Cable Fault Location Services With Lira Technology

   EMBED


Share

Transcript

Cable Fault Location Services with LIRA® Technology General approach The objective of Asset Services is to ensure fault-free operations and to minimize the need for fault recovery. That’s also the case for cable grids or connections. If a failure nevertheless occurs, it’s essential to quickly locate cable faults in the most accurate manner possible. Although the cables are highly developed, there are sometimes failures in cable networks. Even properly installed cables can face progressive degradation due to harsh environmental conditions such as overheating, excessive moisture, corrosive environ- ments, mechanical stress and aging of the insulation. To keep the consequential damages as small as possible, we offer trained staff and efficient equipment. Our Cable Fault Location Services performed with LIRA® (LIne Resonance Analysis) Technology will together with other inspection tools provide the grid operator with a wear-free and comprehensive fault location methodology for a fast recovery time. LIRA®can detect: degradations due to temperature, bends, scratches, corrosion, water intrusion, me- chanical impacts, fatigue, water trees, etc. insulation material degradation cable joint positions In case of mechanical impact on cables, LIRA® measurements will be performed also to evaluate the severity of any damage on the cable system. This ensures maximum operational reliability. Of course, all measured data will be stored like a fingerprint for future use e.g. for intro- iduction of condition based maintenance, (CBM), based on regular assessments. The Cable Fault Finding Services are available from our local representatives. Monitoring, Diagnostics and Cable Services Measurement of MV cables Your benefits at a glance ® With LIRA Cable Fault Locations Services the grid operator can minimize the recovery time and establish promptly and effectively the necessary corrective measures. ® LIRA offers fault location with the best accuracy compared with alternative technologies. Degradations can be assessed precisely and by that corrective actions can be planned in advance. ® By that, LIRA can save significant cost for fault recovery due to shorter repair times. Historical cable reports provide an early warning system for potential faults. ® LIRA is a wear-free location methodology with only 5 V white noise. LIRA® has no limitations in cable length. The benefits apply to Transmission & Distribution grids On- and Offshore wind parks Process Industry Oil- and Gas Industry - Topside and submarine cables (incl. umbilical) (Nuclear) Power Plants - I&C and Power cables Cable Manufacturers - Reference measurements - Quality control The LIRA®-Technology ® LIRA is a system for diagnosis and condition based monitoring of installed electric ® cables. LIRA can measure cable length ranges from a less than 50 meters to several hundred kilometers, depending by the cable design and electric attenuation. ® The LIRA technology is a non-destructive test method, and will not damage any part of your cable or any equipment connected to the cable. ® The LIRA technology is based on the transmission line theory, through the estimation and analysis of the complex line impedance as a function of the applied signal frequency. ® LIRA can monitor the global, progressive degradation of the cable insulation, cable stealth and cable conductor caused either by to harsh environment conditions, or mechanical stresses ® LIRA is especially sensitive to small changes in the insulation material, which allows an early indication of challenged areas, detecting and localizing single and multiple faults and their severity. LIRA® measurements are recorded and can be played back and analyzed off-site. Reports in MS-Excel format are automatically generated. The recorded measurements can be stored as reference infor- with repeated measurements. The identification of new damage to the cable can thus be monitored and recorded. The system consists of "off the shelf" hardware plus connection devices and proprietary software performing the failure analysis, degradation analysis and cable simulations. ® LIRA can help to distinguish between different root causes as it is possible to deliver a full condition status and possible fault type and location with better accuracy then other methods. Feature Best-in-class cable diagnostic system. Sensitive to small degradation and defects. Accurate hot-spot and deviation locations. Non intrusive and non destructive. Applicable on multi-segment systems with different cable types. Pre-study/simulation of cable data and defects. ® LIRA performs a power spectrum analysis of impedance phase and amplitude – an advanced detection method of abnormal conditions. Fast and simple connection to test object. Only one access point needed for measuring. ® LIRA provides possibility to zoom in on blind zone at the near end termination. This feature enables detailed, high resolution measurements in the cable end close to the connection point. For all voltage levels from control cables to high voltage cables. Main data and applications Measuring range - From less than 50m to several 100km Frequency rage - 0 to 100MHz Voltage Level - 5Vpp, white noise Operating Mode - Acquire data - Simulate cable data and defects - Playback data for post-analysis Accuracy - Better than 0.5% of cable length Cable types - I&C cables - Low & medium voltage - High voltage AC/DC - Single and multiple conductors Insulation types - PE, XLPE, PVC, PILC, EPR - Hypalon, Lipalon and more . Published by and copyright © 2012: Siemens AG Infrastructure & Cities Sector Smart Grid Division Services Humboldstrasse 59 90459 Nuremberg, Germany www.siemens.com/infrastructure-cities For more information, please contact our Customer Support Center. Phone: +49 (180) 5 24 8437* +49 (180) 5 CITIES* Fax: +49 180 524 24 71 (*Charges depending on provider) E-mail: [email protected] www.siemens.com/infrastructure-cities Smart Grid Division Order No. AS_FF_en_Cable Fault LocationLIRA_1202 Printed in Germany Printed on elementary chlorine-free bleached paper. LIRA® Registered trademark, Pantent pending, owned by Wirescan AS. All rights reserved. Trademarks mentioned in this document are the property of Siemens AG, its affiliates, or their respective owners. Subject to change without prior notice. The information in this document contains general descriptions of the technical options available, which may not apply in all cases. The required technical options should therefore be specified in the contract.