Transcript
C-Band Solid-State Power Amplifiers DPCD, DPCM6450N Using technology developed for ModuMAX™ amplifiers, these outdoor SSPAs feature a modular architecture with field-replaceable RF assemblies and offer an output power of 450 watts across the standard 5.850–6.425 GHz or extended 5.850–6.725 GHz satellite uplink bands. Housed in a weatherproof NEMA 4X enclosure, the amplifiers can be mounted in an antenna hub or outdoors in applications where it is desirable to reduce cable losses by mounting the SSPA close to the antenna. Built for reliable, trouble-free service, the amplifiers incorporate a microprocessor-based monitor and control system. Features
Applications
• Field-replaceable RF assemblies
• Stand-alone SSPA
• 450 W saturated output power
• 1:1 and 1:2 redundant systems
• Microprocessor-based monitor and control
• Commercial, Government, and Military systems
• Serial interface (RS-232/-422/-485)
Options
• Output isolator for high load VSWR protection
• Block upconverter
• 20 dB range digital gain adjustment • RF output sample port • External mute input • Reflected power monitoring
Block Diagram
SSPA ASSEMBLY
PS RF INPUT
RF OUTPUT SSPA ASSEMBLY
BUC IF INPUT (OPT. 7)
RF SAMPLE (-40 dBc)
PS
REFLECTED POWER DETECTOR AC INPUT
SERIAL I/O
1:1 LINK
MONITOR/ CONTROL LOGIC
Single-Thread SSPA Specifications Parameter
Notes
Min
Frequency Range
Band “D” Band “M”
Input Frequency Range with Option 7, Block Upconverter Gain, at max. gain setting
†
Max
Units
5.850 5.850
6.425 6.725
GHz GHz
Band “D” Band “M”
950 950
1525 1825
MHz MHz
Standard With Option 7
70 70
Gain Adjust Range
Nom/Typ
73 75
dB dB
20
Gain Flatness
Full band, standard Full band, with Option 7 Per 40 MHz, standard Per 40 MHz, with Option 7
Gain Stability vs. Temp.
-40 to +50 °C, standard -40 to +50 °C, with Option 7
Power Output
Saturated At 1 dB compression (P1 dB)
dB
±1.0 ±2.0
±1.0 ±2.0 ±0.3 ±0.5
dB dB dB dB
±1.5 ±2.5
dB dB
+56.5 (450)
dBm (W) dBm (W)
+56.0 (400)
Two-tone Intermodulation
At 3 dB total backoff from 1 dB compression point
-30
Group Delay
Linear Parabolic Ripple
AM/PM Conversion
At 3 dB backoff from P1 dB
1.0
Noise Figure, at max. gain
Standard With Option 7
10 15
VSWR
Input, Standard Input, with Option 7 Output
-25 0.03 0.003 1.0
1.25 1.35 1.20
Output Sample Port
2.0
Input Output Sample Port Serial I/O 1:1 Link Power
Power Requirements
Voltage Frequency Power Power factor corrected
ns/MHz 2 ns/MHz ns p-p °/dB dB dB
1.30 1.50 1.30
-40
Connectors
dBc
:1 :1 :1 dBc
Type N Female CPR137G Waveguide Type N Female 10-pos MS, mate supplied 6-pos MS, mate supplied 4-pos MS, mate supplied 180 47 2050 0.98
Cooling System
264 63 A 3300
Vac Hz W
Forced air
Operating Temp. Range
Ambient air temperature
Weight
Approximate
Dimensions
See outline drawing
-40
+50
°C
104 (47)
lb (kg)
29.38 H x 21.34 W x 8.82 D 746 H x 542 W x 224 D
inches mm
†
When there is only one value on a line, this column is a nominal value. Otherwise it is a typical value. Typical values are intended to illustrate typical performance, but are not guaranteed.
A
Cold start, at -40 °C and POUT in saturation.
Outline Drawing, SSPA 5.97 [151.7]
0.56 [14.2] DIA THRU (4 PLCS.)
0.87 [22.2]
29.00 [736.6]
8.82 [223.9]
AIR EXHAUST
7.91 [200.8]
RF OUT CPR 137G FLANGE
29.38 [746.3]
AIR INTAKE
15.81 [401.6]
21.34 [542.0] F3 AC LINE FUSE J6 RF SAMPLE TYPE N FEMALE
UNIT 2
UNIT 1
60 Decibel Road, Suite 200, State College, PA 16801 USA Telephone: 814-238-2700 • Fax: 814-238-6589 www.gdsatcom.com
J6 RF SAMPLE J5 NETWORK
J4 SERIAL I/O
J7 1:1 / MAINT. SW.
J3 AC INPUT
J1 RF INPUT
L1
VENT
LINE FUSES 20A/250V
L1
J3 A - Line 1 B - Line 2/Neutral C - GND
0 dBm maximum DO NOT REMOVE
CAUTION: FANS DO NOT BLOCK AIRFLOW
J5 NETWORK 6-POS MS CONN.
L2
CAUTION: FANS DO NOT BLOCK AIRFLOW
GORE VENT
NOTES: J7 1:1 LINK 6-POS MS CONN.
2. AIR INTAKE AND EXHAUST MUST NOT BE OBSTRUCTED.
L2
#10 (0.19 DIA.) GROUND STUD
J4 SERIAL I/O 10-POS MS CONN. 1. DIMENSIONS ARE IN INCHES [mm].
J1 RF IN TYPE N FEMALE
CAUTION DOUBLE POLE FUSING
F1 AC LINE FUSE J3 AC INPUT 3-POS MS CONN.
F4 AC LINE FUSE F2 AC LINE FUSE
Outline 14408
Part Number/Ordering Information Redundant Systems* (Consists of 1:1 switching assembly, indoor redundancy controller, two SSPAs, and cabling):
SSPA:
DPC M 6450N-X
Part/Model No.
5.850–6.425 GHz = D 5.850–6.725 GHz = M Options: Block Upconverter ............................................ 7 L-Band IF Input * Performance specifications of a redundant system depend on the installed configuration and optional accessories. Contact the factory for more information and for 1:2 system capabilities.
Part/Model No.
DPRC1
450N -XX
5.850–6.425 GHz = D 5.850–6.725 GHz = M Options: Block Upconverter ........................................... 7 L-Band IF Input Maintenance Switch .............................................A Selects antenna or dummy load at system output
Related Accessory: RCP-2001, SSPA Remote Control Panel 1U-high rack-mount panel enables remote manual control of the SSPA. Can be located up to 1.3 km (4000 ft.) away and interconnects with inexpensive cable.
Typical 1:1 System Outline MOUNTING SURFACE 11.73 [297.9]
30.13 [765.2]
SYSTEM RF OUT CPR137 (G)
13.27 [337.1]
WAVEGUIDE MOUNTING SURFACE
OPTION A: MAINTENANCE SWITCH
5.88 [149.2]
MOUNTING SURFACE
MOUNTING SURFACE 11.64 [295.5]
SYSTEM RF OUT CPR137 (G)
24.00 [609.6]
12.98 [329.7] WAVEGUIDE MOUNTING SURFACE
8.28 [210.3]
5.88 [149.2]
39.90 [1013.5]
MOUNTING SURFACE
30.50 [774.7]
AIR EXHAUST
29.00 [736.6] AIR INTAKE
2.62 [66.5]
RF/IF IN - TYPE N (F) 0.75 [19.1]
48.00 [1219.2]
46.50 [1181.1]
24.00 [609.5]
NOTES: 1) ALL DIMENSIONS ARE IN INCHES [mm]. 2) DO NOT RESTRICT AIR FLOW.
Outline 19111
Connector Interface Ref. Des.
Function
Connector Type
Mating Connector
Comment
J1
RF/IF Input
Type N Female
Type N Male
J2
RF Output
CPR137G Waveguide
CPR137 Flange
J3
AC In
3-pos MS, Male
3-pos MS, Female
Mate supplied
J4
Serial I/O
10-pos MS, Female
10-pos MS, Male
Mate supplied
J6
Output Sample
Type N Female
Type N Male
J7
1:1 Link
6-pos MS, Female
6-pos MS, Male
Mate supplied
60 Decibel Road, Suite 200 • State College, PA 16801 USA • Tel. +1-814-238-2700 • FAX +1-814-238-6589 Email:
[email protected] • www.gdsatcom.com/electronics.php © 2015 General Dynamics. All rights reserved. General Dynamics reserves the right to make changes to its products and specifications at any time and without notice. All trademarks indicated as such herein are trademarks of General Dynamics. All other product and service names are the property of their respective owners.
20790
Rev. B