THANK YOU Thank you for purchasing the C5MM1 Series Universal Mount. Please read these instructions thoroughly before installing this product. PRODUCT FEATURES - Safely and easily mounts large format monitors to C5 Credenza Rack - Proprietary extruded uprights for a sleek appearance - Structural members made from heavy-duty 11 gauge steel - Fully adjustable in height, with laser cut increments for precise adjustment - Cable management clips included
I-00683
Rev A
IMPORTANT SAFETY INSTRUCTIONS !
WARNING: A WARNING ALERTS YOU TO A SITUATION THAT COULD RESULT IN SERIOUS PERSONAL INJURY OR DEATH.
!
CAUTION: A CAUTION ALERTS YOU TO A SITUATION THAT MAY RESULT IN MINOR PERSONAL INJURY OR DAMAGE TO THE PRODUCT AND / OR PROPERTY. NOTE: A NOTE is used to highlight procedures pertaining to the installation, operation or maintenance of the product.
IMPORTANT WARNINGS AND CAUTIONS!
!
!
WARNING! ANTI-TIP FEET MUST BE INSTALLED FAILURE TO DO SO COULD RESULT IN PROPERTY DAMAGE, SERIOUS PERSONAL INJURY, OR DEATH.
!
CAUTION! SAFETY MEASURES MUST BE PRACTICED AT ALL TIMES DURING THE ASSEMBLY OF THIS PRODUCT. USE PROPER SAFETY EQUIPMENT AND TOOLS FOR THE ASSEMBLY PROCEDURE TO PREVENT PERSONAL INJURY.
!
CAUTION! TO AVOID AN UNSTABLE CONDITION, MONITORS MUST BE CENTERED ON THE HORIZONTAL MONITOR MOUNTING BRACKET.
!
WARNING! THE WEIGHT RATINGS OF THIS PRODUCT CAN BE FOUND ON THE PRODUCT. EXCEEDING THESE WEIGHT RATINGS CAN RESULT IN SERIOUS INJURY OR DAMAGE TO THE EQUIPMENT. IT IS THE RESPONSIBILITY OF THE INSTALLER/USER TO ENSURE THE COMPONENTS INSTALLED ON THIS MONITOR MOUNT DO NOT SURPASS THE WEIGHT RATINGS AS AN UNSTABLE CONDITION CAN OCCUR WHICH MAY CAUSE POSSIBLE INJURY OR DAMAGE.
WARNING! FAILURE TO READ, UNDERSTAND AND FOLLOW THE FOLLOWING INFORMATION CAN RESULT IN SERIOUS PERSONAL INJURY, DAMAGE TO THE EQUIPMENT OR VOIDING OF THE WARRANTY. IT IS THE RESPONSIBILITY OF THE INSTALLER/USER TO ENSURE THAT THIS PRODUCT IS LOADED ACCORDING TO SPECIFICATIONS.
MAXIMUM FLAT-PANEL WEIGHT LIMIT WEIGHT RATING
DETAILS
C5MM1-80S (42” to 80” single monitors)
225 lbs.
C5MM1-55D (42” to 55” dual monitors)
160 lbs. each (320 lbs. total)
C5MM1-70D (56” to 70” dual monitors)
160 lbs. each (320 lbs. total)
TOOLS REQUIRED • #2 Phillips Screwdriver • 1/4” Allen Wrench • Protective Eyewear • Adjustable Wrench • Torque Wrench • 5/16” Wrench Columns (Qty 2) and Shoulder Bolt Plates (Pre-Installed) (Qty 2)
HARDWARE/ITEMS SUPPLIED NOTE: Additional hardware may be included.
1/4”-20 Set Screws (Qty 4)
1/4”-20 Flange Nuts (Qty 2) (Tighten to 76 in-lbs)
1/4”-20 Machine Screws (Qty 2) (Tighten to 76 in-lbs)
1/8” Allen Wrench (Qty 1)
Angle Brackets (Qty 2)
1/2”-13 Machine Screws (Qty 2) (Tighten to 500 in-lbs)
End Caps (Qty 2)
Cable Management Clips (Qty 6) Page 2
Vertical Mounting Brackets (Qty 2) and Locking Clips (Pre-Installed) (Qty 2)
HARDWARE/ITEMS SUPPLIED (Continued) M4 x 16
(Qty 8) (Qty 4)
M4 x 25 M5 x 12 M5 x 16
Horizontal Mounting Bracket (Model-Specific) (Qty 1)
Upper Mounting Plates (Qty 2)
M5 x 20
5/16”-18 Machine Bolts (Qty 4) (Tighten to 135 in-lbs)
(Qty 6) (Qty 6) (Qty 4)
M5 x 25
(Qty 8)
M5 x 50 M6 x 12
(Qty 6)
M8 x 20
(Qty 6)
Threaded Pins (Qty 2)
M8 x 35 Anti-Tip Feet (Qty 2)
Universal Washers (Qty 8)
(Qty 6)
M8 x 30
Center Bar Supports (Qty 2) (All Except C5MM1-55D-2XX and C5MM1-80S-2XX)
5/16” Flat Washers (Qty 10)
(Qty 8)
M6 x 20
M8 x 25
#10 x 5/8” Pan Head Phillips Wood Screws (Qty 16)
Thread Depth Indicator (Qty 1)
(Qty 8)
(Qty 6) (Qty 4)
M8 x 70
(Qty 4)
Level (Qty 1)
1/4” Small Nylon Spacers (Qty 6)
1/4” Large Nylon Spacers (Qty 6)
1/2” Small Nylon Spacers (Qty 6)
1/2” Large Nylon Spacers (Qty 12)
1” Nylon Spacers (Qty 6)
Nylon Spacers (Qty 4)
#10-32 x 3/8” Thread Forming Screws for Anti-Tip Feet (Qty 8)
Page 3
INSTALLATION 1) Install anti-tip feet using (4) 10-32 x 3/8” thread forming screws as shown (5/16” wrench required). Adjust feet so they touch floor. (FIGURE A, FIGURE B)
Thread Forming Screws (4) 10-32 x 3/8”
2) All Except C5MM1-55D-2XX and C5MM1-80S-2XX: Place (2) center bar supports on credenza, with threaded mounting holes facing rear of credenza. Align with slots as shown. (FIGURE C)
Slot
Center Bar Supports (2)
Center Bar Support
FIGURE A
Threaded Mounting Hole Slot
FIGURE C 3) Secure (2) angle brackets and (2) center bar supports to rear of frame using 1/4”-20 machine screws and 1/4”-20 flange nuts (if not using center bar supports). (FIGURE D) NOTE: Screws must penetrate and be tightly secured to threaded holes in rear of center bar supports.
FIGURE B Machine Screws (1 per bracket) 1/2”-13
Machine Screw (1) 1/4”-20
Top Su rf
ace
FIGURE D Angle Bracket (1) 4) Place top surface on credenza frame, and insert (1) 1/2”-13 machine screw through each corner bracket, into frame and through top surface as shown. (FIGURE E)
NOTE: Hold screws in place to prevent from falling out.
Angle Brackets (2)
Page 4
FIGURE E
INSTALLATION (Continued)
Columns (2)
5) Position upper mounting plates over 1/2”-13 machine screws on Top Surface and secure threaded pins onto machine screws. (FIGURE F)
Threaded Pins (2)
NOTE: Do not fully tighten 6) Secure Top Surface to credenza frame. (Refer to Assembly Instructions for C5 Series Credenza Rack I-00661.)
Top Su rf
ace
7) Place columns over threaded pins (FIGURE F) and rotate columns so that set screw holes face the rear of credenza. Do not tighten. (FIGURE G)
Upper Mounting Plates (2)
FIGURE F Machine Screws (1 per bracket) 1/2”-13
Column
Shoulder Bolts
Horizontal Mounting Bracket
Set Screws (2 per column) 1/4”-20
FIGURE G 8) Hang horizontal mounting bracket by shoulder bolts on columns to determine desired height. (FIGURE H)
Columns
NOTE: Columns are marked in one-inch height increments.
FIGURE H
NOTE: Teardrop shoulder bolt holes indicate the proper orientation of the horizontal mounting bracket.
Teardrop Hole
9) If necessary, remove horizontal mounting bracket and loosen (2) 5/16-18 flat hex head machine screws on shoulder bolt plate to adjust height up and down. (FIGURE I)
Flat Hex Head Machine Screw (2) 5/16”-18
!
TIGHTEN TO 15 FT-LBS
Shoulder Bolt Plate
NOTE: Use provided level to ensure horizontal bracket is level. 10) When desired position is reached, hang horizontal mounting bracket on shoulder bolts. 11) Tighten (2) 5/16-18 flat hex head machine screws to 15 ft-lbs. DO NOT OVERTIGHTEN. (FIGURE I) Page 5
Shoulder Bolt
FIGURE I
INSTALLATION (Continued) 12) Secure horizontal mounting bracket to columns using (4) 5/16”-18 machine bolts. Tighten bolts to 15 ft-lbs. DO NOT OVERTIGHTEN. (FIGURE J)
! Tighten 1/2” -13 machine screws and threaded pins to 40 ft-lbs. Use adjustable wrench on flats of threaded pins. (FIGURE F)
Horizontal Mounting Bracket
13) Tighten set screws (4 places) using 1/8” allen wrench. (FIGURE G)
Machine Bolts (4) 5/16”-18 TIGHTEN TO 15 FT-LBS
FIGURE J
!
Selecting The Mounting Hardware To Attach Brackets To Flat Panel 1) Identify the correct diameter screw for the flat panel threaded inserts. The correct screws should thread easily and not pull out when tension is applied. 2) To determine proper screw length, insert thread depth indicator into a threaded insert on the flat panel. 3) Mark the thread depth indicator 1/8” above the depth of the threaded insert. (FIGURE K) Mark 1/8” Above Depth
4) Select a screw that is shorter than the 1/8” mark made on the thread depth indicator.
!
Threaded Insert Thread Depth Indicator
CAUTION! Do not use any screw longer than the 1/8” mark or damage to the flat panel may occur.
Small Straw or toothpick
Depth Plus 1/8” Allowance Mark
Page 6
Small Straw or toothpick
FIGURE K
Depth Plus 1/8” Mark Allowance
INSTALLATION (Continued)
Dimples (Face Up)
Universal Washers
M8 M6 M5 M4
Universal washers are designed to accommodate the various M4, M5, M6 and M8 hole sizes found in flat panels. NOTES: • Place flat panel on soft, flat surface while working. • Do not place excessive pressure on back of the flat panel. • Universal washers must be installed between the head of the mounting screw and the vertical mounting bracket as shown. (FIGURE L) Nylon Spacers
Mounting Screw Universal Washer
Nylon spacers add distance between vertical mounting bracket and flat panel. They will fit all supplied screw sizes. The spacers must be used only when attaching flat panels which have: • Recessed mount points • Uneven mount points • Any obstruction near the mount points • A curved back
Mounting Bracket
Flat Panel Nylon Spacer Mount Point
NOTES: • Nylon Spacers must be stacked and oriented as shown. • Nylon Spacers must only be installed between the vertical mounting bracket and the flat panel. Attaching Vertical Mounting Brackets to Flat Panel NOTE: Be sure to observe the “up” arrow on each vertical mounting bracket to maintain the proper orientation of the flat panel. (FIGURE M) 1) Place the flat panel face down on a soft, flat surface and identify the number and location of screws.
FIGURE L “Up” Arrow
2) Align the holes on each vertical mounting bracket with the threaded inserts on the flat panel. 3) Secure each vertical mounting bracket with the screws and hardware identified in previous steps. Use a minimum of (2) screws per vertical mounting bracket. FIGURE M Page 7
INSTALLATION (Continued)
Vertical Mounting Bracket
Hanging the Flat Panel NOTE: This section requires two people. Do not release your flat panel until you are certain that the top hook of each vertical mounting bracket is securely seated on the upper rail of the horizontal mounting bracket.
Top Hook
1) Remove locking clips from vertical mounting bracket and rotate locking clamps down. (FIGURE N)
Locking Clamp
2) Raise the flat panel slightly above the top and bottom rails on the horizontal mounting bracket. (FIGURE N)
Bottom Hook
3) Slide the flat panel down slowly, ensuring that the top hook on the vertical mounting bracket properly engages the horizontal mounting bracket. (FIGURE N) 4) Check for proper height. (Remove and adjust height as necessary)
Horizontal Mounting Bracket
5) Rotate locking clamps up and insert locking pins as shown. (FIGURE O)
FIGURE N
6) Snap end caps into the top of both columns. (FIGURE P)
DETAIL
A
FIGURE O FIGURE P 7) Snap cable management clips into columns to secure cabling as needed. (FIGURE P)
Cable Management Clips
Page 8
FIGURE P
WARRANTY Middle Atlantic Products (the "Company") warrants the C5MM1 Series Universal Monitor Mount to be free from defects in material or workmanship under normal use and conditions for the lifetime of the product. The Company's entire liability to the purchaser, and the purchaser's (or any other party's) sole and exclusive remedy, under this warranty shall be limited, at the Company's option, to either (a) return of and refund of the price paid for, or (b) repair or replacement at the Company's factory of the products purchased, or any part or parts thereof, which the Company has determined to be defective after inspection thereof at the Company's factory. This warranty does not cover damage due to acts of God, accident, misuse, abuse or negligence by parties other than the Company, or any modification or alteration of the products. In addition, this warranty does not cover damage due to improper handling, assembly, installation or maintenance. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, IN NO EVENT SHALL THE COMPANY BE LIABLE FOR ANY SPECIAL, INCIDENTAL, INDIRECT, OR CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION OR ANY OTHER PECUNIARY LOSS) ARISING OUT OF THE USE OF THE PRODUCTS PURCHASED, EVEN IF THE COMPANY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THE COMPANY'S LIABILITY TO THE PURCHASER (OR ANY OTHER PARTY) HEREUNDER, IF ANY, SHALL IN NO EVENT EXCEED THE PURCHASE PRICE OF THE PRODUCTS PAID TO THE COMPANY. Corporate Headquarters Corporate Voice 973-839-1011 - Fax 973-839-1976 / International Voice +1 973-839-8821 - Fax +1 973-839-4982 middleatlantic.com -