Preview only show first 10 pages with watermark. For full document please download

C-band Solid-state Power Amplifiers

   EMBED


Share

Transcript

C-Band Solid-State Power Amplifiers DPCD, DPCM6450N Using technology developed for ModuMAX™ amplifiers, these outdoor SSPAs feature a modular architecture with field-replaceable RF assemblies and offer an output power of 450 watts across the standard 5.850–6.425 GHz or extended 5.850–6.725 GHz satellite uplink bands. Housed in a weatherproof NEMA 4X enclosure, the amplifiers can be mounted in an antenna hub or outdoors in applications where it is desirable to reduce cable losses by mounting the SSPA close to the antenna. Built for reliable, trouble-free service, the amplifiers incorporate a microprocessor-based monitor and control system. Features Applications • Field-replaceable RF assemblies • Stand-alone SSPA • 450 W saturated output power • 1:1 and 1:2 redundant systems • Microprocessor-based monitor and control • Commercial, Government, and Military systems • Serial interface (RS-232/-422/-485) Options • Output isolator for high load VSWR protection • Block upconverter • 20 dB range digital gain adjustment • RF output sample port • External mute input • Reflected power monitoring Block Diagram SSPA ASSEMBLY PS RF INPUT RF OUTPUT SSPA ASSEMBLY BUC IF INPUT (OPT. 7) RF SAMPLE (-40 dBc) PS REFLECTED POWER DETECTOR AC INPUT SERIAL I/O 1:1 LINK MONITOR/ CONTROL LOGIC Single-Thread SSPA Specifications Parameter Notes Min Frequency Range Band “D” Band “M” Input Frequency Range with Option 7, Block Upconverter Gain, at max. gain setting † Max Units 5.850 5.850 6.425 6.725 GHz GHz Band “D” Band “M” 950 950 1525 1825 MHz MHz Standard With Option 7 70 70 Gain Adjust Range Nom/Typ 73 75 dB dB 20 Gain Flatness Full band, standard Full band, with Option 7 Per 40 MHz, standard Per 40 MHz, with Option 7 Gain Stability vs. Temp. -40 to +50 °C, standard -40 to +50 °C, with Option 7 Power Output Saturated At 1 dB compression (P1 dB) dB ±1.0 ±2.0 ±1.0 ±2.0 ±0.3 ±0.5 dB dB dB dB ±1.5 ±2.5 dB dB +56.5 (450) dBm (W) dBm (W) +56.0 (400) Two-tone Intermodulation At 3 dB total backoff from 1 dB compression point -30 Group Delay Linear Parabolic Ripple AM/PM Conversion At 3 dB backoff from P1 dB 1.0 Noise Figure, at max. gain Standard With Option 7 10 15 VSWR Input, Standard Input, with Option 7 Output -25 0.03 0.003 1.0 1.25 1.35 1.20 Output Sample Port 2.0 Input Output Sample Port Serial I/O 1:1 Link Power Power Requirements Voltage Frequency Power Power factor corrected ns/MHz 2 ns/MHz ns p-p °/dB dB dB 1.30 1.50 1.30 -40 Connectors dBc :1 :1 :1 dBc Type N Female CPR137G Waveguide Type N Female 10-pos MS, mate supplied 6-pos MS, mate supplied 4-pos MS, mate supplied 180 47 2050 0.98 Cooling System 264 63 A 3300 Vac Hz W Forced air Operating Temp. Range Ambient air temperature Weight Approximate Dimensions See outline drawing -40 +50 °C 104 (47) lb (kg) 29.38 H x 21.34 W x 8.82 D 746 H x 542 W x 224 D inches mm † When there is only one value on a line, this column is a nominal value. Otherwise it is a typical value. Typical values are intended to illustrate typical performance, but are not guaranteed. A Cold start, at -40 °C and POUT in saturation. Outline Drawing, SSPA 5.97 [151.7] 0.56 [14.2] DIA THRU (4 PLCS.) 0.87 [22.2] 29.00 [736.6] 8.82 [223.9] AIR EXHAUST 7.91 [200.8] RF OUT CPR 137G FLANGE 29.38 [746.3] AIR INTAKE 15.81 [401.6] 21.34 [542.0] F3 AC LINE FUSE J6 RF SAMPLE TYPE N FEMALE UNIT 2 UNIT 1 60 Decibel Road, Suite 200, State College, PA 16801 USA Telephone: 814-238-2700 • Fax: 814-238-6589 www.gdsatcom.com J6 RF SAMPLE J5 NETWORK J4 SERIAL I/O J7 1:1 / MAINT. SW. J3 AC INPUT J1 RF INPUT L1 VENT LINE FUSES 20A/250V L1 J3 A - Line 1 B - Line 2/Neutral C - GND 0 dBm maximum DO NOT REMOVE CAUTION: FANS DO NOT BLOCK AIRFLOW J5 NETWORK 6-POS MS CONN. L2 CAUTION: FANS DO NOT BLOCK AIRFLOW GORE VENT NOTES: J7 1:1 LINK 6-POS MS CONN. 2. AIR INTAKE AND EXHAUST MUST NOT BE OBSTRUCTED. L2 #10 (0.19 DIA.) GROUND STUD J4 SERIAL I/O 10-POS MS CONN. 1. DIMENSIONS ARE IN INCHES [mm]. J1 RF IN TYPE N FEMALE CAUTION DOUBLE POLE FUSING F1 AC LINE FUSE J3 AC INPUT 3-POS MS CONN. F4 AC LINE FUSE F2 AC LINE FUSE Outline 14408 Part Number/Ordering Information Redundant Systems* (Consists of 1:1 switching assembly, indoor redundancy controller, two SSPAs, and cabling): SSPA: DPC M 6450N-X Part/Model No. 5.850–6.425 GHz = D 5.850–6.725 GHz = M Options: Block Upconverter ............................................ 7 L-Band IF Input * Performance specifications of a redundant system depend on the installed configuration and optional accessories. Contact the factory for more information and for 1:2 system capabilities. Part/Model No. DPRC1 450N -XX 5.850–6.425 GHz = D 5.850–6.725 GHz = M Options: Block Upconverter ........................................... 7 L-Band IF Input Maintenance Switch .............................................A Selects antenna or dummy load at system output Related Accessory: RCP-2001, SSPA Remote Control Panel 1U-high rack-mount panel enables remote manual control of the SSPA. Can be located up to 1.3 km (4000 ft.) away and interconnects with inexpensive cable. Typical 1:1 System Outline MOUNTING SURFACE 11.73 [297.9] 30.13 [765.2] SYSTEM RF OUT CPR137 (G) 13.27 [337.1] WAVEGUIDE MOUNTING SURFACE OPTION A: MAINTENANCE SWITCH 5.88 [149.2] MOUNTING SURFACE MOUNTING SURFACE 11.64 [295.5] SYSTEM RF OUT CPR137 (G) 24.00 [609.6] 12.98 [329.7] WAVEGUIDE MOUNTING SURFACE 8.28 [210.3] 5.88 [149.2] 39.90 [1013.5] MOUNTING SURFACE 30.50 [774.7] AIR EXHAUST 29.00 [736.6] AIR INTAKE 2.62 [66.5] RF/IF IN - TYPE N (F) 0.75 [19.1] 48.00 [1219.2] 46.50 [1181.1] 24.00 [609.5] NOTES: 1) ALL DIMENSIONS ARE IN INCHES [mm]. 2) DO NOT RESTRICT AIR FLOW. Outline 19111 Connector Interface Ref. Des. Function Connector Type Mating Connector Comment J1 RF/IF Input Type N Female Type N Male J2 RF Output CPR137G Waveguide CPR137 Flange J3 AC In 3-pos MS, Male 3-pos MS, Female Mate supplied J4 Serial I/O 10-pos MS, Female 10-pos MS, Male Mate supplied J6 Output Sample Type N Female Type N Male J7 1:1 Link 6-pos MS, Female 6-pos MS, Male Mate supplied 60 Decibel Road, Suite 200 • State College, PA 16801 USA • Tel. +1-814-238-2700 • FAX +1-814-238-6589 Email: [email protected] • www.gdsatcom.com/electronics.php © 2015 General Dynamics. All rights reserved. General Dynamics reserves the right to make changes to its products and specifications at any time and without notice. All trademarks indicated as such herein are trademarks of General Dynamics. All other product and service names are the property of their respective owners. 20790 Rev. B