Transcript
Calculite® CFL Open Downlight Page 1 of 2
8022
7 3/8" Aperture Triple Tube Vertical Lamp 14 7/8" (378mm)
26/32W=10 3/8" (264mm)
9 3/8" (238mm)
42W=11 1/8" (283mm) 11 3/4" (298mm)
3" (264mm)
7 3/8" Frame Dia. (181mm)
1 1/8" (29mm) MAX CEILING THICKNESS
8 5/8" Frame Dia. (209mm) OVERLAP
Reflector Trim
Frame-In Kit
8022 CCLW 8022 CCLP 8022 CCL 8022
S7126BU 7" aperture, 1 lamp 26W Triple Tube CFL (120/277V) 4-Pin (Amalgam) S7132BU 7" aperture, 1 lamp 26/32W Triple Tube CFL (120/277V) 4-Pin (Amalgam) S7142BU 7" aperture, 1 lamp 26/32/42W Triple Tube CFL (120/277V) 4-Pin (Amalgam)
Comfort Clear™, White Flange Comfort Clear™, Polished Flange Comfort Clear™, Molded Trim Ring Add suffix. See options for other finishes.
Dimming Options: S7132B or S7142B CU3 Lightolier PowerSpec 3% Dimming (120/277V) J1LD3 Lutron 5% Dimming (120V) J2LD3 Lutron 5% Dimming (277V) JUM7 Mark 7 Dimming (120/277V) J1MX Mark 10 Dimming (120V) J2MX Mark 10 Dimming (277V) Other dimming product available, please consult factory
Remodeler Frame-In Kits 7126BURM 7" aperture, 1 lamp 26W Triple Tube CFL (120/277V) 4-Pin (Amalgam)) 7132BURM 7" aperture, 1 lamp 26/32W Triple Tube CFL (120/277V) 4-Pin (Amalgam) 7142BURM 7" aperture, 1 lamp 26/32/42W Triple Tube CFL (120/277V) 4-Pin (Amalgam)
Features
1. Reflector: 16 ga. Alzak® aluminum, 50° visual cutoff to lamp and lamp image, medium distribution. Comfort Clear™ low iridescence finish. Self-flanged or flangeless with molded white trim ring (field paintable). 2. Socket Cup: Effectively dissipates heat and positions lamp holder. Snaps onto reflector neck to assure consistently correct optical alignment without tools. 3. Mounting Frame: Galvanized steel for dry or plaster ceilings. Accepts other 6” Triple Tube reflectors (see S6132BU Spec Sheet). 4. Retaining Springs: Precision-tooled steel friction springs secure reflector to mounting frame for quick, tool-less installation. 5. Mounting Brackets: 16 ga. steel. Adjust from inside of fixture. Use 3/4” or 1 1/2” lathing channel, 1/2” EMT, or optional mounting bars. 6. Ballast/J-Box: Electronic 120V-277V. UL listed for through branch circuit wiring with max of (8) No. 12 AWG, 90°c supply conductors. Outboard mounted to reduce heat transfer and maintain lamp efficacy and life. Service from below without tools.
Electrical
Note: Note: For ballast electrical data and latest lamp/ballast compatibility refer to “Ballast” specification sheet for complete electrical data.
Options and Accessories (continued) Emergency Ltg. Kit FA EM3E* FA EM4* Fuse (Slow Blow) Add suffix F Existing/Thk. Ceiling Plaster Trim Ring CA7FL Emergency Add suffix EM* Chicago Plenum Use 7142, BULC *See Spec. Sheets: FAEM, FAEC
Mounting Bars & Accessories; see Specification Sheet MBA. Sloped Ceiling Adapters; see Specification Sheet SCA.
Labels
UL, CUL, I.B.E.W Alzak® is a registered trademark of ALCOA
Job Information Job Name:
UL Listed for through branch circuit wiring with max of (8) No 12 AWG, 90 degree C supply conductors.
Cat. No.:
Options and Accessories
Lamp(s):
Comfort Clear™ Finishes1 Diffuse CCD Champagne Bronze CCZ Pewter CPW
Top View
Other Finishes White WH Specular Clear CL
Specify desired flange. W White, P Polished, Blank - Molded Ring
1
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2009 Philips Group • A0409
Notes:
Type:
Calculite® CFL Open Downlight Page 2 of 2 32W
Quick Calculator ROOM SURFACE REFLECTANCES:
80
70
50 40 30 20
RCR = 1 (Rm. width = 10 x Mtg. Ht. above work plane) RCR = 5 (Rm. width = 2 x Mtg. Ht. above work plane) RCR = 10 (Rm. width = Mtg. Ht. above work plane)
60
INITIAL FOOTCANDLES
RCR = 1 (Rm. width = 10 x Mtg. Ht. above work plane) RCR = 5 (Rm. width = 2 x Mtg. Ht. above work plane) RCR = 10 (Rm. width = Mtg. Ht. above work plane)
60
ROOM SURFACE REFLECTANCES: 80% Ceiling; 50% Wall; 20% Floor 3200 Lumens Per Lamp
80
80% Ceiling; 50% Wall; 20% Floor 2400 Lumens Per Lamp
70 INITIAL FOOTCANDLES
7 3/8" Aperture Triple Tube Vertical Lamp
42W
Quick Calculator
8022
50 40 30 20
10
10 20 3
40 60 80 AREA PER FIXTURE IN SQUARE FEET 7 9 6 8
5
4
100
120
10
11
20 3
CENTER TO CENTER DISTANCE OF FIXTURES IN FEET
5
4
40 60 80 AREA PER FIXTURE IN SQUARE FEET 8 7 9 6
100
120 11
10
CENTER TO CENTER DISTANCE OF FIXTURES IN FEET
This quick Calculator chart determines the number and spacing of 1 lt.-32W PL-T units with Comfort Clear™ reflector for any level of illumination. Conversion factor: 1 lt. 26W PL-T with Comfort Clear Clear™ reflector multiply, F.C. x 0.8.
This quick Calculator chart determines the number and spacing of 1 lt.-42W PL-T units with Comfort Clear™ reflector for any level of illumination.
Spacing Ratio = 1.1
LRL NO. 499-9E Spacing Ratio = .98022/7142
REPORT PREPARED FOR: LIGHTOLIER LRL 499-9F2 8022/7132 (32W) S. NG LIGHTOLIER 5/2/99 REPORT BY: LIGHTING RESEARCH LABORATORY, INC. DESCRIP: 7.5” DIA. RECESSED DOWNLIGHT WITH COMFORT CLEAR™ REFLECTOR LAMPS: 1PL-T 32W LUMENS=2400 CANDLEPOWER SUMMARY
REPORT PREPARED FOR: LIGHTOLIER REPORT NO: LRL 499-9E REPORT BY: LIGHTING RESEARCH LABORATORY, INC. DESCRIP: 7.5” DIA. x 11 HT RECESSED DOWNLIGHT WITH COMFORT CLEAR™ REFLECTOR. LAMPS: 1PLT 42W LUMENS=3200 CANDLEPOWER SUMMARY 85ϒ ANGLE AVERAGE CP LUMENS 200 180 0 0 0 75ϒ 175 165 0 0 400 155 0 0 145 0 0 65ϒ 600 135 0 0 125 0 0 115 0 0 800 0 0 55ϒ 105 95 0 0 85 2 2 1000 75 4 4 65 5 5 45ϒ 1200 55 16 14 45 334 258 35 797 501 1400 25 1178 545 15 1504 426 5 1585 151 1600 15ϒ 25ϒ 35ϒ 0ϒ 5ϒ 0 1518 **Efficiency = 59.6%** ZONAL LUMENS AND PERCENTAGES
REPORT LRL NO. 499-9F2NO:
85ϒ
200
ANGLE AVERAGE CP LUMENS 180 0 175 0 0 165 0 0 155 0 0 145 0 0 65ϒ 135 0 0 125 0 0 115 0 0 0 0 55ϒ 105 95 0 0 85 1 1 75 2 2 65 3 3 45ϒ 55 11 10 45 226 175 35 678 426 25 933 432 15 1117 317 5 1179 113 35ϒ 0 1126 ZONAL LUMENS AND PERCENTAGES 75ϒ
400 600 800 1000 1200 0ϒ
5ϒ
15 ϒ
25ϒ
**Efficiency = 61.6%**
ZONE LUMENS
0-30 0-40 0-60 0-90 40-90 60-90 90-120 90-150 90-180 0-180
861 1287 1472 1478 191 6 0 0 0 1478
% LAMP %LUMINAIRE
35.9 53.6 61.3 61.6 8.0 0.3 0.0 0.0 0.0 61.6
ROOM CAVITY RATIO
80
1 2 3 4 5 6 7 8 9 10
50 .69 .65 .61 .58 .55 .52 .49 .46 .43 .38
30 .67 .63 .59 .55 .51 .48 .45 .42 .40 .35
0-30 0-40 0-60 0-90 40-90 60-90 90-120 90-150 90-180 0-180
50 .61 .58 .56 .54 .51 .49 .46 .44 .41 .37
30 .60 .57 .55 .52 .49 .47 .44 .41 .39 .34
0 10 .59 .56 .54 .50 .48 .45 .42 .40 .37 .32
0 .58 .56 .53 .50 .47 .44 .42 .39 .36 .31
20% FLOOR CAVITY REFLECTANCE For 1 Lt. 26W triple tube with Comfort Clear reflector multiply C.U.’s by 1.1
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2009 Philips Group • A0409
CC WALL RCR 1 2 3 4 5 6 7 8 9 10
80
70
1123 1623 1896 1908 284 12 0 0 0 1908
% LAMP %LUMINAIRE
35.1 58.9 50.7 85.1 59.3 99.4 59.6 100.0 8.9 14.9 0.4 0.6 0.0 0.0 0.0 0.0 0.0 0.0 59.6 100.00 ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
April 27, 1999
Coefficients of Utilization 10
S. NG LIGHTOLIER 5/2/99
ZONE LUMENS
58.3 87.1 99.6 100.0 12.9 0.4 0.0 0.0 0.0 100.00
Coefficients Of Utilization EFFECTIVE CEILING CAVITY REFLECTANCE 70 50 30 WALL REFLECTANCE 10 50 30 10 50 30 10 50 30 10 .66 .67 .66 .65 .65 .64 .63 .63 .62 .61 .61 .64 .62 .60 .62 .60 .50 .60 .59 .58 .57 .61 .58 .56 .59 .57 .55 .58 .56 .55 .53 .57 .54 .52 .56 .54 .52 .55 .53 .51 .49 .54 .51 .49 .53 .50 .49 .52 .50 .48 .40 .51 .48 .40 .50 .48 .40 .50 .47 .45 .43 .46 .45 .43 .48 .45 .43 .47 .44 .43 .40 .40 .42 .40 .45 .42 .40 .44 .42 .40 .37 .43 .39 .37 .42 .39 .37 .42 .39 .37 .32 .38 .35 .32 .38 .35 .32 .37 .34 .32
(42W)
50
30
10
50 30
10
50
30
10
50 30 10 50 30 10 50 30 10
.66 .62 .58 .55 .51 .48 .45 .42 .39 .37
.64 .58 .53 .49 .46 .42 .39 .36 .33 .31
.65 .61 .57 .54 .51 .48 .45 .42 .39 .36
.64 .59 .55 .51 .48 .45 .41 .38 .35 .33
.63 .57 .53 .49 .45 .50 .39 .36 .33 .31
.63 .59 .56 .53 .50 .47 .44 .41 .38 .36
.65 .60 .55 .52 .48 .45 .42 .39 .36 .33
Job Information
.62 .58 .54 .50 .47 .44 .41 .38 .35 .33
.61 .56 .52 .48 .45 .42 .39 .36 .33 .31
Type:
.60 .57 .54 .52 .49 .46 .43 .40 .38 .35
.60 .56 .53 .50 .46 .44 .41 .38 .35 .32
.59 .55 .51 .48 .45 .42 .39 .36 .33 .30
.58 .56 .53 .51 .48 .45 .43 .40 .37 .35
.58 .55 .52 .49 .46 .43 .40 .37 .35 .32
.57 .54 .50 .47 .44 .41 .38 .36 .33 .30
0 .56 .53 .50 .46 .43 .41 .38 .35 .32 .30