Preview only show first 10 pages with watermark. For full document please download

Calculite® Cfl Open Downlight 8022

   EMBED


Share

Transcript

Calculite® CFL Open Downlight  Page 1 of 2 8022 7 3/8" Aperture Triple Tube Vertical Lamp 14 7/8" (378mm) 26/32W=10 3/8" (264mm) 9 3/8" (238mm) 42W=11 1/8" (283mm) 11 3/4" (298mm) 3" (264mm) 7 3/8" Frame Dia. (181mm) 1 1/8" (29mm) MAX CEILING THICKNESS 8 5/8" Frame Dia. (209mm) OVERLAP Reflector Trim Frame-In Kit 8022 CCLW 8022 CCLP 8022 CCL 8022 S7126BU 7" aperture, 1 lamp 26W Triple Tube CFL (120/277V) 4-Pin (Amalgam) S7132BU 7" aperture, 1 lamp 26/32W Triple Tube CFL (120/277V) 4-Pin (Amalgam) S7142BU 7" aperture, 1 lamp 26/32/42W Triple Tube CFL (120/277V) 4-Pin (Amalgam) Comfort Clear™, White Flange Comfort Clear™, Polished Flange Comfort Clear™, Molded Trim Ring Add suffix. See options for other finishes. Dimming Options: S7132B or S7142B CU3 Lightolier PowerSpec 3% Dimming (120/277V) J1LD3 Lutron 5% Dimming (120V) J2LD3 Lutron 5% Dimming (277V) JUM7 Mark 7 Dimming (120/277V) J1MX Mark 10 Dimming (120V) J2MX Mark 10 Dimming (277V) Other dimming product available, please consult factory Remodeler Frame-In Kits 7126BURM 7" aperture, 1 lamp 26W Triple Tube CFL (120/277V) 4-Pin (Amalgam)) 7132BURM 7" aperture, 1 lamp 26/32W Triple Tube CFL (120/277V) 4-Pin (Amalgam) 7142BURM 7" aperture, 1 lamp 26/32/42W Triple Tube CFL (120/277V) 4-Pin (Amalgam) Features 1. Reflector: 16 ga. Alzak® aluminum, 50° visual cutoff to lamp and lamp image, medium distribution. Comfort Clear™ low iridescence finish. Self-flanged or flangeless with molded white trim ring (field paintable). 2. Socket Cup: Effectively dissipates heat and positions lamp holder. Snaps onto reflector neck to assure consistently correct optical alignment without tools. 3. Mounting Frame: Galvanized steel for dry or plaster ceilings. Accepts other 6” Triple Tube reflectors (see S6132BU Spec Sheet). 4. Retaining Springs: Precision-tooled steel friction springs secure reflector to mounting frame for quick, tool-less installation. 5. Mounting Brackets: 16 ga. steel. Adjust from inside of fixture. Use 3/4” or 1 1/2” lathing channel, 1/2” EMT, or optional mounting bars. 6. Ballast/J-Box: Electronic 120V-277V. UL listed for through branch circuit wiring with max of (8) No. 12 AWG, 90°c supply conductors. Outboard mounted to reduce heat transfer and maintain lamp efficacy and life. Service from below without tools. Electrical Note: Note: For ballast electrical data and latest lamp/ballast compatibility refer to “Ballast” specification sheet for complete electrical data. Options and Accessories (continued) Emergency Ltg. Kit FA EM3E* FA EM4* Fuse (Slow Blow) Add suffix F Existing/Thk. Ceiling Plaster Trim Ring CA7FL Emergency Add suffix EM* Chicago Plenum Use 7142, BULC *See Spec. Sheets: FAEM, FAEC Mounting Bars & Accessories; see Specification Sheet MBA. Sloped Ceiling Adapters; see Specification Sheet SCA. Labels UL, CUL, I.B.E.W Alzak® is a registered trademark of ALCOA Job Information Job Name: UL Listed for through branch circuit wiring with max of (8) No 12 AWG, 90 degree C supply conductors. Cat. No.: Options and Accessories Lamp(s): Comfort Clear™ Finishes1 Diffuse CCD Champagne Bronze CCZ Pewter CPW Top View Other Finishes White WH Specular Clear CL Specify desired flange. W White, P Polished, Blank - Molded Ring 1 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2009 Philips Group • A0409 Notes: Type: Calculite® CFL Open Downlight  Page 2 of 2 32W Quick Calculator ROOM SURFACE REFLECTANCES: 80 70 50 40 30 20 RCR = 1 (Rm. width = 10 x Mtg. Ht. above work plane) RCR = 5 (Rm. width = 2 x Mtg. Ht. above work plane) RCR = 10 (Rm. width = Mtg. Ht. above work plane) 60 INITIAL FOOTCANDLES RCR = 1 (Rm. width = 10 x Mtg. Ht. above work plane) RCR = 5 (Rm. width = 2 x Mtg. Ht. above work plane) RCR = 10 (Rm. width = Mtg. Ht. above work plane) 60 ROOM SURFACE REFLECTANCES: 80% Ceiling; 50% Wall; 20% Floor 3200 Lumens Per Lamp 80 80% Ceiling; 50% Wall; 20% Floor 2400 Lumens Per Lamp 70 INITIAL FOOTCANDLES 7 3/8" Aperture Triple Tube Vertical Lamp 42W Quick Calculator 8022 50 40 30 20 10 10 20 3 40 60 80 AREA PER FIXTURE IN SQUARE FEET 7 9 6 8 5 4 100 120 10 11 20 3 CENTER TO CENTER DISTANCE OF FIXTURES IN FEET 5 4 40 60 80 AREA PER FIXTURE IN SQUARE FEET 8 7 9 6 100 120 11 10 CENTER TO CENTER DISTANCE OF FIXTURES IN FEET This quick Calculator chart determines the number and spacing of 1 lt.-32W PL-T units with Comfort Clear™ reflector for any level of illumination. Conversion factor: 1 lt. 26W PL-T with Comfort Clear Clear™ reflector multiply, F.C. x 0.8. This quick Calculator chart determines the number and spacing of 1 lt.-42W PL-T units with Comfort Clear™ reflector for any level of illumination. Spacing Ratio = 1.1 LRL NO. 499-9E Spacing Ratio = .98022/7142 REPORT PREPARED FOR: LIGHTOLIER LRL 499-9F2 8022/7132 (32W) S. NG LIGHTOLIER 5/2/99 REPORT BY: LIGHTING RESEARCH LABORATORY, INC. DESCRIP: 7.5” DIA. RECESSED DOWNLIGHT WITH COMFORT CLEAR™ REFLECTOR LAMPS: 1PL-T 32W LUMENS=2400 CANDLEPOWER SUMMARY REPORT PREPARED FOR: LIGHTOLIER REPORT NO: LRL 499-9E REPORT BY: LIGHTING RESEARCH LABORATORY, INC. DESCRIP: 7.5” DIA. x 11 HT RECESSED DOWNLIGHT WITH COMFORT CLEAR™ REFLECTOR. LAMPS: 1PLT 42W LUMENS=3200 CANDLEPOWER SUMMARY 85ϒ ANGLE AVERAGE CP LUMENS 200 180 0 0 0 75ϒ 175 165 0 0 400 155 0 0 145 0 0 65ϒ 600 135 0 0 125 0 0 115 0 0 800 0 0 55ϒ 105 95 0 0 85 2 2 1000 75 4 4 65 5 5 45ϒ 1200 55 16 14 45 334 258 35 797 501 1400 25 1178 545 15 1504 426 5 1585 151 1600 15ϒ 25ϒ 35ϒ 0ϒ 5ϒ 0 1518 **Efficiency = 59.6%** ZONAL LUMENS AND PERCENTAGES REPORT LRL NO. 499-9F2NO: 85ϒ 200 ANGLE AVERAGE CP LUMENS 180 0 175 0 0 165 0 0 155 0 0 145 0 0 65ϒ 135 0 0 125 0 0 115 0 0 0 0 55ϒ 105 95 0 0 85 1 1 75 2 2 65 3 3 45ϒ 55 11 10 45 226 175 35 678 426 25 933 432 15 1117 317 5 1179 113 35ϒ 0 1126 ZONAL LUMENS AND PERCENTAGES 75ϒ 400 600 800 1000 1200 0ϒ 5ϒ 15 ϒ 25ϒ **Efficiency = 61.6%** ZONE LUMENS 0-30 0-40 0-60 0-90 40-90 60-90 90-120 90-150 90-180 0-180 861 1287 1472 1478 191 6 0 0 0 1478 % LAMP %LUMINAIRE 35.9 53.6 61.3 61.6 8.0 0.3 0.0 0.0 0.0 61.6 ROOM CAVITY RATIO 80 1 2 3 4 5 6 7 8 9 10 50 .69 .65 .61 .58 .55 .52 .49 .46 .43 .38 30 .67 .63 .59 .55 .51 .48 .45 .42 .40 .35 0-30 0-40 0-60 0-90 40-90 60-90 90-120 90-150 90-180 0-180 50 .61 .58 .56 .54 .51 .49 .46 .44 .41 .37 30 .60 .57 .55 .52 .49 .47 .44 .41 .39 .34 0 10 .59 .56 .54 .50 .48 .45 .42 .40 .37 .32 0 .58 .56 .53 .50 .47 .44 .42 .39 .36 .31 20% FLOOR CAVITY REFLECTANCE For 1 Lt. 26W triple tube with Comfort Clear reflector multiply C.U.’s by 1.1 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. www.lightolier.com © 2009 Philips Group • A0409 CC WALL RCR 1 2 3 4 5 6 7 8 9 10 80 70 1123 1623 1896 1908 284 12 0 0 0 1908 % LAMP %LUMINAIRE 35.1 58.9 50.7 85.1 59.3 99.4 59.6 100.0 8.9 14.9 0.4 0.6 0.0 0.0 0.0 0.0 0.0 0.0 59.6 100.00 ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE = .20 April 27, 1999 Coefficients of Utilization 10 S. NG LIGHTOLIER 5/2/99 ZONE LUMENS 58.3 87.1 99.6 100.0 12.9 0.4 0.0 0.0 0.0 100.00 Coefficients Of Utilization EFFECTIVE CEILING CAVITY REFLECTANCE 70 50 30 WALL REFLECTANCE 10 50 30 10 50 30 10 50 30 10 .66 .67 .66 .65 .65 .64 .63 .63 .62 .61 .61 .64 .62 .60 .62 .60 .50 .60 .59 .58 .57 .61 .58 .56 .59 .57 .55 .58 .56 .55 .53 .57 .54 .52 .56 .54 .52 .55 .53 .51 .49 .54 .51 .49 .53 .50 .49 .52 .50 .48 .40 .51 .48 .40 .50 .48 .40 .50 .47 .45 .43 .46 .45 .43 .48 .45 .43 .47 .44 .43 .40 .40 .42 .40 .45 .42 .40 .44 .42 .40 .37 .43 .39 .37 .42 .39 .37 .42 .39 .37 .32 .38 .35 .32 .38 .35 .32 .37 .34 .32 (42W) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 .66 .62 .58 .55 .51 .48 .45 .42 .39 .37 .64 .58 .53 .49 .46 .42 .39 .36 .33 .31 .65 .61 .57 .54 .51 .48 .45 .42 .39 .36 .64 .59 .55 .51 .48 .45 .41 .38 .35 .33 .63 .57 .53 .49 .45 .50 .39 .36 .33 .31 .63 .59 .56 .53 .50 .47 .44 .41 .38 .36 .65 .60 .55 .52 .48 .45 .42 .39 .36 .33 Job Information .62 .58 .54 .50 .47 .44 .41 .38 .35 .33 .61 .56 .52 .48 .45 .42 .39 .36 .33 .31 Type: .60 .57 .54 .52 .49 .46 .43 .40 .38 .35 .60 .56 .53 .50 .46 .44 .41 .38 .35 .32 .59 .55 .51 .48 .45 .42 .39 .36 .33 .30 .58 .56 .53 .51 .48 .45 .43 .40 .37 .35 .58 .55 .52 .49 .46 .43 .40 .37 .35 .32 .57 .54 .50 .47 .44 .41 .38 .36 .33 .30 0 .56 .53 .50 .46 .43 .41 .38 .35 .32 .30