Preview only show first 10 pages with watermark. For full document please download

C07-7-e16a1 User Operation

   EMBED


Share

Transcript

C07-7-E16A1 USER OPERATION \USEBOOK\C\07\7\E\16\A\1\E16A1_E.DOC Mode: C07-7-E16A1 3 - 0 CONTENT 1. Operating Panel..................................... 3-2 2. Display Section ..................................... 3-3 3. Operation Setting .................................. 3-4 4. Counter Setting ..................................... 3-7 5. Switch Setting ....................................... 3-8 6. Other Switches Setting......................... 3-9 7. Time Setting........................................... 3-10 8. Abnormal Display.................................. 3-11 \USEBOOK\C\07\7\E\16\A\1\E16A1_E.DOC Mode: C07-7-E16A1 3 - 1 1.Operating Panel WORK LENG CNT TOT : 1234/Min : 1234.12mm : 1234 : 123456 / Keypad Other Switches Setting (see 6) Chinese /English version change-over key Time Setting area (see7) Return to Main display Cutting Distance (see 5) Display Section (see 2) Collector (see 5) Counter Setting (see 4) Work Setting area (see 3) \USEBOOK\C\07\7\E\16\A\1\E16A1_E.DOC Mode: C07-7-E16A1 3 - 2 2. Display Section 2.1 Display summary; Divide into ‘Main display’、’Other switches setting’、’Time setting’ and ’parameter display’. Main display: WORK LENG CNT TOT : 1234/Min : 1234.12mm : 1234 : 123456 Other switches setting: TOTAL SET MULTIPLE MODE GAP 1 REH / ( ) : 999 PCS/Min :2 :SKIP : 50 PCS CNT :NON STOP TRIM :MANU FILM STOP :ON PUN ULTRASONIC 1:ON NOW VALUE :100 m Time setting: ( ) CONVEYOR :5 S CONVERYOR 2 TIME:5 S PUNCH 1 TIME :0.5 S PUNCH 2 TIME :0.5 S DELY WASTE PUN :1 S WASTE PUN TIME :1 S PUN ULTRASONIC 1:1 S \USEBOOK\C\07\7\E\16\A\1\E16A1_E.DOC Mode: C07-7-E16A1 3 - 3 3. Operation Setting 3.1 ‘Sheet/Min’ key  When touching ‘Sheet/Min’ key, ‘WORK’ of the display is blinking. Blinking WORK LENG CNT TOT :1234/Min :1234.12mm : 1234 : 123456 /  Touching keypad to change setting value. Then push ‘ ‘ key to confirm and stop the blinking; but push ‘Main’ key, the value is not changed and the blinking is stop. 3.2 Setting of ‘LENGTH SET’, ’PRINTED/PLAIN’, ’LIGHT/DARK’, and ‘STOP/ALARM’ 3.2.1 ‘LENGTH SET’ key  When touching ‘Length set’ key, ‘LENG’ of the display is blinking. Blinking WORK LENG CNT TOT :1234/Min :1234.12mm : 1234 : 123456 /  Touching keypad to change setting value, then push ‘ ‘ key to confirm and stop the blinking; but push ‘Main’ key, the value is not changed and the blinking is stopped. \USEBOOK\C\07\7\E\16\A\1\E16A1_E.DOC Mode: C07-7-E16A1 3 - 4 3.2.2 ‘PRINTED/PLAIN’ key Pushing ‘Printed/Plain’ key to changed over ‘Printed mode’ / ‘Plain mode’. WORK LENG CNT TOT :1234/Min :1234.12mm : 1234 : 123456 WORK LENG CNT TOT :1234/Min :1234.12mm : 1234 : 123456 / Printed mode Plain mode 3.2.3 ‘LIGHT/DARK’ key Pushing ‘Light/Dark’ key to changed over ‘Light mode’ /’Dark mode’ in Printed mode. WORK LENG CNT TOT :1234/Min :1234.12mm : 1234 : 123456 WORK LENG CNT TOT :1234/Min :1234.12mm : 1234 : 123456 Dark mode / Light mode / 3.2.4 ‘STOP/ALARM’ key Pushing ‘Stop/Alarm’ key to changed over ‘Stop mode’ /’Alarm mode’ in Printed mode. WORK LENG CNT TOT :1234/Min :1234.12mm : 1234 : 123456 WORK LENG CNT TOT :1234/Min :1234.12mm : 1234 : 123456 \USEBOOK\C\07\7\E\16\A\1\E16A1_E.DOC / Alarm mode / Stop mode Mode: C07-7-E16A1 3 - 5 4. Counter Setting 4.1 ‘SET’ key WORK LENG NUM TOT :1234/Min :1234.12mm : 1234 : 123456 / Pushing ‘SET’ key once, ‘CNT’ is changed to ‘NUM’ and blinking. WORK LENG AHD TOT :1234/Min :1234.12mm : 1234 : 123456 / Pushing ‘SET’ key again, ‘NUM’ is changed to ‘AHD’ and blinking. Pushing keypad to change setting value, then pushing ‘ ‘ key to confirm and stop the blink, but push ‘Main’ key, the value is not changed and the blinking is stopped. 4.2 ‘CLEAR’ key Pushing ‘Clear’ key to clear counter value. 4.3 ‘TOTAL CLEAR’ key Pushing ‘Total clear’ key to clear total counter value. 4.4 ’PAUSE’ key Pushing ‘Pause’ key to pause count, then push once again to continue count. \USEBOOK\C\07\7\E\16\A\1\E16A1_E.DOC Mode: C07-7-E16A1 3 - 6 5. Switch Setting 5.1 ‘COLLECTOR’ key Pushing ‘Collector’ key to change over Index/Continuous/Stop. WORK LENG CNT TOT :1234/Min :1234.12mm : 1234 : 123456 / WORK LENG CNT TOT :1234/Min :1234.12mm : 1234 : 123456 / WORK LENG CNT TOT :1234/Min :1234.12mm : 1234 : 123456 / INDEX CONTINUOUS STOP 5.2 ‘CUTTING DISTANCE’ key When push the key of ‘Cutting Distance’ during stop, the display is as below. Please operation by the display. 0000.00mm Moving distance. \USEBOOK\C\07\7\E\16\A\1\E16A1_E.DOC Mode: C07-7-E16A1 3 - 7 6. Other Switches Setting 6.1 ‘OTHER SWITCH’ key Pushing ‘Other Switch’ key to change the display from ‘Main’ to ‘Switch Setting’. TOTAL SET MULTIPLE MODE GAP 1 REH : 999 PCS/Min :2 :SKIP : 50 PCS CNT :NON STOP TRIM :MANU FILM STOP :ON PUN ULTRASONIC 1:ON :100 m NOW VALUE Pushing of the keypad to select the switch, and pushing to on or off the switch, or to change over Auto/Stop/Manual of the switch. Pushing ‘Main’ key to come back main display. 6.1.1 When ‘Multiple’ is set to ‘1’, the mode is standard. No matter that the mode is ‘Length’ or ‘Multi-sealing’, the function is the same. The display is as below: WORK LENG CNT TOT :1234/Min :1234.12mm : 1234 : 123456 Multiple 1 / 6.1.2 When ‘Multiple’ is set to ‘2’, the mode is set to ‘Multi-sealing’. The display is as below: WORK LENG CNT TOT :1234/Min :1234.12mm : 1234 : 123456 Multiple 2 / \USEBOOK\C\07\7\E\16\A\1\E16A1_E.DOC Multi-sealing Mode: C07-7-E16A1 3 - 8 6.1.3 When ‘Multiple’ is set over than ‘2’, and the mode is set to ‘Length’. The display is as below: WORK LENG CNT TOT :1234/Min :1234.12mm : 1234 : 123456 Multiple 2 / \USEBOOK\C\07\7\E\16\A\1\E16A1_E.DOC Length Mode: C07-7-E16A1 3 - 9 7. Time Setting 7.1 ‘TIME’ key Pushing ‘Time’ key to change the display from ’Main’ to ‘Time setting’. CONVEYOR :5 S CONVERYOR 2 TIME:5 S PUNCH 1 TIME :0.5 S :0.5 S PUNCH 2 TIME DELY WASTE PUN :1 S WASTE PUN TIME :1 S PUN ULTRASONIC 1:1 S Pushing of the keypad to select the switch, and after pushing keypad to set time, pushing ‘ ‘ to confirm. Pushing ‘Main’ key to come back main display. \USEBOOK\C\07\7\E\16\A\1\E16A1_E.DOC Mode: C07-7-E16A1 3 - 10 8. Abnormal Display Abnormal code 01 Machine safeguard error Abnormal information 8.1 Abnormal information and processing program Code Abnormal information MACHINE STRUCTURE 01 GUARD OPEN 05 SERVO & SENSOR 06 GUARD OPEN 08 MEMORY 09 POWER REPEAT How to do 1. PUSH STOP BUTTON TO SHUT OFF ALARM. 2. CLOSE SAFETY GUARD & START MACHINE AGAIN. 1. PUSH STOP BUTTON TO SHUT OFF ALARM. 2. PLEASE ADJUST SERVO RIGIDITY. 3. PLEASE ADJUST THE PHASE 4. IF IT STILL ALARM CONTACT SERVICE. 1. PUSH STOP BUTTON TO SHUT OFF ALARM. 2. CLOSE SAFETY GUARD & START MACHINE AGAIN. 3. PLEASE CHECK THE FUSE OF C09-* AFTER RENEW & START MACHINE AGAIN. 1. SHUT OFF THE POWER THEN TURN IT ON AFTER 5 SECONDS. 2. IF IT STILL ALARM CONTACT SERVICE. NEED AT LEAST 5 SECONDS. \USEBOOK\C\07\7\E\16\A\1\E16A1_E.DOC Mode: C07-7-E16A1 3 - 11 Code How to do Abnormal information OPERATION INNER COMM. INVERTER SYSTEM SERVO SYSTEM 20 BLOCK 21 FILM A 26 PRINT A 29 TEMP. 39 EMERGENCY 40 SVA COMM. 41 SVB COMM. 42 PWM1 COMM. 43 PWM2 COMM. 50 MAIN IV 52 FMB IV 53 FMC IV 54 FMD IV 59 STOP POSITION 61 SVA 62 SVB 1. PUSH STOP BUTTON TO SHUT OFF ALARM. 2. IF THE FEEDING CONDITION IS NORMAL, CHECK THE BLOCK SENSOR IS BROKEN OR NOT. 3. IF THE FEEDING MATERIAL IS JAMMED, CLEAR UP AND SMOOTH THE BAG. 1. PUSH STOP BUTTON TO SHUT OFF ALARM. 2. CHANGE MATERIAL & START MACHINE AGAIN. 1. CHECK POSITION OF PHOTOEYE-ANGLE HEIGHT SENSITIVITY AND CONTRAST POSITION. 2. CHECK LENGTH SETTING.REMEMBER NEED T ADD EXTRA 2mm TO POUCH LENGTH/WIDTH USE FINE ADJUSTMENT BUTTON TO CHANGE LENGTH SETTING. 1. PUSH STOP BUTTON TO SHUT OFF ALARM. 2. CHECK IF THE HEATER IS NORMAL. 3. CHECK IF TEMPERATURE METER IS NORMAL. 1.IF POWER OFF, PRESS “POWER ON” TO OPEN. 2.IF SYSTEM STILL HAS ELECTRIC POWER, PRESS “POWER OFF” TO CLOSE. 1. STOP MACHINE & STOP ALARM. 2. SHUT OFF POWER THEN TURN IT ON AFTER 5 SECONDS. 3. IF IT STILL ALARM CONTACT SERVICE. 1. PUSH STOP TO SHUT OFF ALARM. 2. CHECK MAIN MOTOR INVERTER DISPLAY FOR ERROR CODE AND THEN REFER TO INVERTER MANUAL. 1.PUSH STOP TO SHUT OFF ALARM. 2.CHECK IF CAM IS LOOSE OR DAMAGED AND IS NOT CONTACTING PROXIMITY SWITCH. 3.CHECK IF PROXIMITY SWITCH IS FUNCTIONING PROPERLY. 1.PRESS "STOP" TO TURN OFF ABNORMAL SCREEN ALARM AFTER STOPPING M/C. 2.CHECK CONNECTING WIRE FROM "SERVO" DRIVER TO MOTOR 3.CHECK CONNECTING WIRE FROM "SERVO" DRIVER TO C07-7* 4.PLEASE RECORD ABNORMAL MESSAGE FROM ANY ABNORMAL "SERVO" DRIVER 5.REFER TO "ABNORMAL MESSAGE" FROM " MANUAL" \USEBOOK\C\07\7\E\16\A\1\E16A1_E.DOC Mode: C07-7-E16A1 3 - 12