Preview only show first 10 pages with watermark. For full document please download

Cablemaster™800

   EMBED


Share

Transcript

CableMaster™800 For Electrical & Plumbing Contractors Gas Technology Systems Depth of Drive adjustment Compact & Lightweight Design Removable 20 Pin Magazine (50 Pin Magazine Available) Electronic Fuel Injection Lithium Battery Battery & Fuel Gauge Description The RamsetTM CableMasterTM800 is the most technologically advanced gas tool on the market. The new CableMasterTM800 offers a number of innovative features allowing quicker, safer installation of a wide variety of clips for plumbing, data and electrical installations. The speed at which the CableMasterTM800 is able to perform installations provides tremendous savings in total installed cost. Specifications Weight Height Length Magazine Capacity 3.8kg 309mm 396mm 20 (+3) pin magazine, [50 (+3) pin magazine accessory] 82J 5kg 4mm 2 pins per second 750 pins (approx) 3,000 pins (approx) 3.7V Lithium-Ion 90mins (25mins for 500 fixings) Automatic -5°C to 49°C Impact Force Actuation Pressure Overdrive Intermittent Operation Fuel Cell Life Battery Charge Capacity Battery Voltage Battery Charge time Power Regulation Operating Temperature Range Substrates Concrete, Composite Steel Decking, Solid Brick, Precast Concrete, Steel Pre-stressed Concrete, Hollow Block Wall, Reinforced Concrete, Reinforced Prefabricated Concrete Related Products Drive Pins & Fuel Cells Contractor Packs 12 12 www.ramset.com.au www.ramset.com.au 1300 780 063 1300 780 063 Features & Benefits • Battery Gauge – Helps avoid running out of battery power. • Fuel Cell Gauge – Always know when to change fuel cells. • Lithium Battery – Fast Charge, Long Life • Tool-less Depth of Drive Adjustment • Power Saving Technology – isolates battery when tool is not in use • Compact design with 20 pin magazine – Allows the tool to fit in tight spaces • Easily removable fastener guide and magazine • Greater tool clearance – Allows the tool to fit in close to edge applications. • Removable Support Leg – Ensures tool is at 90° to work surface for optimum fixings • Electronically controlled fuel injection – Ensures consistent power in a wide temperature range. • Low Maintenance. Designed to work in all Australian conditions. CableMaster™800 For Electrical & Plumbing Contractors Trades & Applications Plumbing Electrical Contractor Contractor Permanent cable suspension to concrete and steel 4 Pipe suspension systems to concrete and steel 4 Fire and security cabling to concrete and steel Temporary cable suspension to concrete and steel 4 Fire & Security 4 Gas Technology Systems Standard Operating Procedure Always read and understand the instruction manual before attempting to operate a Ramset™ Gas Technology Tool. 1. First insert the fuel cell and battery into the tool. 2. Insert the collated fasteners into the magazine. 3. The clip should then be placed on the end of the fastener guide without compressing the front end of the tool. 4. The tool should then be compressed against the work surface. (Making sure that the tool is perpendicular to the work surface). 5. Once the tool is compressed the trigger can be actuated and the fastener is driven into the substrate securing the clip in place. CableMaster™ 800 Part No Description CABLEMASTER 800 CableMaster™ 800 Pulsa™ Gas Tool + 2 x Lithium-Ion Batteries Order Qty 1 Kit includes: CableMaster™ 800™ tool, high impact carry case, 2 x batteries, battery charger, safety glasses and instruction manual Accessories Part No 018543 018544 018545 018546 014641 018423 018424 B20544L PA1613 CS42025 Description Pulsa 800 20 Pin Magazine Pulsa 800 50 Pin Magazine Pulsa 800 Lithium-ion Battery Pulsa 800 Lithium-ion Battery Charger Pulsa 800 Magnetic Washer Adaptor CableMasterTM800 Fastener Guide TrakFastTM800 Fastener Guide Gas Tool Degreaser and Lubricant Safety Glasses Saddle Adaptor 20/25mm Order Qty 1 1 1 1 1 1 1 1 1 1 www.ramset.com.au www.ramset.com.au 1300 780 063 1300 780 063 13 13 CableMaster™ Consumables Heavy Duty Pin Range for Steel and Hard Concrete Fixing Gas Technology Systems Drive Pins designed for fastening to standard strength concrete, masonry and steel. Specifications Raw Material Corrosion Protection Nominal Head Diameter Nominal Shank Diameter Shear Strength Tensile Strength Hardness Pulsa 800 Part No P8HC615 P8HC617 P8HC622 Carbon Steel Zinc Electroplated (Minimum coating 5µm) 6.3mm 2.6mm (C620 Stepped shank 2.6/2.2mm) 1120N/mm2 1800N/mm2 52-56HRC Original Pulsa 700 Part No HC615 HC617 HC622 Description Length Order Qty Heavy Duty Steel/Concrete Premium Hard Concrete/Steel Premium Hard Concrete/Steel 15mm 17mm 22mm 500 500 500 10 strip collation (suitable for use in 40 and 50 pin magazines) + 1 x Fuel Cell Soft Washered Pin Range for Steel and Hard Concrete Fixing The Soft Washered pin range is designed for use with pre-drilled PVC fittings where the pre-drilled hole size is between 3.0 to 8.0mm in diameter. These pins are used to securely fasten a variety of PVC fittings to concrete. They are used in a single shot format and are not suitable for use with a magazine. Specifications Raw Material Corrosion Protection Nominal Head Diameter Nominal Shank Diameter Shear Strength Tensile Strength Hardness Nominal Washer Diameter Part No CG620 Carbon Steel Zinc Electroplated (Minimum coating 5µm) 6.3mm 2.6mm 1120N/mm2 1800N/mm2 52-56HRC 11.0mm Description Soft Washered Pin Length 20mm 10 strip collation + 1 x Fuel Cell Ramset™ recommends application test on-site before commencing use. 14 www.ramset.com.au 1300 780 063 Order Qty 500 CableMaster™ Consumable Selection Guide Strap, Plates & Fixtures Data Cable 4 4 DataLec™ Clip 4 4 4 4 4 4 4 4 4 4 4 CTClip™ 4 EClip™ 4 4 4 4 Threaded Rod Hanger 4 4 4 FP FireFix™ Clip 4 4 4 4 CableHorn™ Double & Single Electrical Conduit 4 4 4 Cable Fixing ClipElec™ 4 4 CableMaster™ Consumables 4 Direct Alignment Half Saddle Strap & Plate Mounting Washer Catenary Wire Bracket 4 4 Gas Technology Systems Light Duty Cable Tray Flexible/Plastic Pipe Catenary Wire Metal Pipes Metal/Nylon Straps Fire & Service Cabling Small Diameter Rigid Pipes Application Type 4 4 4 4 Recommended Ramset™ recommends application test on-site before commencing use. www.ramset.com.au 1300 780 063 15 ClipElec™ CableMaster™ Consumables Description Gas Technology Systems ClipElec™ is an all purpose cable tie system that may be used for fixing cable, conduit and pipes for a wide variety of electrical and plumbing applications. This system is extremely versatile allowing for many different sized cables, pipes and conduit to be secured. The ClipElec™ all purpose cable tie system may be used with the 4.8mm supplied cable ties or with other cable ties up to a maximum width of 9mm. Specifications Polypropylene copolymer, high impact, halogen free. UV resistant Up to 9mm cable tie width. 0.5 & 1 metre (approx) Incandescent wire test (regulation NFC 20-455) 750°C passed - LCIE laboratory test results N° 438 309 (December 1998) No breakage at 0°C 32 x 37mm Raw Material Capacity Spacing Recommendation Fire Resistance Properties Low Temperature Test Dimensions Pin Selection Guide Substrate Hard Concrete >50MPa Concrete <50MPa Hollow Concrete Block Steel Steel Decking 4 Suitable k Possible Features & Benefits • ClipElec™ can be used for cable, conduit and tube work. • Universal design allows cable ties up to 9mm wide. • Designed with an in-built energy absorber for perfect embedment. • Clips directly onto the CableMaster™ Pin Guide for one handed operation. • Hands are a safe distance from the Pin Guide during installation. • Can be used with the PulsaLift™ Pole to fix from the ground. • Optional plug and screw installation. Performance Table* HC617 4 4 k 4 4 HC622 4 4 4 4 4 Pin HC617 HC622 C620 Load Capacity (Tension) - Concrete Cable Tie Width 20MPa 32MPa 9mm 10kg 12kg 9mm 10kg 12kg 4.8mm 2.5kg 3.7kg Installation Procedure 1. Simply clip the ClipElec to the tool pin guide. 2. Press against the substrate, press the trigger & the clip is fixed. 3. Install the tube or conduit with cable tie. ClipElec™ All-purpose Cable Tie Clips Pulsa 800 Part No Original Pulsa 700 Part No P8CPGCL CPGCL P8CPGCLHC617 CPGCLHC617 Description ClipElec™ Contractor Pack (500 x clips, HC622 Pins, Fuel Cell, Cable Ties 200mm x 4.8mm Black) ClipElec™ Hard Concrete Contractor Pack (500 x clips, HC617 Pins, Fuel Cell, Cable Ties 200mm x 4.8mm Black) Order Qty 1 1 *NOTE: Test concluded when clip pulled over pin head or cable tie failed. Job-site testing may be required to determine actual achievable job-site values. Results have been achieved with a CableMaster™ tool set at minimum overdrive setting. Accessories failing to fix correctly should be removed and a new fixing set away from any spalled concrete. Tension loads provided are for static load situations only. Values represent a minimum factor of safety of 3:1 on the lowest test results achieved. Minimum edge distance 75mm, minimum spacing between fixings 50mm. Tension loads are per fixing, however a minimum of 3 fixings per fastening unit should be used. Ramset™ recommends application test on-site before commencing use. 16 www.ramset.com.au 1300 780 063 CTClip™ CableMaster™ Consumables Description The CTClip™ is the all in one cable tie system. With the integral cable tie the CTClip™ can be used for cable, conduit and tube work. Gas Technology Systems Specifications Raw Material Spacing Recommendation Fire Resistance Properties High impact, Nylon 66 0.5 & 1 metre (approx) UL94HB Fire Test Features & Benefits • CTClip can be used for cable, conduit and tube work. • Maximum cable cluster or tube diameter of 63mm. • Clip base raised above work surface. • In-built energy absorber for optimum pin penetration. • Side mount clip into pin guide. • One handed installation. • Fix from the ground with the PulsaLift™ Pole. • Optional plug and screw installation. Pin Selection Guide Substrate Hard Concrete >50MPa Concrete <50MPa Hollow Concrete Block Steel Steel Decking 4 Suitable k Possible HC617 4 4 k 4 4 HC622 4 4 4 4 4 Performance Table* Load Capacity (Tension) - Concrete 20MPa 32MPa 7kg 9kg 7kg 10kg Pin HC617 HC622 Installation Procedure 1. Side mount clip into pin guide. 2. Press against work surface. Fire tool. 3. Install the cable or conduit/tube as required. Fasten tie strap. CTClip™ Pulsa 800 Original Pulsa 700 Part No Part No P8CPGCT CPGCT Description CTClip™ Contractor Pack Standard (500 x clips, HC622 Pins, Fuel Cell) Pipe / Conduit Diameter Order Qty 16 - 32mm 1 *NOTE: Test concluded when clip pulled over pin head or cable tie failed. Job-site testing may be required to determine actual achievable job-site values. Results have been achieved with a CableMaster™ tool set at minimum overdrive setting. Accessories failing to fix correctly should be removed and a new fixing set away from any spalled concrete. Tension loads provided are for static load situations only. Values represent a minimum factor of safety of 3:1 on the lowest test results achieved. Minimum edge distance 75mm, minimum spacing between fixings 50mm. Tension loads are per fixing, however a minimum of 3 fixings per fastening unit should be used. Ramset™ recommends application test on-site before commencing use. www.ramset.com.au 1300 780 063 17 DataLec™Clip Multi-purpose Data & Cable Clip Gas Technology Systems Description DataLec™ Clip is a Multipurpose data and cable clip for the fast installation of specialised and standard cables. Install Fibre Optic, Broadband, Cat5/6, Audio visual and other specialised cables using soft Velcro® style straps to correctly support and secure these cables without damage. For standard electrical and power cabling installations hard plastic cable ties or soft Velcro® style straps can be used to suit installation needs. This versatile and strong clip design is suitable for the installation of multiple cable bundles, multi-directional cable runs, small diameter conduits with cables and plastic/ metal pipes. Features & Benefits Specifications HDPE, High impact ,Halogen free 14mm wide from 0.3 to 1mtr (approx.) depending on application 33W x33D x 14H Raw Material Slot opening Clip spacing recommendation Dimensions (mm) Pin Selection Guide Substrate Hard Concrete >50MPa Concrete <50MPa Hollow Concrete Block Steel Steel Decking 4 Suitable k Possible HC617 4 4 k 4 4 • One clip for data and standard cable installations • Multiple cable mounting positions • Wide soft Velcro® style strap (12mm) or hard plastic tie compatible • Parallel or multi-directional cable fixing • Single and cable bundle installations • Non abrasive support and protection of services • Suits cable in conduit and small diameter pipe applications • Fix to standard and hard concrete, hollow masonry block & steel formwork Performance Table* HC622 4 4 4 4 4 Total tensile load capacity per DataLecTMClip - HC617 or HC622 Pins Concrete compressive strength Width 20MPa 40MPa Cable Tie (supplied) 4.8mm 5kg 7kg Cable Tie1 7.6mm 12kg 15kg VELCRO strap2 12mm 3kg 4kg Installation Procedure 1. Gently insert clip mounting tip (centre of clip) into CableMaster™ tool nosepiece 2. Press clip against substrate, depress CableMaster™ tool nosepiece and fix clip 3. Attach cable to DataLec™ clip with appropriate tie or strap for the application Datalec™ Multi-purpose Data & Cable clips Pulsa 800 Part No Original Pulsa Description 700 Part No P8CPGDLHC617 CPGDLHC617 P8CPGDLHC622 CPGDLHC622 VEL1225 DataLec™ Clip Contractor Pack (Heavy duty pins 17mm) (500xclips,HC617pins,cable ties 200x4.8mm Black, Fuel cell) DataLec™ Clip Contractor Pack (Heavy duty pins 22mm) (500xclips,HC622pins, cable ties 200x4.8mm Black, Fuel cell) Hook and loop strap 12mm x 25metre Roll (optional extra) Order Qty 1 1 1 Optional Item VEL1225 *NOTE: Testing concluded when clip pulled over pin head or strap/tie failed .Job site testing may be required before use to determine actual achievable job site values. Results have been achieved using a CableMasterTM tool set at minimum overdrive setting. Accessories failing to fix correctly should be removed and a new fixing set away from any spalled concrete. Tension load capacities are for static load situations only. Values shown represent a minimum factor of safety of 3:1 against the ultimate capacity.Minimum edge distance 75mm, minimum spacing between fixings 50mm. Tension loads are per fixing, a minimum of 3 fixings should be used per fastened unit. 1. Tested with Pricemark Cable Tie, # CT-76380NAT100 2. Tested with VELCRO Brand strap - 12mm VELCRO @ 60mm overlap with 50mm diam bundle. VELCRO® is a registered trademark of Velcro Industries B. V. Ramset™ recommends application test on-site before commencing use. 18 18 www.ramset.com.au www.ramset.com.au 1300 780 063 1300 780 063 DataLec™Clip Multi-purpose Data & Cable Clip Electrical cable bundles Multiple data cable bundles Fibre optic cable in conduit Electrical cable Data cable bundles Fibre optic cable Electrical cable www.ramset.com.au www.ramset.com.au 1300 780 063 1300 780 063 Gas Technology Systems Plastic pipe or conduit 19 19 EClip™ CableMaster™ Consumables Description Gas Technology Systems The EClip™ is ideal for firmly securing conduit, HDPE, and PVC pipe. Once installed, the clip is able to be rotated to allow for precise positioning of rigid and flexible tube. The design of the EClip™ incorporates interlocking connections to allow for multiple clips to be joined together side by side for a professional finish. Specifications High quality polypropylene Halogen free. Fire resistant 0.5 and 1 metre (approx) Raw Material Spacing Recommendation Features & Benefits • The EClip™ is designed to clip easily onto the CableMaster™ Pin Guide from the side allowing one-handed operation. • Hands are a safe distance from the Pin Guide during installation. • Fixing is precise. • After installation the EClip™ can be rotated around the pin to adjust alignment. • The slotted design of EClip™ absorbs energy, preventing the pin head from splitting the clip. • The hollow structure of the EClip™ gives flexibility for easy insertion of conduit. • EClip™ incorporates male/female connections allowing multiple conduit installation side by side. • Optional plug and screw installation. Pin Selection Guide Performance Table Substrate Hard Concrete >50MPa Concrete <50MPa Hollow Concrete Block Steel Steel Decking 4 Suitable k Possible HC617 4 4 k 4 4 HC622 4 4 4 4 4 Tube extraction loads at 22°C Force required to manually remove tube from the clip Clip Size 16mm 20mm 25mm Average Ultimate Load (approx) 4kg 6kg 8kg Installation Procedure 1. Side mount the EClip™ onto the tool Pin Guide. 2. Fixing is quick and precise. 3. When fixed, it can be easily rotated around the pin to adjust its position. EClip™ Conduit Clip Pulsa 800 Part No P8CPGEC16 P8CPGEC20 P8CPGEC25 Original Pulsa 700 Part No CPGEC16 CPGEC20 CPGEC25 Description Contractor Pack (500 x clips, HC622 Pins, Fuel Cell) Contractor Pack (500 x clips, HC622 Pins, Fuel Cell) Contractor Pack (500 x clips, HC622 Pins, Fuel Cell) Pipe / Conduit Diameter Order Qty 16mm 20mm 25mm 1 1 1 Ramset™ recommends application test on-site before commencing use. 20 www.ramset.com.au 1300 780 063 Threaded Rod Hanger CableMaster™ Consumables Description For light duty applications the Threaded Rod Hanger bracket is an ideal alternative to traditional anchors such as the DynaSet™ drop-in anchor. The bracket features an M8 and a M10 thread allowing for a choice of threaded rod sizes in applications such as light duty cable tray and pipe suspension. The bending movement used during application acts as a self testing mechanism for the quality of the fixing. Gas Technology Systems Specifications Raw Material Material Thickness Coating Carbon Steel 1.5mm Zinc Electroplated (Min. Coating 7µm) Features & Benefits • • • • • Slide-on channel for pin guide. Lateral insertion for fast, safe installation. Thick steel with reinforcing ribs for extra strength. Dual threads. Less parts, more flexibility. Optional drill and 6mm anchor installation. Electro zinc coating protects against corrosion. Performance Table* TRH with HC617 Pulsa™ Pin Load Capacity (Tension) - Concrete 32MPa 15kg *NOTES: 1. Values represent the maximum recommended working load in tension. 2. A minimum of 4 fastenings per fastened unit must be used. Pin Selection Guide Substrate Hard Concrete >50MPa Concrete <50MPa Hollow Concrete Block Steel Steel Decking 4 Suitable k Possible HC617 4 4 4 4 4 HC622 k k 4 k 4 3. Results have been achieved with a CableMaster™ tool. 4. All visible failures must be replaced and a new fixing set away from any spalled concrete. 5. Tension loads provided are for static load situations only. 6. Job-site testing may be required to determine actual achievable job-site values. 7. Pins must be sufficiently set, such that the underside of the head of the pin is in contact with the surface. Installation Procedure 1. Insert TRH laterally onto CableMaster™ pin guide to the stop position. 2. Install the TRH. The pin guide will automatically remove itself from the channel. If the guide is stuck inside the channel, gently move the tool laterally to release it. 3. Screw in the threaded rod, (two possible diameters) and bend the TRH to the vertical position using the rod or Bend the TRH by hand if you intend to use a suspended hanging system, small chain or steel wire. Threaded Rod Hanger Pulsa 800 Part No Original Pulsa 700 Part No P8CPGTRH CPGTRH TyMaster™ powder actuated tool installations For heavy duty applications refer to Z Bracket rod Hanger (M10) Page 52.This is a rod hanger assembly for TyMaster™ powder actuated tool installations. Description Threaded Rod Hanger Contractor Pack (400 x hangers, HC617 Pins, Fuel Cell) Thread Diameter Order Qty M8 - M10 1 Ramset™ recommends application test on-site before commencing use. www.ramset.com.au 1300 780 063 21 FP FireFix™ Clips CableMaster™ Consumables Description Gas Technology Systems The FP FireFix™ clip fire cable installation system has been developed for installing the specialised fire protection cable required for the safe operation of essentail service equipment during fire emergencies. This system consists of the FP FireFix™ clip installed with a Pulsa™ pin using the CableMaster™ Pulsa™ gas tool. Specifications Raw Material Coating Stainless Steel Powder coated red Features & Benefits • • • • • • • • • • • Complies to AS1530.4 Fixes fire rated cables ten times faster than traditional drilling methods Clip manufactured from 316 Stainless Steel powder coated Simply clips shut holding the cable(s) securely. 2 cables per clip Can be used with stainless steel cable ties to install larger cables Fast fixing to non combustible materials such as solid concrete, hollow concrete block and steel Two hour fire protection system for essential services. Utilises a plastic adaptor that fits on the CableMaster™ Pin Guide allowing one-handed installation. Hands are a safe distance from the Pin Guide during installation. Can be used with the PulsaLift™ Pole to fix from the ground. Holds one or two cables. Choice of two sizes. Simply clips shut holding the cable(s) securely. 2 cables per clip. Pin Selection Guide Substrate Hard Concrete >50MPa Concrete <50MPa Hollow Concrete Block Steel Steel Decking 4 Suitable k Possible HC617 4 4 4 4 4 HC622 4 4 4 4 4 Fire Standards Compliance When independently tested in accordance with the requirements of the Fire Test Method for Supports & Fixings of AS/NZS 3013:1995 appendix B, “Electrical Installations – Classification of the Fire & Mechanical Performance of Wiring Systems”, the FP FireFix Cable Clip (when fixed to the concrete slab via a Ramset 20mm Heavy Duty Concrete SC6 Gas Pin or HC617 Pin) was found to be able to support a static load of 1kg. Fire test reports are available upon request. Installation Procedure 1. Fit adaptor to the CableMaster™ pin guide. 2. Position the FP FireFix™ clip 3. Push the tool against the substrate and fix the FP FireFix™ clip in place. NOTE: remove battery from the tool when fitting the FP FireFix™ adaptor. FireFix™ Pulsa 800 Part No Original Description Pulsa 700 Part No FireFix™ Clip Contractor Pack (500 x clips, HC617 Pins, 5 P8CPGFPO2 CPGFPO2 Fastener Guide Adaptors) FireFix™ Clip Contractor Pack (500 x clips, HC617 Pins, 5 P8CPGFPO4 CPGFPO4 Fastener Guide Adaptors) Cable Outer Diameter Order Qty 7 - 8.1mm 1 8 - 9.5mm 1 Ramset™ recommends application test on-site before commencing use. 22 www.ramset.com.au 1300 780 063 CableHorn™ CableMaster™ Consumables Description In many applications the use of the CableHorn™ system can eliminate the need for cable trays to be installed. Cables may be added or removed after the CableHorn™ is installed. When used in conjunction with the PulsaLift™ pole system, CableHorns™ may be installed from the ground without the need for ladders or scissor lifts. Single CableHorn™: 8 cables, 3 x 1.5mm2 maximum. Double CableHorn™; 16 cables, 3 x 1.5mm2 maximum Between 0.60m and 1.50m High impact modified Pa66 Halogen free polypropylene. Incandescent wire test (IEC 695): 650 °C UL94 HB (ISO 1210): 100 mm/min No breakage at 0 °C TUV certificate ISO 9001 Single CableHorn™: Length 137mm. Double CableHorn™: Length 228mm Single CableHorn™: 19.5 x 38.5mm. Double CableHorn™: 19.5 x 24.3mm Capacity Spacing Recommendations Raw Material Fire Resistance Properties Low Temperature Tests Quality Certificate Dimensions Fixing Base Pin Selection Guide Substrate Hard Concrete >50MPa Concrete <50MPa Hollow Concrete Block Steel Steel Decking 4 Suitable k Possible HC622 4 4 4 4 4 Features & Benefits • Designed for use with electrical, data and communication cables. • Replaces the need for cable tray and catinary wire. • Clips directly onto the CableMaster™ Pin Guide allowing one-handed operation. • Can be used with the PulsaLift™ Pole to fix from the ground. • Add or remove cables as required. • In-built energy absorber for perfect embedment. • Large fixing base for better stability. • Flexibility in installation-vertical, horizontal, overhead. • Optional plug and screw installation. Gas Technology Systems Specifications Performance Table* Load Capacity (Tension) - Concrete 20MPa 32MPa 18kg 20kg Pin HC622 Installation Procedure 1. Simply clip the CableHorn™ to the tool pin 2. Press against the substrate (5kg to actuate the tool) press the trigger to fix. 3. Install the cable simply by lifting the edge of the CableHorn™. CableHorn™ Fixing Pulsa 800 Part No Original Pulsa 700 Part No P8CPGCH140 CPGCH140 P8CPGCH CPGCH Description CableHorn™ Contractor Pack (200 x fixings, HC622 Pins, Fuel Cell) CableHorn™ Contractor Pack (125 x fixings, SC620 Pins, Fuel Cell) Fixing Capacity Order Qty 8 Cables (3 x 1.5mm2) 1 16 Cables (3 x 1.5mm2) 1 *NOTE: Test concluded when clip pulled over pin head or pin failed. Job-site testing may be required to determine actual achievable job-site values. Results have been achieved with a CableMaster™ tool set at minimum overdrive setting. Accessories failing to fix correctly should be removed and a new fixing set away from any spalled concrete. Tension loads provided are for static load situations only. Values represent a minimum factor of safety of 3:1 on the lowest test results achieved. Minimum edge distance 75mm, minimum spacing between fixings 50mm. Tension loads are per fixing, however a minimum of 3 fixings per fastening unit should be used. Ramset™ recommends application test on-site before commencing use. www.ramset.com.au 1300 780 063 23 Conduit Half Saddle CableMaster™ Consumables Description Conduit Half Saddles are suitable for fixing conduit and metal pipes. Standard Half Saddles may be used with the CableMaster™ tool in conjunction with a Saddle Adaptor. Direct Alignment Saddles make the job even faster by clipping directly onto the fastener guide. Gas Technology Systems Specifications Raw Material Material Thickness Coating Carbon Steel 1.6mm Zinc Electroplated (Min. Coating 7µm) Features & Benefits • FAST accurate fixing of conduits and tubes to concrete,hollow block, & steel. • Fits directly to nose piece of CableMaster™ Pulsa™ gas tool • Precise hole alignment. • Optimum pin penetration and strength. • Neat and flush finish. • One hand installation. • Optional drill and 5mm anchor installation. • Site test recommended for use in critical applications. Direct Alignment Conduit Half Saddles Pin Selection Guide Substrate Hard Concrete >50MPa Concrete <50MPa Hollow Concrete Block Steel Bondeck 4 Suitable k Possible HC617 4 4 4 4 4 HC622 4 4 4 4 4 Installation Procedure 1. Gently place saddle assembly into end of pin guide. 2. Place saddle over conduit/tube. 3. Depress nose piece against work surface, fire tool. Direct Alignment Conduit Half Saddles 24 Pulsa 800 Part No Original Pulsa 700 Part No P8CPGDAS20 CPGDAS20 P8CPGDAS25 CPGDAS25 Description Direct Alignment Saddle Contractor Pack (400 x saddles, HC617 Pins, Fuel Cell) Direct Alignment Saddle Contractor Pack (400 x saddles, HC617 Pins, Fuel Cell) www.ramset.com.au 1300 780 063 Pipe / Conduit Diameter Order Qty 20mm 1 25mm 1 Strap/Plate Washer CableMaster™ Consumables Description Gas Technology Systems The Strap and Plate Washer may be used in a wide variety of applications where thin materials or fixtures with existing holes need to be quickly fastened. Common applications where the Strap and Plate washer are used include securing thin metal, nylon and Velcro straps for ducting, cable bunches and other fixtures. Brackets with existing pre-drilled holes for traditional mechanical fasteners can be secured with the use of strap and plate washers. Specifications Steel type Steel Thickness Nominal Diameter CA2S-E. 1.6mm providing a high resistance to deformation. 16mm Features & Benefits • FAST One-Step Fixing of metal, nylon and velcro straps for ductwork, cable bunches and fixture installations. • Suitable to span wide mounting holes in cable suspension brackets or switchboxes up to 8mm diam. • To reinforce mounting holes in brackets and prevent fixture pullover. • Precise hole alignment. • Use with pre-drilled or solid straps and plates. • Suitable for use with CableMaster™ Pulsa™ collated pins. • Choose the pin length to suit the application. • SC6 or HC6 pins recommended. • One handed fixing to concrete, hollow block and steel. Pin Selection Guide Substrate Hard Concrete >50MPa Concrete <50MPa Hollow Concrete Block Steel Steel Decking 4 Suitable k Possible HC617 4 4 4 4 4 HC622 4 4 4 4 4 Installation Procedure 1. Gently place washer assembly into end of nose piece. 2. Place assembly tip in position. 3. Depress nose piece against work surface, fire tool. Strap and Plate Washer Part No SPMW Description Strap and Plate Washer Order Qty 500 Ramset™ recommends application test on-site before commencing use. www.ramset.com.au 1300 780 063 25 Catenary Wire Bracket CableMaster™ Consumables Description Reinforced steel angle bracket, with closed eye for catenary wire and cable installations when fixing to concrete, concrete block and steel. Suitable for light to medium duty, close to ceiling applications. Specifications Gas Technology Systems Steel type CA2S-E. 2mm providing a high resistance to deformation. 7.5mm Steel Thickness Nominal Fixing Hole Diameter Features & Benefits • For catenary wire, cable, and hanger rod installations when fixing to concrete, hollow block and steel. • Improved clampdown to work surface with dimpled baseplate. • Optimum pin penetration with cushioned base. • Strengthening ribs reduce bracket twist and deformation. • Rounded edges to prevent cable damage. • Three methods of installation. - Fast fixing with CableMaster™ Pulsa™ gas tool. - TyMaster™ tool installation (See page 52). - Traditional drill and anchor method. • Suits light to medium duty fixing applications. (see performance table) • Fix from the ground with pole tool. • Eye size - 7mm. Pin Selection Guide Performance Table* Substrate Hard Concrete >50MPa Concrete <50MPa Hollow Concrete Block Steel Steel Decking 4 Suitable k Possible HC617 4 4 4 4 4 HC622 4 4 4 k 4 Load Capacity (Tension) - Concrete 32MPa 14kg Product Cat Brkt Pulsa assembly, HC617 Pin Installation Procedure 1. Place bracket assembly into the pin guide. 2. Depress pin guide against work surface, fix bracket into position. 3. Attach cables and wires as required. Catenary Wire Bracket Assembly Pulsa 800 Part No Original Pulsa 700 Part No P8CPGCWB CPGCWB Description Order Qty Catenary Wire Bracket Contractor Pack (400 x brackets, HC617 Pins, Fuel Cell, 200mm x 4.8mm Black) *Notes: 1. Values represent the maximum recommended working load in tension. 2. A minimum of 5 fastenings per fastened unit must be used. 3. Results have been achieved with a CableMaster™ tool. 4. All visible failures must be replaced and a new fixing set away from any spalled concrete. 5. Tension loads provided are for static load situations only. 6. Job-site testing may be required to determine actual achievable job-site values 7. Minimum edge distance 75mm. Minimum spacing between fixings 50mm. Ramset™ recommends application test on-site before commencing use. 26 www.ramset.com.au 1300 780 063 1