Preview only show first 10 pages with watermark. For full document please download

C2x In-ground 24v Dimmable Led Fixture Ip68 Remote Driver

   EMBED


Share

Transcript

. Cast stainless steel body 304 alloy . 1W Cree XPE LED . On board electronics for 24V DC and 0-10V Dimming . Unique “bottle cap” threaded lens frame . No screws to lose . Lens frame turned from solid stainless steel . 0.400” thick tempered glass lens . Walkover, drive over rated for 11,000 lbs at 30 mph . Cast stainless steel 304 alloy junction box . Silicone rubber anti siphon outlet box gasket . Remote power supply . Unit can be through wired for daisy chaining . Class II, not suitable for fountain or pool use. . Requires remote 24V Dc power supply . Available in RGB with remote DMX controller listed wet label IP68 C2X In-Ground 24V Dimmable LED Fixture IP68 Remote Driver Series C2X Lamp L-LED Wattage Body 1L-1x1W 3000K LED 4-Fully recessed 2L-1x1W 4000K LED w/cond. entries 4L-1x3W 3000K LED 5L-1x3W 4000K LED Note: Other colors available on request Finish SS-Stainless Steel Optic 0- None 1- 10 Degree Narrow 2- 21 Degree Medium 3- 39 Degree Wide 4- 10x44 Degree Elliptical Note: LED Optics are for use with 'T' clear glass lens. They are not intended for 'K' or 'G' Lenes Ballast X-Remote 24vDC Transformer Required Lens T-Clear Temp Glass K-Internally Ceramic Coated G-Frosted Tempered Glass Options 0-None Note: On board 0-10v Dimming Power Supplies C2X 1 LED/UNIT PPLT00155 120VAC-24VDC 30W PPLT00157 120VAC-24VDC 60W PPLT00158 120VAC-24VDC 100W Designplan Lighting 1W 24vDC w/ integral 0-10v dim 3w 24vDC w/ integral 0-10v dim 1W 24vDC w/ integral 0-10v dim 3w 24vDC w/ integral 0-10v dim 1W 24vDC w/ integral 0-10v dim 3w 24vDC w/ integral 0-10v dim 1 to 10 1 to 6 1 to 19 1 to 13 1 to 32 1 to 22 parallel parallel parallel parallel parallel parallel Drawings C2X Designplan Lighting General Installation Instructions 11/2/07 FAILURE TO FOLLOW THESE INSTRUCTIONS WILL VOID WARRANTY RISK OF ELECTRICAL SHOCK. THIS EQUIPMENT IS TO BE INSTALLED BY A QUALIFIED ELECTRICIAN ONLY. MAKE CERTAIN ELECTRICAL SUPPLY CIRCUIT IS DE-ENERGIZED BEFORE BEGINNING INSTALLATION. CHECK FIXTURE LABEL FOR CORRECT VOLTAGE. READ ALL INSTRUCTIONS CAREFULLY. LOCATION This model is designed for concrete pour installation. The upper edge of the housing must be flush with the prepared surface into which it is recessed. Do not install fixture in a manner that creates a pocket where water can sit on top of fixture. Not suitable for use in places where the luminaire is likely to be exposed to a horizontal stress load caused by braking, acceleration or change of direction. INSTALLATION 1. Lighting fixture comes fully assembled. Note: When not working on fixture replace trim ring for site safety and to protect fixture components from moisture and damage. Keep each trim ring with the original body it was supplied on. Note: Use care to protect O-ring on trim ring. Do not remove, loosen, cut, deform or otherwise disturb O -ring. Keep Oring clean and dry. 2. Set fixture in desired location. Position the fixture in such a manner that the conduit/cable is not stressed at the entry point to the light fixture. 3. The foundation on which the luminaire is to be installed must correspond to the maximum permissible pressure load of the luminaire. Suitable drainage must also be provided. Level the body in two horizontal planes using the three leveling tabs around outer body. The upper edge of the housing must be flush with the prepared surface into which it is recessed. UNDER NO CIRCUMSTANCES MAY IT BE LOWER! 4. Unthread lens assembly from body with tool provided. Ensure that all internal surfaces of the fixture are kept completely dry during installation. Pry out the accessory gasket by using a screw driver. Carefully by hand remove reflector. 5. Connect incoming leads to quick disconnect plug. GREEN WIRE TO “GROUND”, CONNECT BLACK FIXTURE TO BLACK BUIDLING WIRE AND CONNECT WHITE FIXTURE WIRE TO WHITE BUILDING WIRE. Replace tray, lamp, and reflector. Make sure that no wires have been damaged. 6. If using conduit entries, the entries must be sealed with “Dap Heavy Duty Kwik Foam” (not provided). The foam should be sprayed from inside the fixture up into the conduit. Failure by the contractor to use the DAP product could cause a void in the warranty. Replace tray with lamping. If not using through wiring, plug second conduit entry with 3/4" conduit plug. Please make sure wet label requirements are meet. 7. Install lamp and adjust if necessary. Tighten all screws to assure the lamp will not shift after aiming is acquired. Replace reflector and accessory gasket. 8. Place lens frame over fixture ensuring that there is no foreign matter between the lens frame and the body. Start the lamp and bring luminaire to operating temperature (20 to 30min.), this will evaporate the moisture content of air to be trapped. Once operating temperature has been reached, carefully thread the trim assembly to body with tool provided. DESIGNPLAN LIGHTING, INC., 79 TRENTON AVE, FRENCHTOWN, NJ 08825 T. 908-996-7710 F. 908-996-7042 79 Trenton Avenue Frenchtown, NJ 08825 www.designplan.com Tel: (908) 996-7710 Fax: (908) 996-7042