Transcript
°C Breeze™
Condensed Moisture Airflow Visualization Instrument overview
The °C Breeze Fog Instrumentation system is used for the visualization of airflow profiles, using lowimpulse, thermally neutral fog. This handheld device allows mobility in large areas or remote locations where a direct connection to power is not practical. The °C Breeze provides a steady stream of condensed fog, capable of filling 3 m3 [100 ft3] in constant-on mode, before evaporating. The micro-sized fog particles provide excellent air flow visibility without premature settling or dispersion. The supplied nozzle extension tube allows precise fog delivery into small spaces. This easy-to-operate unit produces fog quickly with virtually no warm-up delay. Fog may be generated continuously for 10 minutes on a single battery charge, or, using the optional 110/230V AC wall power supply, fog can be generated continuously for a period of up to one hour. The °C Breeze uses a high quality, FDA Generally Recognized As Safe “GRAS”, approved chemistry for a clean, safe, non-toxic fluid. Applications include microbiological safety cabinet and chemical fume hood certification, critical containment verification for medical and clean technology, building ventilation testing, electronic system cooling design studies, and generalized flow visualization work.
features
• Easy-to-use, battery operated, handheld portable fogging device • Neutral density, nontoxic fog, traces airflow profiles • High opacity and long visual latency to meet your application needs • Uses FDA GRAS approved, non-depositing, oilless and smoke-free fog fluid • Useful for overhead or under floor applications • Starts in seconds, no warm-up delay • Switch options include constant-on or toggle on/off fog delivery • Includes battery charger with illuminating LED charge indicator • International power plug adapters available • Wireless, remote control available • Dedicated power supply for continuous (batteryless) operation available
Engineered Airflow. Intelligent Cooling.
The °C Breeze System comes with: °C Breeze Visualization Instrument Locking Carrying Case with Keys Nozzle Extension Tube, 200 mm [8”] 500 ml [17 oz] Fluid Bottle 12 VDC Lead Acid Battery Battery Charger User Manual Quick Start Guide Material Safety Data Sheet (MSDS)
applications • NSF 49/ANSI Testing Microbiological Safety Cabinet Chemical Fume Hood Clean environment containment validation • Filter challenging • HVAC Ventilation Performance Tests • Local Exhaust Ventilation (COSHH regulations) testing • Building Envelope Commissioning (NIBS 3-2012) tests • Data Center Airflow Visualization • Electronics Cooling Design Verification • General testing of air-cooled product prototypes
www.degreeC.com • sales@ degreeC.com
18 Meadowbrook Drive, Milford, NH 03055 • TEL: 603-672-8900 or 1-877-DEGREEC • FAX: 603-672-9565
specifications
°C Breeze Instrument Weight
2.7 kg [6 lbs]
°C Breeze Instrument Dimensions
227 mm x 66 mm x 81 mm [8.9” x 2.6” x 3.2”]
Power Consumption
75 W
Battery (Supplied)
12 VDC / 2.3Ah
Charger Power Requirements
100-240V ~2A, 50/60 Hz
Fog Output
3 m3/min [100 cfm]
Fog Fluid Reservoir Capacity
110 mL [3.7 oz]
Fog Fluid Consumption
2 mL/min [0.07 oz/min]
Spare Fluid Bottle Capacity
500 mL [17 oz] >5 hours continuous operation
Fog Fluid Composition
Propylene Glycol – FDA GRAS
Fog Composition
Condensed moisture vapor
This Product Uses Propylene Glycol Only use Degree Controls, Inc. Fog Fluid, PN MS191, in your °C Breeze Airflow Visualization Instrument. Only the °C Breeze Fog Fluid meets the equipment’s purity grade needed for the °C Breeze Fogger. Using entertainment-grade fog chemicals will invalidate the product warrantee and clog the internal precision components of the °C Breeze product. Entertainment grade fog chemicals may be dangerous to your health and may deposit residues onto your product or test surfaces. °C Breeze Fog Fluid is safe and harmless to individuals when used as directed
accessories
• • • • • • • • •
Wireless Remote Control Receiver (315 MHz US) & Wireless Key FOB Transceiver Dedicated Power Supply for Continuous (battery-less) Operation 12 VDC Lead Acid Battery Battery Charger for Lead Acid Battery 12 VDC Ni-MH Battery Battery Charger for Ni-MH Battery International plug adapters for battery charger Nozzle Extension Tube, 200 mm [8”] 500 mL [17 oz] Fog Fluid Bottle
Standard Instrument, Case, and Components • °C Breeze Condensed Moisture Airflow Visualization Kit
part # MS193 part # MS192 part # BA004 part # MS194 part # BA006 CALL CALL part #MS187 part # MS191 part # FM51300
Degree Controls, Inc. is an ISO-9001 certified world-class Designer and Turn-Key Manufacturer of control solutions for progressive technology industries. With over 15 years of proven experience, we pride ourselves in delivering solutions to our customers that provide the differentiation they need for their rapidly changing competitive landscape.
Remote Control Operation.
Dedicated Power Supply for Continuous Operation (includes proxy battery)
© 2013 DEGREE CONTROLS, INC. 51300DS000-A00 rev. A-2c
Engineered Airflow. Intelligent Cooling.
www.degreeC.com • sales@ degreeC.com
18 Meadowbrook Drive, Milford, NH 03055 • TEL: 603-672-8900 or 1-877-DEGREEC • FAX: 603-672-9565
quick start guide
°C Breeze
Condensed Moisture Airflow Visualization ºC Breeze Leftside View Power Button Tank Fluid Cap Tube Breather Holes Fluid Tank Level
TM
Battery Clip
Extension Tube
Battery Compartment
Battery
ºC Breeze Rightside View Signal LED
Tank Fluid Cap
Power Button
Extension Tube Insertion Fluid Tank Level
Extension Tube
Remote Control Connection
Momentary & Toggle Switch
Tube Breather Holes
The °C Breeze uses pharmaceutical grade FDA GRAS certified Propylene Glycol which when heated adheres to Hydrogen/Oxygen gases in the air and forms a highly visible Condensed Moisture “fog” which follows air movement and evaporates as Carbon Dioxide in micro-sized water droplets. There is virtually no odor or oily residue which can be found in other smoke systems.
step 1 Remove all contents from the °C Breeze Carrying Case. Check that all plastic padding is removed, especially in the nozzle area.
step 2 Charge the battery. Connect charging head to battery, plug in the power adaptor to a ground electrical outlet and a green light will light up. Initial charge will take approximately 8 hours, thereafter 2-3 hours.
step 3
step 4
Fill the unit with °C Breeze Fog Fluid. When tank is filled, place caps back on bottle and tank and tighten.
Install a charged battery, terminal side first. Align the battery with the electrical contact of the battery on the right hand side of the center line and slide battery all the way in.
step 5
step 6
Install the extension tube (this is optional as the unit can be run with or without the extension tube). Make sure the breather holes are at the end closest to the machine.
Power on the unit by pressing the button on the handle. The LED will flash green, and after 1 or 2 seconds fog will be produced. The unit requires no warm-up time, so you can be started instantly.
Momentary
Toggle
step 6a
step 7
Select one of the two operation modes: Momentary (←)Mode, slide switch on the right hand side of the machine to the left towards the reservoir (only when the fog button is held down). Toggle (→) Mode, slide switch to the right towards the fog outlet (pressing the fog button once fog starts, pressing again to stop fog).
Powering down the machine. Press the red button on the handle. Fog will stop flowing out and the green light will turn off. When done, remove the battery for optimal battery life and drain fluid tank to educe the effects of oxidation on internal components and safe storage. Use only Degree Controls °C Breeze fog fluid in this device.
© 2013 Degree Controls, Inc. all rights reserved 51300MN000-A00 QS rev. 1-A
Engineered Airflow. Intelligent Cooling.
www.degreec.com • sales@ degreec.com
18 Meadowbrook Drive, Milford, NH 03055 • TEL: 603-672-8900 or 1-877-DEGREEC • FAX: 603-672-9565
Material Safety Data Sheet
U.S. Department of Labor
May be used to comply with OSHA’s Hazard Communication Standard, 29 CFR 1910 1200. Standard must be consulted for specific requirements.
Occupational Safety and Health Administration (Non-Mandatory Form) Form Approved OMB No. 1218-0072 Note: Blank spaces are not permitted. If any item is not applicable or no information is available, the space must be marked to indicate that.
IDENTITY (as Used on Label and List) °C Breeze Condensed Moisture Fog System Section I Manufacturer’s name
Degree Controls, Inc.
Emergency Telephone Number
603-672-8900
Address (Number, Street, City, State and ZIP Code)
Telephone Number for Information
18 Meadowbrook Drive
Date Prepared
Milford, NH 03055
Signature of Preparer (optional)
603-672-8900
July 30, 2013
Section II—Hazardous Ingredients/Identity Information Hazardous Components (Specific Chemical Identity, Common Name(s)
A chemical of water miscible pharmaceutical grade non-toxic
OSHA PEL
Other Limits Recommended
ACGIH TLV
% (optional)
propylene glycol preparation meeting USP purity requirements CAS# 57-55-6
10 mg/m3 WEEL
CAS# 57-81-5
10 ppm (mist)
99 - 100%
CAS# 7732-18-5
Section III—Physical/Chemical Characteristics Boiling Point 188.2C (370F)
Specific Gravity (H20 = 1)
0.0361 @ 20C/4C
Vapor Pressure (mm Hg)
0.129 @ 25C (77F)
Melting Point
-59C (-74F)
Vapor Density (AIR = 1)
2.6
Evaporation Rate (Butyl Acetate = 1)
0.01
Solubility in Water
Miscible
Appearance and Odor
Clear oily and odorless liquid
Section IV—Fire and Explosion Hazard Data Flash Point (Method Used) 99C (210F)
Flammable Limits
LEL
2.6
UEL
12.5
in air % by volume Extinguishing Media
Use fire extinguishing media appropriate to the surroundings
Special Fire Fighting Procedures
Self-contained breathing apparatus
Unusual Fire and Explosion Hazards
None
(Reproduce locally)
Degree Controls, Inc. DOCUMENT CONTROL 51300DS000-A00
OSHA 174 Sept. 1985
Page 1
Section V—Reactivity Data Stability
Unstable
Conditions to Avoid
X
Stable
Heat, flames, ignition sources and incompatibles
Strong oxidizing agents
Incompatibility (Materials to Avoid)
Hazardous Decomposition or Byproducts
Carbon dioxide and monoxide may form when heated to decomposition. Aldehydes or lactic,
pyruvic or acetic acids may also be formed. May Occur
Hazardous Polymerization
Conditions to Avoid
Will Not Occur
X
Heat, flames, ignition sources and incompatibles
Section VI—Health Hazard Data Route(s) of Entry
X
Inhalation?
N/A
Ingestion?
N/A
None in the normal use of this product for airflow visualization applications
Health Hazards (Acute and Chronic)
Carcinogenicity
NTP?
Signs and Symptoms of Exposure
Skin?
No
No
IARC Monographs?
OSHA Regulated?
No
No symptoms – practically non-toxic.
Medical Conditions Generally Aggravated by Exposure
None known. Product and generated fog are practically non-toxic.
Emergency and First Aid Procedures
EYES: flush with water, remove contact lenses and continue flushing. If hot droplets reach the eye seek medical attention. INHALATION: not normal route for vaporized fluid – remove from exposure. INGESTION: seek medical attention.
Section VII—Precautions for Safe Handling and Use Steps to Be Taken in Case Material Is Released or Spilled
Wash off any spillage with water
Waste Disposal Method
Follow all Federal, state and local regulations regarding disposals
Precautions to Be Taken in Handling and Storing
Other Precautions
Keep out of reach of children
Never apply artificial fog in someone’s face. Slippery if split.
Section VII—Control Measures Respiratory Protection (Specify Type) Ventilation
Local Exhaust
Recommended, though not required
Mechanical (General) Protective Gloves
None required in the concentrations used for airflow tracing applications
None required
Recommended, though not required
Other Protective Clothing or Equipment Work/Hygienic Practices
Special Other Eye Protection
None required None required Goggles recommended, though not required
Clean body-covering clothing recommended, though not required
N/A
Degree Controls, Inc. DOCUMENT CONTROL 51300DS000-A00
Page 2