Preview only show first 10 pages with watermark. For full document please download

Camera Lens Canon 350d (digital / Reflex) Sigma 18

   EMBED


Share

Transcript

Presented by: camera lens Canon 350D (digital / reflex) Sigma 18-50mm F2.8 EX DC (calibrated) mobile advanced Applications Components Indoor measurements, like on workspace and desktop areas in offices. Lens SIGMA 18-50mm F2.8 EX DC (incl. lens hood & dust cover) Fast and easy determination for luminances in outdoor areas. For example the illumination of public squares and places in the urban surrounding. Mobility case Samsonite + carrying strap Transport case TechnoTeam Wide strap [ EW-100DBII ] Power supply Determine the illumination for façades and lighting installations for streets and other public traffic ways. Elektronics Sensor / Resolution CMOS Canon ASP-C mit 3456(H) x 2304(V) File format 12 Bit RAW - data with Bayer structure uncompressed PC-Interface USB 2.0 Luminance resolution 1728(H) x 1152(V) Dynamic resolution Single measurement: 1:4000 2 Battery pack [ NB-2LH1 ] Battery charger CB-2LTE + power plug AC adapter kit [ ACK 700 ] Compact mains adapter [ CA-PS700 ] + power cord / DC coupler [ DR-700 ] Cable / Interface Video cable [ VC-100 ] USB - Interface cable [ IFC-400 CPU ] High-Dyn measurement: 1:32000 (1/1250 sec. = ti = 8 sec.) Configuration Obtain the parameters for glare and daylight (luminance, vertical and cylindrical illuminances, UGR, DGI, daylight quotient D, uniformity). Aperture values F4 - F11 (calibrated) in 1/3 steps Focus (measuring distance) > appr. 280mm (automatic focus / manual focus) Focal length / Viewing angle Focal length 18mm: 65°(H) x 45°(V) Light sensitivity Focal length 50mm: 28°(H) x 19°(V) Aperture 4 (typical accuracy rating) Software 4 11 ISO 100 1600 100 ti= 0.001 s 15 kcd/m² 900 cd/m² 100 kcd/m² ti= 3.0 s 5 cd/m² 0.3 cd/m² 40 cd/m² 30 sec. - 1/4000 sec. (calibrated for luminance measurements) AEB +/- 2 EV in 1/3 steps (manual) Measurement Selection of measuring range Selecting aperture, exposure time and ISO - speed parameter V(λ)-Matching Numerical transformation from R, G, B - sensor data Calibration uncertainty ∆L in % ∆L = 2.5% Glare rating on outdoor luminaires (luminance, vertical illuminance, veiling luminance, uniformity). Uniformity ∆L in % Measuring uncertainty ∆L in % (for standard illuminant A) Evaluate the illumination of streets confirming guilty standards (luminance, vertical illuminance, lengthwise uniformity, TI-value). CompactFlash - Card 1GB Exposure time Repeatability ∆L in % Operating data 4 5,6 8 11 0.25 ms 3.1 3.5 3.7 4.3 2.5 ms 1.5 1.8 2.0 2.7 25 ms 1.3 1.7 1.9 2.5 0.25 s 1.3 1.7 1.9 2.5 2.5 s ∆L = 2% 1.3 1.7 1.9 2.5 Ti\Av 4 5,6 8 11 0.25 ms 7.6 8.0 8.2 8.8 2.5 ms 6.0 6.3 6.5 7.2 25 ms 5.8 6.2 6.4 7.0 0.25 s 5.8 6.2 6.4 7.0 2.5 s 5.8 6.2 6.4 7.0 CompactFlash - Card changeable storage device Operating system Windows 2000/XP Measuring software LMK2000 TechnoTeam Bildverarbeitung GmbH reserves the right to change products and specifications without prior notice. EOS Digital Solution (CD ROM) ArcSoft PhotoStudio (CD ROM) LMK2000 measuring software (CD ROM) Manual / Certificate Software manual (CD ROM) Manual Canon EOS 350D User manual LMK2000 software Calibration certificate Optional Ti\Av Memory Storage device Additional modul for LMK2000 software to measure colour values ND-filter set or single ND-filter USB CompactFlash - Card reader 2nd CompactFlash - Card storage device Remote control RC-5 Tripod Further lenses on request