Preview only show first 10 pages with watermark. For full document please download

Cabling Solutions

   EMBED


Share

Transcript

CAT 6A Copper Cabling System CAT 6 Copper Cabling System Fibre Cabling System Fibre Accessories Accessories Cabinets & Racks Your Right Connection Voice System Solutions ISIN Code: DE000A1E8G88 CAT 5e Copper Cabling System Cabling Solutions 2015 VIVANCO PRODUCT INFORMATION Your Right Connection About Vivanco Established in 1920 Vivanco a listed company headquartered in Ahrensburg Germany is a multi-specialist manufacturer in the consumer electronics and connectivity solutions space. Vivanco is now part of an diversified MNC conglomerate group with annual group turnover of over 300 million Euro and over 5000 dedicated professionals with expertise in R&D, sales & marketing, product development, QC, administration and manufacturing spread across Europe, Asia and America is now rapidly expanding into the Asia region. Vivanco is a multi specialist manufacturer for equipment and structured cabling solutions in Europe both in terms of breadth and depth of its solution in the consumer electronics and connectivity solutions. The concept “Your Right Connection” encompasses Vivanco’s focus to drive their business forward while benefiting from new technologies giving Vivanco a ranking of No. 2 overall for consumer electronics in Germany. Vivanco offers end-to-end integrated solution in intelligent building industry from server room to desk outlet or campus wide network with its complete range of copper, fibre, smart home, data center, racks and security cabling solutions. Backed by dedicated and experienced technical and marketing professionals with average team experience of no less than 10 years. Vivanco offers comprehensive warranty and product application training to its customers worldwide through its various programs. Vivanco dedicates long-term commitment to support its customers and partners in the region it operates in is reflected by its individual country policy of hiring dedicated professional, tailor made product and solutions and distribution model along with adapting its best global practices for each country translating to a win-win situation for its customer and partners alike. About Vivanco Environmental Protection & Management Vivanco in every stage, from the initial design and development set, used in the manufacture of raw materials for identification, from production to shipment to the best use of scarce natural resources for our goal. On the premise of to ensure minimum waste, continuous improvement and to explore the way of production of cable. We seek to continuously improve, in as far as possible to reduce resource consumption and better under the circumstances of the use of energy in each production base to carry out our business. Once all products meet EOL will be disposed in the form of science. Efficient Logistics System Vivanco with professional background support system, as a whole order processing, production and manufacturing, materials processing and transport, can have a limited amount of time on the needs of customers in a rapid deployment, to ensure that both custom and conventional inventory products, can quick turnover. Vivanco is to ensure customer satisfaction, the value of this concept into every employee, it ensures that the products in the shortest possible time to arrive at the customer site. Vivanco understands the various regions and countries for different requirements of the packaging and logistics, and take proper measures, to make it meet the standards and requirements of each country, which translates into zero defect of logistics network. About Vivanco Brand Values & Philosophy Your Right Connection Vivanco is a multi-specialist manufacturer in the consumer electronics and connectivity solutions. “NO COMPROMISE” is our motto when it comes to providing users with reliable and high performance products. Vivanco believes in making every connection: "Your Right Connection" in becoming a market leader in integrated wiring and consumer electronics industry. Innovation, Research & Development & Quality Assurance Vivanco is at the forefront of innovation, by listening to our customer needs at the frontline and we develop cutting edge products and solutions exceeding their expectations. Vivanco through its unique customer feedback mechanisms, constantly develop new products via our specialized research and development center way ahead of our competitors in the field of innovation. More than 500 experts from Asia and Europe form the strength of the team, using the latest research and development tools and processes, involved in all stages of product development: from the mold design, to manufacturing processes, to the test of the sample, to provide our customer with the most cost effective and reliable solutions. Vivanco is always ready to invest when it comes to strategic innovations. Our intelligent copper and fiber cabling solutions are developed by working with closely with key customers who found existing solutions in the market cannot meet their needs. Today, Vivanco has its own mold making factory and the latest model of numerical control equipment to develop new products to ensure the final product to meet customer's demand on quality, safety, function and cost expectations, improve precisions and accuracies. All products are produced in line with the requirements of ISO9001 certification. Contents F eC Fibr Cabling System Cabinets & Racks C Copper Cabling System Page 001-047 CAT 6A Copper Cabling System CAT 6 Copper Cabling System CAT 5e Copper Cabling System Voice System Solutions Fibre Cabling System Page 048-089 Fibre Cabling System Fibre Accessories Accessories Page 090-099 Accessories Cabinets & Racks Page 100-123 Cabinets & Racks www.vivanco.asia Copper Cabling System VIVANCO offers end-to-end copper cabling solution in data center, horizontal cabling and server room etc. •CAT 6A Copper Cabling System --------------------------------------------001 •CAT 6 Copper Cabling System---------------------------------------------- 015 •CAT 5e Copper Cabling System-------------------------------------------- 027 •Voice System Solutions------------------------------------------------------ 039 www.vivanco.asia CAT 6A Copper Cabling System Vivanco CAT 6A end to end S/FTP, U/FTP solution comprises of cable, patch panel, patch cords and 360° shielded information outlets/jacks. The CAT 6A system offers superior electrical performance meeting 10G Base-T requirements under all challenging conditions with design feature minimizing noise interference while maintaining signal integrity. Suitable for high speed environment such as data centers, server farms, high resolution video streaming and other demanding and bandwidth intensive application. • Independently verified by 3rd party test labs • Exceed ISO/IEC 11801, IEC 61156-5, ANSI/TIA/EIA-568-C.2 Class Ea standards backward compatible to CAT 6 and CAT 5e and 1000 Base-T applications • Excellent suppression of alien cross talk (AXT) • Migration to 10Gbase-T as and when required offers best in class return of Investment S/FTP CAT 6A Cable • Patented unique shielded design • 23 AWG cable U/FTP CAT 6A Cable • Patented unique shielded design • 23 AWG cable Patch Panel • Exceed all TIA 568-C.2 component requirement • Patented individually removable shielded information outlets • Accepts wide range of cable diameter • Rear cable tray • All accessories included Modular Jack • Exceed all TIA 568-C.2 component requirement • Patented information outlets accepts larger diameter cable for other applications • 360° shielding • Tool free installation Patch Cord • Exceed all TIA 568-C.2 component requirement • Shielded construction ensures drastic reduction in AXT interference • Strain relief boots ensures long term performance • Snagless design with choice of lengths and colors www.vivanco.asia 001 Electrical Performance Conductor Insulantion (Skin-Foam-Skin) Foil Direct Current Resistance of Each Conductor <9.38Ω/100m Operating Capacitance ≤5.6nF/100m Unbalanced Capacitance ≤330pF/100m Braid Jacket Rip cord 1~100MHz 100±15% Impedance (Ω) 100~250MHz 100±22% 250~500MHz 100±25% Compliance • ISO/IEC 11801 • ANSI/TIA/EIA-568-C.2 • IEC 61156-5 NVP Propagation Delay 68% ≤44ns Construction • S/FTP • 23 AWG, solid bare copper (99.9%) • Jacket diameter: 8.25±0.3mm Physical Performance Tensile Min. Bend Radius Features & Benefits • Frequency 1-500 MHz, extended to 600 MHz • Suitable for 10 Gigabit,10G Base-T, Ethernet application • Aluminum foil for individual pairs and overall metal braid shielding reduce NEXT and ANEXT 002 110N 10 times max jacket diameter Installation Temperature 0~50°C (32~122°F) Storage Temperature -20~75°C (-4~167°F) Operating Temperature -20~60°C (-4~140°F) www.vivanco.asia CAT 6A Copper Cabling System Copper Cabling System CAT 6A S/FTP 4 Pair Cable, Shielded Name Coding VP CA SF A4 XX X X TYPE STRUCTURE CATEGORY/PAIR RATING COLOR LENGTH CA=Copper Cable SF=S/FTP A4=CAT 6A, 4 Pair CR=CMR B=Blue 3=305m CM=CM G=Grey LS=LSZH K=Black PV=PVC P=Purple PE=LDPE(outdoor) Ordering Information Part No. Description VPCASFA4CMB3 CAT 6A S/FTP Shielded Cable, CM, Blue, 305m/Drum VPCASFA4CMG3 CAT 6A S/FTP Shielded Cable, CM, Grey, 305m/Drum VPCASFA4PVB3 CAT 6A S/FTP Shielded Cable, PVC, Blue, 305m/Drum VPCASFA4PVG3 CAT 6A S/FTP Shielded Cable, PVC, Grey, 305m/Drum VPCASFA4LSP3 CAT 6A S/FTP Shielded Cable, LSZH, Purple, 305m/Drum VPCASFA4PEK3 CAT 6A S/FTP Shielded Cable, PE, Black, 305m/Drum www.vivanco.asia 003 Copper Cabling System CAT 6A U/FTP 4 Pair Cable, Shielded Electrical Performance Conductor Insulantion (Skin-Foam-Skin) Foil Jacket Direct Current Resistance of each Conductor <9.38Ω/100m Operating Capacitance ≤5.6nF/100m Unbalanced Capacitance 330pF/100m Rip cord 1~100MHz 100±15% Impedance (Ω) 100~250MHz 100±22% 250~500MHz 100±25% Compliance • ISO/IEC 11801 • ANSI/TIA/EIA-568-C.2 • IEC 61156-5 NVP Propagation Delay 68% ≤44ns Construction • U/FTP • 23 AWG, solid bare copper (99.9%) • Jacket diameter: 8.25±0.3mm Physical Performance Tensile Min. Bend Radius Features & Benefits • Frequency 1-500 MHz, extended to 600 MHz • Suitable for 10 Gigabit, 10G Base-T, Ethernet application • Aluminum foil for individual pairs shielding reduce NEXT and ANEXT 004 Installation Temperature 110N 10 times max jacket diameter 0~50°C (32~122°F) Storage Temperature -20~75°C (-4~167°F) Operating Temperature -20~60°C (-4~140°F) www.vivanco.asia CAT 6A Copper Cabling System Copper Cabling System CAT 6A U/FTP 4 Pair Cable, Unshielded Name Coding VP CA UF A4 XX X X TYPE STRUCTURE CATEGORY/PAIR RATING COLOR LENGTH CA=Copper Cable UF=U/FTP A4=CAT 6A, 4 Pair CR=CMR B=Blue 3=305m CM=CM G=Grey LS=LSZH K=Black PV=PVC P=Purple PE=LDPE(outdoor) Part No. Description VPCAUFA4CRB3 CAT 6A U/FTP Unshielded Cable, CMR, Blue, 305m/Drum VPCAUFA4CRG3 CAT 6A U/FTP Unshielded Cable, CMR, Grey, 305m/Drum VPCAUFA4CMB3 CAT 6A U/FTP Unshielded Cable, CM, Blue, 305m/Drum VPCAUFA4CMG3 CAT 6A U/FTP Unshielded Cable, CM, Grey, 305m/Drum VPCAUFA4PVB3 CAT 6A U/FTP Unshielded Cable, PVC, Blue, 305m/Drum VPCAUFA4PVG3 CAT 6A U/FTP Unshielded Cable, PVC, Grey, 305m/Drum VPCAUFA4LSP3 CAT 6A U/FTP Unshielded Cable, LSZH, Purple, 305m/Drum VPCAUFA4PEK3 CAT 6A U/FTP Unshielded Cable, PE, Black, 305m/Drum www.vivanco.asia 005 Copper Cabling System CAT6A Keystone Jack, Shielded Electrical Characteristics DC 1000V(AC750V) 1min, no breakdown and Dielectric Strength arcing phenomena DC Resistance (Ω) ≤300 mΩ Connecting Reactance(Ω) Insulation Resistance(Ω) ≤20mΩ Under normal atmospheric pressure ≥500 mΩ Compliance • ANSI/TIA 568-C.2 Category 6A • ISO/IEC 11801 Class Ea Physical Characteristics IDC Phosphor bronze Phosphor bronze with RJ45 Pin 50μm gold plating Features & Benefits • 360° fully shielded design to effectively prevents EMI • Best impedance matching • Gold plated, to prevent surface oxidation and improve the performance of the contact so as to ensure the performance and service life Plug Insertion ≥1000 times IDC Insertion Life Span ≥250 times AWG 22~26AWG Wiring T568A/T568B Name Coding VP CJ N F A S TYPE STRUCTURE SHUTTER STYLE CATEGORY COLOR CJ=Copper Jack S=Shielded N=Non-shuttered F=Flat A=CAT 6A S=Silver Part No. VPCJSNFAS 006 S Description CAT 6A Shielded Keystone Jack www.vivanco.asia CAT 6A Copper Cabling System Copper Cabling System CAT6A 24 Port Patch Panel, Shielded Compliance Electrical Characteristics • ANSI/TIA 568-C.2 Category 6A • ISO/IEC 11801 Class Ea DC 1000V(AC750V) 1min, no breakdown and Dielectric Strength arcing phenomena Features & Benefits • Loaded with 24 jacks • Rear cable manager for cable management • Plenty of tag space, management of port information is clearer and more convenient • Standard 19”, widely used industry standard DC Resistance (Ω) ≤300 mΩ Connecting Reactance(Ω) ≤20mΩ Under normal atmospheric Insulation Resistance(Ω) pressure ≥500 mΩ Physical Characteristics IDC Phosphor bronze Phosphor bronze with RJ45 Pin 50μm gold plating Plug Insertion ≥1000 times IDC Insertion Life Span ≥250 times AWG 22~26AWG T568A/ T568B Wiring Name Coding VP CP TYPE CP=Copper Patch Panel U F A 24 1 A STRUCTURE STYLE CATEGORY PORT HEIGHT INSTALLATION S=Shielded F=Flat A=CAT 6A 24=24 Port 1=1U A=Easy Installation Ordering Information Part No. Description VPCPSFA241 CAT 6A Shielded Patch Panel VPCPSFA241A CAT 6A Shielded Patch Panel (Easy Installation) www.vivanco.asia 007 Copper Cabling System CAT 6A S/FTP Patch Cord, Shielded Compliance • Suitable for 10 Gigabit, 10G Base-T, Ethernet application • Each patch cord is 100% performance tested • Choice of lengths and colors • Staggering pin design reduces NEXT • 25 years system warranty Physical Performance Insulation Compliance •ISO/IEC 11801 • ANSI/TIA/EIA 568-C.2 • IEC 61156-5 Cable Construction • S/FTP • 26 AWG Skin-foam-skin RJ45 Pin Gold-plating Plug Insertion Life Span ≥750 times Conductor Stranded; 7*0.16mm Operating Temperature -20~60°C (-4~140°F) Name Coding VP CC SF AR XX X X TYPE STRUCTURE CATEGORY/CONDUCTOR RATING COLOR LENGTH CC=Copper Cord SF=S/FTP AR=CAT 6A/Stranded CR=CMR B=Blue 1=1m CM=CM G=Grey 2=2m LS=LSZH R=Red 3=3m PV=PVC Y=Yellow 5=5m Red Blue Yellow Jacket VPCCSFARCRG1 VPCCSFARCRR1 VPCCSFARCRB1 VPCCSFARCRY1 CMR VPCCSFARCMG1 VPCCSFARCMR1 VPCCSFARCMB1 VPCCSFARCMY1 CM VPCCSFARLSG1 VPCCSFARLSR1 VPCCSFARLSB1 VPCCSFARLSY1 LSZH Grey 1 VPCCSFARPVG1 VPCCSFARPVR1 VPCCSFARPVB1 VPCCSFARPVY1 PVC VPCCSFARCRG2 VPCCSFARCRR2 VPCCSFARCRB2 VPCCSFARCRY2 CMR VPCCSFARCMG2 VPCCSFARCMR2 VPCCSFARCMB2 VPCCSFARCMY2 CM VPCCSFARLSG2 VPCCSFARLSR2 VPCCSFARLSB2 VPCCSFARLSY2 LSZH 2 VPCCSFARPVG2 VPCCSFARPVR2 VPCCSFARPVB2 VPCCSFARPVY2 PVC VPCCSFARCRG3 VPCCSFARCRR3 VPCCSFARCRB3 VPCCSFARCRY3 CMR VPCCSFARCMG3 VPCCSFARCMR3 VPCCSFARCMB3 VPCCSFARCMY3 CM LSZH 3 VPCCSFARLSG3 VPCCSFARLSR3 VPCCSFARLSB3 VPCCSFARLSY3 VPCCSFARPVG3 VPCCSFARPVR3 VPCCSFARPVB3 VPCCSFARPVY3 PVC VPCCSFARCRG5 VPCCSFARCRR5 VPCCSFARCRB5 VPCCSFARCRY5 CMR VPCCSFARCMG5 VPCCSFARCMR5 VPCCSFARCMB5 VPCCSFARCMY5 CM 5 VPCCSFARLSG5 VPCCSFARLSR5 VPCCSFARLSB5 VPCCSFARLSY5 LSZH VPCCSFARPVG5 VPCCSFARPVR5 VPCCSFARPVB5 VPCCSFARPVY5 PVC 008 Length(m) www.vivanco.asia CAT 6A Copper Cabling System Copper Cabling System CAT 6A Unshielded System Solutions INTRODUCTION Vivanco CAT 6A end to end unshielded solution comprises of cable, patch panel, patch cords and information outlets/ jacks. The CAT 6A system offers superior electrical performance meeting 10G Base-T requirements for applications such as data centers, server farms and other bandwidth intensive application . • Independently verified by 3rd party test labs • Exceed ISO/IEC 11801, IEC 61156-5, ANSI/TIA/EIA-56 8-C.2 class E standards backward compatible to CAT 5e applications • Excellent margin with suppression of cross talk (NEXT) CAT 6A Cable • 4 pair separator design • 23 AWG cable • Optionally available in LSZH and PE jacket Patch Panel • Exceed all TIA 568-C.2 component requirement • Modular design • Tower IDC design ensures separation of pairs for easy installation • Choose from 24 or 48 port(2U) • Rear cable tray • All accessories included Modular Jack • Exceed all TIA 568-C.2 component requirement • Tower IDC design ensures separation of pairs for easy installation • 180° IDC • Toolless design to provide easy installation Patch Cord • Exceed all TIA 568-C.2 component requirement • 4 pair separator ensures better performance • Strain relief boots ensures long term performance • Snagless design with choice of lengths and colors • Optional LSZH jacket for special environment • 24 AWG conductors offers flexibility during usage www.vivanco.asia 009 Copper Cabling System CAT 6A U/UTP 4Pairs Cable, Unshielded Electrical Performance Conductor DC Resistance of Each Conductor ≤9.38Ω/100m Insulation(skin-foam-skin) Filler Jacket Unbalance DC Resistance of Each Pair ≤2.5% Rip Cord 1~100MHz 100±15% 100~250MHz 100±22% Impedance (Ω) 250~500MHz 100±25% Compliance •ISO/IEC 11801: 2008 • IEC 61156-5-2009 • ANSI/TIA-568-C.2 68% NVP ≤45ns/100m Propagation Delay Construction • U/UTP • 23 AWG, solid bare copper(99.9%) • Jacket diameter: 7.5±0.3mm Physical Characteristics Maximum Tension Features & Benefits • Comply with the ANSI/TIA-568-C.2 500 MHz bandwidth test requirements • Star shape filler to provide a better NEXT and ANEXT performance • Suitable for 10 Gigabit,10 G Base-T Ethernet application 010 110N Minimum Bending Radius 10 times max jacket diameter Installation Temperature 0~50°C (32~122°F) Storage Temperature -20~75°C (-4~167°F) Operating Temperature -20~60°C (-4~140°F) www.vivanco.asia CAT 6A Copper Cabling System Copper Cabling System CAT 6A U/UTP 4Pairs Cable, Unshielded Name Coding VP CA UU A4 XX X X TYPE STRUCTURE CATEGORY/PAIR RATING COLOR LENGTH CA=Copper Cable UU=U/UTP A4=CAT 6A, 4 pair CR=CMR B=Blue 3=305m CM=CM G=Grey LS=LSZH K=Black PV=PVC P=Purple PE=LDPE(outdoor) Ordering Information Part No. Description VPCAUUA4CRG3 CAT 6A U/UTP Unshielded Cable, CMR, Grey, 305m/Drum VPCAUUA4CRB3 CAT 6A U/UTP Unshielded Cable, CMR, Blue, 305m/Drum VPCAUUA4CMG3 CAT 6A U/UTP Unshielded Cable, CM, Grey, 305m/Drum VPCAUUA4CMB3 CAT 6A U/UTP Unshielded Cable, CM, Blue, 305m/Drum VPCAUUA4PVG3 CAT 6A U/UTP Unshielded Cable, PVC, Grey, 305m/Drum VPCAUUA4PVB3 CAT 6A U/UTP Unshielded Cable, PVC, Blue, 305m/Drum VPCAUUA4LSP3 CAT 6A U/UTP Unshielded Cable, LSZH, Purple, 305m/Drum VPCAUUA4PEK3 CAT 6A U/UTP Unshielded Cable, PE, Black, 305m/Drum www.vivanco.asia 011 Copper Cabling System CAT 6A Keystone Jack, Unshielded Electrical Characteristics DC 1000V(AC750V) 1min, no breakdown and Dielectric Strength arcing phenomena DC Resistance (Ω) ≤300 mΩ Connecting Reactance(Ω) Insulation Resistance(Ω) ≤20mΩ Under normal atmospheric pressure ≥500 mΩ Compliance •ANSI/TIA-568-C.2 Category 6A • ISO/IEC 11801 Class Ea Physical Characteristics IDC Phosphor bronze Phosphor bronze with RJ45 Pin 50μm gold plating Features & Benefits • Impedance matching between PCB & IDC leads to provide the best electrical performance • Toolless design to provide easy installation • Fully compatible with all Vivanco’s wallplate • Special design of IDC to reduce crosstalk Plug Insertion ≥1000 times IDC Insertion Life Span ≥250 times AWG 22~26AWG Wiring T568A/T568B Name Coding VP CJ U N F A X TYPE STRUCTURE SHUTTER STYLE CATEGORY LOLOR CJ=Copper Jack U=Unshieded N=Non-shuttered F=Flat A=CAT 6A W=White K=Black 012 Part No. Description VPCJUNFAWA CAT 6A Unshielded Keystone Jack, White, Toolless www.vivanco.asia CAT 6A Copper Cabling System Copper Cabling System CAT 6A Patch Panel, Unshielded Compliance Electrical Characteristics • ANSI/TIA-568-C.2 Category 6 • ISO/IEC 11801 Class E DC 1000V(AC750V) 1min, no breakdown and Dielectric Strength arcing phenomena Rated Current(Ω) ≤300 mΩ Connecting Reactance(Ω) ≤20mΩ Under normal atmospheric Insulation Resistance(Ω) Features & Benefits • Modular design for easy management • Rear cable manager for cable management • 19 "standard installation • Clear labeling system for easy management pressure ≥500 mΩ Physical Characteristics IDC Phosphor bronze Phosphor bronze with RJ45 Pin 50μm gold plating Plug Insertion ≥1000 times IDC Insertion Life Span ≥250 times AWG 22~26AWG Wiring T568A/ T568B Name Coding VP CP TYPE STRUCTURE STYLE CP=Copper Patch Panel U=Unshielded F=Flat U F A 24 2 CATEGORYTLE A=CAT 6A PORT 24=24 Port HEIGHT 2=2U Ordering Information Part No. Description VPCPUFA242 CAT 6A 24 Port Patch Panel, Unshielded, Loaded,2 U www.vivanco.asia 013 Copper Cabling System CAT 6A U/UTP Patch Cord, Unshielded Features & Benefits • Comply to TIA-568-C.2, 10G Base-T application • 100% performance test • A wide range of length and color for easy management • Staggered design of wire holder to reduce crosstalk Physical Performance Compliance Insulation •IOS/IEC 11801:2008 • ANSI/TIA-568-C2 • IEC 61156-5 Skin-foam-skin RJ45 Pin Gold-plating Plug Insertion Life Span Construction Conductor • U/UTP • 24 AWG ≥750 times Stranded, 7*0.16mm Operating Temperature -20~60°C Name Coding VP CC UU AR XX X X TYPE STRUCTURE CATEGORY/CONDUCTOR RATING COLOR CC=Copper Cord UU=U/UTP AR=CAT 6A/Stranded CR=CMR B =Blue 1=1m CM=CM G=Grey 2=2m LS=LSZH R=Red 3=3m PV=PVC Y=Yellow 5=5m Grey Red Blue LENGTH Yellow Jacket CMR VPCCUUARCRG1 VPCCUUARCRR1 VPCCUUARCRB1 VPCCUUARCRY1 VPCCUUARCMG1 VPCCUUARCMR1 VPCCUUARCMB1 VPCCUUARCMY1 CM VPCCUUARLSG1 VPCCUUARLSR1 VPCCUUARLSB1 VPCCUUARLSY1 LSZH VPCCUUARPVG1 VPCCUUARPVR1 VPCCUUARPVB1 VPCCUUARPVY1 PVC VPCCUUARCRG2 VPCCUUARCRR2 VPCCUUARCRB2 VVPCCUUARCRY2 CMR VPCCUUARCMG2 VPCCUUARCMR2 VPCCUUARCMB2 VVPCCUUARCMY2 CM VPCCUUARLSG2 VPCCUUARLSR2 VPCCUUARLSB2 VPCCUUARLSY2 LSZH VPCCUUARPVG2 VPCCUUARPVR2 VPCCUUARPVB2 VPCCUUARPVY2 PVC VPCCUUARCRG3 VPCCUUARCRR3 VPCCUUARCRB3 VPCCUUARCRY3 CMR VPCCUUARCMG3 VPCCUUARCMR3 VPCCUUARCMB3 VPCCUUARCMY3 CM LSZH VPCCUUARLSG3 VPCCUUARLSR3 VPCCUUARLSB3 VPCCUUARLSY3 VPCCUUARPVG3 VPCCUUARPVR3 VPCCUUARPVB3 VPCCUUARPVY3 PVC VPCCUUARCRG5 VPCCUUARCRR5 VPCCUUARCRB5 VPCCUUARCRY5 CMR VPCCUUARCMG5 VPCCUUARCMR5 VPCCUUARCMB5 VPCCUUARCMY5 CM VPCCUUARLSG5 VPCCUUARLSR5 VPCCUUARLSB5 VPCCUUARLSY5 LSZH VPCCUUARPVG5 VPCCUUARPVR5 VPCCUUARPVB5 VPCCUUARPVY5 PVC 014 Length(m) 1 2 3 5 www.vivanco.asia CAT 6A Copper Cabling System Copper Cabling System CAT 6 Shielded System Solutions CAT 6 Copper Cabling System INTRODUCTION Vivanco CAT6 end to end S/FTP solution comprises of cable, patch panel, patch cords and 360° shielded Information outlets/jacks. The CAT6 system offers superior electrical performance meeting 1000 Base-T requirements under challenging installation conditions such as factory environment and datacenters etc with design feature minimizing noise Interference while maintaining signal integrity. • Independently verified by 3rd party test labs • Exceed ISO/IEC 11801, IEC 61156-5, ANSI/TIA/EIA-568-C.2 Class E standards backward compatible to CAT 5e applications • Excellent margin with suppression of cross talk (NEXT) Cat6 Cable • Unique shielded design • 23 AWG cable • 4 pair separator design Patch Panel • Exceed all TIA 568-C.2 component requirement • Patented individually removable shielded information outlets • Accepts wide range of cable diameter • All accessories included Modular Jack • Exceed all TIA 568-C.2 component requirement • Patented information outlets accepts larger diameter cable for other applications • 360° shielding • Tool free installation Patch Cord • Exceed all TIA 568-C.2 component requirement • Shielded construction ensures drastic reduction in cross talk • Strain relief boots ensures long term performance • Snag less design with choice of lengths and colours www.vivanco.asia 015 Copper Cabling System CAT6 F/UTP 4 Pair Cable, Shielded Conductor Electrical Performance PET Insulation Direct Current Resistance of Each Conductor <9.38Ω/100m Operating Capacitance ≤5.6nF/100m Unbalanced Capacitance ≤330pF/100m Filler Foil Jacket Earth wire Rip cord 1~100MHz 100±15% Impedance (ohms) 100~250MHz 100±22% 250~500MHz 100±25% NVP Compliance Propagation Delay 68% ≤45ns • ISO/IEC 11801 • ANSI/TIA/EIA-568-C.2 • IEC 61156-5 Construction •F/UTP •23 AWG, solid bare copper •Jacket diameter: 7.8 ±0.3mm Physical Performance Tensile Features & Benefits • Frequency 1-250 MHz, extended to 500 MHz • Suitable for 1000Base-T, Ethernet application • Wire cross isolation improves NEXT and impedance performance • Aluminum foil avoids NEXT between the cable • 25 years system warranty 016 Min. Bend Radius Installation Temperature 110N 10 times max jacket diameter 0~50°C (32~122°F) Storage Temperature -20~75°C (-4~167°F) Operating Temperature -20~60°C (-4~140°F) www.vivanco.asia CAT 6A Copper Cabling System Copper Cabling System CAT6 F/UTP 4 Pair Cable, Shielded CAT 6 Copper Cabling System Name Coding VP CA FU 64 XX X X TYPE STRUCTURE CATEGORY/PAIR RATING COLOR LENGTH CA=Copper Cable FU=F/UTP 64 = CAT 6, 4 Pair CR=CMR B=Blue 3=305m CM=CM G=Grey LS=LSZH K=Black PV=PVC P=Purple PE=LDPE(outdoor) Ordering Information Part No. Description VPCAFU64CRB3 CAT 6 F/UTP Shielded Cable, CMR, Blue, 305m/Drum VPCAFU64CRG3 CAT 6 F/UTP Shielded Cable, CMR, Grey, 305m/Drum VPCAFU64CMB3 CAT 6 F/UTP Shielded Cable, CM, Blue, 305m/Drum VPCAFU64CMG3 CAT 6 F/UTP Shielded Cable, CM, Grey, 305m/Drum VPCAFU64PVB3 CAT 6 F/UTP Shielded Cable, PVC, Blue, 305m/Drum VPCAFU64PVG3 CAT 6 F/UTP Shielded Cable, PVC, Grey, 305m/Drum VPCAFU64LSP3 CAT 6 F/UTP Shielded Cable, LSZH, Purple, 305m/Drum VPCAFU64PEK3 CAT 6 F/UTP Shielded Cable, PE, Black, 305m/Drum www.vivanco.asia 017 Copper Cabling System CAT6 Keystone Jack, Shielded Electrical Characteristics DC 1000V(AC750V) 1min, no breakdown and Dielectric Strength arcing phenomena DC Resistance(Ω) ≤300 mΩ Connecting Reactance(Ω) Insulation Resistance(Ω) ≤20mΩ Under normal atmospheric pressure ≥500 mΩ Compliance • ANSI/TIA 568-C.2 Category 6 • ISO/IEC 11801 Class E Physical Characteristics Phosphor bronze IDC Phosphor bronze with RJ45 Pin Features & Benefits • 360° fully shielded design effectively prevents EMI • Best impedance matching • Gold plated, to prevent surface oxidation and improve the performance of the contact so as to ensure the performance and service life 50μm gold plating Plug Insertion ≥1000 times IDC Insertion Life Span ≥250 times AWG 22~26AWG Wiring T568A/T568B Name Coding VC CJ 018 S N F 6 S TYPE STRUCTURE SHUTTER STYLE CATEGORY LOLOR CJ=Copper Jack S=Shielded N=Non-shuttered F=Flat 6=CAT 6 S=Silver Part No. Description VCCJSNF6S CAT6 Shielded Keystone Jack www.vivanco.asia CAT 6A Copper Cabling System Copper Cabling System CAT6 24 Port Patch Panel, Shielded CAT 6 Copper Cabling System Compliance Electrical Characteristics • ANSI/TIA 568-C.2 Category 6 • ISO/IEC 11801 Class E DC 1000V(AC750V) 1min, no breakdown and Dielectric Strength arcing phenomena DC Resistance(Ω) Features & Benefits • Loaded with 24 jacks • Rear cable manager for cable management • Plenty of tag space, and the management of port information is clearer and more convenient • Standard 19”, widely used industry standard ≤300 mΩ Connecting Reactance(Ω) ≤20mΩ Under normal atmospheric Insulation Resistance(Ω) pressure ≥500 mΩ Physical Characteristics Phosphor bronze IDC Phosphor bronze with RJ45 Pin 50μm gold plating Plug Insertion ≥1000 times IDC Insertion Life Span ≥250 times AWG 22~26AWG Wiring T568A/T568B Name Coding VC CP S X 6 24 1 A TYPE STRUCTURE STYLE CATEGORY PORT CP=Copper Patch Panel S=Shielded F=Flat 6=CAT 6 24=24 Port HEIGHT INSTALLATION 1=1U A=Easy Installation G=Group Part No. Description VCCPSF6241 24 Port CAT 6 Shielded Patch Panel, 1U VCCPSG6241 24 Port CAT 6 Shielded Patch Panel, 1U (8 port as one unit) VCCPSF6241A 24 Port CAT6 Shielded Patch Panel, 1U (easy installation) VCCPSG6241A 24 Port CAT6 Shielded Patch Panel, 1U (8 port as one unit, easy installation) www.vivanco.asia 019 Copper Cabling System CAT 6 F/UTP Patch Cord, Shielded Features & Benefits • • • • • Suitable for 1000Base-T, Ethernet application Each patch cord is 100% performance tested Choice of lengths and colours Up down Pin improves NEXT performance 25 years system warranty Physical Performance Compliance HDPE Insulation •ISO/IEC 11801 • ANSI/TIA/EIA 568-C.2 • IEC 61156-5 50μ Gold-plating Plug Insertion Life Span Cable Construction Stranded, 7*0.16mm Conductor • F/UTP • 26 AWG ≥750 times Operating Temperature -20~60°C VP CC FU 6R XX X X TYPE STRUCTURE CATEGORY/CONDUCTOR RATING COLOR LENGTH CC=Copper Cord FU=F/UTP 6R=CAT 6, Stranded CR=CMR B=Blue 1=1m CM=CM G=Grey 2=2m LS=LSZH R=Red 3=3m PV=PVC Y=Yellow 5=5m Grey Red Blue Yellow Jacket CMR VPCCFU6RCRG1 VCCCFU6RCRR1 VCCCFU6RCRB1 VCCCFU6RCRY1 VPCCFU6RCMG1 VCCCFU6RCMR1 VCCCFU6RCMB1 VCCCFU6RCMY1 CM VPCCFU6RLSG1 VCCCFU6RLSR1 VCCCFU6RLSB1 VCCCFU6RLSY1 LSZH VPCCFU6RPVG1 VCCCFU6RPVR1 VCCCFU6RPVB1 VCCCFU6RPVY1 PVC CMR VPCCFU6RCRG2 VCCCFU6RCRR2 VCCCFU6RCRB2 VCCCFU6RCRY2 VPCCFU6RCMG2 VCCCFU6RCMR2 VCCCFU6RCMB2 VCCCFU6RCMY2 CM VPCCFU6RLSG2 VCCCFU6RLSR2 VCCCFU6RLSB2 VCCCFU6RLSY2 LSZH VPCCFU6RPVG2 VCCCFU6RPVR2 VCCCFU6RPVB2 VCCCFU6RPVY2 PVC VPCCFU6RCRG3 VCCCFU6RCRR3 VCCCFU6RCRB3 VCCCFU6RCRY3 CMR VPCCFU6RCMG3 VCCCFU6RCMR3 VCCCFU6RCMB3 VCCCFU6RCMY3 CM VPCCFU6RLSG3 VCCCFU6RLSR3 VCCCFU6RLSB3 VCCCFU6RLSY3 LSZH VPCCFU6RPVG3 VCCCFU6RPVR3 VCCCFU6RPVB3 VCCCFU6RPVY3 PVC VPCCFU6RCRG5 VCCCFU6RCRR5 VCCCFU6RCRB5 VCCCFU6RCRY5 CMR VPCCFU6RCMG5 VCCCFU6RCMR5 VCCCFU6RCMB5 VCCCFU6RCMY5 CM VPCCFU6RLSG5 VCCCFU6RLSR5 VCCCFU6RLSB5 VCCCFU6RLSY5 LSZH VPCCFU6RPVG5 VCCCFU6RPVR5 VCCCFU6RPVB5 VCCCFU6RPVY5 PVC 020 Length(m) 1 2 3 5 www.vivanco.asia CAT 6A Copper Cabling System Copper Cabling System CAT 6 Unshielded System Solutions CAT 6 Copper Cabling System INTRODUCTION Vivanco CAT 6 end to end unshielded solution comprises of Cable, patchpanel, patch cords and infor-mation outlets/jacks. The CAT 6 system offers s-uperior electrical performance meeting 1000 Base-T requirements for applications such as data centers, server farms and other bandwidth intensive application. • Independently verified by 3rd party test labs • Exceed ISO/IEC 11801, IEC 61156-5, ANSI/TIA/EIA-568-C.2 Class E standards, backward compatible to CAT 5e applications • Excellent margin with suppression of cross talk (NEXT) CAT6 Cable • 4 pair separator design • 23 AWG cable Patch Panel • Exceed all TIA 568-C.2 component requirement • Modular design • Tower IDC design ensures separation of pairs for easy installation • Choose from 24 (1U) or 48 ports (2U) • Rear cable tray • All accessories included Modular Jack • Exceed all TIA 568-C.2 component requirement • Tower IDC design ensures separation of pairs for easy installation • 180° IDC • Choose jack color depending on application Patch Cord • Exceed all TIA 568-C.2 component requirement • 4 pair separator ensures better performance • Strain relief boots ensures long term performance • Snagless design with choice of lengths and colors www.vivanco.asia 021 Copper Cabling System CAT6 U/UTP 4 Pair Cable, Unshielded Electrical Performance Conductor Insulation Direct Current Resistance of Each Conductor <9.38Ω/100m Operating Capacitance ≤5.6nF/100m Unbalanced Capacitance ≤330pF/100m Filler Jacket Rip cord Impedance (ohms) 1~100MHz 100±15% 100~250MHz 100±22% NVP Compliance Propagation Delay 68% ≤45ns • ISO/IEC 11801 • ANSI/TIA/EIA-568-C.2 • IEC 61156-5 Construction • U/UTP • 23 AWG, solid bare copper • Jacket diameter: 6.3±0.3 mm Physical Performance Tensile Min. Bend Radius Features & Benefits • Frequency 1-250MHz, extended to 500MHz • Suitable for 1000Base-T, Ethernet application • Wire cross isolation improves NEXT and impedance performance • 25 years system warranty 022 Installation Temperature 110N 10 times max jacket diameter 0~50°C (32~122°F) Storage Temperature -20~75°C (-4~167°F) Operating Temperature -20~60°C (-4~140°F) www.vivanco.asia CAT 6A Copper Cabling System Copper Cabling System CAT6 U/UTP 4 Pair Cable, Unshielded CAT 6 Copper Cabling System Name Coding VC CA UU 64 XX X X TYPE STRUCTURE CATEGORY/PAIR RATING COLOR LENGTH CA=Copper Cable UU=U/UTP 64=CAT 6, 4 Pair CR=CMR B=Blue 3=305m CM=CM G=Grey LS=LSZH K=Black PV=PVC P=Purple PE=LDPE(outdoor) Ordering Information Part No. Description VCCAUU64CRB3 CAT 6 U/UTP Unshielded Cable, CMR, Blue, 305m/Pull box VCCAUU64CRG3 CAT 6 U/UTP Unshielded Cable, CMR, Grey, 305m/Pull box VCCAUU64CMB3 CAT 6 U/UTP Unshielded Cable, CM, Blue, 305m/Pull box VCCAUU64CMG3 CAT 6 U/UTP Unshielded Cable, CM, Grey, 305m/Pull box VCCAUU64PVB3 CAT 6 U/UTP Unshielded Cable, PVC, Blue, 305m/Pull box VCCAUU64PVG3 CAT 6 U/UTP Unshielded Cable, PVC, Grey, 305m/Pull box VCCAUU64LSP3 CAT 6 U/UTP Unshielded Cable, LSZH, Purple, 305m/Pull box VCCAUU64PEK3 CAT 6 U/UTP Unshielded Cable, PE, Black, 305m/Pull box www.vivanco.asia 023 Copper cabling system CAT6 Keystone Jack, Unshielded Electrical Characteristics DC 1000V(AC750V) 1min, no breakdown and Dielectric Strength arcing phenomena DC Resistance(Ω) ≤300 mΩ Connecting Reactance(Ω) Insulation Resistance(Ω) ≤20mΩ Under normal atmospheric pressure ≥500 mΩ Compliance • ANSI/TIA 568-C.2 Category 6 • ISO/IEC 11801 Class E Physical Characteristics IDC Phosphor bronze Phosphor bronze with RJ45 Pin Features & Benefits • Best impedance matching • Wiring port 45° crossover design • Connecting points adopt the special to effectively reduce NEXT • Compatible with all Vivanco faceplate and unshielded patch panel • With the transparent cable cover to prevent the wire falling down VC CJ U 50μm gold plating Plug Insertion ≥1000 times IDC Insertion Life Span ≥250 times AWG 22~26AWG Wiring N T568A/ T568B F 6 X TYPE STRUCTURE SHUTTER STYLE CATEGORY CJ=Copper Jack U=Unshielded N=Non-shuttered F=Flat 6=CAT 6 LOLOUR W=White K=Black 024 Part No. Description VCCJUNF6W CAT6 Unshielded RJ45 Keystone Jack (White) VCCJUNF6K CAT6 Unshielded RJ45 Keystone Jack (Black) www.vivanco.asia CAT 6A Copper Cabling System Copper cabling system CAT6 Patch Panel, Unshielded CAT 6 Copper Cabling System Compliance Electrical Characteristics •ANSI/TIA 568-C.2 Category 6 •ISO/IEC 11801 Class E DC 1000V(AC750V) 1min, no breakdown and Dielectric Strength arcing phenomena DC Resistance(Ω) Features & Benefits • Standard 19” widely used industry standard adopts plastic front and steel rear frame • Rear cable manager for cable management • Connecting points adopt the special pin to effectively reduce NEXT • Each keystone can be individually disassembled • Offer 24 port (1U) and 48 port (2U) type ≤300 mΩ Connecting Reactance(Ω) ≤20mΩ Under normal atmospheric Insulation Resistance(Ω) pressure ≥500 mΩ Physical Characteristics IDC Phosphor bronze Phosphor bronze with RJ45 Pin 50μm gold plating Plug Insertion ≥1000 times IDC Insertion Life Span ≥250 times AWG 22~26AWG Wiring VC CP U F T568A/T568B 6 XX X A TYPE STRUCTURE STYLE CATEGORY PORT HEIGHT INSTALLATION CP=Copper Patch Panel U=Unshielded F=Flat 6=CAT 6 24=24 Port 1=1U A=Easy Installation 48=48 Port 2=2U Ordering Information Part No. Description VCCPUF6241 24 Port CAT6 Unshielded Patch Panel, 1U VCCPUF6482 48 Port CAT6 Unshielded Patch Panel, 2U VCCPUF6241A 24 Port CAT6 Unshielded Patch Panel, 1U (Easy Installation) www.vivanco.asia 025 Copper Cabling System CAT6 U/UTP Patch Cord, Unshielded Features & Benefits •Suitable for 1000 Base-T, Ethernet application •Each patch cord is 100% performance tested •Choice of lengths and colors •Up down Pin improves NEXT performance •25 years system warranty Physical Performance Compliance Insulation •IOS/IEC 11801:2008 • ANSI/TIA-568-C2 • IEC 61156-5 HDPE RJ45 Pin Gold-plating Plug Insertion Life Span ≥750 times Conductor Cable Construction •U/UTP •24AWG Stranded , 7*0.20mm Operating Temperature -20~60°C VC CC UU 6R XX X X TYPE STRUCTURE CATEGORY/CONDUCTOR RATING COLOR CC=Copper Cord LENGTH UU=U/UTP AR=CAT 6/Stranded CR=CMR B=Blue 1=1m CM=CM G=Grey 2=2m LS=LSZH R=Red 3=3m PV=PVC Y=Yellow 5=5m Grey Red Blue Yellow Jacket VCCCUU6RCRG1 VCCCUU6RCRR1 VCCCUU6RCRB1 VCCCUU6RCRY1 CMR VCCCUU6RCMG1 VCCCUU6RCMR1 VCCCUU6RCMB1 VCCCUU6RCMY1 CM VCCCUU6RLSG1 VCCCUU6RLSR1 VCCCUU6RLSB1 VCCCUU6RLSY1 LSZH VCCCUU6RPVG1 VCCCUU6RPVR1 VCCCUU6RPVB1 VCCCUU6RPVY1 PVC CMR VCCCUU6RCRG2 VCCCUU6RCRR2 VCCCUU6RCRB2 VCCCUU6RCRY2 VCCCUU6RCMG2 VCCCUU6RCMR2 VCCCUU6RCMB2 VCCCUU6RCMY2 CM VCCCUU6RLSG2 VCCCUU6RLSR2 VCCCUU6RLSB2 VCCCUU6RLSY2 VCCCUU6RPVG2 VCCCUU6RPVR2 VCCCUU6RPVB2 VCCCUU6RPVY2 LSZH PVC VCCCUU6RCRG3 VCCCUU6RCRR3 VCCCUU6RCRB3 VCCCUU6RCRY3 CM VCCCUU6RCMG3 VCCCUU6RCMR3 VCCCUU6RCMB3 VCCCUU6RCMY3 CM VCCCUU6RLSG3 VCCCUU6RLSR3 VCCCUU6RLSB3 VCCCUU6RLSY3 LSZH VCCCUU6RPVG3 VCCCUU6RPVR3 VCCCUU6RPVB3 VCCCUU6RPVY3 PVC VCCCUU6RCRG5 VCCCUU6RCRR5 VCCCUU6RCRB5 VCCCUU6RCRY5 CMR VCCCUU6RCMG5 VCCCUU6RCMR5 VCCCUU6RCMB5 VCCCUU6RCMY5 CM VCCCUU6RLSG5 VCCCUU6RLSR5 VCCCUU6RLSB5 VCCCUU6RLSY5 LSZH VCCCUU6RPVG5 VCCCUU6RPVR5 VCCCUU6RPVB5 VCCCUU6RPVY5 PVC 026 Length(m) 1 2 3 5 www.vivanco.asia CAT 6A Copper Cabling System Copper Cabling System CAT 5e Shielded System Solutions CAT 6 Copper Cabling System INTRODUCTION CAT 5e Copper Cabling System Vivanco CAT 5e end to end shielded solution comprises of cable, patch panel, patch cords and information outlets/jacks. The CAT 5e system offers superior electrical performance meeting Class D requirements. • Independently verified by 3rd party test labs • Exceed ISO/IEC 11801, IEC 61156-5, ANSI/TIA/EIA- 568-C.2 Class D standards • Excellent margin with suppression of cross talk CAT 5e Cable • Unique shielded design • 24 AWG cable Patch Panel • Exceed all TIA 568-C.2 component requirement • Patented information outlets accepts larger diameter cable for other applications • Available in 24/48 port format • All accessories included Modular Jack • Exceed all TIA 568-C.2 component requirement • Patented information outlets accepts larger diameter cable for other applications • 360° shielding • Tool free installation Patch Cord • Exceed all TIA 568-C.2 component requirement • Shielded construction ensures drastic reduction in eross talk • Strain relief boots ensures long term performance • Snagless design with choice of lengths and colors www.vivanco.asia 027 Copper Cabling System CAT5e F/UTP, SF/UTP 4 Pair Cable, Shielded Conductor Pet Insulation Foil Jacket Earth wire Rip cord Braid SF/UTP Conductor PET Insulation Foil Jacket Earth wire Rip cord Electrical Performance F/UTP Compliance • ISO/IEC 11801 • ANSI/TIA/EIA-568-C.2 • IEC 61156-5 Direct Current Resistance of each Conductor <9.38Ω/100m Operating Capacitance ≤5.6nF/100m Unbalanced Capacitance ≤330pF/100m Impedance (ohms) NVP Delay Deviation 1-100MHz 100±15% 67 % ≤45ns Construction • F/UTP, SF/UTP • 24 AWG, solid bare copper • Jacket diameter: F/UTP 6.4±0.2mm SF/UTP 6.6±0.2mm Physical Performance Tensile Min. Bend Radius Features & Benefits • Frequency 1-100MHZ, extended to 350MHZ • Suitable for 1000Base-T, Ethernet application • 25 years system warranty 028 Installation Temperature 110N 10 times max jacket diameter 0~50°C (32~122°F) Storage Temperature -20~75°C (-4~167°F) Operating Temperature -20~60°C (-4~140°F) www.vivanco.asia CAT 6A Copper Cabling System Copper Cabling System CAT5e F/UTP, SF/UTP 4 Pair Cable, Shielded CAT 6 Copper Cabling System Name Coding VP CA FU 54 XX X X STRUCTURE CATEGORY/PAIR RATING COLOR LENGTH FU=F/UTP 54=CAT 5e, 4 Pair CR=CMR B=Blue 3=305m CM=CM G=Grey LS=LSZH K=Black PV=PVC P=Purple SU=SF/UTP CAT 5e Copper Cabling System TYPE CA=Copper Cable PE=LDPE(outdoor) Ordering Information Part No. Description VPCAFU54CRB3 CAT 5e F/UTP Shielded Cable, CMR, Blue, 305m/Drum VPCAFU54CRG3 CAT 5e F/UTP Shielded Cable, CMR, Grey, 305m/Drum VPCAFU54CMB3 CAT 5e F/UTP Shielded Cable, CM, Blue, 305m/Drum VPCAFU54CMG3 CAT 5e F/UTP Shielded Cable, CM, Grey, 305m/Drum VPCAFU54PVB3 CAT 5e F/UTP Shielded Cable, PVC, Blue, 305m/Drum VPCAFU54PVG3 CAT 5e F/UTP Shielded Cable, PVC, Grey, 305m/Drum VPCAFU54LSP3 CAT 5e F/UTP Shielded Cable, LSZH, Purple, 305m/Drum VPCAFU54PEK3 CAT 5e F/UTP Shielded Cable, PE, Black, 305m/Drum VPCASU54CRB3 CAT 5e SF/UTP Shielded Cable, CMR, Blue, 305m/Drum VPCASU54CRG3 CAT 5e SF/UTP Shielded Cable, CMR, Grey, 305m/Drum VPCASU54CMB3 CAT 5e SF/UTP Shielded Cable, CM, Blue, 305m/Drum VPCASU54CMG3 CAT 5e SF/UTP Shielded Cable, CM, Grey, 305m/Drum VPCASU54PVB3 CAT 5e SF/UTP Shielded Cable, PVC, Blue,305m/Drum VPCASU54PVG3 CAT 5e SF/UTP Shielded Cable, PVC, Grey,305m/Drum VPCASU54LSP3 CAT 5e SF/UTP Shielded Cable, LSZH, Purple,305m/Drum VPCASU54PEK3 CAT 5e SF/UTP Shielded Cable, PE, Black,305m/Drum www.vivanco.asia 029 Copper Cabling System CAT5e Keystone Jack, Shielded Electrical Characteristics DC 1000V(AC750V) 1min, no breakdown and Dielectric Strength arcing phenomena DC Resistance(Ω) ≤300 mΩ Connecting Reactance(Ω) Insulation Resistance(Ω) ≤20mΩ Under normal atmospheric pressure ≥500 mΩ Compliance • ANSI/TIA 568-C.2 Category 5e • ISO/IEC 11801 Class D Physical Characteristics Phosphor bronze IDC Phosphor bronze with RJ45 Pin 50μm gold plating Plug Insertion ≥1000 times IDC Insertion Life Span ≥250 times AWG 22~26AWG Features & Benefits • 360° fully shielded design effectively prevents EMI • Best impedance matching • Gold plated, to prevent surface oxidation and improve the performance of the contact so as to ensure the performance and service life VC CJ S T568A/T568B Wiring N F 5 S TYPE STRUCTURE SHUTTER STYLE CATEGORY LOLOR CJ=Copper Jack S=Shielded N=Non-shuttered F=Flat 5=CAT 5e S=Silver CAT 5e Shielded RJ45 Keystone Jack 030 www.vivanco.asia CAT 6A Copper Cabling System Copper Cabling System CAT5e Patch Panel, Shielded CAT 6 Copper Cabling System Compliance Electrical Characteristics • ANSI/TIA 568-C.2 Category 5e • ISO/IEC 11801 Class D DC 1000V(AC750V) 1min, no breakdown and Dielectric Strength arcing phenomena DC Resistance(Ω) ≤300 mΩ Connecting Reactance(Ω) • Adopt 24 port PCB board design to prevent the dust and easily connect the whole panel to the earth • Rear cable manager for cable management • Back-end cable bracket guarantees the cable inserted vertically • Standard 19”, widely used industry standard CAT 5e Copper Cabling System Features & Benefits ≤20mΩ Under normal atmospheric Insulation Resistance(Ω) pressure ≥500 mΩ Physical Characteristics IDC Phosphor bronze Phosphor bronze with RJ45 Pin 50μm gold plating Plug Insertion ≥1000 times IDC Insertion Life Span ≥250 times AWG 22~26AWG T568A/T568B Wiring S VC CP X 5 XX X A TYPE STRUCTURE STYLE CATEGORY PORT HEIGHT INSTALLATION CP=Copper Patch Panel S=Shielded F=Flat 5=CAT 5e 24=24 Port 1=1U A=Easy Installation G=Group CAT 5e Shielded 24 Port Patch Panel, 1U CAT 5e Shielded 24 Port Patch Panel, 1U (8 port as one unit) CAT 5e Shielded 24 Port Patch Panel, 1U (easy installation) CAT 5e Shielded 24 Port Patch Panel, 1U (8 port as one unit, easy installation) www.vivanco.asia 031 Copper Cabling System CAT5e Patch Cord, Shielded Features & Benefits •Suitable for 1000Base-T, Ethernet application •Each patch cord is 100% performance tested •Choice of lengths and colors •Up down Pin improves NEXT performance •25 years system warranty Compliance •ISO/IEC 11801 •ANSI/TIA/EIA-568-C.2 •IEC 61156-5 Physical Performance Insulation HDPE RJ45 Pin Gold-plating Plug Insertion Life Span ≥750 times Conductor Cable Construction •F/UTP, SF/UTP •26AWG Stranded, 7*0.20mm Operating Temperature -20~60°C VC CC XU 5R XX X X TYPE STRUCTURE CATEGORY/CONDUCTOR RATING COLOR LENGTH CC=Copper Cord FU=F/UTP 5R=CAT 5e, Stranded CR=CMR B=Blue 1=1m CM=CM G=Grey 2=2m LS=LSZH R=Red 3=3m PV=PVC Y=Yellow 5=5m SU=SF/UTP 032 www.vivanco.asia CAT 6A Copper Cabling System Copper Cabling System CAT5e Patch Cord, Shielded Red Blue Yellow Jacket VCCCFU5RCRG1 VCCCFU5RCRR1 VCCCFU5RCRB1 VCCCFU5RCRY1 CMR VCCCFU5RCMG1 VCCCFU5RCMR1 VCCCFU5RCMB1 VCCCFU5RCMY1 CM VCCCFU5RLSG1 VCCCFU5RLSR1 VCCCFU5RLSB1 VCCCFU5RLSY1 LSZH VCCCFU5RPVG1 VCCCFU5RPVR1 VCCCFU5RPVB1 VCCCFU5RPVY1 PVC VCCCFU5RCRG2 VCCCFU5RCRR2 VCCCFU5RCRB2 VCCCFU5RCRY2 CMR VCCCFU5RCMG2 VCCCFU5RCMR2 VCCCFU5RCMB2 VCCCFU5RCMY2 CM VCCCFU5RLSG2 VCCCFU5RLSR2 VCCCFU5RLSB2 VCCCFU5RLSY2 LSZH VCCCFU5RPVG2 VCCCFU5RPVR2 VCCCFU5RPVB2 VCCCFU5RPVY2 PVC VCCCFU5RCRG3 VCCCFU5RCRR3 VCCCFU5RCRB3 VCCCFU5RCRY3 CMR VCCCFU5RCMG3 VCCCFU5RCMR3 VCCCFU5RCMB3 VCCCFU5RCMY3 CM VCCCFU5RLSG3 VCCCFU5RLSR3 VCCCFU5RLSB3 VCCCFU5RLSY3 LSZH VCCCFU5RPVG3 VCCCFU5RPVR3 VCCCFU5RPVB3 VCCCFU5RPVY3 PVC VCCCFU5RCRG5 VCCCFU5RCRR5 VCCCFU5RCRB5 VCCCFU5RCRY5 CMR VCCCFU5RCMG5 VCCCFU5RCMR5 VCCCFU5RCMB5 VCCCFU5RCMY5 CM VCCCFU5RLSG5 VCCCFU5RLSR5 VCCCFU5RLSB5 VCCCFU5RLSY5 LSZH VCCCFU5RPVG5 VCCCFU5RPVR5 VCCCFU5RPVB5 VCCCFU5RPVY5 PVC VCCCSU5RCRG1 VCCCSU5RCRR1 VCCCSU5RCRB1 VCCCSU5RCRY1 CMR VCCCSU5RCMG1 VCCCSU5RCMR1 VCCCSU5RCMB1 VCCCSU5RCMY1 CM VCCCSU5RLSG1 VCCCSU5RLSR1 VCCCSU5RLSB1 VCCCSU5RLSY1 LSZH VCCCSU5RPVG1 VCCCSU5RPVR1 VCCCSU5RPVB1 VCCCSU5RPVY1 PVC VCCCSU5RCRG2 VCCCSU5RCRR2 VCCCSU5RCRB2 VCCCSU5RCRY2 CMR VCCCSU5RCMG2 VCCCSU5RCMR2 VCCCSU5RCMB2 VCCCSU5RCMY2 CM VCCCSU5RLSG2 VCCCSU5RLSR2 VCCCSU5RLSB2 VCCCSU5RLSY2 LSZH VCCCSU5RPVG2 VCCCSU5RPVR2 VCCCSU5RPVB2 VCCCSU5RPVY2 PVC VCCCSU5RCRG3 VCCCSU5RCRR3 VCCCSU5RCRB3 VCCCSU5RCRY3 CMR VCCCSU5RCMG3 VCCCSU5RCMR3 VCCCSU5RCMB3 VCCCSU5RCMY3 CM VCCCSU5RLSG3 VCCCSU5RLSR3 VCCCSU5RLSB3 VCCCSU5RLSY3 LSZH VCCCSU5RPVG3 VCCCSU5RPVR3 VCCCSU5RPVB3 VCCCSU5RPVY3 PVC VCCCSU5RCRG5 VCCCSU5RCRR5 VCCCSU5RCRB5 VCCCSU5RCRY5 CMR VCCCSU5RCMG5 VCCCSU5RCMR5 VCCCSU5RCMB5 VCCCSU5RCMY5 CM VCCCSU5RLSG5 VCCCSU5RLSR5 VCCCSU5RLSB5 VCCCSU5RLSY5 LSZH VCCCSU5RPVG5 VCCCSU5RPVR5 VCCCSU5RPVB5 VCCCSU5RPVY5 PVC Length(m) 1 CAT 5e Copper Cabling System F/UTP Grey 2 3 5 1 2 SF/UTP www.vivanco.asia CAT 6 Copper Cabling System Ordering Information 3 5 033 Copper Cabling System CAT 5e Unshielded System Solutions Vivanco CAT 5e end to end unshielded solution comprises of cable, patch panel, patch cords and information outlets/jacks. The CAT 5e system offers superior electrical performance meeting Class D requirements for all applications CAT 5e Cable • Unique unshielded design • 24 AWG • Independently verified by 3rd party test labs • Exceed ISO/IEC 11801, IEC 61156-5, ANSI/TIA/EIA-568-C.2 Class D standards • Excellent margin Patch Panel •Exceed all TIA 568-C.2 component requirement • Modular design • Tower IDC design ensures separation of pairs for easy installation • Choose from 24 ports (1U) or 48 ports (2U) Modular Jack •Exceed all TIA 568-C.2 component requirement • Tower IDC design ensures separation of pairs for easy installation • 180° IDC • Choose jack color depending on application Patch Cords •Exceed all TIA 568-C.2 component requirement • Strain relief boots ensures long term performance • Snagless design with choice of lengths and colors • 26 AWG conductors offers flexibility during usage 034 www.vivanco.asia CAT 6A Copper Cabling System Copper Cabling System CAT5e U/UTP 4 Pair Cable, Unshielded CAT 6 Copper Cabling System Electrical Performance Conductor Jacket <9.38Ω/100m Operating Capacitance ≤5.6nF/100m Unbalanced Capacitance ≤330pF/100m Impedance (ohms) CAT 5e Copper Cabling System Insulation Direct Current Resistance of Each Conductor 1~100MHz 100±15% Rip cord 70% NVP Propagation Delay Compliance •ISO/IEC 11801 • ANSI/TIA/EIA-568-C.2 • IEC 61156-5 ≤45ns Physical Performance Construction 110N Tensile •U/UTP •24 AWG, solid bare copper • Jacket diameter: 5.1±0.3mm 10 times max jacket diameter Min. Bend Radius Installation Temperature 0~50°C (32~122°F) Storage Temperature -20~75°C (-4~167°F) Operating Temperature -20~60°C (-4~140°F) Features & Benefits •Frequency 1-100MHz, extended to 350MHz • Suitable for 1000Base-T, Ethernet application • 25 years system warranty VC CA UU 54 XX X X TYPE STRUCTURE STYLE RATING COLOR LENGTH CA = Copper Cable UU=U/UTP 54=CAT 5e,4 Pair CR=CMR B=Blue 3 = 305m CM=CM G=Grey LS=LSZH K=Black PV=PVC P=Purple PE=LDPE(outdoor) Part No. Description VCCAUU54CRB3 CAT 5e U/UTP Unshielded Cable, CMR, Blue, 305m/Pull box VCCAUU54CRG3 CAT 5e U/UTP Unshielded Cable, CMR, Grey, 305m/Pull box VCCAUU54CMB3 CAT 5e U/UTP Unshielded Cable, CM, Blue, 305m/Pull box VCCAUU54CMG3 CAT 5e U/UTP Unshielded Cable, CM, Grey, 305m/Pull box VCCAUU54PVB3 CAT 5e U/UTP Unshielded Cable, PVC, Blue, 305m/Pull box VCCAUU54PVG3 CAT 5e U/UTP Unshielded Cable, PVC, Grey, 305m/Pull box VCCAUU54LSP3 CAT 5e U/UTP Unshielded Cable, LSZH, Purple, 305m/Pull box VCCAUU54PEK3 CAT 5e U/UTP Unshielded Cable, PE, Black, 305m/Pull box www.vivanco.asia 035 Copper cabling system CAT5e Keystone Jack, Unshielded Electrical Characteristics DC 1000V(AC750V) 1min, no breakdown and Dielectric Strength arcing phenomena DC Resistance(Ω) ≤300 mΩ Connecting Reactance(Ω) Insulation Resistance(Ω) ≤20mΩ Under normal atmospheric pressure ≥500 mΩ Compliance •ANSI/TIA/EIA-568-C.2 Category 5E •ISO 11801 2 Class D Physical Characteristics IDC Phosphor bronze Phosphor bronze with RJ45 Pin Features & Benefits •Best impedance matching •Separation frame design facilitates the separation of the conductor •Connecting points adopt the special pin to effectively reduce NEXT •Compatible with all Vivanco faceplate and unshielded patch panel • With the transparent cable cover to prevent the wire falling down VC CJ U 50μm gold plating Plug Insertion ≥1000 times IDC Insertion Life Span ≥250 times AWG 22~26AWG T568A/T568B Wiring N F 5 X TYPE STRUCTURE SHUTTER STYLE CATEGORY LOLOR CJ=Copper Jack U=Unshielded N=Non-shuttered F=Flat 5=CAT 5e W=White K=Black Ordering Information 036 Part No. Description VCCJUNF5W CAT 5e Unshielded RJ45 Keystone Jack (White) VCCJUNF5K CAT 5e Unshielded RJ45 Keystone Jack (Black) www.vivanco.asia CAT 6A Copper Cabling System Copper cabling system CAT5e 24 Port Patch Panel, Unshielded CAT 6 Copper Cabling System Compliance Electrical Characteristics • ANSI/TIA/EIA-568-C.2 Category 5e • ISO/IEC 11801 Class D DC 1000V(AC750V) 1min, no breakdown and Dielectric Strength arcing phenomena Features & Benefits DC Resistance(Ω) ≤300 mΩ Connecting Reactance(Ω) CAT 5e Copper Cabling System • Standard 19”, widely used industry standard • Plastic panel, the overall structure of the steel base plate to ensure that the mechanical strength of the product • A dust cover for the jack effectively prevents the impact of dust on the link performance • Each jack can be individually disassembled • Offer 24 port (1U) and 48 port (2U) type ≤20mΩ Under normal atmospheric Insulation Resistance(Ω) pressure ≥500 mΩ Physical Characteristics Phosphor bronze IDC Phosphor bronze with RJ45 Pin 50μm gold plating Plug Insertion ≥1000 times IDC Insertion Life Span ≥250 times AWG 22~26AWG Wiring VC CP U F T568A/T568B 5 XX X A TYPE STRUCTURE STYLE CATEGORY PORT HEIGHT INSTALLATION CP=Copper Patch Panel U=Unshielded F=Flat 5=CAT 5e 24=24 Port 1=1U A=Easy Installation 48=48 Port 2=2U Part No. Description VCCPUF5241 CAT 5e 24 port Unshielded Patch Panel, 1U VCCPUF5482 CAT 5e 48 port Unshielded Patch Panel, 2U VCCPUF5241A CAT 5e 24 port Unshielded Patch Panel, 1U (Easy installation) www.vivanco.asia 037 Copper Cabling System CAT5e Patch Cord, Unshielded Features & Benefits • Suitable for 1000Base-T, Ethernet application • Each patch cord is 100% performance tested • Choice of lengths and colors • 25 years system warranty Physical Performance Compliance Insulation • ISO/IEC 11801 • ANSI/TIA/EIA-568-C.2 • IEC 61156-5 Cable Construction HDPE RJ45 Pin Gold-plating Plug Insertion Life Span ≥750 times Conductor •U/UTP • 24 AWG Stranded, 7*0.16mm Operating Temperature -20~60°C Name Coding VC CC UU 5R XX X X TYPE STRUCTURE CATEGORY/CONDUCTOR RATING COLOR LENGTH CC=Copper Cord UU=U/UTP 5R=CAT 5e, Stranded CR=CMR B = Blue 1=1m CM=CM G = Grey 2=2m LS=LSZH R=Red 3=3m PV=PVC Y=Yellow 5=5m Grey Red Blue Yellow Jacket VCCCUU5RCRG1 VCCCUU5RCRR1 VCCCUU5RCRB1 VCCCUU5RCRY1 CMR VCCCUU5RCMG1 VCCCUU5RCMR1 VCCCUU5RCMB1 VCCCUU5RCMY1 VCCCUU5RLSG1 VCCCUU5RLSR1 VCCCUU5RLSB1 VCCCUU5RLSY1 CM LSZH VCCCUU5RPVG1 VCCCUU5RPVR1 VCCCUU5RPVB1 VCCCUU5RPVY1 PVC CMR VCCCUU5RCRG2 VCCCUU5RCRR2 VCCCUU5RCRB2 VCCCUU5RCRY2 VCCCUU5RCMG2 VCCCUU5RCMR2 VCCCUU5RCMB2 VCCCUU5RCMY2 CM VCCCUU5RLSY2 LSZH VCCCUU5RLSG2 VCCCUU5RLSR2 VCCCUU5RLSB2 VCCCUU5RPVG2 VCCCUU5RPVR2 VCCCUU5RPVB2 VCCCUU5RPVY2 PVC VCCCUU5RCRG3 VCCCUU5RCRR3 VCCCUU5RCRB3 VCCCUU5RCRY3 CMR VCCCUU5RCMG3 VCCCUU5RCMR3 VCCCUU5RCMB3 VCCCUU5RCMY3 CM VCCCUU5RLSG3 VCCCUU5RLSR3 VCCCUU5RLSB3 VCCCUU5RLSY3 LSZH VCCCUU5RPVG3 VCCCUU5RPVR3 VCCCUU5RPVB3 VCCCUU5RPVY3 PVC VCCCUU5RCRG5 VCCCUU5RCRR5 VCCCUU5RCRB5 VCCCUU5RCRY5 CMR VCCCUU5RCMG5 VCCCUU5RCMR5 VCCCUU5RCMB5 VCCCUU5RCMY5 CM VCCCUU5RLSG5 VCCCUU5RLSR5 VCCCUU5RLSB5 VCCCUU5RLSY5 LSZH VCCCUU5RPVG5 VCCCUU5RPVR5 VCCCUU5RPVB5 VCCCUU5RPVY5 PVC 038 Length(m) 1 2 3 5 www.vivanco.asia CAT 6A Copper Cabling System Copper Cabling System Voice System Solutions CAT 6 Copper Cabling System INTRODUCTION CAT 5e Copper Cabling System Voice System Solutions Vivanco offers a versatile CAT 5e 110 based system to complement its patch panel system for voice and high speed applications, an end to end solution comprising multi pair cable from 4 pair, 25pair, 50 pair and 100 pair, 110 base unit for minimum of 100 pair up to 200 pair available in rack mount or wall mount versions, 4 and 5 pair 110 connector’s installed along with 110 to 110 & 110 to RJ45 patch cords in various lengths options gives unmatched price performance advantage for the user. Cable • Choice of using standard 4 pair, 25 pair, 50 pair CAT 5e • Choose from 2 pair to 50 pair in CAT 3 standard • Excellent performance and electrical characteristics • Suitable for voice and data application 110 Base Unit • Available in 100 pair and 200 pair • Choice between rack mount and wall mount versions (with or without legs) • Comes with 4 and 5 pair 110 connectors • CAT 5e compliant 110 Connector • Dual IDC connects between IDC and 110 patch cord • Available in 4 and 5 pair block • Easy color coding for identification and maintenance 110 Patch Cord • Excellent transmission characteristics • Choice of 110 to 110 and 110 to RJ45 options depending on application • Choice of lengths and no of pairs www.vivanco.asia 039 Copper Cabling System CAT5e U/UTP 25 Pair Cable, Unshielded Features & Benefits •Suitable for 1000Base-T, Ethernet application •25 years system warranty Electrical Performance Jacket Conductor Direct Current Resistance of Each each Conductor <9.38Ω/100m Operating Capacitance ≤5.6nF/100m Unbalanced Capacitance ≤330pF/100m Filling Insulation Pet+yarn Impedance (ohms) 1-100MHz 100±15% Propagation Delay ≤45ns Rip cord Physical Performance Compliance 15 times max jacket diameter Min. Bend Radius •ANSI/ICEA S-90-661 •TIA/EIA-568-C.2 Installation Temperature Construction Storage Temperature •U/UTP •Jacket diameter: 11±0.5 mm Operating Temperature 0~50°C (32~122°F) -20~75°C (-4~167°F) -20~60°C (-4 to 140°F) Name Coding VC CA UU 52 XX X X TYPE STRUCTURE SHUTTER RATING COLOR LENGTH CA=Copper Jack UU=U/UTP 52=CAT 5e, 25 Pair CR=CMR G = Grey 3 = 305m CM=CM P = Purple LS=LSZH PV=PVC Ordering Information 040 Part No. Description VCCAUU52CRG3 CAT 5e U/UTP 25 Pair Backbone Cable, CMR, Grey, 305m/Drum VCCAUU52CMG3 CAT 5e U/UTP 25 Pair Backbone Cable, CM, Grey, 305m/Drum VCCAUU52PVG3 CAT 5e U/UTP 25 Pair Backbone Cable, PVC, Grey, 305m/Drum VCCAUU52LSP3 CAT 5e U/UTP 25 Pair Backbone Cable, LSZH, Purple, 305m/Drum www.vivanco.asia CAT 6A Copper Cabling System Copper Cabling System CAT3 U/UTP 25, 50 Pair Cable, Unshielded CAT 6 Copper Cabling System Features & Benefits •Suitable for Voice application •25 years system warranty Electrical Performance Sub-unit Non-woven+yarn Operating Capacitance ≤5.6nF/100m Unbalanced Capacitance ≤330pF/100m Impedance (ohms) 1-100MHz 100±15% Propagation Delay ≤45ns Voice System Solutions Jacket <9.38Ω/100m CAT 5e Copper Cabling System Conductor Insulation Direct Current Resistance of each Conductor Rip cord Compliance Physical Performance •ANSI/ICEA S-90-661 15 times max jacket diameter Min. Bend Radius •TIA/EIA-568-C.2 Installation Temperature Construction •U/UTP Storage Temperature • 9.0±0.5 mm 25 pair;12.0±0.5mm 50 pair max jacket diameter Operating Temperature 0~50°C (32~122°F) -20~75°C (-4~167°F) -20~60°C (-4 to 140°F) VC CA UU 3X XX XX X X TYPE CA = Copper Cable STRUCTURE CATEGORY / PAIR RATING COLOR LENGTH UU=U/UTP 32=CAT 3, 25 Pair CR=CMR G=Gery 3=305m 35=CAT 3, 50 Pair CM=CM P=Purple LS=LSZH PV=PVC Ordering Information Part No. Description VCCAUU32CMG3 CAT 3 U/UTP 25 Pair Backbone Cable, CM, Grey, 305m/Drum VCCAUU32PVG3 CAT 3 U/UTP 25 Pair Backbone Cable, PVC, Grey, 305m/Drum VCCAUU32LSP3 CAT 3 U/UTP 25 Pair Backbone Cable, LSZH, Purple, 305m/Drum VCCAUU32PEK3 CAT 3 U/UTP 25 Pair Backbone Cable, PE, Black, 305m/Drum VCCAUU35CMG3 CAT 3 U/UTP 50 Pair Backbone Cable, CM, Grey, 305m/Drum VCCAUU35PVG3 CAT 3 U/UTP 50 Pair Backbone Cable, PVC, Grey, 305m/Drum VCCAUU35LSP3 CAT 3 U/UTP 50 Pair Backbone Cable, LSZH, Purple, 305m/Drum VCCAUU35PEK3 CAT 3 U/UTP 50 Pair Backbone Cable, PE, Black, 305m/Drum www.vivanco.asia 041 Copper Cabling System CAT 3 U/UTP 2 Pair Cable, Unshielded Features & Benefits •Smaller diameter, not easy to lay and stuck during installation •Ink-jet mark with the meter length for accuracy and easy usage •Provide cable marking to reduce waste Electrical Performance Conductor Insulation Direct Current Resistance of each Conductor <14.8Ω/100m Operating Capacitance ≤5.6nF/100m Unbalanced Capacitance ≤330pF/100m Jacket Rip cord Impedance (ohms) 1-16MHz 100±15% Propagation Delay ≤45ns Compliance •ISO/IEC 11801:2008 •TIA/EIA-568-B.2 Physical Performance 10 times max jacket diameter Min. Bend Radius Installation Temperature Construction Storage Temperature • 26 AWG, solid bare copper(99.9%) • Jacket diameter: 3.8±0.2mm Operating Temperature 0~50°C (32~122°F) -20~75°C (-4~167°F) -20~60°C (-4 to 140°F) Name Coding VC CA UU 34 TYPE STRUCTURE CATEGORY/PAIR RATING CA=Copper Cable UU=U/UTP 34=CAT 3, 2 Pair PV=PVC VCCAVV34PVG3 042 XX X X COLOR G=Grey LENGTH 3=305m CAT3 U/UTP 2 Pair Cable, Unshielded, Grey www.vivanco.asia CAT 6A Copper Cabling System Copper Cabling System CAT3 U/UTP Keystone Jack CAT 6 Copper Cabling System Electrical Characteristics 1.5 Amp Rated Current Under normal atmospheric Insulation Resistance(Ω) pressure ≥500 mΩ CAT 5e Copper Cabling System Compliance Voice System Solutions •ISO/IEC 11801:2008 •ANSI/TIA 568-B.2 •YD/T 926.3-2009 Physical Characteristics IDC Phosphor bronze Phosphor bronze with RJ45 Pin 50μm gold plating Features & Benefits •Gold-plated pin improves the performance ,prevents surface, oxidation and prolongs service life •Special cable protection cover prevents the cable loss and the dust •45 degrees of crossover design makes the conductor clamping firmer which provides clear line sequence identification, convenient for construction and maintenance Plug Insertion ≥1000 times IDC Insertion Life Span ≥250 times AWG 22~26AWG Operating Temperature -25°C~60°C Name Coding VC CJ U N F 3 X TYPE STRUCTURE SHUTTER STYLE CATEGORY COLOR CA = Copper Jack U=U/UTP N=Non-shuttered F=Flat 3=CAT 3 W=White VCCJUNF3W www.vivanco.asia 043 Copper Cabling System Voice Patch Panel, Unshielded Electrical Characteristics Features and Benefits: • Offer RJ45 port and support CAT 6 and CAT 5e patch cord • Each jack can be individually disassembled • Each jack with a cover to prevent the dust • Offer 25 port (1U) and 50 port (1U) type • Standard 19”, widely used industry standard Dielectric Strength DC 1000V(AC750V) 1min, no breakdown and arcing phenomena DC Resistance(Ω) ≤300 mΩ Connecting Reactance(Ω) ≤20mΩ Insulation Resistance(Ω) Under normal atmospheric ≥500 mΩ Physical Characteristics IDC Phosphor bronze Phosphor bronze with 50μm gold Plating RJ45 Pin Plug Insertion ≥1000 times IDC Insertion Life Span ≥250 times AWG 22~26AWG T568A/T568B Wiring VP CP U TYPE CP=Copper Patch Panel F 3 25 X A STRUCTURE STYLE CATEGORY PORTS HEIGHT INSTALLATION U=Unshielded F=Flat 3=CAT 3 25=25 Port 1=1U A=Easy Installation 50=50 Port 2=2U Ordering Information 044 Part No. Description VCCPUF3251 25 Port Voice Patch Panel, 1U VCCPUF3502 50 Port Voice Patch Panel, 2U VCCPUF3251A 25 Port Voice Patch Panel (Easy Installation), 1U www.vivanco.asia CAT 6A Copper Cabling System Copper Cabling System 110 Base Unit CAT 6 Copper Cabling System Features and Benefits • Use 5 pair punching tool to facilitate the installation time and cost • Support 4 pair and 5 pair connector • Used for 110 to 110 or 110 to RJ45 system CAT 5e Copper Cabling System Electrical Characteristics DC 1000V(AC750V) 1min, Dielectric Strength no breakdown and arcing phenomena Voice System Solutions Connecting Reactance(Ω) ≥200mΩ Physical Characteristics 22~26AWG AWG IDC Insertion Life Span ≥200 5 VC 110B X X A TYPE CATEGORY TYPE PAIR INSTALLATION 110B=110 Base Unit 5=CAT 5e W= Wall Mount With Leg 5= 50 Pair A= Easy Installation N= Wall Mount Without Leg 1=100 Pair R= Rack Mount 2=200 Pair Ordering Information Part No. Description VC110B5W5 50 Pair CAT 5e Unshielded 110 Kit With Leg VC110B5W1 100 Pair CAT 5e Unshielded 110 Kit With Leg VC110B5N5 50 Pair CAT 5e Unshielded 110 Kit Without Leg VC110B5N1 100 Pair CAT 5e Unshielded 110 Kit Without Leg VC110B5R1 100 Pair CAT 5e Unshielded 110 Kit (19” rack type) VC110B5R2 200 Pair CAT 5e Unshielded 110 Kit (19” rack type) VC110B5R1A 100 Pair CAT 5e Unshielded 110 Kit (19” rack type, easy installation) www.vivanco.asia 045 Copper Cabling System 110 Connecting Block Features and Benefits • Support 110 patch panel and 110 patch cord connection • Color code for easy identification while terminating • Compatible with different wiring tool Electrical Characteristics DC 1000V(AC750V) 1min, no breakdown and Dielectric Strength arcing phenomena DC Resistance(Ω) ≤300 mΩ Connecting Reactance(Ω) Insulation Resistance(Ω) ≤20mΩ Under normal atmospheric ≥500 mΩ Physical Characteristics Phosphor bronze IDC IDC Insertion Life Span ≥250 times AWG 22~26AWG VC 110C 5 X TYPE CATEGORY PAIR 110C=110 Connecting Block 5=CAT 5e 4= 4 Pair 5= 5 Pair Ordering Information 046 Part No. Description VC110C54 4 Pair Connecting Block VC110C55 5 Pair Connecting Block www.vivanco.asia CAT 6A Copper Cabling System Copper Cabling System 110 Patch Cord, Unshielded CAT 6 Copper Cabling System Features and Benefits X Voice System Solutions VP 110P 5 CAT 5e Copper Cabling System • 110-110,110-RJ45 patch cord demonstrates excellent transmission performance, suitable for all audio communication systems, multimedia and other high-speed applications • Applied with110 kit conveniently and prolong the service life of 110 kit • A seamless connection between the 110 kit and RJ45 patch panel • IDC insertion life span >200 times X X TYPE CATEGORY TYPE PAIR LENGTH 110P=110 Patch Cord 5= CAT 5e A=110-110 1=1 Pair 1=1m B=110-RJ45 2=2 Pair 2=2m 3=3 Pair 3=3m Ordering Information Part No. Description VP110P5A11 110-110 Patch Cord ,1 Pair,1m VP110P5A12 110-110 Patch Cord ,1 Pair,2m VP110P5A21 110-110 Patch Cord ,2 Pair,1m VP110P5A22 110-110 Patch Cord ,2 Pair,2m VP110P5B11 110-RJ45 Patch Cord ,1 Pair,1m VP110P5B12 110-RJ45 Patch Cord ,1 Pair,2m VP110P5B21 110-RJ45 Patch Cord ,2 Pair,1m VP110P5B22 110-RJ45 Patch Cord ,2 Pair,2m VP110P5B41 110-RJ45 Patch Cord ,4 Pair,1m VP110P5B42 110-RJ45 Patch Cord ,4 Pair,2m www.vivanco.asia 047 Fibre Cabling System VIVANCO offers fibre cabling solution from server room to desk outlet or campus wide and data centre for customer requirement. • Fibre Cabling System ---------------------------------------------------------049 • Optical Accessories -----------------------------------------------------------076 www.vivanco.asia CAT 6A Copper Cabling System Fibre Cabling System Optical Fibre Solutions CAT 6 Copper Cabling System INTRODUCTION Cable • Standards based cable complies to ISO/IEC 11801/2008 • Choose between OS1, OS2, OM2, OM3 and OM4 • Complete FTTH solution starts with 2 pair bend Insensitive Patch Cord • Fully compliant with all relevant standards • Choice of connectors and lengths • Manufactured in clean room environment • SM, MM available Fibre Cabling System • SM and MM fibre including bend insensitive fibre for FTTH • Fibre count from 2 core up to 144 core • High density panels up to 144 ports • MPO panel for data center • Pre-connectorised connector with option to chose APC • Custom length and jacket patch cords Connector • Precisely machined ceramic ferrule with stringent tolerances • Fully complies with all relevant standards • Available in SM and MM • Choice of connectors from SC, ST, LC, MTRJ, FC etc Voice System Solutions Vivanco offers wide range of fibre solution to meet the needs of installers and customers alike with great features and benefits for campus network or data centre environment or fibre to the home. Depending on application Vivanco has standards compliant indoor and outdoor cable to suit every environment as well as bend insensitive fibre to the home. these are complimented by its range of fibre panels (rack or wall mount), fusion splice tray, connectors, pigtails and patch cords. MTO solution from Vivanco ensures faster deployment of physical infrastructure in the data centre environment. CAT 5e Copper Cabling System Panel • Unique design make maintenance easier • 19 inch rack mount or wall mount • Fixed to drawer type • 24 to 144 port available • Choose from SC, LC, FC, MTRJ • Splice tray standard accessory with panel MTO Panel • Standard 19 inch format • Versatile fibre ports from 12 to 72 • Use LC MPO Adaptor • Provide 12 or 24 port LC • Light weight MPO Patch Cord • 12 and 24 Core MPO to MPO extenders • 12 and 24 port MPO to LC patchcords • Choose from 2, 3 and 5m lengths • Available in SM and MM www.vivanco.asia 049 Fibre Cabling System Indoor Tight Buffer Optical Fibre Cable, Single Mode Compliance • ISO/IEC 11801:2008 • ANSI/TIA/EIA-568-C.3 • TIA-598-C • EN50173:2002 • TIA/EIA-526-7 • ITU G652D Jacket Tight buffered Optical fibre Aramid yam strength member Features & Benefits • Singlemode has the advantage of low attenuation, low dispersion and low polarization mode dispersion • High-strength aramid reinforcement, optical fibre without tensile strain to ensure long-term stability of optical fibre ransmission characteristics • Light weight, high degree of flexibility, small bending radius, stress, strain and excellent performance • Can be installed in limited wall space, roof and pipe tangle free Cable Construction Cable Type G.652D Jacket Color Yellow LSZH Jacket OFN/OFNR or IEC 60332-1 Flame-retardant Covering Color Short Term/ Long Term Pull Tension (N) Short Term/ Long Term Crush Tension (N) Dynamic/Static Minimum Bend Radius (D) Operating Temperature 050 Blue, orange, green, brown, gray, white, red, black, yellow, purple, pink, turquoise ≤4 core 220/70 ≤12 core 660/200 1000/300 20/10 -20℃~60℃ www.vivanco.asia CAT 6A Copper Cabling System Fibre Cabling System Indoor Tight Buffer Optical Fibre Cable, Single Mode CAT 6 Copper Cabling System Optical Performance Wavelength (nm) Attenuation (Max.) (dB/km) 1310 1550 ≤0.36 ≤0.22 ≤1260 Cutoff Wavelength (λcc) Temperature and Attenuation (dB/km) Zero Dispersion Slope (ps/nm² ×km) CAT 5e Copper Cabling System ≤0.1 1300nm-1324nm; ≤0.092 Voice System Solutions VC FA N T N XX CATEGORY SHEATH TYPE ARMOR TYPE N=Indoor T=Tight Buffered N=N/A CORES NO. 01=1 FIBRE TYPE JACKET S2=OS2 FN=OFN 02=2 NR =OFNR 04=4 LS=LSZH (60332-1) Fibre Cabling System TYPE FA=Fibre Cable S2 XX 06=6 08=8 12=12 Ordering Information Part No. Description VCFANTNxxS2LS Single Mode X Optical Fibre Cable, Yellow, LSZH VCFANTNxxS2FN Single Mode X Optical Fibre Cable, Yellow, OFN VCFANTNxxS2NR Single Mode X Optical Fibre Cable, Yellow, OFNR Note: xx denotes core number www.vivanco.asia 051 Fibre Cabling System Indoor Tight Buffer Optical Fibre Cable, Multi Mode Compliance • ISO/IEC 11801:2008 • ANSI/EIA-568-C.3 Jacket Tight buffered Optical fibre Aramid yam strength member Features & Benefits • Multimode has the precise refractive index distribution curve and eliminate the phenomenon of the central recess of the multimode optical fibre • High-strength aramid reinforcement, ensure no tensile stree and long-term stability of optical fibre transmission characteristics • Light weight, high degree of flexibility, small bending radius, stress, strain and excellent performance • Can be installed in limited wall space, roof and pipe tangle free Cable Construction Cable Type OM1, OM2, OM3, OM4 OM1, OM2 Jacket Color OM3 Aqua OM4 Violet Jacket LSZH Flame-retardant Covering Color Short Term/ Long Term Pull Tension (N) Short Term/ Long Term Crush Tension (N) Dynamic / Static Minimum Bend Radius (D) Operating Temperature 052 Orange OFN/OFNR or IEC 60332-1 Blue, orange, green, brown, gray, white, red, black, yellow, purple, pink, turquoise ≤4 core 220/70 ≤12 core 660/200 1000/300 20/10 -20℃~60℃ www.vivanco.asia CAT 6A Copper Cabling System Fibre Cabling System Indoor Tight Buffer Optical Fibre Cable, Multi Mode CAT 6 Copper Cabling System Optical Performance Wavelength (nm) Attenuation (Max.) (dB/km) 850 1300 ≤3.5 ≤1.2 Zero Dispersion Slope (ps/nm²×km) ≤0.2 CAT 5e Copper Cabling System VC FA N T N XX XX XX CATEGORY SHEATH TYPE ARMOR TYPE N=Indoor T=Tight Buffered N=N/A CORES NO. FIBRE TYPE Voice System Solutions TYPE FA=Fibre Cable JACKET 01=1 M1=OM1 FN=OFN 02=2 M2=OM2 NR=OFNR 04=4 M3=OM3 LS=LSZH (60332-1) 06=6 M4=OM4 08=8 Fibre Cabling System 12=12 Ordering Information Part No. Description VCFANTNxxM1LS 62.5/125μm(OM1), Multimode, X Optical Fibre Cable, Orange, LSZH, VCFANTNxxM1FN 62.5/125μm(OM1), Multimode, X Optical Fibre Cable, Orange, OFN, VCFANTNxxM1NR 62.5/125μm(OM1), Multimode, X Optical Fibre Cable, Orange, OFNR VCFANTNxxM2LS 50/125μm(OM2), Multimode, X Optical Fibre Cable, Orange LSZH VCFANTNxxM2FN 50/125μm(OM2), Multimode, X Optical Fibre Cable, Orange, OFN VCFANTNxxM2NR 50/125μm(OM2), Multimode, X Optical Fibre Cable, Orange, OFNR VCFANTNxxM3LS 50/125μm(OM3), Multimode, X Optical Fibre Cable, Green, LSZH VCFANTNxxM3FN 50/125μm(OM3), Multimode, X Optical Fibre Cable, Green, OFN VCFANTNxxM3NR 50/125μm(OM3), Multimode, X Optical Fibre Cable, Green, OFNR VCFANTNxxM4LS 50/125μm(OM4), Multimode, X Optical Fibre Cable, Purple, LSZH VCFANTNxxM4FN 50/125μm(OM4), Multimode, X Optical Fibre Cable, Purple, OFN VCFANTNxxM4NR 50/125μm(OM4), Multimode, X Optical Fibre Cable, Purple, OFNR Note: xx denotes core number www.vivanco.asia 053 Fibre Cabling System FTTH Indoor Optical Fibre Cable Compliance • ISO/IEC 11801:2008 • ANSI/EIA-568-C.3 • ITU G.652D • ITU G.657A Optical fibre FRP strength member LSZH sheath Features & Benefits • Simple and reasonable structure with good compression, tensile, anti-aging properties • "8" groove design, easy to peel sheath, simplifies installation and maintenance • Smaller bend radius and excellent flexibility to meet all kinds of indoor wiring FTTH environment • Small diameter, light weight and strong practicability Cable Construction Cable Type Jacket Thickness (mm) ≥0.4 Jacket Color Black Jacket LSZH Flammability IEC 60332-1 Blue, orange, green, brown Covering Color Strength Member FRP Short Term/ Long Term Pull Tension (N) 80/40 Short Term/Long Term Crush Tension N/100(mm) Dynamic/Static Min. Bend Radius(mm) Operating Temperature 054 G.657A G.652D 1000/500 30/15 50/30 -20℃~60℃ www.vivanco.asia CAT 6A Copper Cabling System Fibre Cabling System FTTH Indoor Optical Fibre Cable CAT 6 Copper Cabling System Optical Performance Wavelength (nm) 1310 1550 Attenuation (Max.) (dB/km) 0.45 0.22 Cutoff Wavelength (λcc) ≤1250 Temperature and Attenuation (dB/km) CAT 5e Copper Cabling System ≤0.2 1300nm-1324nm; ≤0.092 Zero Dispersion Slope (ps/nm² ×km) Microbending Loss (db) Bending diameter (15mm 10 circles)≤0.4 Voice System Solutions VC FH N X X XX XX CATEGORY STRENGTH MEMBER CORES NO. FIBRE TYPE N=Indoor F=FRP 1=1 S2=OS2 FN=OFN S=Steel 2=2 7A=G.657A NR=OFNR Fibre Cabling System TYPE FH=Fibre Cable JACKET LS =LSZH (60332-1) 4=4 Ordering Information Part No. Description VCFHNxx7ALS Indoor Fibre Cable, X-core G.657A, FRP, LSZH VCFHNxx7AFN Indoor Fibre Cable, X-core G.657A, FRP, OFN VCFHNxx7ANR Indoor Fibre Cable, X-core G.657A, FRP, OFNR VCFHNxx7ALS Indoor Fibre Cable, X-core G.657A, Steel, LSZH VCFHNxx7AFN Indoor Fibre Cable, X-core G.657A, Steel, OFN VCFHNxx7ANR Indoor Fibre Cable, X-core G.657A, Steel, OFNR Note:xx denotes core number www.vivanco.asia 055 Fibre Cabling System Unitube Light/Strong Armoured Optical Fibre Cable, Single Mode Light Armor Compliance • ISO/IEC 11801:2008 PE outer sheath Steel tape • ANSI/EIA-568-C.3 • ITU G.652D Loose tube Metal strength member Optical fibre Filling gel Heavy Armor PE outer sheath Corrugated steel tape armored PE inner sheath Steel tape Metal strength member Features & Benefits • Two parallel steel strips ensures resistance to lateral pressure • PE jacket offers excellent waterproof and ultraviolet resistance characteristics • Can be installed outdoors in pipe or direct burial Loose tube Optical fibre Filling gel Cable Construction Cable Type Armor Type G.652.D Light armor Jacket Thickness (mm) 1.8(±0.1) Strength Member Armor Material Inner Tube Material Steel Steel strip Steel strip & wrinkles steel – PE Loose Tube PBT/PP PE Jacket Black Jacket Color Covering Color Short Term/Long Term Pulling Tension(N) Short Term/Long Term Crush Tension N/100 (mm) Dynamic/Static Min. Bend Radius(mm) Operating Temperature 056 Heavy armor Blue, orange, green, brown, gray, white, red, black, yellow, purple, pink, turquoise 1500/600 3000/1000 1000/300 3000/1000 20/10 25/12.5 -40℃~60℃ www.vivanco.asia CAT 6A Copper Cabling System Fibre Cabling System Unitube Light/Strong Armoured Optical Fibre Cable, Single Mode CAT 6 Copper Cabling System Optical Performance Wavelength (nm) Attenuation (Max.) (dB/km) 1310 1550 ≤0.38 ≤0.23 Cutoff Wavelength (λcc) ≤1260 Temperature and Attenuation (dB/km) CAT 5e Copper Cabling System ≤0.1 1300nm-1324nm; ≤0.092 Zero Dispersion Slope (ps/nm² ×km) Microbending Loss (db) ≤0.1 Voice System Solutions TYPE FA=Fibre Cable CATEGORY SHEATH TYPE ARMOR TYPE CORES NO. FIBRE TYPE JACKET U=Outdoor U=Loose Tube S=Steel Tape 01=1 S2=OS2 PE=Outdoor (No Cert) H= Steel Tape & Corrugated Steel Tape 04=4 02=2 06=6 08=8 12=12 Ordering Information Part No. Description VCFAUUSxxS2PE Light Armor X Fibre Cable, Single Mode, 1Tube, Black VCFAUUHxxS2PE Heavy Armor X Fibre Cable, Single Mode, 1Tube, Black Note:xx denotes core number www.vivanco.asia 057 Fibre Cabling System VC FA U U X XX S2 PE Fibre Cabling System Unitube Light/Strong Armoured Optical Fibre Cable, Multi Mode Light Armor Compliance PE outer sheath Steel tape • ISO/IEC 11801:2008 • ANSI/EIA-568-C.3 Loose tube Metal strength member Optical fibre Filling gel Heavy Armor Features & Benefits PE outer sheath Corrugated steel tape armored PE inner sheath Steel tape Metal strength member • Multimode core have the precise refractive index distribution curve and eliminate the phenomenon of the central recess of the multimode optical fibre • Two parallel steel strips ensures resistance to lateral pressure • PE jacket offers excellent waterproof and ultraviolet resistance characteristics • Can be installed outdoors in pipe or direct burial Loose tube Optical fibre Filling gel Cable Construction Cable Type Armor Type OM1, OM2, OM3, OM4 Light armor Jacket Thickness(mm) 1.8(±0.1) Strength Member Armor Material Inner Tube Material Steel Steel strip Steel strip & wrinkles steel – PE PBT/PP Loose Tube PE Jacket Black Jacket Color Covering Color Blue, orange, green, brown, gray, white, red, black, yellow, purple, pink, turquoise Short Term/Long Term Pull Tension (N) 1500/600 3000/1000 Short Term/Long Term Crush Tension N/100 (mm) 1000/300 3000/1000 20/10 25/12.5 Dynamic / Static Min. Bend Radius (mm) Operating Temperature 058 Heavy armor -40℃~60℃ www.vivanco.asia CAT 6A Copper Cabling System Fibre Cabling System Unitube Light/Strong Armoured Optical Fibre Cable, Multi Mode CAT 6 Copper Cabling System Optical Performance Wavelength (nm) Attenuation (Max.) (dB/km) 850 1300 ≤33.5 ≤1.5 Temperature and Attenuation (dB/km) ≤0.2 CAT 5e Copper Cabling System Voice System Solutions VC FA N T N XX XX PE TYPE CATEGORY SHEATH TYPE ARMOR TYPE CORES NO. FIBRE TYPE N=Indoor T=Tight Buffered N=N/A 01=1 M1=OM1 FN=OFN 02=2 M2=OM2 NR=OFNR 04=4 M3=OM3 LS=LSZH (60332-1) 06=6 M4=OM4 JACKET Fibre Cabling System FA=Fibre Cable 08=8 12=12 Ordering Information Part No. Description VCFANTNxxM1PE Light Armor Fibre Cable, Multimode, 1Tube, Black, 62.5/125 0M1 VCFANTNxxM2PE Light Armor Fibre Cable, Multimode, 1Tube, Black, 50/125 OM2 VCFANTNxxM3PE Light Armor Fibre Cable, Multimode, 1Tube, Black 50/125 OM3 VCFANTNxxM4PE Light Armor Fibre Cable, Multimode, 1Tube, Black, 50/125 OM4 VCFANTNxxM1PE Heavy Armor Fibre Cable, Multimode, 1Tube, Black, 62.5/125 0M1 VCFANTNxxM2PE Heavy Armor Fibre Cable, Multimode, 1Tube, Black, 50/125 OM2 VCFANTNxxM3PE Heavy Armor Fibre Cable, Multimode, 1Tube, Black, 50/125 OM3 VCFANTNxxM4PE Heavy Armor Fibre Cable, Multimode, 1Tube, Black, 50/125 OM4 Note:xx denotes core number www.vivanco.asia 059 Fibre Cabling System Armoured Steel Tape Optical Fibre Cable, Single Mode Compliance • ISO/IEC 11801:2008 • ANSI/EIA-568-C.3 • ITU G.652D CSM-steel wire Loose tube or filler rod Optical or fillig gel Steel tape PE outer sheath Features & Benefits • G652.D singlemode fiber has advantage of low attenuation, low dispersion and low polarization • Steel-polyethylene sheath cable has excellent mechanical tensile stress and temperature characteristics • Loose tube jelly filled with water repelling properties ensures protection of fibre against water ingression • Can be installed in pipe or direct burial Cable Construction Cable Type G.652D Tube Thickness(mm) 1.8(±0.1) <72core Steel ≥72core Steel stripe & PE Strength Member Armored Material Steel stripe/PE Loose Tube PBT Filling Rod PP/PE Filling Material Gel Jacket Material PE Jacket Color Covering Color Operating Temperature Black Blue, orange, green, brown, gray, white, red, black, yellow, purple, pink, turquoise -40℃~60℃ Short Term/Long Term Pulling Tension (N) 1500/600 Short Term/Long Term Crush Tension (N) 1000/300 Dynamic/Static Min. Bend Radius (D) 060 20/10 www.vivanco.asia CAT 6A Copper Cabling System Fibre Cabling System Armoured Steel Tape Optical Fibre Cable, Single Mode CAT 6 Copper Cabling System Optical Performance Wavelength (nm) Attenuation (Max.) (dB/km) 1310 1550 ≤0.36 ≤0.22 Cutoff Wavelength (λcc) ≤1260 Temperature and Attenuation (dB/km) CAT 5e Copper Cabling System ≤0.1 1300nm-1324nm; ≤0.092 Zero Dispersion Slope (ps/nm² ×km) Micro Bending Loss (db) ≤0.1 Voice System Solutions Fibre Cabling System VC FA U S S XX S2 PE TYPE CATEGORY FA=Fibre Cable U=Outdoor SHEATH TYPE S=Stranded Loose Tube ARMOR TYPE CORES NO. FIBRE TYPE JACKET S=Steel Tape 01=1 S2=OS2 PE=Outdoor (No Cert) 02=2 04=4 06=6 08=8 12=12 …… Ordering Information Part No. VCFAUSSxxS2PE Description Steel Tape X Fibre Cable, Single Mode, Black Note:xx denotes core number www.vivanco.asia 061 Fibre Cabling System Armoured Steel Tape Optical Fibre Cable, Multi Mode Compliance • ISO/IEC 11801:2008 • ANSI/EIA-568-C.3 CSM-steel wire Loose tube or filler rod Optical or fillig gel Steel tape Features & Benefits PE outer sheath • Multimode fibre with a precise refractive index distribution curve, eliminate the center of multimode fibre depression phenomenon • Steel-polyethylene sheath cable has excellent mechanical tensile stress • Loose tube jelly filled with water repelling properties ensures protection of fibre against water ingression • Can be installed in pipe or direct burial Cable Construction Cable Type OM1, OM2, OM3, OM4 1.8(±0.1) Tube Thickness(mm) <72core Steel ≥72core Steel stripe & PE Strength Member Armored Material Steel stripe/PE Loose Tube PBT Filling Rod PP/PE Filling Material Gel Jacket Material PE Jacket Color Covering Color Operating Temperature Black Blue, orange, green, brown, gray, white, red, black, yellow, purple, pink, turquoise -40℃~60℃ Short Term/Long Term Pull Tension (N) 1500/600 Short Term/Long Term Crush Tension (N) 1000/300 Dynamic/Static Min. Bend Radius (D) 062 20/10 www.vivanco.asia CAT 6A Copper Cabling System Fibre Cabling System Armoured Steel Tape Optical Fibre Cable, Multi Mode CAT 6 Copper Cabling System Optical Performance Wavelength (nm) Attenuation (Max.) (dB/km) 850 1300 ≤3.5 ≤1.5 Temperature and Attenuation (dB/km) ≤0.2 CAT 5e Copper Cabling System Voice System Solutions VC FA U S S XX XX PE CATEGORY U=Outdoor SHEATH TYPE S=Stranded Loose Tube ARMOR TYPE CORES NO. FIBRE TYPE JACKET S=Steel Tape 01=1 M1=OM1 PE=Outdoor (No cert) 02=2 M2=OM2 04=4 M3=OM3 06=6 M4=OM4 08=8 12=12 …… Ordering Information Part No. Description VCFAUSSxxM1PE Steel Tape X Fibre Cable, Multimode, Black, 62.5/125 OM1 VCFAUSSxxM2PE Steel Tape X Fibre Cable, Multimode, Black, 50/125 OM2 VCFAUSSxxM3PE Steel Tape X Fibre Cable, Multimode, Black, 50/125 OM3 VCFAUSSxxM4PE Steel Tape X Fibre Cable, Multimode, Black, 50/125 OM4 Note:xx denotes core number www.vivanco.asia 063 Fibre Cabling System TYPE FA=Fibre Cable Fibre Cabling System Light Armoured Aluminum Tape Optical Fibre Cable, Single Mode Compliance • ISO/IEC 11801:2008 • ANSI/EIA-568-C.3 • ITU G.652D CSM-steel wire Loose tube or filler rod Optical or fillig gel Aluminium tape PE outer sheath Features & Benefits • G652.D singlemode has advantage of Low attenuation, low dispersion and low polarization • Aluminum & polyethylene sheath cable has excellent mechanical tensile stress, and good ultraviolet radiation protection • Loose tube jelly filled with water repelling properties ensures protection of fibre against water ingression • Can be installed in pipe or direct burial Cable Construction Cable Type G.652D Tube Thickness (mm) 1.8(±0.1) <72core Steel ≥72core Steel stripe & PE Strength Member Armored Material Steel stripe/PE Loose Tube PBT Filling Rod PP/PE Filling Material Gel Jacket Material PE Jacket Color Covering Color Operating Temperature Black Blue, orange, green, brown, gray, white, red, black, yellow, purple, pink, turquoise -40℃~60℃ Short Term/Long Term Pull Tension (N) 1500/600 Short Term/Long Term Crush Tension (N) 1000/300 Dynamic/Static Min. Bend Radius (D) 064 20/10 www.vivanco.asia CAT 6A Copper Cabling System Fibre Cabling System Light Armoured Aluminum Tape Optical Fibre Cable, Single Mode CAT 6 Copper Cabling System Optical Performance Wavelength (nm) 1310 1550 Attenuation (Max.) (dB/km) ≤0.36 ≤0.22 Cutoff Wavelength (λcc) ≤1260 Temperature and Attenuation (dB/km) CAT 5e Copper Cabling System ≤0.1 1300nm-1324nm; ≤0.092 Zero Dispersion Slope (ps/nm² ×km) Microbending Loss (db) ≤0.1 Voice System Solutions TYPE CATEGORY FA=Fibre Cable U=Outdoor SHEATH TYPE S=Stranded Loose Tube ARMOR TYPE CORES NO. FIBRE TYPE JACKET A=Aluminum Tape 01=1 S2=OS2 PE=Outdoor (No Cert) 02=2 04=4 06=6 08=8 12=12 …… Ordering Information Part No. VCFAUSAxxS2PE Description Aluminum Tape X Fibre Cable, Single Mode, Black Note:xx denotes core number www.vivanco.asia 065 Fibre Cabling System VC FA U S A XX S2 PE Fibre Cabling System Armoured Aluminum Tape Optical Fibre Cable, Multi Mode Compliance • ISO/IEC 11801:2008 • ANSI/EIA-568-C.3 Features & Benefits CSM-steel wire • Multimode fibre with a precise refractive index distribution curve, eliminate the center of the multimode fibre depression phenomenon Loose tube or filler rod • Aluminum & polyethylene sheath cable has excellent mechanical tensile stress and temperature characteristics, but also has good ultraviolet radiation protection Aluminium tape Optical or fillig gel PE outer sheath • Tube filled with a special jelly, for the protection of fibre optic, ensuring a protection moisture capacity • Can be installed in pipe or direct burial Cable Construction Cable Type OM1, OM2, OM3, OM4 1.8(±0.1) Tube Thickness (mm) <72core Steel ≥72core Steel stripe & PE Strength Member Armored Material Steel stripe/PE Loose Tube PBT Filling Rod PP/PE Filling Material Gel Jacket Material PE Jacket Color Covering Color Operating Temperature Black Blue, orange, green, brown, gray, white, red, black, yellow, purple, pink, turquoise -40℃~60℃ Short Term/Long Term Pull Tension (N) 1500/600 Short Term/Long Term Crush Tension (N) 1000/300 Dynamic/Static Min. Bend Radius (D) 066 20/10 www.vivanco.asia CAT 6A Copper Cabling System Fibre Cabling System Armoured Aluminum Tape Optical Fibre Cable, Multi Mode CAT 6 Copper Cabling System Optical Performance Wavelength (nm) Attenuation (Max.) (dB/km) 850 1300 ≤3.5 ≤1.5 Temperature and Attenuation (dB/km) ≤0.2 CAT 5e Copper Cabling System Voice System Solutions VC FA U S A XX XX PE CATEGORY U=Outdoor SHEATH TYPE S=Stranded Loose Tube ARMOR TYPE CORES NO. FIBRE TYPE JACKET A=Aluminum Tape 01=1 M1=OM1 PE= Outdoor (No Cert) 02=2 M2=OM2 04=4 M3=OM3 06=6 M4=OM4 08=8 12=12 …… Ordering Information Part No. Description VCFAUSAxxM1PE Aluminum Tape X Fibre Cable, Multimode, Black, 62.5/125 OM1 VCFAUSAxxM2PE Aluminum Tape X Fibre Cable, Multimode, Black, 50/125 OM2 VCFAUSAxxM3PE Aluminum Tape X Fibre Cable, Multimode, Black, 50/125 OM3 VCFAUSAxxM4PE Aluminum Tape X Fibre Cable, Multimode, Black, 50/125 OM4 Note:xx denotes core number www.vivanco.asia 067 Fibre Cabling System TYPE FA=Fibre Cable Fibre Cabling System Non-metallic Optical Fibre Cable, Single Mode Compliance • ISO/IEC 11801:2008 • ANSI/EIA-568-C.3 • ITU G.652D FRP Strenght menber Features & Benefits Loose tube Tube filling compound • Adopts G.652.D single mode fibre with the advantages of low attenuation, low dispersion and low polarization • Polyethylene sheath has good ultraviolet radiation protection • Non-metallic strength member with tensile role, can improve the performance of the anti-power • Tube filled with a special jelly, for the protection of fibre optic, ensuring a water proof moisture apacity • Can be installed in pipe or direct burial Cable filling compound Fibre PE sheath Cable Construction Cable Type G.652D Tube Thickness(mm) 1.8(±0.1) <72 core FRP ≥72 core FRP & PE Strength Member Loose Tube PBT Filling Rod PP/PE Filling Material Gel Jacket Material PE Jacket Color Covering Color Operating Temperature Black Blue, orange, green, brown, gray, white, red, black, yellow, purple, pink, turquoise -40℃~60℃ Short Term/Long Term Pull Tension (N) 1500/600 Short Term/Long Term Crush Tension (N) 1000/300 Dynamic/Static Min. Bend Radius (D) 068 20/10 www.vivanco.asia CAT 6A Copper Cabling System Fibre Cabling System Non-metallic Optical Fibre Cable, Single Mode CAT 6 Copper Cabling System Optical Performance Wavelength (nm) 1310 1550 Attenuation (Max.) (dB/km) ≤0.36 ≤0.22 Cutoff Wavelength (λcc) ≤1260 Temperature and Attenuation (dB/km) Zero Dispersion Slope (ps/nm² ×km) CAT 5e Copper Cabling System ≤0.1 1300nm-1324nm; ≤0.092 Microbending Loss (db) ≤0.1 Voice System Solutions TYPE CATEGORY FA=Fibre Cable U=Outdoor SHEATH TYPE S=Stranded Loose Tube ARMOR TYPE N=N/A CORES NO. FIBRE TYPE JACKET 01=1 S2=OS2 PE=Outdoor (No Cert) 02=2 04=4 06=6 08=8 12=12 …… Ordering Information Part No. Description VCFAUSNxxS2PE Stranded Loose Tube X Fibre Cable, Single Mode, Black Note:xx denotes core number www.vivanco.asia 069 Fibre Cabling System VC FA U S N XX S2 PE Fibre Cabling System Non-metallic Optical Fibre Cable, Multi Mode Compliance • ISO/IEC 11801:2008 • ANSI/EIA-568-C.3 FRP strenght menber Loose tube Features & Benefits Tube filling compound Cable filling compound • Multimode fibre with a precise refractive index distribution curve, eliminate the center of the multimode fibre depression phenomenon Fibre PE sheath • Polyethylene sheath has good ultraviolet radiation protection • Non-metallic strength member with tensile role, can improve the performance of the anti-power • Tube filled with a special jelly, for the protection of fibre optic, ensuring a water proof moisture capacity • Can be installed in pipe or direct burial Cable Construction OM1, OM2, OM3, OM4 Cable Type 1.8(±0.1) Tube Thickness (mm) <72 core FRP ≥72 core FRP & PE Strength Member Loose Tube PBT Filling Rod PP/PE Filling Material Gel Jacket Material PE Jacket Color Covering Color Operating Temperature Black Blue, orange, green, brown, gray, white, red, black, yellow, purple, pink, turquoise -40℃~60℃ Short Term/Long Term Pull Tension (N) 1500/600 Short Term/Long Term Crush Tension (N) 1000/300 Dynamic/Static Min. Bend Radius (D) 070 20/10 www.vivanco.asia CAT 6A Copper Cabling System Fibre Cabling System Non-metallic Optical Fibre Cable, Multi Mode CAT 6 Copper Cabling System Optical Performance Wavelength (nm) 850 1300 Attenuation (Max.) (dB/km) ≤3.5 ≤1.5 Temperature and Attenuation (dB/km) ≤0.2 CAT 5e Copper Cabling System Voice System Solutions VC FA U S N XX XX PE CATEGORY U=Outdoor SHEATH TYPE S=Stranded Loose Tube ARMOR TYPE CORES NO. FIBRE TYPE JACKET N=N/A 01=1 M1=OM1 PE=Outdoor (No Cert) 02=2 M2=OM2 04=4 M3=OM3 06=6 M4=OM4 08=8 12=12 …… Ordering Information Part No. Description VCFAUSNxxM1PE Stranded Loose Tube X Fibre Cable, Multimode, Black, 62.5/125 OM1 VCFAUSNxxM2PE Stranded Loose Tube X Fibre Cable, Multimode, Black, 50/125 OM2 VCFAUSNxxM3PE Stranded Loose Tube X Fibre Cable, Multimode, Black, 50/125 OM3 VCFAUSNxxM4PE Stranded Loose Tube X Fibre Cable, Multimode, Black, 50/125 OM4 Note:xx denotes core number www.vivanco.asia 071 Fibre Cabling System TYPE FA=Fibre Cable Fibre Cabling System Reinforced Armoured And Duo-sheath Optical Fibre Cable, Single Mode Compliance • ISO/IEC 11801:2008 • ANSI/EIA-568-C.3 • ITU G.652D CSM-steel wire Aluminium tape Loose tube Optical or fillig gel Features & Benefits PE inner sheath • Adopt G.652D singlemode fibre with the advantages of low attenuation, low dispersion and low polarization • Aluminum & polyethylene sheath cable has excellent mechanical tensile stress and temperature characteristics, but also has good ultraviolet radiation protection • Tube filled with a special jelly, for the protection of fibre optic, ensuring a water proof moisture capacity • Can be installed in pipe or direct burial Corrugated steel tape armored PE outer sheath Cable Construction Cable Type G.652.D Tube Thickness (mm) 1.8(±0.1) Strength Member Armored Material <72core Steel ≥72core Steel stripe & PE Aluminum & wrinkles steel Inner Tube Material PE Loose Tube PTB Filling Rod PP/PE Filling Material Gel Jacket Material PE Jacket Color Covering Color Operating Temperature Black Blue, orange, green, brown, gray, white, red, black, yellow, purple, pink, turquoise -40℃~60℃ Short Term/Long Term Pull Tension (N) 3000/1000 Short Term/Long Term Crush Tension (N) 3000/1000 Dynamic/Static Min. Bend Radius (D) 072 25/12.5 www.vivanco.asia CAT 6A Copper Cabling System Fibre Cabling System Reinforced Armoured And Duo-sheath Optical Fibre Cable, Single Mode CAT 6 Copper Cabling System Optical Performance Wavelength (nm) 1310 1550 Attenuation (Max.) (dB/km) ≤0.36 ≤0.22 Cutoff Wavelength (λcc) ≤1260 Temperature and Attenuation (dB/km) Zero Dispersion Slope (ps/nm² ×km) CAT 5e Copper Cabling System ≤0.1 1300nm-1324nm; ≤0.092 Micro Bending Loss(db) ≤0.1 Voice System Solutions TYPE CATEGORY FA=Fibre Cable U=Outdoor SHEATH TYPE S=Stranded Loose Tube ARMOR TYPE L= Aluminum Tape & Corrugated Steel Tape CORES NO. FIBRE TYPE JACKET 01=1 S2=OS2 PE=Outdoor (No Cert) 02=2 04=4 06=6 08=8 12=12 …… Ordering Information Part No. VPFAUSLxxS2PE Description Reinforced Armor and Duo-Sheath X Fibre Cable, Single Mode Note:xx denotes core number www.vivanco.asia 073 Fibre Cabling System VP FA U S L XX S2 PE Fibre Cabling System Reinforced Armoured And Duo-sheath Optical Fibre Cable, Multi Mode Compliance • ISO/IEC 11801:2008 • ANSI/EIA-568-C.3 CSM-steel wire Aluminium tape Loose tube Optical or fillig gel Features & Benefits PE inner sheath • Multimode fibre with a precise refractive index distribution curve, eliminate the center of the multimode fibre depression phenomenon • Aluminum & polyethylene sheath cable has excellent mechanical tensile stress and temperature characteristics, but also has good ultraviolet radiation protection • Tube filled with a special jelly, for the protection of fibre optic, ensuring a water proof moisture capacity • Can be installed in pipe or direct burial Corrugated steel tape armored PE outer sheath Cable Construction Cable Type OM1, OM2, OM3, OM4 1.8(±0.1) Tube Thickness (mm) Strength Member Armored Material Inner Tube Material <72core Steel ≥72core Steel stripe & PE Aluminum & wrinkles steel PE Loose Tube PTB Filling Rod PP/PE Filling Material Gel Jacket Material PE Jacket Color Covering Color Operating Temperature Black Blue, orange, green, brown, gray, white, red, black, yellow, purple, pink, turquoise -40℃~60℃ Short Term/Long Term Pull Tension (N) 3000/1000 Short Term/Long Term Crush Tension (N) 3000/1000 Dynamic/Static Min. Bend Radius (D) 074 25/12.5 www.vivanco.asia CAT 6A Copper Cabling System Fibre Cabling System Reinforced Armoured And Duo-sheath Optical Fibre Cable, Multi Mode CAT 6 Copper Cabling System Optical Performance Wavelength (nm) Attenuation (Max.) (dB/km) 850 1300 ≤3.5 ≤1.5 Temperature and Attenuation (dB/km) ≤0.2 CAT 5e Copper Cabling System Voice System Solutions VP FA U S L XX XX PE CATEGORY U=Outdoor SHEATH TYPE S=Stranded Loose Tube ARMOR TYPE L=Aluminum Tape & Corrugated Steel Tape CORES NO. FIBRE TYPE JACKET 01=1 M1=OM1 PE=Outdoor (No Cert) 02=2 M2=OM2 04=4 M3=OM3 06=6 M4=OM4 08=8 12=12 …… Ordering Information Part No. Description VPFAUSLxxM1PE Reinforced Armor and Duo-sheath X Fibre Cable, Multimode, Black, 62.5/125 OM1 VPFAUSLxxM2PE Reinforced Armor and Duo-sheath X Fibre Cable, Multimode, Black, 50/125 OM2 VPFAUSLxxM3PE Reinforced Armor and Duo-sheath X Fibre Cable, Multimode, Black, 50/125 OM3 VPFAUSLxxM4PE Reinforced Armor and Duo-sheath X Fibre Cable, Multimode, Black, 50/125 OM4 Note:xx denotes core number www.vivanco.asia 075 Fibre Cabling System TYPE FA=Fibre Cable Fibre Cabling System Optical Fibre Adaptor Compliance • ISO/IEC11801:2008 • ANSI/TIA/EIA 568-C.3 • IEC 61754 A B C D E F G H I J K L M H O Features & Benefits •Compatible, repeatable, interchangeable • High-precision, high-quality material • Good stability Construction Adapter Material Outer Cover Material Work/storage Temperature Ceramics Zinc alloy (FC, ST), PC (LC, SC) -40℃~80℃ Insertion Force ≤19.6N Pulling Force ≤19.6N Axial Tensile Strength ≥40N Optical Performance Insertion Loss(db) ≤0.2 (SM); ≤0.1(MM) Return Loss(db) ≥35 Insertion Loss Variation(db) ≤0.1 Return Loss Variation(db) ≤5 076 P Q www.vivanco.asia CAT 6A Copper Cabling System Fibre Cabling System Optical Fibre Adaptor TYPE CONNECTOR TYPE MODES N CONNECTOR STYLE STYLE LC=LC-LC S=Single mode S=Simplex P=PC SC=SC-SC M=Multi mode D=Duplex U=UPC Q=Quadplex A=APC ST=ST-ST ADAPTOR STYLE CAT 5e Copper Cabling System FJ=Fibre Adaptor X CAT 6 Copper Cabling System VP FJ XX X X N=Normal FC=FC-FC Ordering Information A FC/PC SM Simplex Adapter VCFJFCSSAN B FC/APC SM Simplex Adapter VCFJSTSSPN C ST/PC SM Simplex Adapter VCFJSCSSPN D SC/PC SM Simplex Adapter VCFJSCSDPN E SC/PC SM Duplex Adapter VCFJSCMSPN F SC/PC MM Simplex Adapter VCFJSCMDPN G SC/PC MM Duplex Adapter VCFJSCSSAN H SC/APC SM Simplex Adapter VCFJSCSDAN I SC/APC SM Duplex Adapter VCFJLCSDPN J LC/PC SM Duplex Adapter VCFJLCSQPN K LC/PC SM 4 Cores Adapter VCFJLCMDPN L LC/PC MM Duplex Adapter VCFJLCMQPN M LC/PC MM 4 Cores Adapter VCFJLCSDAN N LC/APC SM Duplex Adapter VCFJLCSQAN O LC/APC SM 4 Cores Adapter VCFJSCSSPK SC/SC Simplex SM Adaptor (for copper patch panel) VCFJSCMSPK SC/SC Simplex MM Adaptor (for copper patch panel) VCFJLCSDPK LC/LC Duplex SM Adaptor (for copper patch panel) VCFJLCMDPK LC/LC Duplex MM Adaptor (for copper patch panel) www.vivanco.asia Fibre Accessories VCFJFCSSPN Fibre Cabling System Description Voice System Solutions Part No. 077 Fibre Cabling System Optical Fibre Fast Termination Optical Fibre Connector Fast Termination Connector Compliance • ISO/IEC11801:2008 • ANSI/TIA/EIA 568-C.3 • IEC 61754 Features & Benefits •Field termination no clean room required • No splicing kit or any other equipment required • High reliability, minimal insertion loss Construction Fibre Tightening Force Mechanical Durability Operating Temperature 5N ≥500 times -25℃~70℃ Optical Performance Insertion Loss ≤0.3dB Return Loss ≥40dB Ordering Information Part No. Description VCFNFTSCSP SC, Fast Termination Connector Optical Fibre Field- instant Connector Compliance • ISO/IEC11801:2008 • ANSI/TIA/EIA 568-C.3 • IEC 61754 Features & Benefits • Field termination no clean room required • No splicing kit or any other equipment required • High reliability, minimal insertion loss Construction Fibre Tightening Force Mechanical Durability Operating Temperature 5N ≥500 times -25℃~70℃ Optical Performance Insertion Loss ≤0.3dB Return Loss ≥40dB Ordering Information 078 Part No. Description VCFNFJ1 Optical Fibre Field- instant Connector (for φ 0.25 mm & φ0.90 mm) VCFNFJ2 Optical Fibre Field- instant Connector (for φ 2 mm) www.vivanco.asia CAT 6A Copper Cabling System Fibre Cabling System Optical Fibre Patch Panel, Distribution Frame CAT 6 Copper Cabling System 12, 24, 72 port Compliance • ISO/IEC11801:2008 • ANSI/TIA/EIA 568-C.3 Features & Benefits CAT 5e Copper Cabling System • 19 "standard installation, suitable for a variety of rack, cabinet installation • Pull-out design, set field welding, welding wiring module integration • Each disk can be tabbed to install 12 pcs of FC, LC duplex, SC, and ST adapters 48, 96 port Construction SPCC Distribution Board Material PVC Item Dimension (mm) (length*width*height) 1U 430*280*445 2U 430*280*90 3U 485*345*132 4U 430*280*180 5U 485*345*225 Voice System Solutions Material ≥30 Construction Max Fibre Count 192 Insertion Loss (db) ≤0.3 Return Loss (db) ≥35 SC, FC, ST, duplex LC Adapter Fibre Cabling System Maximum Bending Space (mm) Name Coding VC FP D X N XX N TYPE STYLE MODES CONNECTOR TYPE CONNECTOR STYLE PORT HEIGHT S= Simplex N=N/A ST=ST 24=24 2=2U 48=48 3=3U 72=72 4=4U 96=96 5=5U D=Duplex T=Simplex&Duplex N=N/A TC=SC&FC& DuplexLC Ordering Information Part No. Description VCFPDSNSTN242 24 Port ODF(for 24 core ST, adaptor unloaded, 2U) VCFPDTNTCN242 24 Port ODF (for 24 core SC/FC, 48 core duplex LC, adaptor unloaded, 2U) VCFPDSNSTN483 48 Port ODF(for 48 core ST, adaptor unloaded, 3U) VCFPDTNTCN483 48 Port ODF (for 48 core SC/FC, 96 core duplex LC, adaptor unloaded, 3U) VCFPDSNSTN724 72 port ODF (for 72 core ST, adaptor unloaded, 4U) VCFPDTNTCN724 72 Port ODF (for 72 core SC/FC, 144 core duplex LC, adaptor unloaded, 4U) VCFPDSNSTN965 96 port ODF (for 96 core ST, adaptor unloaded, 5U) VCFPDTNTCN965 96 Port ODF (for 96 core SC/FC, 192 core duplex LC, adaptor unloaded, 5U) www.vivanco.asia 079 Fibre Accessories TYPE FP =Fibre Panel D= ODF 24 N Fibre Cabling System 19" Optical Fibre Patch Panel, Rack Mount Compliance • ISO/IEC11801:2008 • ANSI/TIA/EIA 568-C.3 Features & Benefits • Sturdy metal construction to house adapters • 19” standard design suitable for all cabinets and racks • Compact structure, small size, light weight • Well designed splice tray for fusion splicing • Sliding mechanism allows for faster and easier access for maintenance and troubleshooting Construction Material SPCC 450mm*375mm*150mm Size Surface Spray Maximum bending space(mm) ≥30 Max Fibre Count Optical Performance 48 Insertion Loss ≤0.3 Return Loss ≥35 VC FP R X N XX N TYPE TYPE FP =Fibre Panel R= Rack mount 24 N STYLE MODES CONNECTOR TYPE CONNECTOR STYLE PORT HEIGHT S= Simplex N=N/A ST=ST 24=24 N=N/A D=Duplex SC=SC T=Simplex&Duplex FC=FC N=N/A LC=Duplex LC Ordering Information Part No. Description VCFPRSNSTN121 12 Port Optic Fibre Patch Panel (for 12 core ST, adaptor unloaded,without rail, 1U) VCFPRTNSLN121 12 Port Optic Fibre Patch Panel (for 12 core SC, 24 core duplex LC, adaptor unloaded, without rail,1U) VCFPRSNFCN121 12 Port Optic Fibre Patch Panel (for 12 core FC, adaptor unloaded, without rail,1U) VCFPRSNSTN241 24 Port Optic Fibre Patch Panel (for 24 core ST, adaptor unloaded, without rail,1U) VCFPRTNSLN241 24 Port Optic Fibre Patch Panel (for 24 core SC, 48 core duplex LC,adaptor unloaded,without rail,1U) VCFPRSNFCN241 24 Port Optic Fibre Patch Panel (for 24 core FC, adaptor unloaded, without rail,1U) 080 www.vivanco.asia CAT 6A Copper Cabling System Fibre Cabling System 19" Optical Fibre Patch Panel, Sliding Type CAT 6 Copper Cabling System Compliance • ISO/IEC11801:2008 • ANSI/TIA/EIA 568-C.3 CAT 5e Copper Cabling System Features & Benefits • Metal structure provides protection for fibre terminating and adapter installation • 19″ standard design, for various of rack and cabinet installat • Compact structure, small size, light weight • Fast fibre installation, sufficient fusion and bending space Material SPCC Surface Spray 8 Port Plate Aluminum 24 core Field-instant Drum 485mm*44mm*340mm Maximum Bending Space (mm) Insertion Loss ≤0.3 Port number Return Loss ≥35 Adapter TYPE TYPE S=Slide Rack Mount ≥30 96 SC, FC, ST, LC (duplex), SC (duplex), LC ( 4 core) Fibre Accessories VC FP S X N XX N FP=Fibre Panel ABS Fibre Cabling System Size Optical Performance Voice System Solutions Construction 24 N STYLE MODES CONNECTOR TYPE CONNECTOR STYLE PORT HEIGHT S=Simplex N=N/A ST=ST 24=24 N=1U D=Duplex TC=SC&FC&LC T=Simplex&Duplex TC=SC&FC&LC N=N/A CC=Duplex SC & 4 Core LC Ordering Information Part No. Description VCFPSSNSTN241 24 Port Optic Fibre Patch Panel (for 24 core ST, adaptor unloaded, rail,1U) VCFPSTNSLN241 24 Port Optic Fibre Patch Panel (for 24 core SC, 48 core duplex LC, adaptor unloaded, rail,1U) VCFPSSNFCN241 24 Port Optic Fibre Patch Panel (for 24 core FC, adaptor unloaded, rail,1U) www.vivanco.asia 081 Fibre Cabling System MPO-MPO Fast Termination Extension Patch Cord Compliance • ISO/IEC11801:2008 • ANSI/TIA/EIA 568-C.3 • IEC/EN 61754 Features & Benefits • Both ends are A/B/C optional connectors • Termination of distribution box with MPO-LC connector to match • Contain 12 core optical fibre • Small diameter of fibre optic cable, reduces insertion loss overcoming the bending sensitivity problem • Small diameter to save the room Product Performance Multi mode: 50/125 (OM3) Fibre Type Singlemode: G652.D Insertion Loss (dB) ≤0.3 Return Loss (dB) ≥40 MPO Connector Moble B Fibre Core 12 core Operating Temperature -20℃~60℃ Ordering Information Part No. Description VCS908-A2D-X MPO-MPO Fast Termination Extension Patch Cord (Single Mode, 12 core, X m) VCS908-AM3-X MPO-MPO Fast Termination Extension Patch Cord (Multi Mode, OM3, 12 core, X m) Note:X denotes length 082 www.vivanco.asia CAT 6A Copper Cabling System Fibre Cabling System MPO-LC Fast Termination Optical Fibre Patch Cord CAT 6 Copper Cabling System Compliance • ISO/IEC11801:2008 • ANSI/TIA/EIA 568-C.3 • IEC/EN 61754-7 CAT 5e Copper Cabling System Features & Benefits Voice System Solutions • Used for a rack or cabinet inside the equipment connection, realizing fast connection between devices and decrease the cost of installation • Provide 12 core connection transformation of MPO connector to the LC • MPO provides traction network, convenient construction and protection for the plug when wiring • Easy for installation and protection Fibre Cabling System Product Performance Multi mode: 50/125 (OM3) Fibre Type Single mode: G652.D ≤0.3 Return Loss (dB) ≥40 ILC Patch Cord Length 1m Fibre Core Operating Temperature MPO Connector Fibre Accessories Insertion Loss (dB) 12 core -20℃~60℃ Moble B Ordering Information Part No. Description VCS908-B20-X MPO-LC Fast Termination Optical Fibre Patch Cord(Single Mode, X m) VCS908-BM3-X MPO-LC Fast Termination Optical Fibre Patch Cord(Multi Mode, OM3, X m) Note:X denotes length www.vivanco.asia 083 Fibre Cabling System MPO-LC Fast Termination Distributor Box & MPO Optical Fiber Patch Panel MPO-LC FAST TERMINATION DISTRIBUTOR BOX Compliance • ISO/IEC11801:2008 • ANSI/TIA/EIA 568-C.3 • IEC/EN 61754 Features & Benefits • High density, modular design, plug and play, meeting requirem ents for fast deployment in data center • Available 12 or 24 core configuration • Plug type installation reduces installation time onto a fiber distribution frame • Matched connector to MPO-MPO Extender cords • Reliable transmission, performance saving installation time, suitable for rapid deployment and upgrades Product Performance Box Materials Aluminum Surface Finish Powder coated Insertion Loss (dB) ≤0.6 Return Loss (dB) ≥40 Adapter Type LC Max Fiber Count 24 Ordering Information Part No. Description VCS908-C2D-12 MPO-LC Fast Termination Distributor Box (single mode, OS2, 12 core) VCS908-CM3-12 MPO-LC Fast Termination Distributor Box (multi mode, OM3, 12 core) VCS908-C2D-24 MPO-LC Fast Termination Distributor Box (single mode, OS2, 24 core) VCS908-CM3-24 MPO-LC Fast Termination Distributor Box (multi mode, OM3, 24 core) Compliance MPO OPTICAL FIBER PATCH PANEL • ISO/IEC11801:2008 • ANSI/TIA/EIA 568-C.3 • IEC/EN 61754-7 Features & Benefits • 19" standard design, for various types of rack & cabinet installation • Easy maintenance • Support MPO-LC optic termination box, easy installation • 3pcs MPO-LC optic termination boxes can be loaded Physical Characteristics Main Materials Product Size (mm) Filling Panel Max Termination Box SPCC 485*44*340 (1U) Aluminum 3 Ordering Information Part No. VCS954-MPO 084 Description MPO Optical Fibre Patch Panel www.vivanco.asia CAT 6A Copper Cabling System Fibre Cabling System Optical Fibre Splice Closure & Transceiver CAT 5e Copper Cabling System • Used for outdoor overhead or underground installation and well protection for the fibre • External fasteners adopt high quality stainless steel material • Used twice pressure technology to ensure no additional attenuation • Product has repeated usage and expansion functions • Product shell is equipped with valve, easy to seal check when filling and pressure measurement • Shell is equipped with grounding extractor Product Performance Max Fibre Count 144 Impact of Seal 16N ≤2000N Voltage Resistance Strength 15KV(DC) Voice System Solutions Seal Stretch Ordering Information Description VCS905 One-in And One-out Optical Fibre Splice Closure ( 24 core to 48 core) VCS906 Two-in And Two-out Optical Fibre Splice Closure ( 24 core to 48 core) VCS907 Three-in And Three-out Optical Fibre Splice Closure ( 48 core to 144 core) Note: additional accessory required when expansion Features & Benefits 10/100M OPTICAL FIBRE TRANSCEIVER • Compliance with IEEE802.3, IEEE802.3U and IEEE802.3Z • Maximum work rate of light path and circuit is 100Mb/s • Full duplex/half duplex work type, automatic transfer function from full duplex to half duplex Fibre Cabling System Part No. CAT 6 Copper Cabling System OPTICAL FIBRE SPLICE CLOSURE Features & Benefits Construction 20 km, 40 km, 60km,100km (SM), 2km (MM) Power Supply Built-in & external 94mm*71mm*26mm Dimension Working Temperature Optical Performance 0 ℃~50℃ Working Wavelength(nm) Humidity 5%~90% Port Type Two SC and one RJ 45 Fibre Accessories Transforming Distance Power Supply Voltage 1310, 1550 (SM) 850, 1300 (MM) 110-265V AC Ordering Information Part No. Description VCSA100 10/100M Optical Fibre Transceivers (SM, external) VCSB100 10/100M Optical Fibre Transceivers (MM, external) VCSA100-1 10/100M Optical Fibre Transceivers (SM, built-in) VCSB100-1 10/100M Optical Fibre Transceivers (MM, built-in) www.vivanco.asia 085 Fibre Cabling System MPO Optical Fiber Patch Panel Features & Benefits 10/1000M OPTICAL FIBRE TRANSCEIVER • Compliance with IEEE802.3, IEEE802.3U and IEEE802.3Z • Maximum work rate of light path and circuit is 100Mb/s • Full duplex/half duplex work type, automatic transfer function from full duplex to half duplex Construction Transforming Distance 20 km, 40 km, 60km,100km (SM), 2km (MM) Power Supply Built-in & external 94mm*71mm*26mm Dimension Working Temperature Optical Performance 0 ℃~50℃ Working Wavelength(nm) Humidity 5%~90% Port Type Two SC and one RJ 45 Power Supply Voltage 1310, 1550 (SM) 850, 1300 (MM) 110-265V AC Ordering Information Part No. Description VCSA1000 100/1000M Optical Fibre Transceivers (SM) VCSB1000 100/1000M Optical Fibre Transceivers (MM) 10/100/1000M OPTICAL FIBRE TRANSCEIVER Features & Benefits • Compliance with IEEE802.3, IEEE802.3U and IEEE802.3Z • With 10/100 or 100/1000 m adaptive, full/half duplex adaptive function • Unique caching technology ensures that your network in data transmission is more stable, with 2m cache • Automatic identification of cross and straight line • New lightning protection function ensures the equipment safety Construction Transforming Distance 10/100 100/1000 20 km, 40 km, 60km, 100km (SM), 2km (MM) 20 km, 40 km, 60km, 80km (SM), 550m (MM) Power Supply Dimension Built-in & external 94mm*71mm*26mm Ordering Information Working Temperature 0 ℃~50℃ Humidity 5%~90% Part No. Description Port Type Two SC and one RJ 45 VCSD100 10/100M Optical Fibre Transceivers (SM) VCSM100 10/100M Optical Fibre Transceivers (MM) VCSD1000 100/1000M Optical Fibre Transceivers (SM) VCSM1000 100/1000M Optical Fibre Transceivers (MM) Optical Performance Working Wavelength(nm) Power Supply Voltage 086 1310, 1550 (SM) 850, 1300 (MM) 110-265V AC www.vivanco.asia CAT 6A Copper Cabling System Fibre Cabling System Fibre Optical Transceiver Rack & Fibre Optical PLC Splicer CAT 5e Copper Cabling System • Support hot-plugging, choosing single power supply or dual power supply mode. Dual power supply mode in accordance with powder reduction prolongs the service life of power supply • With over voltage protection, over current protection and short circuit protection function • Be up to 16 mm 10/100 or 100/1000 Fibre Optical Transceive • Has the stable work, power supply capacity is big, easy operation, easy maintenance, etc Product Performance 16 Size 19" Dimension Voice System Solutions Slot 485*245*90mm, 2U Storage Temperature -20℃~70℃ Working Temperature 0℃~50℃ Humidity 5%~95% CAT 6 Copper Cabling System FIBRE OPTICAL TRANSCEIVER RACK Features & Benefits Optical Performance Power Supply AC 100-260V, 50-60Hz DC+5V Power Out Ordering Information Description SC160-1 16 Slot Fibre Optical Transceiver Rack (single power) SC160-2 16 Slot Fibre Optical Transceiver Rack (dual power) Features & Benefits FIBRE OPTICAL PLC SPLICER •PLC Splicer is mainly used with the passive optical network (EPON and GPON) connection board, terminal equipment and optical signal shunt Fibre Accessories Features & Benefits • Loss is not sensitive to transmit light wavelengt which meets the needs of the different wavelength of transmission • Signal can be evenly assigned to users • Compact structure and small size can be directly installed on the existing transition box Optical Performance Insersion Loss (dB) ≤14.5 Return Loss (dB) ≥50 Working Wave Uniformity Fibre Cabling System Part No. 1260~1650 1.4 Ordering Information Part No. Description S970A Fibre Optical PLC Splicer (1x16) www.vivanco.asia 087 Fibre Cabling System Optcial Fibre Patch Cord Compliance • ISO/IEC11801 2008; • ANSI/TIA/EIA 568-C.3; • IEC 61754 • IEC 61300 Features & Benefits • Available in simplex and duplex format • Choose from OM2, OM3 or OS2 fibre • Choose from PC and APC • Customized in color and length Construction Color Cable Diameter(mm) Length(m) Jacket Flammability Fibre Performance Operating Temperature Yellow(Singlemode); Orange(Multimode) Simplex 2.8(±0.1); Duplex 2.8*2(±0.1) Customized LSZH IEC 60332-1 Meet the requirement -20℃~60℃ Insertion Strength ≤19.6N Pulling Force ≤19.6N Axial Tensile Strength ≥40N Optical Performance ≤0.3 (SM) Insertion Loss(db) ≤0.2 (MM) Return Loss(db) ≥35 Insertion Loss Variation(db) ≤0.2 Return Loss Variation(db) 088 ≤5 www.vivanco.asia CAT 6A Copper Cabling System Fibre Cabling System Loptcial Fibre Patch Cord CAT 6 Copper Cabling System Name Coding VC FC XX X P XX LS TYPE JACKET LENGTH S= Simplex P=PC S2=OS2 LS=LSZH 60332-1 3=3m SC=SC-SC D=Duplex U=UPC M1=OM1 A=APC M2=OM2 TYPE CONNECTOR STYLE ST=ST-ST FC=FC-FC M3=OM3 CL=SC-LC M4=OM4 CAT 5e Copper Cabling System FIBRE TYPE LC=LC-LC CONNECTOR TYPE FC = Fibre Patch Cord 3 LT=LC-ST LF=LC-FC TC=ST-SC Voice System Solutions TF=ST-FC Fibre Cabling System Ordering Information SC-ST SC-LC ST-LC Type Type Jacket/ Connector Style/Length VCFCSTSP S2LS3 VCFCLCSP S2LS3 VCFCTCSP S2LS3 VCFCCLSP S2LS3 VCFCLTSP S2LS3 Simplex OS2 LSZH /PC/3m VCFCSCSP M1LS3 VCFCSTSP M1LS3 VCFCLCSP M1LS3 VCFCTCSP M1LS3 VCFCCLSP M1LS3 VCFCLTSP M1LS3 Simplex OM1 LSZH /PC/3m VCFCFCSP M2LS3 VCFCSCSP M2LS3 VCFCSTSP M2LS3 VCFCLCSP M2LS3 VCFCTCSP M2LS3 VCFCCLSP M2LS3 VCFCLTSP M2LS3 Simplex OM2 LSZH /PC/3m VCFCFCSP M3LS3 VCFCSCSP M3LS3 VCFCSTSP M3LS3 VCFCLCSP M3LS3 VCFCTCSP M3LS3 VCFCCLSP M3LS3 VCFCLTSP M3LS3 Simplex OM3 LSZH /PC/3m VCFCFCSP M4LS3 VCFCSCSP M4LS3 VCFCSTSP M4LS3 VCFCLCSP M4LS3 VCFCTCSP M4LS3 VCFCCLSP M4LS3 VCFCLTSP M4LS3 Simplex OM4 LSZH /PC/3m VCFCFCDP S2LS3 VCFCSCDP S2LS3 VCFCSTDP S2LS3 VCFCLCDP S2LS3 VCFCTCDP S2LS3 VCFCCLDP S2LS3 VCFCLTDP S2LS3 Duplex OS2 LSZH /PC/3m VCFCFCDP M1LS3 VCFCSCDP M1LS3 VCFCSTDP M1LS3 VCFCLCDP M1LS3 VCFCTCDP M1LS3 VCFCCLDP M1LS3 VCFCLTDP M1LS3 Duplex OM1 LSZH /PC/3m VCFCFCDP M2LS3 VCFCSCDP M2LS3 VCFCSTDP M2LS3 VCFCLCDP M2LS3 VCFCTCDP M2LS3 VCFCCLDP M2LS3 VCFCLTDP M2LS3 Duplex OM2 LSZH /PC/3m VCFCFCDP M3LS3 VCFCSCDP M3LS3 VCFCSTDP M3LS3 VCFCLCDP M3LS3 VCFCTCDP M3LS3 VCFCCLDP M3LS3 VCFCLTDP M3LS3 Duplex OM3 LSZH /PC/3m VCFCFCDP M4LS3 VCFCSCDP M4LS3 VCFCSTDP M4LS3 VCFCLCDP M4LS3 VCFCTCDP M4LS3 VCFCCLDP M4LS3 VCFCLTDP M4LS3 Duplex OM4 LSZH /PC/3m SC-SC VCFCFCS PS2LS3 VCFCSCSP S2LS3 VCFCFCSP M1LS3 ST-ST Fibre Accessories LC-LC FC-FC *Other lengths are also available upon request www.vivanco.asia 089 Accessories VIVANCO offers various pratical accessories for installation requirements that is highly efficient and convenient • M odular Plug ---------------------------------------------------------- 092 • Faceplate -------------------------------------------------------------- 092 • Floor Socket ---------------------------------------------------------- 096 • WIFI Solution --------------------------------------------------------- 097 www.vivanco.asia CAT 6A Copper Cabling System Accessories CAT 6 Copper Cabling System INTRODUCTION Wall Plate • Available in shutter and non shutter version • Option for 2 to 4 port • Excellent design and finish CAT 5e Copper Cabling System Vivanco has developed a wide range of accessories that augment customer customer cabling infrasturucture needs. The design of these accessories are carefully thought out and they include wall plate/face plate, back boxes for wall plates, plugs, surface mount boxes and floor sockets. Back Box • Can be used with 86mm*86mm wall plate Voice System Solutions Surface Mount Box • Available from 2 to 6 port version • Can be mounted directly with no additional accessory • Ample space for slack cable Multimedia Outlet Box • Connect both optical fibre and copper cable Fibre Cabling System Floor Socket • Single button release flush design • Dust proof and water resistant • Multimedia connectivties: power, audio, video and data Fibre Accessories Plug • Shielded and unshielded options available • Support voice and data applications and comply to CAT 3 CAT 5e, CAT 6 and CAT 6A Accessories www.vivanco.asia 091 Accessories Modular Plug & 86 Format Faceplate MODULAR PLUG Features & Benefits • Material: polycarbonate • Reed: phosphor bronze Ordering Information Part No. Description VCR6A1 CAT 6A Modular Plug Shielded VCR600 CAT 6 Modular Plug Unshielded VCR601 CAT 6 Modular Plug Shielded VCR5E0 CAT 5e Modular Plug Unshielded VCR5E1 CAT 5e Modular Plug Shielded VCR300 Telephone Plug Features & Benefits 86 FORMAT FACEPLATE • Compatible to RJ45 jack • Dust proof • Combination structure, avoid screws exposure • Compatible to 86 back box • Color: white Ordering Information 092 Part No. Description VCA11 1 Port Faceplate VCA22 2 Port Faceplate VCA10 1 Port Faceplate ( With Label Management) VCA20 2 Port Faceplate ( With Label Management) www.vivanco.asia CAT 6A Copper Cabling System Accessories Optical Fibre Faceplate & Back Box • 45° angled outlet provides strain free patching • Faceplate surrounds effectively conceal screw holes for aesthetically pleasing outlook CAT 5e Copper Cabling System • Supports fiber connectivity to the wall pate • Compatible to 86mm*86mm back box • ABS material for durability • Color: white CAT 6 Copper Cabling System OPTICAL FIBRE FACEPLATE Features & Benefits Voice System Solutions Ordering Information Part No. Description VCFP7012 Optical Fibre Faceplate,1 Port SC/LC VCFP7022 Optical Fibre Faceplate,2 Port SC/LC VCFP7032 Angled Optical Fibre Faceplate,SC/LC VCFP7042 Angled Optical Fibre Faceplate,(SC Duplex/LC Quadplex) Fibre Cabling System Features & Benefits A FORMAT FACEPLATE Features & Benefits BACK BOX Features & Benefits Features & Benefits • Work with RJ45 jack • Offer 1, 2, 4 port • Material: ABS • Color: white • Compatible with 86mm*86mm type faceplate • Material: ABS • Color: porcelain white Fibre Accessories Accessories Ordering Information Part No. Description Ordering Information VCA171 1 Port Faceplate (A-Format) Part No. Description VCA172 2 Port Faceplate (A-Format) VCB111 Back box, 86*86*32mm VCA174 4 Port Faceplate (A-Format) VCB121 Back box, 86*86*42mm www.vivanco.asia 093 Accessories TV Faceplate & Surface Mount Box TV FACEPLATE Features & Benefits • Support connection of computer and telephone plugs • Modular design, 86 type back box • Material: ABS Ordering Information Part No. Description VCA13 TV Faceplate, 1 Port, 86*86mm VCA23 TV Faceplate, 1 Port, 86*86mm VCA33 TV Faceplate With TV and Data Port, 86*86mm SURFACE MOUNT BOX Features & Benefits • Small size, aesthetically pleasing • Magnetically mount to the desk or fixed with screws • Material:ABS • Color: white Ordering Information 094 Part No. Description VCB211 1 Port Surface Box VCB221 2 Port Surface Box VCB241 4 Port Surface Box VCB261 6 Port Surface Box www.vivanco.asia CAT 6A Copper Cabling System Accessories Optical Fibre Outlet Box & Multimedia Box • Supports fibre to the desk • Used either separately or with 86 type back box • Allowance for ample fibre bend radius • Material: ABS CAT 6 Copper Cabling System OPTICAL FIBRE OUTLET BOX Features & Benefits CAT 5e Copper Cabling System Voice System Solutions Ordering Information Part No. Description VCFP8012 Optical Fibre Outlet Box 86.7*86.7*23.6mm, 2 Port SC VCFP8022 Optical Fibre Outlet Box 86.7*86.7*23.6mm, 2 Port LC Duplex Fibre Accessories • Supports the connection of data cables, FTTH cables and other indoor fibre cables at the same time. • Support both direct fibre connection & fusion splicing, meet the requirements of fiber bend radius • Work with 86 type back box • Can be fitted with 2 pcs SC/LC duplex adapter and 1 pc keystone jack • Material: ABS Fibre Cabling System MULTIMEDIA BOX Features & Benefits Accessories Ordering Information Part No. Description VCFP8032 Multimedia Box , for 2 PCS Simplex SC/Duplex LC and 1 PC Keystone Jack www.vivanco.asia 095 Accessories Floor Socket Features & Benefits • Precision cast with a specially polished surface, showing sturdiness and exquisite beauty • Nicely flushed when closed • Anti dust and water-proof enclosure • After installation almost flushed with ground surface • Floor socket are spring loaded • Material: copper alloy VCG104 VCG106 VCG107 VCG111 VCG112 VCG113 Ordering Information 096 Part No. Description VCG104 Floor Socket, Three RJ45, 100*100*55mm VCG106 Floor Socket, Three RJ45, 100*100*55mm VCG107 Floor Socket, Four RJ45, 154*146*60mm VCG111 Floor Socket, Three RJ45, 100*100*55mm VCG112 Floor Socket, Four RJ45, 135*135*65mm (none spring style) VCG113 Floor Socket, Six RJ45, Four Three Pin,135*260*65mm (none spring style) www.vivanco.asia CAT 6A Copper Cabling System Accessories Wireless Access Controller CAT 6 Copper Cabling System The product has eight gigabit port, supporting full speed non-blocking data forwarding. Specially designed for large wireless network which can be deployed in any layer network layer, without changing of existing network architecture and provides seamless, and secures wireless network management system. It is geared to meet the needs of a new generation of high-speed wireless network, based on the industry's CAT 5e Copper Cabling System Features & Benefits leading multi core processor architecture design, provide powerful data processing ability and expansion capacity with a high capacity AP Voice System Solutions management, high processing power and performance, features, etc.. Product Specifications Size (mm) 440x300x44 1U Weight <5kg Fibre Cabling System Management Port 1* Console Port 8* 10/100/1000M Port Working Port Range of rated voltage: 100V~240V AC; 50/60Hz Input Voltage Range of max. voltage: 90V~264V AC; 47/63Hz Operating Environment Humidity 10%~95% (non-condensing) -10℃~55℃ Storage Temperature -40ºC~70ºC Storage Humidity 5%~95% (non-condensing) Max Manageable AP Quantity 512 License Step Length (AP Quantity) 32 Accessories Max User Quantity Fibre Accessories Operating Environment Temperature 10240 Ordering Information Part No. Description VCA165-6000C Wireless Access Controller www.vivanco.asia 097 Accessories Ceiling AP Features & Benefits • Indoor wireless access point meeting 802.11 a, standard, uses CCK/DSSS, OFDM technology, supporting rate of up to 150 Mbps connection. Power of 500 mw allow wireless penetration 2-3 times better than common indoor AP. • Use NI classic design type suction, aeshetically pleasing and can be embedded in the ceiling. Product Specifications Maximum Access Rate Maximum Output Power Power Supply Size (mm) 150Mbps 500mW/27dBm Maximum output power or DC 12V (1.5A) D: 190 mm, H: 62mm Ethernet Port 10/100Mbps Telephone Port Max27dBm Operating Temperature Operating Humidity Storage Temperature Storage Humidity -10℃~55℃ 5%~95% (noncondension) -40℃~70℃ 5%~ 95% (noncondension) Ordering Information 098 Part No. Description VCA165-3 Ceiling AP ( FIT Type ) www.vivanco.asia CAT 6A Copper Cabling System Accessories 86 Face Plate Type Access Point CAT 6 Copper Cabling System CAT 5e Copper Cabling System Features & Benefits Voice System Solutions • POE power supply, cleverly hidden behind a UK-sized faceplate, eliminates the need for power cabling. It can be retrofitted to existing network cabling saving deployment costs. • Optional POE power supply module are available depending on requirements. Supports management functions such as bi-directional sending of server configuration, log management and automatic uploading and other functions. Fully compatible with common network operating systems with easy and simple network maintenance. Product Specifications Maximum Output Power 150Mbps 100mW/20dBm Power Supply POE power supply (IEEE 802.3af ) Size(mm) 86mm*86mm*48mm Ethernet Port 1WAN port (10/100 - BaseTX) (rear) ; 1LAN port (10/100 - BaseTX) (front) 1 ptandard RJ11 telephone port (front) ; 1 port (rear) Output Power Max 20dBm Operating Temperature -10℃~45℃ Storage Temperature 10%~ 90% (noncondension) -40℃~85℃ Accessories Storage Humidity Fibre Accessories Telephone Port Operating Humidity Fibre Cabling System Maximum Access Rate 10%~ 90% (noncondension) Ordering Information Part No. Description VCA165-1 86 Face Plate Type Access Point VCA165-2 86 Face Plate Type Access Point( FIT type ) www.vivanco.asia 099 Cabinets & Racks VIVANCO offers cabinets and racks system solution in data center,e quipment room etc. for easy installation and fast management. • VB Server Cabinet Solution ------------------------------------------------ 102 • VE Networks Cabinet Solution ---------------------------------------------104 • VA Wall Mount Cabinet Solution -----------------------------------------106 • V6 Open Rack Solution ----------------------------------------------------- 108 • Cabinet Accessories --------------------------------------------------------- 109 www.vivanco.asia CAT 6A Copper Cabling System Cabinets & Racks Cabinets CAT 6 Copper Cabling System INTRODUCTION VE Series • Comply to ANSI/EIA RS-310-D, IEC60297-2, DIN41494 part 1, DIN41494 part 7 • Various configuration in combination of 600, 800 and 1000mm • 1300 kg maximum static loading • Precise dimension • Cable entry from top or bottom with adjustable sizes • Various options on front & back door • Removable side panels for easy maintenance Fibre Cabling System VA Series • Comply to ANSI/EIA RS-310-D, IEC60297-2, DIN41494 part 1, DIN41494 part 7 • Industry standard 19’’ wall mount cabinets • 45 kg maximum static loading • Modular design Fibre Accessories V6 Series • Comply to ANSI/EIA RS-310-D, IEC60297-2, DIN41494 part 1, DIN41494 part 7 • Industry standard 19’’ open rack • 150 kg maximum static loading • Modular design • Multiple accessories available including cable manager Cabinets & Racks www.vivanco.asia Accessories • 2/4 fan unit • I9” fan unit • 3U fan unit • Cooling fan • Fixed shelf • Cantilever shelf with holes • Cantilever Shelf without venetilation holes • Double sided shelf • Sliding shelf • Rock mountable drawer • Steel blanking panel • Aluminum blanking panel • L bracket • Plinth • Steel cable management • Plastic cable management • Castor wheel • Castor wheel with braking • M12 Adjustable feet • Baying kit • Earthing kit • T30 torx tool • M6 screws & nets • M6 cushion Voice System Solutions Accessories VB Series • Comply to ANSI/EIA RS-310-D, IEC60297-2, DIN41494 part 1, DIN41494 part 7 • Unique nine bend style frame • Various configuration in combination of 600, 800 and 1000mm • 1600 kg maximum static loading • Precise dimension • Cable entry from top or bottom • Removable side panels for easy maintenance • Vented door, slotted surface perforation >70% CAT 5e Copper Cabling System Vivanco manufactures cabinets complying to ANSI/EIA RS-310-D, IEC60297-2, DIN41494 part 1, DIN41494 part 7 in wall mount and floor mount version. The VE and VB series of cabinets offer greater flexibility for installing various networking accessories like network switches, server farms and other various accessories. Designed with customer ease of maintenance in mind these cabinets come with host of optional accessories and features. The rapid series of wall mount cabinets are available in various configurations offering a host of features enabling ease of installation and maintenance. Vivanco also offers open racks for customer cabling infrastructure. 101 Cabinets & Racks VB Heavy Duty Cabinet Compliance •ANSI/EIA RS-310-D •IEC60297-2 •DIN41494 PART1 •DIN41494 PART7 Features & Benefits High-density vented door, rear door could open from the left or right side; slotted surface (SW7 hexagon) perforation>70%, high strength 19’’ rails, SPCC cold rolled steel, powder coated; fan units installed from top, easy installation; reserved room for earth kit to meet the system requirement. Specification 19’’ standard structure, one time forming with nine-bending style of metal, 1600kg maximum static loading, 180° maximum opening angle of front and rear door, removable side panels for easy maintenance Material • SPCC cold rolled steel • 19’’ rails: 2.0mm; frame:1.5mm; Side panel / Top cover / Front door / Rear door 1.2mm Colour • VBXXXXXX0XX:RAL7035white • VBXXXXXX1XX:RAL7021black Item S/N Specification 1 Side panel High-density vented rear 2 door with left or right opening 102 3 Frame 4 Top cover 5 19’’ rails 6 High-density vented front door 7 2” heavy duty castor www.vivanco.asia CAT 6A Copper Cabling System Cabinets & Racks VB Heavy Duty Cabinet CAT 6 Copper Cabling System Naming Coding VB X CABINET DEPTH 6=600 8=800 8=800 X CABINET CAPACITY FRONT DOOR (U) 5=high-density Vented Door X X 00 REAR DOOR COLOR 5= High-density Vented Front Door 0=RAL7035 White 6= High-density Vented Door With Left Or Right Opening 0=1000 CAT 5e Copper Cabling System CABINET WIDTH 6=600 X XX 1=RAL7021 Black Voice System Solutions Fibre Cabling System Fibre Accessories Ordering Information Specification Part No. Size(Width*Depth*Height)mm Accessories VB.6642.55. X00 Capacity (U) 600*600*2000 VB.6642.56. X00 VB.6842.55. X00 600*800*2000 VB.6842.56. X00 VB.6042.55. X00 42U 600*1000*2000 VB.8042.55. X00 800*1000*2000 VB.8042.56. X00 size and capacity can be customized www.vivanco.asia 103 Cabinets & Racks VB.6042.56. X00 Cabinets & Racks VE Heavy Duty Cabinet Compliance •ANSI/EIA RS-310-D •IEC60297-2 •DIN41494 PART1 Features & Benefits 180° maximum opening angle, removable side panels; slotted surface perforation>70%; zinc 19’’ rails, SPCC cold rolled steel, powder coated; fan units installed on the top of the cabinet, easy installation. •DIN41494 PART7 Specification 19’’ standard structure, assembling-style frame, only 8 screws and nuts used for assembling, 1300kg maximum static loading 6 5 3 2 7 Material 4 10 • SPCC cold rolled steel • 19’’ rails: 2.0mm; frame:1.5mm; Side panel / Top cover / Front door / Rear door 1.2mm Colour 8 • VBXXXXXX0XX:RAL7035 white • VBXXXXXX1XX:RAL7021 black 1 9 11 12 Item 104 S/N Specification 1 Front door 2 Front frame 3 Side frame 4 Side panel 5 Rear door 6 Top cover 7 19’’ rails 8 Bottom 9 Castor plinth 10 Cable slot 11 2’’ heavy duty castor 12 M12 adjustable feet www.vivanco.asia CAT 6A Copper Cabling System Cabinets & Racks VE Heavy Duty Cabinet CAT 6 Copper Cabling System Naming Coding VE X CABINET DEPTH 6=600 8=800 8=800 0=1000 CABINET CAPACITY (U) X X X 00 FRONT DOOR 1= Tempered Glass Door With Striped Hole 5= High-density Vented Door REAR DOOR 3= Sheet Steel Door 5= High-density Vented Front Door COLOR CAT 5e Copper Cabling System CABINET WIDTH 6=600 X XX 0=RAL7035White 1=RAL7021Black 6= High-density Vented Door, Open From The Left Or Right Side Voice System Solutions Ordering Information Specification Part No. Capacity (U) 600*600*1200 24 600*600*2000 42 600*800*1200 24 600*800*2000 42 600*1000*2000 42 800*800*2000 42 800*1000*2000 42 Fibre Cabling System Size(Width*Depth*Height)mm VE.6624. 13. X00 VE.6624. 55. X00 VE.6624. 56. X00 VE.6642. 13. X00 VE.6642. 55. X00 VE.6642. 56. X00 Fibre Accessories VE.6824. 13. X00 VE.6824. 55. X00 VE.6824. 56. X00 VE.6842. 13. X00 VE.6842. 55. X00 VE.6842. 56. X00 VE.6042. 13. X00 Accessories VE.6042. 55. X00 VE.6042. 56. X00 VE.8842. 13. X00 VE.8842. 55. X00 VE.8842. 56. X00 VE.8042. 56. X00 size and capacity can be customized www.vivanco.asia 105 Cabinets & Racks VE.8042. 13. X00 VE.8042. 55. X00 Cabinets & Racks VA Wall Mount Cabinet Compliance •ANSI/EIA RS-310-D •IEC60297-2 •DIN41494 PART1 •DIN41494 PART7 Features & Benefits Tempered glass front door can be opened with left or right side hinges, automatic lock; SPCC cold rolled steel, powder coated, top, bottom and back fitted with mounting holes; lockable side panels can be easily removed. Specification 19’’ standard structure, only 16 screws and nuts used for assembling; 45kg maximum static loading Material • SPCC cold rolled steel • 19’’ rails 2.0 mm, others: 1.0mm Colour • VBXXXXXX0XX:RAL7035 white • VBXXXXXX1XX:RAL7021 black Item 106 S/N Specification 1 Side frame 2 Bottom frame 3 Top frame 4 Front door 5 19” rails 6 Side panel www.vivanco.asia CAT 6A Copper Cabling System Cabinets & Racks VA Wall Mount Cabinet CAT 6 Copper Cabling System Naming Coding VA X CABINET DEPTH 4=450 CABINET CAPACITY (U) 6=600 X X 00 COLOR FRONT DOOR 1= Tempered Glass Door With Striped Hole CAT 5e Copper Cabling System CABINET WIDTH 5=540 X XX 0=RAL7035White 1=RAL7021Black Voice System Solutions Fibre Cabling System Fibre Accessories Ordering Information Specification Part No. Size(Width*Depth*Height)mm VA.5606.01. X00 540*600*327 VA.5409.01. X00 540*450*460 VA.5609.01. X00 540*600*460 VA.5412.01. X00 540*450*593 VA.5612.01. X00 540*600*593 VA.5415.01. X00 540*450*726 VA.5615.01. X00 540*600*726 6 9 12 15 size and capacity can be customized www.vivanco.asia 107 Cabinets & Racks 540*450*327 Accessories VA.5406.01. X00 Capacity (U) Cabinets & Racks V6 Heavy Duty Cabinet Compliance •ANSI/EIA RS-310-D •IEC60297-2 2 •DIN41494 PART1 1 •DIN41494 PART7 Specification 19” standard structure, can be assembled in field, full assembling design; cable management slot, SPCC cold rolled steel, 150kg maximum static loading Colour • VBXXXXXX0XX:RAL7035 white • VBXXXXXX1XX:RAL7021 black 3 Material • SPCC • Column: 1.5mm, others: 2.0mm Item S/N Features & Benefits • Modular design, can be easily assembled or dismantled in field • Various optional accessories according to requirements Specification 1 Column 2 Frame 3 Plinth Naming Coding V6 X CABINET WIDTH(mm) 6=600 CABINET DEPTH(mm) 4=404 X XX CABINET CAPACITY X X 00 FRONT/REAR DOOR 00=N/A (U) COLOR 0=RAL7035white 1=RAL7021black Ordering Information Specification Part No. Size(Width*Depth*Height)mm Capacity (U) V6.6429.00.X00 600*404*1397 29 V6.6442.00.X00 600*404*1975 42 size and capacity can be customized 108 www.vivanco.asia CAT 6A Copper Cabling System Cabinets & Racks Accessories CAT 6 Copper Cabling System Specification Color •For VIVANCO cabinets, providing ventilation and reliable operation easy to install from the top of cabinet •VC70XXXX0XX:RAL7035 white •VC70XXXX1XX:RAL7021 black •Fan size:120*120*38mm, cable length:1.9m •Rated voltage (Un)/: 220V/50Hz •Operating temperature: -10~50℃ •Material: SPCC 1.2mm CAT 5e Copper Cabling System FAN UNIT, 2 POSITION FAN UNIT, 4 POSITION Voice System Solutions Fibre Cabling System Fibre Accessories Ordering Information Connector Type VC700402X11 2 Fan UK Type (BS1363) VC700402X12 2 Fan German Type (DIN49441) VC700402X13 2 Fan US Type (NEMA5-15P) VC700404X11 4 Fan UK Type (BS 1363) VC700404X12 4 Fan German Type (DIN49441) VC700404X13 4 Fan US Type (NEMA5-15P) www.vivanco.asia Cabinets & Racks Specification Accessories Part No. 109 Cabinets & Racks Accessories Specification Color 19” standard installation, 1U fan units switch control fans work •VC70XXXX0XX:RAL7035 white •Fan size:120*120*38mm, cable length:1.9m •VC70XXXX1XX:RAL7021 black •Rated voltage (Un)/Frequency: 220V/50Hz •Operating temperature: -10~50℃ •Material: SPCC 1.0mm FAN UNIT, RACK MOUNT, 1U Ordering Information 110 Part No. Specification Connector Type VC700402X21 2 Fan UK Type (BS1363) VC700402X22 2 Fan German Type (DIN49441) VC700402X23 2 Fan US Type (NEMA5-15P) VC700403X21 3 Fan UK Type (BS 1363) VC700403X22 3 Fan German Type (DIN49441) VC700403X23 3 Fan US Type (NEMA5-15p) VC700404X21 4 Fan UK Type (BS1363) VC700404X22 4 Fan German Type (DIN49441) VC700404X23 4 Fan US Type (NEMA5-15P) www.vivanco.asia CAT 6A Copper Cabling System Cabinets & Racks Accessories CAT 6 Copper Cabling System FAN UNIT Specification 19” standard installation, 3U fan units •Fan size:120*120*38mm, cable length:1.9m •Rated voltage (Un)/ Frequency: 220V/50Hz •Operating temperature: -10~50℃ •Material: SPCC 1.2mm CAT 5e Copper Cabling System Color •VC70XXXX0XX:RAL7035 white •VC70XXXX1XX:RAL7021 black Ordering Information Connector Type VC700402X31 2 Fan UK Type(BS1363) VC700402X32 2 Fan German Type(DIN49441) VC700402X33 2 Fan US Type(NEMA5-15P) VC700404X31 3 Fan UK Type(BS 1363) VC700404X32 3 Fan German Type(DIN49441) VC700404X33 3 Fan US Type(NEMA5-15p) FAN UNIT, SINGLE Fibre Cabling System Specification Voice System Solutions Part Number Specification •For network cabinet, adjust inner temperature Fibre Accessories •Performance reference. •Size:120*120*38mm •Atmosphere runoff:50CFM, noise: 24.9 dB •Operating temperature: -10~50℃ Accessories Ordering Information Part No. Description Input(v) Ac Fan 220 VC701022002 Dc Fan 12 www.vivanco.asia Cabinets & Racks VC701022000 111 Cabinets & Racks Accessories FIXED SHELF Specification • Used for VIVANCO 19’’ cabinets, side installation • Static load capacity: 90kg • Material: SPCC 1.2mm Color • VC70XXXX0XX: RAL7035 white • VC70XXXX1XX: RAL7021 black Ordering Information Description(mm) Part No. Width Depth Application VC700160X00 489 350 600 cabinet VC700180X00 489 500 800 cabinet VC700190X00 489 600 900 cabinet VC700110X00 489 700 1000 cabinet CANTILEVER SHELF, WITH HOLES Specification • Used for Vivanco 19’’ network cabinets and racks, front installation • Material: SPCC 1.5mm Color • VC70XXXX0XX:RAL7035 white • VC70XXXX1XX:RAL7021 black Ordering Information 112 Part No. Description Static loading capacity VC701401X02 1U-6"DP 5kg VC701401X01 1U-10"DP 10kg VC701402X05 2U-12"DP 22kg VC701402X04 2U-14"DP 22kg VC701402X01 2U-16"DP 22kg VC701402X06 2U-18"DP 22kg VC701403X01 3U-16"DP 36.3kg VC701403X02 3U-18"DP 36.3kg www.vivanco.asia CAT 6A Copper Cabling System Cabinets & Racks Accessories • Used for Vivanco 19’ network cabinet, side installation • Sliding shelf extends to 260mm • Material: SPCC 1.2mm • Static loading capacity: 30kg CAT 6 Copper Cabling System SLIDING SHELF Specification CAT 5e Copper Cabling System Color • VC70XXXX0XX: RAL7035 white • VC70XXXX1XX: RAL7021 black Voice System Solutions Ordering Information Part No. Description Width (mm) Depth (mm) Cabinet Type VC700235X00 350 440 350 600~800 VC700255X00 550 440 550 900~1100 • Used for 19’ network cabinets and racks • Sliding shelf extends to 450mm Fibre Cabling System DRAWER, RACK MOUNT Specification • Material: SPCC 1.2mm • Static loading capacity: 35kg Fibre Accessories Color • VC70XXXX0XX:RAL7035 white • VC70XXXX1XX:RAL7021 black Accessories Ordering Information Description VC702302X00 2U-18" VC702303X00 3U-18" www.vivanco.asia Cabinets & Racks Part No. 113 Cabinets & Racks Accessories Specification CANTILEVER SHELF, WITHOUT HOLES • Used for Vivanco 19” network cabinets and racks • Material: SPCC 1.0mm Color • VC70XXXX0XX:RAL7035 white • VC70XXXX1XX:RAL7021 black Ordering Information Part No. Description Static Loading Capacity VC701402X07 2U-10"DP 22kg VC701402X08 2U-16"DP 22kg FIXED SHELF, DOUBLE SIDED Specification • Used for Vivanco 19’’ open racks, 2U height • Material: SPCC 1.5mm Color • VC70XXXX0XX:RAL7035 white • VC70XXXX1XX:RAL7021 black Ordering Information 114 Part No. Description Static Loading Capacity VC701402X02 2U-19"DP 50kg www.vivanco.asia CAT 6A Copper Cabling System Cabinets & Racks Accessories • Used for Vivanco 19’’ cabinets and wall boxes • Material: SPCC 1.5mm • Static loading capacity: 15kg CAT 6 Copper Cabling System L BRACKET Specification CAT 5e Copper Cabling System Color • VC70XXXX0XX:RAL7035 white • VC70XXXX1XX:RAL7021 black Ordering Information Voice System Solutions Description Part No. Description Length (mm) Cabinet Type VC701360X00 60 Type 320 600mm Cabinet VC701380X00 80 Type 500 800mm Cabinet VC701390X00 90 Type 600 900mm Cabinet VC701310X00 10 Type 700 1000mm Cabinet • Used for Vivanco 19’’ VE cabinets • Material: SPCC 1.2mm Fibre Cabling System PLINTH Specification • Static loading capacity: 1300kg Fibre Accessories Color • VC70XXXX0XX:RAL7035 white • VC70XXXX1XX:RAL7021 black Ordering Information Depth Height VC702266X10 600 600 100 VC702268X10 600 800 100 VC702269X10 600 900 100 VC702260X10 600 1000 100 VC702286X10 800 600 100 VC702288X10 800 800 100 www.vivanco.asia Cabinets & Racks Width Accessories Description(mm) Part No. 115 Cabinets & Racks Accessories Specification BLANK PANEL, STEEL • Compatible with 19” network cabinets • For covering unused rack spaces • Material: 1U/2U SPCC 1.0mm 3U/4U SPCC 1.2mm Color • VC70XXXX0XX:RAL7035 white • VC70XXXX1XX:RAL7021 black Ordering Information Part No. Width (mm) Height (mm) Description VC700601X00 482 44 1U VC700602X00 482 88 2U VC700603X00 482 132.5 3U VC700604X00 482 177 4U BLANK PANEL, ALUMINUM Specification • Compatible with 19” network cabinets • For covering the unused rack spaces • Material: aluminum 2.0mm Color • VC70XXXX0XX: RAL7035 white • VC70XXXX1XX: RAL7021 black Ordering Information 116 Part No. Width (mm) Height (mm) Description VC700601X01 482 44 1U VC700602X01 482 88 2U VC700603X01 482 132.5 3U VC700604X01 482 177 4U www.vivanco.asia CAT 6A Copper Cabling System Cabinets & Racks Accessories • Mountable to standard 19’’ racks and cabinets • Material: SPCC 1.0 mm /1.2 mm • Size(mm): 495*55*88mm 1U • Management port: 24 CAT 6 Copper Cabling System CABLE MANAGEMENT, STEEL Specification CAT 5e Copper Cabling System Color • Black Voice System Solutions Ordering Information Part No. Description VCCPCMNM1 Steel Cable Management • Mountable to standard 19’’ racks and cabinets • Size(mm): 482.6*44.5*83.5mm 1U Fibre Cabling System CABLE MANAGEMENT, PLASTIC Specification • Material: ABS • Management port: 24 Fibre Accessories Color • Black Accessories Ordering Information Description VCCPCMP1 Plastic Cable Management www.vivanco.asia Cabinets & Racks Part No. 117 Cabinets & Racks CASTOR WHEEL Accessories Specification • Used for 19’’ network cabinets • Static loading capacity: 250kg/pcs Color • Black • Zinc-plated Ordering Information Description Part No. VC700802000 VC700825000 2.0 inch Castor Wheel 2.5 inch VC700803000 CASTOR WHEEL WITH STOPPER 3.0 inch Specification • Used for 19’’ network cabinets • Static loading capacity: 400kg/pcs Color • Black • Zinc-plated Ordering Information Description Part No. VC700802001 VC700825001 VC700803001 118 2.0 Inch Castor Wheel With Stopper 2.5 Inch 3.0 Inch www.vivanco.asia CAT 6A Copper Cabling System Cabinets & Racks Accessories • Used for 19’’ network cabinets • Static loading capacity: 400kg/pcs CAT 5e Copper Cabling System Color • Black • Zinc-plated Voice System Solutions Ordering Information Part No. Description VC700712000 Height100mm BAYING KIT Specification Fibre Cabling System • Used for combing the cabinet accessories • VE Material: SPCC 2.0mm • VB Material:Steel 30*Φ9mm Fibre Accessories Color CAT 6 Copper Cabling System M12 ADJUSTABLE FEET Specification VC700500001 • Black (VB) • Black/White (VE) Accessories VC700500002 Ordering Information Part No. Application VB Cabinets VC700500002 VE Cabinets www.vivanco.asia Cabinets & Racks VC700500001 119 Cabinets & Racks Accessories EARTHING NG WIRE Specification • RoHS • 14 AWG 300mm length VC701603000 Color • Black VC701603001 Ordering Information Part No. Packs of VC701603000 2 VC701603001 2 T30 TORX TOOL Specification • Used for M6 screws • Size: Φ5.5*33*120 Color • Zinc plating Ordering Information 120 Part No. Description Packs of VC701901001 Torx (T30) 10 www.vivanco.asia CAT 6A Copper Cabling System Cabinets & Racks Accessories M6 SCREWS & NUTS • Phillips / Torx CAT 6 Copper Cabling System Specification CAT 5e Copper Cabling System Color • Black • Zinc-plated Voice System Solutions Ordering Information Description Packs of VC700906001 Torx (T30) 50 VC700906002 Phillips 50 Part No. • Industry Standard 19’’ • Voltage: 220V • Cable length: 1.8m Fibre Cabling System PDU Specification • Material: PC/ABS Fibre Accessories Color • Black Type Accessories • UK/US/German Ordering Information Description VC70608CS Input:10A, output: 2500W VC70609CS Input:16A, output: 4000W www.vivanco.asia Cabinets & Racks Part No. 121 Cabinets & Racks Accessories Compatibility Table Specification Part Number 122 Application VC700402X11 2 Fan Unit, Uk Type VC700402X12 2 Fan Unit, German Type VC700402X13 2 Fan Unit, Us Type VC700404X11 4 Fan Unit, Uk Type VC700404X12 4 Fan Unit, German Type VC700404X13 4 Fan Unit, Us Type VC700402X21 19“2 Fan Unit, Uk Type VC700402X22 19“2 Fan Unit, German Type VC700402X23 19“2 Fan Unit, Us Type VC700403X21 19“3 Fan Unit, Uk Type VC700403X22 19“3 Fan Unit, German Type VC700403X23 19“3 Fan Unit, Us Type VC700404X21 19“4 Fan Unit, Uk Type VC700404X22 19“4 Fan Unit, German Type VC700404X23 19“4 Fan Unit, Us Type VC700402X31 3U 2 Fan Unit, Uk Type VC700402X32 3U 2 Fan Unit, German Type VC700402X33 3U 2 Fan Unit, Us Type VC700403X31 3U 3 Fan Unit, Uk Type VC700403X32 3U 3 Fan Unit, German Type VC700403X33 3U 3 Fan Unit, Us Type VC701022000 AC 220v Fan VC701022002 DC 12v Fan VC700160X00 350 Fixed Shelf VC700180X00 550 Fixed Shelf VC700190X00 620 Fixed Shelf VC700110X00 720 Fixed Shelf VC701401X02 1u-6” Cantilever Shelf With Holes VC701401X01 1u-10” Cantilever Shelf With Holes VC701402X05 2U-12” Cantilever Shelf With Holes VC701402X04 2U-14” Cantilever Shelf With Holes VC701402X01 2U-16” Cantilever Shelf With Holes VC701402X06 2U-18” Cantilever Shelf With Holes VC701403X01 3U-16” Cantilever Shelf With Holes VC701403X02 3U-18” Cantilever Shelf With Holes VC701402X07 2U-10” Cantilever Shelf Without Ventilation Holes VB VE VA V6 www.vivanco.asia Cabling Solutions Vivanco Europe Headquarters(Germany) Ewige Weide 15, 22926 Ahrensburg E: [email protected] Vivanco Asia Headquarters(China) 7th floor, Yinzhou Chamber of Commerce Office Building (South building), Yinzhou, Ningbo, China E: [email protected] Vivanco Asia Pacific Singapore Division Block 681, Hougang Avenue 4 #03-801 Singapore 530681 Vivanco America Headquarters(USA) 10025 Investment Drive, Suite120Knoxville, Tennessee 37932 USA E: [email protected] Vivanco Middle Asia Russia Division Vivanco Middle East Dubai Division E: [email protected] E: [email protected] E: [email protected] Printed on paper made from 75% recycled fibres www.vivanco.asia www.vivanco.com CAT 6A Copper Cabling System Cabinets & Racks Accessories Compatibility Table CAT 6 Copper Cabling System Specification Part Number Application VC701402X08 2U-16” Cantilever Shelf Without Ventilation Holes VC701402X02 VB VE VA V6 2U Double Sided Shelf 350 Sliding Shelf VC700255X00 550 Sliding Shelf VC700601X00 1U Steel Blanking Panel VC700602X00 2U Steel Blanking Panel VC700603X00 3U Steel Blanking Panel 4U Steel Blanking Panel 1U Aluminum Blanking Panel VC7001602X01 2U Aluminum Blanking Panel VC7001603X01 3U Aluminum Blanking Panel VC7001604X01 4U Aluminum Blanking Panel VC701360X00 60 L Bracket VC701380X00 80 L Bracket VC701390X00 90 L Bracket VC701310X00 10 L Bracket VC702302X00 2U-18“ Rack Mountable Drawer VC702303X00 3U-18“ Rack Mountable Drawer VC702266X10 66 Plinth 68 Plinth VC702269X10 69 Plinth VC702260X10 60 Plinth VC702286X10 86 Plinth VC702288X10 88 Plinth VCCPCMNM1 Metal Cable Management VCCPCMP1 Plastic Cable Management 2.0“ Castor 2.5“ Castor 3.0“ Castor VC700802001 2.0“ Castor With Braking VC700825001 2.5“ Castor With Braking VC700803001 3.0“ Castor With Braking VC700712000 M12 Adjustable Feet VC700500001 Vb Baying Kit VC700500002 Ve Baying Kit VC701603000 Earthing Kit VC701603001 Earthing Kit VC701901001 T30 Torx Tool VC700906001 M6 Screws And Nuts VC700906002 M6 Phillips Screws VC700906010 M6 Cushion Accessories VC700803000 Fibre Accessories VC700802000 VC700825000 Fibre Cabling System VC702268X10 Voice System Solutions VC700604X00 VC7001601X01 CAT 5e Copper Cabling System VC700235X00 is applicable, blank–not applicable www.vivanco.asia 123 Cabinets & Racks Note: