Transcript
C21A (12V12AH)
BATTERY
Specification Nomial Voltage
12V
Nomial Capacity (20HR)
12AH
Dimension
Length Width Container Height Total Height (with Terminal)
151+ -1mm (5.95 inches) 98 + -1mm (2.56 inches) 95 + -1mm (3.72 inches) 101+ -1mm (3.94 inches)
T1 / T2
Container Material
ABS
UL R
LISTED NATIONAL BATTER Y
0
180A (5s)
Internal Resistance
Approx 17mΩ
Operating Temp. Range
Discharge : -15~50 C (5~122 F) 0 0 Charge : 0~40 C (32~104 F) 0 0 Storage : -15~40 C (5~104 F)
Nominal Operating Temp. Range
0 0 25+ - 5 F) - 3 C (77+
0
Initial Charging Current less than 3.6A. Voltage 14.4V~15.0V at 250C (770F) Temp. Coefficient -30mV/0C No limit on Initial Charging Current Voltage
Electric wheelchairs, scooters, bikes
Emergency first responder equipment Emergency lighting Medical devices Electric carts Telecom equipment Switchgear Solar power systems
13.5V~13.8V at 250C (770F) Temp. Coefficient -20mV/0C o
Self Discharge
Uninterruptible Power Supply (UPS)
Alarm and security systems 0
Capacity affected by Temperature
Applications
Electronic apparatus and equipment
Max. Discharge Current
Standby Use
Non-spillable BATTERY MUST BE RECYCLE D
0
(20hr,1.80V/cell,25 C/77 F) 0 0 (10hr,1.80V/cell,25 C/77 F) 0 (5hr,1.75V/cell,25 C/770F) (3hr,1.75V/cell,250C/770F) (1hr,1.60V/cell,250C/770F)
Rated Capacity
Cycle Use
C21 A (12V 12A H)
Sea led Lea
d-ac id Batt ery CON STAN T VOL TAG E CHA RGE Stand by use: 13.5 -13.8 Cycle V use: 14.4- 15.0 Initia l curre nt: V Less than 2.1 A
Warning : Risk of fire, explosio n, or burns. heat above the 50 O C, or incinera Do not disasse mble, te.
3.56 kg (7.85 lbs)
Approximate Weight Terminal
BATTER Y
Main tena nce -free
o
40 C (104 F) 103% o o 100% 25 C (77 F) o o 86% 0C (32 F) National Battery batteries may be stored for up to 1 year at 250C (770F) and then a freshening charge is recommended For higher temperatures the time interval will be shorter.
Constant Current Discharge (Amperes) at 25 0C (77 0F)
Constant Power Discharge (Watts) at 25 0C (77 0F)
UL R
LISTED
Dimensions T1 Terminal
101+ -1 95+ -1
BATTERY
98+ -1 78+ -1
6.35 (0.25)
Unit: mm ( inches )
C21A (12V12AH)
Maintenance-free Sealed Lead-acid Battery CONSTANT VOLTAGE CHARGE Standby use: 13.5-13.8 V Cycle use: 14.4-15.0 V Initial current: Less than 2.1 A
7.95 (0.313)
0.8 (0.031)
Warning: Risk of fire, explosion, or burns. Do not disassemble, heat above the 50 O C, or incinerate.
3.4 (0.134)
UL R
LISTED
Non-spillable BATTERY MUST BE RECYCLED
NATIONAL BATTERY
151+ -1
Discharge Characteristics
Float Charging Characteristics
12V 6V 4V 2V Battery Battery Battery Battery ЈVЈ ЈVЈ ЈVЈ ЈVЈ
13.0
6.5
4.33
0
Charge Charging Charging Volume Current Voltage
0
Temperature : 25 C ( 77 F)
2.16
(XCA)
%
Terminal Voltage (V)
12.0
11.0
6.0
5.5
4.00
3.66
2.00
120 110 100
1.84
0.093C 0.05C
90 80
0.207C 10.0
5.0
3.33
1.68
9.0
4.5
3.00
1.52
0.4C
8.0
4.0
2.67
50 40 30 20
1.36
3C 1
2
4
2C
6 8 10
40 60
20
2
4
6 8 10
Min
H
15.0
7.5
14.0
7.0
2.33 Charge Voltage (Constant 2.25v/cell)
0.15 13.0
2.17
6.5
After 50% Discharge
0.10
12.0
6.0
0.05
11.0
5.5
2.00
After 100% Discharge 1.83
Charging Current 0 0
4
8
16
12
20
32
28
24
36
40
Charging Time (hours)
Effect of Temperature on Long Term Float Life
Temperature Effects in Relation to Batter Capacity
10
120
8 6 5 4
80
Life expectancy (year)
A 0 .0 5 C A 0 .1 C
100
Capacity Ј%Ј
2.50
Charged Volume
Discharge Time
0 .2 C A
60
1 .0 C A
40
2 .0 C
20 0 -20
A
3. 0C A
Charging voltage : 2.25V/cell
3 2
1
0.5
-10
0
10
20
30
40
50
30 86
20 68
0
Temperature ( C)
80
200
400
800
1000
C
20 0
30% DOD
600
300C
400C
40
2
4
6
8
10
12
Storage Time (Months)
Ambient Termperature: o o 25 C (77 F)
0 0
B
60
60
20
A
250C
Remaining Capacity (%)
100
50% DOD
100C
80
Ambient teperature:25±5 C
100% DOD
C F
0
100
0
40
0
Self Discharge Characteristics
Testing condition Discharging: current 0.17C (FV 1.7V/cell); Charging: current 0.25C max, voltage 2.45V/cell; Charging volume : 125% of discharged capacity.
120
50 122
40 104
Battery temperature
Cycle Life in Relation to Depth of Discharge
Capcity (%)
(V)
0.20
10 0
20
temperature 250C
0.25
70 60
0.628C
1C
Charging Voltage 0.10CA-2.25V/cell
(V)
(V)
A
No supplementary charge required (Carry out supplementary charge before use if 100% capacity is required.)
B
Supplementary charge required before use.Optional charging way as below: 1. Charged for above 3 days at limted current 0.25CA and constant volatge 2.25V/cell. 2. Charged for above 20 hours at limted current 0.25CA and constant volatge 2.45V/cell. 3. Charged for 8~10 hours at limted current 0.05CA .
C
Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this is reached.
1200
Number of Cycles
Contact Information
BATTERY
National Battery 18-32A 127th Street College Point, NY 11356
2
T: (718) 461-9797 F: (718) 425-8994 E:
[email protected]