Preview only show first 10 pages with watermark. For full document please download

C9 Sub-base Fuel Tank Base Lehe5433-04

   EMBED


Share

Transcript

ATTACHMENTS C9 SUB-BASE FUEL TANK BASE Diesel Generator Set 180-300 kW 60 Hz Image shown may not reflect actual product. FEATURES DESCRIPTION • UL listed for United States (UL 142) and • Dual wall, secondary containment Canada (ULC S601) • Heavy gauge steel construction • Compliant with NFPA 30, 37 & 110 and CSA • Rear and right side stub-up access C282-09 & B139-09 standards. • Emergency vents on primary and secondary • Tank design provides capacity for thermal tanks are sized in accordance with NFPA 30 expansion of fuel • Leak detection switch • Direct reading fuel level gauge • Compatible with enclosures (weather protective • Fuel supply dip tube is positioned so as not and sound attenuated) to pick up fuel sediment • The sub-base fuel tank mounts below the • Fuel return and supply dip tubes are • generator set wide base separated by an internal baffle to prevent recirculation of heated return fuel OPTIONS • Fuel fill – 101.6 mm (4 in), lockable flip top cap • Manual fuel transfer pump • Primary tank level detection switch in • Low fuel level switch (alarm and shutdown) containment basin • Primary and secondary tanks are leak tested at 20.7 kPa (3 psi) minimum • Welded steel containment basin (minimum of 110% of primary tank capacity) • Interior tank surfaces coated with a solventbased thin-film rust preventative • Heavy gauge steel gussets suitable for lifting package • Gloss black polyester alkyd acrylic enamel exterior paint over epoxy based primer • Primary tanks are equipped with customer connections for remote fuel transfer, return and vent LEHE5433-04 ATTACHMENTS C9 FUEL TANK BASE (SUB-BASE) USEABLE CAPACITIES Fuel Tank Dimensions DUAL WALL SUB-BASE – WIDTH 1140 mm (44.9 in) OPEN SET & WEATHER PROTECTIVE ENCLOSURE Liter 2500 2690 Gallon 600 710 Feature Code FTBDW1D FTBDW65 Type Sub-Base Sub-Base W eight kg lb 1109 2,444 1128 2,486 Tank Only Height ' A' mm in 1100 43.3 1100 43.3 Length ' B' mm in 4205 165.6 4205 165.6 Tank and Package Open PGS Height Enc. PGS Height* mm in mm in 2962 116.20 3263 128.5 2962 116.20 3263 128.5 Length ' B' mm in 4205 165.6 4205 165.6 Tank and Package Open PGS Height Enc. PGS Height mm in mm in NA NA 2810 110.6 NA NA 2810 110.6 *Enclosure Package Height includes muffler DUAL WALL SUB-BASE – WIDTH 1140 mm (44.9 in) SOUND ATTENUATED ENCLOSURE Liter 2500 2690 Gallon 600 710 Feature Code FTBDW64 FTBDW65 Type Sub-Base Sub-Base W eight kg lb 1109 2,444 1128 2,486 Tank Only Height ' A' mm in 1100 43.3 1100 43.3 The heights listed above do not include lumber used during manufacturing and shipping. Tanks with full electrical stub-up area include removable end channel. Tanks with RH/LH stub-up include stub-up area directly below the circuit breaker or power terminal strips. Dual wall sub-base tanks are UL listed and constructed in accordance with Underwriters Laboratories Standard UL142 "Steel Aboveground Tanks for Flammable and Combustible Liquids" and Canada ULC S601 “Shop Fabricated Steel Aboveground Tanks for Flammable and Combustible Liquids.” Fuel tanks comply with the following United States NFPA Codes: NFPA 30 – Flammable and Combustible Liquids Code NFPA 37 – Standard for Installation and Use of Stationary Combustible Engine NFPA 110 – Standard for Emergency and Standby Power Systems Fuel tanks comply with the following Canadian Codes: CSA C282-09 – Emergency Electrical Power Supply for Buildings CSA B139-09 – Installation Code for Oil-Burning Equipment Information contained in this publication may be considered confidential. Discretion is recommended when distributing. Materials and specifications are subject to change without notice. CAT, CATERPILLAR, their respective logos, “Caterpillar Yellow,” the “Power Edge” trade dress as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission. www.Cat-ElectricPower.com LEHE5433-04 (08-11) ©2011 Caterpillar All rights reserved