Preview only show first 10 pages with watermark. For full document please download

Cab 100™ & Cab 200™ The Smarter Alternative To Conventional Batteries.

   EMBED


Share

Transcript

CAB 100™ & CAB 200™ 100kW & 200kW Compressed Air Batteries The smarter alternative to conventional batteries. For DATA CENTRES and other large UPS applications The Compressed Air Battery scroll expander generates standby power instantly from compressed air direct to the DC bus of a new or existing UPS ELECTRICITY OUT AIR IN Valve benefits • • • • • low initial and whole life costs low maintenance consistent high performance and power availability reliable, even in hostile environments fast plug-and-play installation features • environmentally tolerant, self-contained units • comprehensive GUI status display as standard • run from standard cylinders or plant ring main air supplies • auto compressor option for cylinder recharge • very low environmental impact and disposal issues Scroll Generator Expander FACT Conventional UPS/standby batteries are expensive to maintain and may fail to perform when needed FACT Compressed Air Batteries cost less to operate, are low maintenance and dependable compresssed air batteries, the smarter backup choice CAB 100 & CAB 200 TM TM 100kW & 200kW Compressed Air Batteries power module 1 1 2 2 3 3 1 2 5 Key 3 1 2 4 4 5 3 4 4 5 Front Ultra capacitors Control electronics Scroll generators Exhaust chambers Control pneumatics Side system overview INTEGRATED control electronics Instant response Automatic power/load balancing Detailed GUI as standard shows: Battery status Condition Run time availability Alarms with auto recharge compressor STANDARD user interface with remote PC access Air Cylinders -------- OUT IN -------DC OUTPUT Or compressed air mains UNIQUE electro-pneumatic controller RELIABLE scroll expander PERMANENT MAGNET servo generator Regulates air electronically Delivers instant start up Seamlessly matches output with load Low inertia PLUS high torque Instantly adapts to load Robust & maintenance-free Low inertia design Instantly adapts to load Robust & maintenance-free ~ ~ ~ CONTROLLER DC OUTPUT AC OUTPUT GRID CONNECTED AC OUTPUT how they work efficient power train Energy is stored in compressed air cylinders and regulated through control valves to rotate the scroll expander. This drives a generator to support the load. instant performance The scroll starts extremely quickly (200 milliseconds) and ultracapacitors are used to bridge the gap between the grid outage and the scroll generator spinning up to speed. business benefits proven reliability Our systems provide dependable service worldwide, in fields including aerospace, electricity networks and telecoms. low lifetime costs (capex/opex) CAB 100™ and 200™ CAPEX costs are competitive – OPEX costs are much lower than for traditional batteries. Minimal maintenance requirements plus very low standby losses add up to exceptionally low whole-life cost of ownership. easy fit scalable solutions Compressed air batteries are modular in design, with capacities of 1kVA to 2MVA and above. fast plug-and-play installation CAB 100™ and 200™ units are delivered to your site, ready to use. weatherproof enclosures Our units are completely self-contained and can be weatherproofed if required. They can be installed virtually anywhere, in any environment. CAB 100TM & CAB 200TM 100kW & 200kW Compressed Air Batteries standard specifications PRODUCT CODE: Technical Output Height/Width/Depth Weight Supply Pressure Run Time (from standard extendable cylinder pack) POWER DC Voltage Voltage regulation DC100/DC200 100kW Height 2200mm (86.6”) x Width 800mm (31.5”) x Depth 800mm (31.5”) 800 kg (1760 lbs) > 35 bar (507.5 psi) 200kW Height 2200mm (86.6”) x Width 800mm (63”) x Depth 800mm (31.5”) 900 kg (1985 lbs) 30 seconds Customer specified: 350-600 Vdc +/- 0.5% ENERGY SOURCE Air quality Recharge type High pressure cylinders or medium pressure plant main Standard industrial Automatic compressor ENVIRONMENTAL Operating temperature Storage temperature Humidity Heat dissipation Noise Enclosure -20 to +40°C (-4 to 104°F) (-40°C/+50°C on request) -40 to +60°C (-40 to 140°F) >95% non-condensing 120W in standby mode 200W in standby mode <70dBA at 5m as standard across range Standard industrial: internal & external options Source INSTRUMENTATION Remote LCD display shows run time remaining and operational status, Touchscreen GUI option Ethernet (TCP-IP), modem, Modbus, BACnet STANDARD Safety Emissions Immunity CE Certified CE Certified CE Certified Local Technical Information & Support Flow battery, Capenhurst Technology Park, Capenhurst, Chester, UK, CH1 6EH t. +44 (0) 151 348 2114 f. +44 (0) 151 348 2101 [email protected]