Preview only show first 10 pages with watermark. For full document please download

C000dd2d Spec Eng

   EMBED


Share

Transcript

CLICK CPU Module Specifications PLC Overview CLICK PLC C0-00DD2-D C0-00DD2-D Built-in I/O Specifications - Inputs <---> 8 DC Inputs/6 Sourcing DC Outputs CLICK PLC CPU, 8 DC input/6 Sourcing DC output, 8K steps total program memory, Ladder Logic programming, built-in RS232C programming port and additional RS232C Modbus RTU/ASCII communications port (configurable up to 115200 baud). Inputs: 8-pts 24 VDC Sink/Source inputs, 2 commons, isolated. Outputs: 6-pts 24 VDC Sourcing outputs, 0.1 A/pt, 2 commons, isolated. Removable terminal block included, replacement ADC p/n C0-16TB. C1 + + X4 + X5 X6 ON to OFF Response + X7 X8 Status Indicators Commons Y1 L Y2 L Y3 L Y4 L Y6 L + L CO C0-00DD2-D - 24 VDC Power Current Consumption 120 mA Equivalent Input Circuit 2 (4 points/common) Isolated Outputs per Module Operating Voltage Range Maximum Output Current Minimum Output Current Maximum Leakage Current On Voltage Drop Maximum Inrush Current Internal Module Circuitry OFF to ON Response Optical Isolator ON to OFF Response + 24 VDC Status Indicators Commons C1 COM 6 (Source) 19.2-30 VDC 0.1 A/point , 0.8 A/common 0.2 mA 0.1 mA @ 30 VDC Y1: 1.0 VDC @ 0.1 A Y2-6: 0.5 VDC @ 0.1 A 150 mA for 10 ms Y1: typ 5 μs; max 20 μs Y2-6: < 0.5 ms Y1: typ 5 μs; max 20 μs Y2-6: < 0.5 ms Logic Side (6 points, red LED) 2 (4 points/com & 2 points/com) Isolated To X2-X4 commons DL305 PLC DL405 PLC Field I/O Software C-more HMIs Other HMI AC Drives Motors Steppers/ Servos Motor Controls Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Optical Isolator INPUT X5-X8 Typical + DL205 PLC Logic Side (8 points, green LED) C0-00DD2-D Built-in I/O Specifications - Outputs 24VDC V2 Y5 8 (Sink/Source) 24 VDC 21.6 - 26.4 VDC X1-2: Typ 5 mA @ 24 VDC X3-8: Typ 4 mA @ 24 VDC X1-2: 6.0 mA @ 26.4 VDC X3-8: 5.0 mA @ 26.4 VDC X1-2: 4.7 k⏲ @ 24 VDC X3-8: 6.8 k⏲ @ 24 VDC X1-2: > 19 VDC X3-8: > 19 VDC X1-2: < 4 VDC X3-8: < 7 VDC X1-2: 4.5 mA X3-8: 3.5 mA X1-2: 0.1 mA X3-8: 0.5 mA X1-2: Typ 5 μs Max 20 μs X3-8: Typ 2 ms Max 10 ms X1-2: Typ 5 μs Max 20 μs X3-8: Typ 3 ms Max 10 ms + V1 + ON Voltage Level OFF to ON Response C2 INPUT X1-X4 Typical Input Impedance Maximum OFF Current X2 X3 Maximum Input Current Minimum ON Current 24VDC X1 Input Current OFF Voltage Level Wiring Diagram C0-00DD2-D Inputs per Module Operating Voltage Range Input Voltage Range DL105 PLC C0-00DD2-D Temperature Derating Chart Pushbuttons/ Lights 8 + Inputs 24 VDC Process 6 Points C2 COM To X6-X8 commons Outputs 4 Relays/ Timers 2 Equivalent Output Circuit 0 24 VDC + V1 +V To Y2-Y4 circuits Internal Module Circuitry Comm. 0 32 10 50 20 68 30 85 40 104 50 55 °C 122 131 °F Surrounding Air Temperature (°C/°F) TB’s & Wiring Optical Isolator L From COM OUTPUT Y1 24 VDC + V2 +V ZipLink Pre-Wired PLC Connection Cables and Modules Power To Y6 circuit Circuit Protection Optical Isolator Enclosures L OUTPUT Y5 CO COM To Y1-Y4 & Y6 commons w w w. a u to m at i o n d i re c t . c o m / C L I C K ZL-RTB20 20-pin feed-through connector module 20-pin connector cable ZL-C0-CBL20 (0.5 m length) ZL-C0-CBL20-1 (1.0 m length) ZL-C0-CBL20-2 (2.0 m length) PLC Products A-19 Appendix Part Index CLICK Specifications PLC Overview CLICK PLC General specifications (all CLICK PLC products) These general specifications apply to all CLICK CPUs, optional I/O modules, and optional power supply products. Please refer to the appropriate I/O temperature derating charts under both the CPU and I/O module specifications to determine best operating conditions based on the ambient temperature of your particular application. DL105 PLC Environmental Specifications Operating Temperature Storage Temperature Ambient Humidity Environmental Air Vibration Shock Noise Immunity Emissions Agency Approvals Other 32°F to 131°F (0°C to 55°C) IEC 60068-2-14 (Test Nb, Thermal Shock) –4°F to 158°F (–20°C to 70°C) IEC 60068-2-1 (Test Ab, Cold) IEC 60068-2-2 (Test Bb, Dry Heat) IEC 60068-2-14 (Test Na, Thermal Shock) 30% to 95% relative humidity (non–condensing) No corrosive gases The level for the environmental pollution is 2 (UL840) MIL STD 810C, Method 514.2 IEC60068-2-6 JIS C60068-2-6 (Sine wave vibration test) MIL STD 810C, Method 516.2 IEC60068-2-27 JIS C60068-2-27 Comply with NEMA ICS3-304 Impulse noise 1μs, 1000V EN61000-4-2 (ESD) EN61000-4-3 (RFI) EN61000-4-4 (FTB) EN61000-4-5 (Surge) EN61000-4-6 (Conducted) EN61000-4-8 (Power frequency magnetic field immunity) RFI: No interference measured between 150-450MHz (5w/15cm) EN55011:1998 Class A UL508 CE (EN61131-2) RoHS instruction conformity DL205 PLC DL305 PLC DL405 PLC Field I/O Software C-more HMIs Other HMI AC Drives Motors Steppers/ Servos Motor Controls CPU Module Specifications CPU module specifications These specifications apply to all the CPU modules. Control Method I/O Numbering System Ladder Memory (steps) Total Data Memory (words) Contact Execution (boolean) Typical Scan (1k boolean) RLL Ladder Style Programming Run Time Edits Scan CLICK Programming Software for Windows Built-in Communication Ports (RS-232) FLASH Memory Built-in Discrete I/O points Number of Instructions Available Control Relays Special Relays (system defined) Timers Counters Immediate I/O Interrupts (external / timed) Subroutines For/Next Loops Math (Integer and Floating Point) Drum Sequencer Instruction Internal Diagnostics Password Security System Error Log User Error Log Memory Backup Battery Backup I/O Terminal Block Replacement AC Power Terminal Block Replacement w w w. a u to m at i o n d i re c t . c o m / C L I C K Stored Program/Cyclic execution method Fixed in Decimal 8000 8000 < 0.6us 1-2 ms Yes No Variable / fixed Yes Yes (2) Standard on CPU 8 inputs, 6 outputs 21 2000 1000 500 250 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Super Capacitor No ADC p/n C0-16TB ADC p/n C0-4TB PLC Products A-15 Proximity Sensors Photo Sensors Limit Switches Encoders Current Sensors Pushbuttons/ Lights Process Relays/ Timers Comm. TB’s & Wiring Power Circuit Protection Enclosures Appendix Part Index CLICK Specifications CPU features Mounting Tab Model Number Sliding Latch Run/Stop Switch Discrete Input Points DIN Rail Slot and I/O Module Port Extension LED Status Indicators Discrete Output Points Communications Ports I/O Status Indicators Sliding Latch 24 VDC Power Connector Removable I/O Terminal Block Mounting Tab CPU LED status indicators CLICK LED Status Indicators POWER LED (Green) On Power Good Off Power Failure C0-00DD1-D C1 RUN LED (Green) On CPU Run Mode Off CPU Stopped or Prog. Mode X1 X2 X3 PWR On Off Self Diagnostic Error No Error TX & RX LED (Green) X4 C2 RUN ERR ERROR LED (RED) RUN STOP X5 INPUT LEDs (Green) On Input True Off Input False X6 PORT1 X7 X8 TX1 RX1 C3 TX2 Y1 RX2 Y2 OUTPUT LEDs (Red) Y3 PORT2 Y4 On Comm Port Data Active C4 Off No Communication Y5 On Output True Off Output False Y6 +V I/O Terminal block specifications for CPUs and I/O Modules 11-pin Terminal Block Specifications Connector Type Number of Pins Pitch Wire Range Wire Strip Length Screw Size Screw Torque ADC Part Number A-16 Pluggable Terminal Block 11 pt 3.50 mm 28-16 AWG 7 mm M2.0 2.0 to 2.2 lb-inch C0-8TB PLC Products 20-pin Terminal Block Specifications 11-Pin Terminal Block, C0-8TB 20-Pin Terminal Block, C0-16TB Connector Type Number of Pins Pitch Wire Range Wire Strip Length Screw Size Screw Torque ADC Part Number Pluggable Terminal Block 20 pt 3.50 mm 28-16 AWG 7 mm M2.0 2.0 to 2.2 lb-inch C0-16TB 1 - 80 0 - 633 - 0405 Product Dimensions and Installation Ground Braid Copper Lugs It is important to understand the installation requirements for your CLICK system. Your knowledge of these requirements will help ensure that your system operates within its environmental and electrical limits. Panel or Single Point Ground Panel Plan for safety Star Washers This catalog should never be used as a replacement for the user manual. You can purchase, download free, or view online the user manuals for these products. The C0-USER-M is the publication for the CLICK PLC. This user manual contains important safety information that must be followed. The system installation should comply with all appropriate electrical codes and standards. Star Washers 2" 50.8mm minimum 2" 50.8mm minimum 3" 76.2mm minimum NOTE: There is a mimimum clearance requirement of 2” (51 mm) between the CLICK PLC and the panel door or any devices mounted in the panel door. The same clearance is required between the PLC and any side of the enclosure. A minimum clearance of 3” (76 mm) is required between the PLC and a wireway or any heat producing device. A-6 PLC Products PORT1 TX1 RX1 TX2 RX2 PORT2 RUN PWR RUN ERR CLICK PLCs must be mounted properly to ensure ample airflow for cooling purposes. It is important to follow the unit orientation requirements and to verify that the PLC’s dimensions are compatible with your application. Notice particularly the grounding requirements and the recommended cabinet clearances. STOP Mounting orientation Air Flow 1 - 80 0 - 633 - 0405 Product Dimensions and Installation PLC Overview CLICK PLC Latch tabs DL105 PLC 3 Connecting the modules together Connecting Modules DL205 PLC CLICK CPUs, I/O modules and power supplies connect together using the extension ports that are located on the side panels of the modules (no PLC backplane/base required). 1) Remove extension port covers and slide the latch tabs forward. 2) Align the module pins and connection plug, and press the I/O module onto the right side of the CPU. 3) Slide the latch tabs backward to lock the modules together. 2 DL305 PLC DL405 PLC Field I/O Software 1 C-more HMIs Other HMI AC Drives Motors Supports up to eight I/O modules Steppers/ Servos Motor Controls DIN Rail Mounting Surface Mounting Mounting Upper Mounting Tab Proximity Sensors Photo Sensors The CLICK PLC system, which includes the CLICK power supplies, CPU modules, and I/O modules, can be mounted in one of two ways. 1) DIN rail mounted 2) Surface mounted using the built-in upper and lower mounting tabs. Limit Switches Encoders Current Sensors Pull tab down. Push tab up until... Lower Mounting Tab Click Pushbuttons/ Lights Process Power Supply Module Unit dimensions These diagrams show the outside dimensions of the CLICK power suppy, CPU, and I/O modules. The CLICK PLC system is designed to be mounted on standard 35mm DIN rail, or it can be surface mounted. Allow proper spacing from components within an enclosure. CPU Module 1.37" 34.9mm 0.102" 2.6mm 2.11" 53.5mm I/O Module 1.06" 27mm Relays/ Timers 0.46" 13.5mm 2.95" 75mm Comm. 0.37" 9.4mm TB’s & Wiring Power other 3.35" 85mm Circuit Protection Maximum system: Enclosures Power Supply + CPU + 8 I/O modules. 0.16" 4mm Appendix 0.36" 9.2mm " Part Index w w w. a u to m at i o n d i re c t . c o m / C L I C K PLC Products A-7 Product Dimensions and Installation Unit dimensions 1.37" 34.9mm Power Supply 0.10" 2.6mm 0.53" 13.5mm 2.95" 75mm C0-00AC OUTPUT 24V 0.5A 3.64" 92.4mm 3.35" 85mm 85 NOTE: The dimensions for the C0-00AC and C0-01AC power supplies are the same. 24V 0V G L N INPUT 100-240V 15VA 50-60Hz 0.16" 4mm CPU Module 0.19" 4.8mm 0.10" 2.6mm 2.11" 53.6mm 0.37" 9.4mm 0.2" 5mm 2.95" 75mm CLICK CPU MODULE PWR RUN ERR 3.35" 85mm RUN STOP PORT1 TX1 RX1 3.66" 93mm TX2 RX2 PORT2 0.36" 9.2mm I/O Module 0.33" 8.5mm 1.06" 27mm 0.10" 2.6mm 0.37" 9.4mm 2.95" 75mm CLICK I/O MODULE 3.6" 92.4mm 3.35" 85mm 0.16" 4mm A-8 PLC Products 1 - 80 0 - 633 - 0405