NO NC
9
BLOWER RELAY
COM
BROWN/WHT BROWN/WHT
YELLOW/BLK
59
ORANGE
56
COM
9
BLACK/WHITE 56
C
1
12
9
4
48
TRANSFORMER
3
ORANGE
PL SPEED POTENTIOMETER
MOTOR PLUG
56
13
9
2 1
BLACK/WHITE
2
ECON SPEED POTENTIOMETER
3
53
48
62
6 5 4
53
BROWN BROWN
12
NO NC
ORANGE
7
PRIMARY LIMIT
5 KW HEAT STRIP
BLACK
COM BLOWER INTERLOCK RELAY
48
8
BROWN
RED/WHITE RED/WHITE
59
64
RED
9
54
RED YELLOW BLUE ORANGE BLACK
BLACK
MOTOR POWER PLUG
BROWN
WHITE
BLUE 3
BLUE ORANGE
CAPACITOR
45
Low Voltage
Field
Optional
Bard Mfg. Co. Bryan, Ohio
4206-101 A