Preview only show first 10 pages with watermark. For full document please download

+ C Bard Mfg. Co. 1

   EMBED


Share

Transcript

SUPPLY AIR THERMISTOR MOTOR POWER PLUG RED 1 RED BLOWER MOTOR WHITE 2 WHITE BLACK 3 BLACK MOTOR CONTROLLER RED SECONDARY LIMIT 1 RED YELLOW YELLOW 53 2 BLUE 4 ORANGE BROWN 5 BROWN 59 12 102 BLACK/WHITE RED 12 14 77 60 4 78 79 RED/BLACK 9 58 2 6 10 3 7 11 4 8 12 13 16 83 18 11 F 1 Y 2 69 TERMINAL 23 STRIP R BLUE NO NC 111 LOW AMBIENT CONTROL 61 PURPLE 3 Y2 D A LOW VOLTAGE TERMINAL STRIP RED YELLOW S BLUE High Speed Solenoid 1 COMPRESSOR CRANK CASE HEATER (OPT.) YELLOW/BLACK Start Kit 104 FOR 208 OPERATION MOVE THIS RED WIRETO 208 VOLT TRANSFORMER TAP OUTDOOR AIR THERMISTOR 47 86 84 85 BROWN/WHITE BLACK Outdoor Fan Motor (see chart) YELLOW BROWN 86 C N FA 107 BLUE BROWN 61 R RED Y1 22 YELLOW YELLOW BLUE Yellow 70 E 99 C 99 Wire Identification numbers for Bard use only. Factory High Voltage RM 71 RT 99 HE 10 BLUE 9 BLACK 8 W2 62 Compressor Yellow RED 6 7 G 57 53 BLACK RED/WHITE 5 W1 43 BLACK BLACK/WHITE BLACK/WHITE C Compressor Contactor BROWN T1 T2 4 4 COMP. CCH RELAY (OPT.) COM 1 75 YELLOW/BLACK Low Pressure Control 60 BLUE 3 57 L1 L2 BLACK BLACK BLUE 1 2 Return Air Thermistor GREEN RED RED BLACK BLACK Y R LPC LPC C 110 GRAY GRAY ORANGE RED 60 ORANGE 67 87 14 VENT PLUG 2 3 5 + Y U 83 YELLOW/RED YELLOW/RED PINK BLACK/WHITE 57 ALR CC 63 HPC Freeze 52 Thermostat RED RED Hi Pressure Control COMPRESSOR CONTROL 20 MODULE 63 ECONOMIZER COMMUNICATION MODULE 42 61 1 Com 49 ECONOMIZER LOGIC CONTROL 40 17 83 15 K Ω 88 51 BLACK/RED BLACK/RED BLACK RED 19 RESISTOR ECONOMIZER ENERGY MODULE 41 BLACK 85 4 5 48 5 3 2 RED RED 82 1 PURPLE BLACK POWER LOSS CHANGEOVER RELAY BLACK RED 81 Damper Actuator Motor 2....10 Vdc + 2....10 Vdc + 24 Vac/Vdc 83 RED/WHITE BLACK/WHITE 73 80 81 RED 49 BLACK 8 18 RED 11 x BLACK 74 7 82 x BLACK 101 15 WHITE 13 49 GREEN 14 10 79 BLACK BLACK/RED BLACK/RED BLACK 6 x Input + RED 49 GRAY 77 ADJ. + x Output - x + BLACK 49 GRAY 9 5 76 ECON CHANGOVER RELAY 74 ORANGE Converter 35 820 Ω RESISTOR BLACK/WHITE ORANGE YELLOW 76 73 52 48 Vdc to 24 Vdc BLACK ORANGE 72 72 BLACK/RED TERM BLOCK 33 BLACK/WHITE BLACK/RED 57 WHITE PINK 71 64 ORANGE RED/BLACK BLACK/WHITE RED BLUE BLACK/WHITE 3 WHITE ALARM RELAY NO NC 70 67 RED + Circuit Breaker RED WHITE GREEN 68 12 2 58 52 Vdc 31 RED RED 58 56 - 48 56 COM 1 48 BLACK BLACK 48 BLACK/WHITE L2 Circuit Breaker 48 48 FILTER RELAY NO NC BLACK 75 29 208/230-60-1 90 67 56 RED BLACK BLACK 66 12 ORANGE 91 L1 94 89 RED/WHITE COM DANGER *ELECTRICAL SHOCK HAZARD *DISCONNECT POWER BEFORE SERVICING. 100 RED RED/WHITE WARNING ! USE COPPER CONDUCTORS ONLY SUITABLE FOR AT LEAST 75° C. ! BLACK/WHITE 59 96 27 56 PURPLE/WHITE 69 T1 51 95 HEATER CONTACTOR 1 PURPLE FULL LOAD SPEED RELAY 12 NO NC ORANGE RED RED 48 67 T2 BLACK/WHITE RED COM 50 FILTER SWITCH BLACK L1 9 ORANGE 103 BLACK BLACK/WHITE 1 ECON. BLOWER RELAY L2 NO NC RED 62 GREEN PART LOAD SPEED RELAY 12 51 YELLOW/BLK 59 208V YELLOW/RED 48 26 48 RED 48 BLACK BLACK BLACK BLACK/WHITE ORANGE BLOWER RELAY YELLOW/RED COM 9 ORANGE 63 9 PURPLE/WHITE 1 55 56 65 FL SPEED POTENTIOMETER PRIMARY LIMIT 2 59 240V GREEN NO NC 9 56 R BROWN/WHT BROWN/WHT YELLOW/BLK BLACK/WHITE 56 COM 9 5 KW HEAT STRIP COM 1 12 9 48 C 3 ORANGE PL SPEED POTENTIOMETER MOTOR PLUG 56 13 9 2 1 BLACK/WHITE 2 ECON SPEED POTENTIOMETER 3 53 48 62 6 5 4 53 BROWN BROWN NO NC ORANGE 7 TRANSFORMER 48 8 BROWN RED/WHITE RED/WHITE COM BLOWER INTERLOCK RELAY 64 RED 9 54 RED YELLOW BLUE ORANGE BLACK BLACK MOTOR POWER PLUG BROWN WHITE WHITE 3 BLUE ORANGE CAPACITOR 45 Low Voltage Field Optional Bard Mfg. Co. Bryan, Ohio 4206-104 A