. b The flash recycling starts.
I
2 Check that the flash is ready. The pilot lamp will first turn green (ready for quick flash), then red (flash ready). Pressing the pilot lamp will fire a test flash.
I I
Quick flash enables a flash to be fired before flash-ready, when the pilot lamp is still green. Although the Guide No. will be 116 to 112 that of the full output, quick flash is effective for near subjects and when you want a shorter recycle time. Set the drive mode to single shooting. Quick flash cannot be used in the continuous shooting, FEB, manual flash, and stroboscopic flash modes. Quick Rash can also be used during continuous Rash shooting (C.Ffl-06 -t p.27)
'Rwer OPf To save battery power, the power will tum off automatically after a certain period (approx. 1.5 min. to 15 min.) of idle use. To turn on the Speedlite again, press the camera's shutter button halfway. Or press the Speedlite's test firing button. Auto Power Off can also be disabled. (C.Fn-01 + p.27)
1
m-Full ,
tic Flash Shootingathe camera's shooting mode to (Program AE) or uto), E-TTL IIIE-TTL fully automatic flash will make it as
1l.C.
,
.....J
is displayed.
2 Focus the subject. Press the shutter button halfway to focus. b The shutter speed and aperture will be displayed in the viewfinder. Check that the ~ 5 icon 2 is lit in the viewfinder.
Take the picture. F- 5.6
-----
Check that the subject Is within the effective range displayed on the LCD panel. b Right before the shot is taken, a preflash is fired, then the main flash is fired. b If a standard flash exposure was obtained, the flash exposure confirmation lamp will light for about 3 sec.
will be displayed M the LCD panel even If he w m is k&~U&&th E-mL11. RW** wmsum @@llm mpaOkSLaa vm right m w ~rTPm sutajaut and Zakd the pWre -ah. Wth a diiW camera, you aan also Irmewe the oamers's IS0 speed.
'B-LB
E=llLII and E - T n Autoflash in the Shooting Modes
4
he background is dark like a night scene, a slow sync speed will be used to obtain a standard exposure of both the maln subject and background. Standard exposure of the main subject is obtained with the flash, while a standard exposure of the background is obtained with a slow shutter speed. will be used for low-light scenes, using a
If you use the cDEP> or shooting mode, the result will be the same as us~ngthe (Program AE) mode.
Flash Sync Speeds and Apertures Used Shutter Speed Setting
1 P I lb
1
Set automatically (1160 sec. - 1/X sec.) Set manually (30 sec. - 1IX sec.)
1
Set automaticallv 130 sec. - 1/Xsec.) 1 Set manually (bulb, 30 sec. - 1IX sec.) I 1/X sec. Is the camera's maximum flash sync speed.
I M I
Av
Automatic Automatic Manual Manual
I
I
Using Flash @ Flash Exposure Compensation ...................... 14 FEB ............................................................. 15 FEL: FE Lock ...................................................... 16 High-speed Sync ............................................. 17 Bounce Flash........................................................ 18 ZOOM: Setting the Flash Coverage and Using the Wide Panel ................................................... 20 M: Manual Flash ................................................. 22
MULTI: Stroboscopic Flash .................................. 24 CC, Second-Curtain Sync ...................................
26
C.Fn. Setting Custom Functions....................... 27 External Flash Metering........................................30 Speedlite Control with the Camera's Menu Screen ...............................................................
32
Flash Exposure Compensation
I
11
I
-
In the same way as normal exposure compensation, you can set exposure compensation for flash. The flash exposure compensation amount can be set up to *3 stops in 113-stop increments. (If the camera's exposure compensation is in 112-stop increments, flash exposure compensation will be in 112-stop increments.)
1 Select ern>. Press the button so that is displayed. b The icon and the flash exposure compensation amount will blink.
,
2 Set the flash exposure
compensation amount. Tum the <@> dial to set the amount, To cancel the flash exposure compensation, set the amount to
3 Press the s @ > button.
b Flash exposure compensationwill be
set.
Setting the flash exposure compensation can be limited to only the dial. (C.Fn-13 -t p.27)
-=a
k
while automatically changiw
up to f 3 etops in 113-stop increments enables only 1/2-stop increments). 'I*~&J&I'.:J [Flet&".w8ure Bracketinn).
I b The <%> icon and bracketing amount will blink.
2 Set the flash exposure bracketing amount. Turn the <@> dial to set the amount.
3 Press the <@> button. b FEB will be set.
th flash exposure compensation and FE .--LC1
.
You can prevent the FEB from being cancelled automatically affer the three shots are taken (C Fn-03 + p 27) The FEB shooting sequence can be changed (C Fn-04 -t p 27)
FEL: FE Lock FE (flash exposure) lock locks the correct flash exposure setting for an) part of the scene. With displayed on the LCD panel, you press the camera's button. If the camera does not have the button, press thc button.
1 Focus the subject. 2 Press the GEL> button. (616) a Aim the subject at the center of the viewfinder and press the button. The Speedlite will fire a preflash and the required flash output for the subject is retained in memory. b "FEL" will be displayed in the viewfinder for 0.5 sec. Each time you press the button, a preflash will be fired and a new flash exposure setting will be locked.
@
.
I? thesubJ@ is too far away and underexposure will result, the is not displayed on the LCD panel, FE lock cannot be set. If the subject is too small, FE lock might not be very effective.
a Highspeed Sync m With highpeed sync (FP flash), the flash can synchronize with all shutter speeds. This is convenient when you want to use aperture priority for fill-flash portraits.
Select < Ql>. Press the < ~ H button /D> so that < is displayed. I> icon is displayed.
WWset a shutter speed that is the same or slower than the cambra's maximum flash qnc epeed, will not be displayed in the viewfinder. With high-speed sync, the faster the shutter spsedpsed the shorter the effective flash range w~llbecome. Check the LCD panel far the effective turn to normal flash, press Um button main. The bosmpleflssh.Cannot be set.
17
Bounce Flash
1
By pointing the flash head toward a wall or ceiling, the flash will bounce off the surface before illuminating the subject. This can soften shadows behind the subject for a more natural-looking shot. This is called bounce flash.
Set the Bounce Direction Hold down the button and turn the flash head. If the flash coverage is set automatically, the flash coverage will be fixed to 50mm. The LCD panel will also display < > mm. a You can also set the flash coverage manually.
--
ba
-r
r
,py.
' -
sz$q+--r-
-
-
Ifthe wall or wiling is too far a = o u ~ ~ a b h m i i h 66%%%k and regult in underrucposure. a The wail or miling should be a plain, white color for high reflectance. If fhe bounmsurfEKseis not whRe, a color cast may result in the picture. a AReF Vou take fieshot, if the flash exposure mtnimation lamp does not
a catchlight in the subject's
I
2 Pull out the wide panel. b The catchlight panel will come out at the same time.
3 Push the wide panel back in. Push in only the wide panel. Follow the same procedure as for bounce flash.
-
-
about 0.5 2 m (1.6 6.6 ft) away, hold the button and tilt the flash head downward by 7" to mate the lower part of the image.
I
h
ZOOM:Setting the Flash Coverage and Using the Wide Panel
4
The flash coverage can be set to match the lens focal length from 24mm to 105mm. The flash coverage can be set automatically or manually. Also, with the built-in wide panel, the flash coverage can be expanded for 14mm wide-angle lenses.
Press the button. Turn the <@> dial to change the flash coverage. If is not displayed, the flash coverage will be set automatically.
set the flash werage manually, make sure it covers the lens
& so that the picture will not have a dark periphery.
1
u use a commerclally-awllablesync cord to connect the camera to *
.
Wdrr Panel
I
Pull out the wide panel and place it over the flash head as shown. The flash coverage will then be extended for 14mm. The catchlight panel will come out at the same time. Push the catchlight panel back in. The button will not work. h coverage will not be compatible .with the EFlBmm f12.8 FisReye
bmm-
with the wide panel in place, the entire display on
i8kw a warning. Since the subject will be
th& Q~unca flCh end direct flash, it will look Pull dur i ~w& %% panel gentlgr. .6 . Usim excessive force may detach the wide pane
1
I
mrneras have one of three image sizes. The lens'
I length will differ depending on the camera's image size. t
automaticallv recoanizes the EOS DIGITAL camela's @&wand automaticaiy sets the flash coverage for lens focal @&m 24mm to 105mm. b 8%-Speedlite is attached to a compatible camera, <=>will @#an the Speedlite's LCD panel.
Auto zoom can be disabled (C Fn-09 + p 27)
rI ,
M: Manual Flash
mu can set the flash output from 11128 power to 111 full power in 113stop increments. Use a hand-held flash meter to determine the required flash output to obtain a correct flash exposure.
1 Press the button so that *M> is displayed.
Ua7+3.52 3 4 6 9 D l m
2 Set the flash output. "
Press the <@> button. b The flash output blinks. Turn the dial to set the flash output, then press the <@> button. I
J
Press the shutter button halfway to see the effective flash range displayed. U W I ~ . S Z1 7 8 9 n u m
p,
... h 0ubwt Display
When you change the flash output during shooting, the table below makes it easier to see how the stop changes such as 112 -0.3 + 112 112 +0.3. You can see how the stop changes when you increase or decrease the flash output. For example, when you decrease the flash output to 112, 112 -0.3, or 11 -0.7, and then increase the flash output to more than 112, 112 +0.3, 11 +0.7, and 111 will be displayed. (Example)
Figures for decreased flash output +
... I
...
t Figures for increased flash output
I
-1D series camera, you can
kvsl manually for closeup subjects. 5 camera's shooting mode to or CAW. m % e Soeedllte to manual flash.
up an 18% gray card. lace the gray card at the subject's position.
n the viewfinder, the entire spot metering circle at the center should cover the gray card.
ress the button. (616)
b The Speedlite will fire a preflash and the required flash output for the subject is retained in memory. b On the right side of the viewfinder, the exposure level indicator will show the flash exposure level for the correct flash exposure.
Set the flash exposure level. Adjust the Speedlite's manual flash level and the camera aperture so that the flash exposure level aligns with the standard exposure index.
Take the picture. Remove the gray card and take the picture.
a
I
This @turn ~ d r l (only s wlth EX-series Speedllteswith manual flash coupled an EOS-1D s e w camera.
23
I: Stroboscopic Flash W M stroboscopic flash, a rapid series of flashes is fired. It can be use
to capture multiple images of a moving subject in a single photograph. You can set the firing frequency (number of flashes per sec. expressed as Hz), the number of flashes, and the flash output.
1 Press the button so that is displayed.
2 Select the item to be set. Press the <@> button to select the item (blinks).
3 Set the desired number. a Tum the <@> dial to set the number, then press the <@> button. b The next item to be set will blink. a After you set the flash output and press the <@> button, all the settings will be displayed.
e l c T a t i n g thatshutter Speed During stroboscopic flash, the shutter remains open until the firing stops. Use the formula below to calculate the shutter speed and set it with the camera. Number of flashes + Firing frequency = Shutter speed For example, if the number of flashes is 10 and the firing frequency is 5 Hz, the shutter speed should be at least 2 sec.
remote switoh, and exbtmlpower source is recon)mmded. uf of 111 or 112 csannot h&seX for elloboscopic flash. G Rash can b$ u ~ c l v d t h*but&," shes is dtspkryed ea- -, the fhiq wfll mlinua until the shutter dosea M $d, The nurnberoffl~wiUbeli~asshown by thelable below.
baximum Stroboscopic Flashes
m.Second-Curtain Sync Wth.a slow shutter speed, you can create a light trail following the cs&ject. The flash fires right before the shutter closes.
Press the button so thc el$+> is displayed.
staik~*1E Tn the Oamera'a"DtWmode, ash,press the S%@EiWsbcmdn again.
.
es will be @#f +n at $lo+ shutter e preflasE,'add nof s maYfunc8on. 8
26
!
-
I
Custom Functions
-
lite features to suit your shooting preferences.
stom Functions.
m lndloator display
I
1 Hold until
2 Select the Custom Function No. Turn the c@> Function No.
dial to set the Custo
Change the setting. Press the <@> button. b The Custom Function No. blinks. b Tum the <@> dial to set the desirt number, then press the <@>butto b After you set the Custom Function and press the button, tt camera will be ready to shoot.
-3
C.Fn-02-3: Convenientqhen you want to check the depth of field. (p.44) G,Fn-12: If an externahpower source is used, the flash recycling is powered q u r r e n t l y by the internal batteries and external In this case, when the internal batteries became,ex austed first, shooting might not be possible. If 1 is set,tlX&flash recycling will be powered only by the external power source. The internal batteries will thereby last longer. Note that even if you set it to 1, the Speedlite will internal batteries for flash control.
3
.
5-1 isgeared for EOS-series film cameras. set it if you have a, EOS DIGITAL camera or the EOS REB 300X. If C.Fn-05-1 is set for such cameras, the flash control will no. 'properly. The Rash might not fire or it might fire only at full output With Type-A cameras, if C.Fn-05-1 is set, wireless autoflash shooting wi
.,.
If 'AF-assist beam OFF" is set with the Speedl~teor camera, the AF-
I
F
I
I Fbsh Metering
@@$ash reflected off the subject is metered by an external metering s a w r in teal time. When the standard flash exposure is attained, the f l ~ output h is cutoff automatically. Auto external metering compatible the EOS-1D Mark Ill and manual external metering compatible w i t ail EOS cameras are provided.
I
Set auto external metering. Set the Speedlite Custom Function to C.Fn-052. (p.27)
IF -.-. , , &-w~~>q&&,,@. metdng, the camera's
speed
J External Metering
1 Set manual external metering. a Set the Speedlite Custom Function to C.Fn-053. (p 27)
Set the Speedlite to the camera's Press the <@> button so the IS0 speed blinks. Turn the <@>dial to set the IS0 speed, then press the <@> button.
Set the Speedlite to the camera's Press the c@> button so the aperture setting bllnks. Turn the <@> dial to set the aperture, then press the <@>button.
nnot connect a Speedllta to anetherSpeedlite's PC terminal with c cord. The second SpesdlitewilInot fire.
I
lite Control with the Camera's Menu Screen If the Speedlite is attached to an EOS camera which has a Speedlite control function, it can control the Speedlite as shown below. For the menu operation procedure, refer to your camera's instruction manual
a Setting Speedlite functions The settable functions will vary depending on the flash mode. Flash mode Shutter sync (Istl2nd curtain) . FEB Flash exposure compensation Flash metering mode Flash firing Clear Speedlite settings
a Speedlite Custom Functions C.Fn-00 - 13; TotaCl4
a Clear All Speedlite Custom Functions Only C.Fn-00 will not be cleared. Flash function settings screen'
Flash C.Fn settings screen'
0: Enabled
I :Disabled
'Screens from the EOS-ID Mark Ill
' ,
...-.,-_,
lready been set with the Speedlite, be set with the camera. To set it with ash exposure compensationto zero.
If any Speadllte Custom Functions and flash function settings other than Rash exposure compensation have been set by both the camera and Speedlite, the latest setting will take effect.
Wireless Flash About Wireless Flash......................................... Wireless Settings ................................................ Fully Automatic Wireless Flash ........................ .... Flash Ratio with E-TTL 11 ...................................... Setting the Flash Output for Each Slave .............. Setting Manual Flash and Stroboscopic Flash with the Slave ....................................................
34 36 37 41 45 46
1:
A b b t Wireless Flash With multiple Canon Speedlites having the wireless flash feature, you m n create various lighting effects with the same ease as using normi E-TTL II autoflash. The settings you input with the 580EX II (master unit) attached to the camera are also automatically transmitted to the slave units which an controlled by the master unit via wireless. Therefore, you need not operate the slave unit@)at all during the shoot. The basic wireless set-up is illustrated below. All you need to do is se b master unit to enable wireless E-TTL II autoflash (p.37 Note that with Type-A cameras prior to the EOS-1D Mark II and EOS ELAN 7NElELAN 7N/30V/33V, E-TTL autoflash will be used instead.
w
i
n
g and Operation Range
Fflash with three slave group
(p.43)
Wireless Settings You can switch between normal flash and wireless flash. For normal shooting, be sure to set the wireless setting to OFF.
Master Unit SeMng
--
I Press the button for sec. or longer until the display blinks as shown on the left.
2 Set it as the master unit. Turn the <@> dial until button. b <->and will be displayed, and the Speedlite is set the master unit. ETTL
szmn ?L(m
Slave Unit Setting Set it as a slave unit. Do the "Master Unit Setting" procedure above. For step 2, turn t <@> dial until <> blinks then press the <@> button. b <->and <=>will be displayed, and the Speedlite is set a slave unit.
Set the other 580EX II
Check the communication If the master unit and slave unit(s) are set to a different channel, set them all to the same channel (p.40).
Position the camera and Position theSpeedlites within the range shown on the next page.
Set the master unit's flash mode For shooting, will also be set automatically for the slave unit(s).
Check that the flash Is ready. the AF-assist beam will blink at 1-sec.
7 Check the flash operation.
II
a Press the master unit's test firing button. b The slave unit will fire. If the flash does not fire, adjust the slave unit's angle toward the master unit and distance from the master unit.
8 Set the camera and shoot.
1
a Set the camera in the same way as with normal flash shooting.
a Use the mini stand (tripod socket provided) to prop up the slave un/ a Use the bounce feature to swing the slave unit so that its wireless sensor faces the master unit. a Indoors, the wireless signal can also bounce off the wall so there is more leeway in positioning the slave unlt(s). After positioning the slave unit(s), be sure to test the wireless flash operation before shooting. Do not place any obstacles between the master unit and slave unit(s). Obstacles can block the transmission of wireless signals.
the slave unn's auto power off can be mnceled by
n be changed. (C.Fn-I1 -t p 27)
firing so that only the slave unit@)
Disable the master unit's flash Turn the <@3> dial to select cO FF >, then press the <@> button. b The icon will change to
Flash exposure compensation and other settings set with the maste unit will also be automatically set in the slave units. Thus, you operate the slave unit@).Wireless flash with the following sett be done in the same way as with normal flash shooting.
[
,
I
I
Flash exposure compensation
- High-speed sync (FP flash)
. FEB Manual flash
- Stroboscopic flash
.FE lock
I
If there is another Canon wireless flash system nearby, you can chang the channel No. to prevent signal confusion. Both the master and slav units must be set to the same channel No.
1 Press the so that
button'
blinks.
2 Set the channel No. Turn the <@> dial to select the channel number, then press the > button.
as two slave units and the master unit disabled
ned to different slave groups by setting the
1 Set the wireless mode to . (p.36) Press the so that blinks.
button
3 Set the slave ID.
P
Press the <@> button. F Slave ID < A >will be set. For the other slave unit, do steps ' and 2, turn the <@> dial to seled , then press the <@> button Slave ID will be set.
p t t i n g the nifasw~mlz ma@hooB*
1 Set the wireless mode to <->.
-
3
(p.36)
Disable the master unit's flash firing. (p.39) Press the butt01 so that blinks. Select the flash ratio. Turn the <@> dial to select button.
5 Set the flash ratio. a Turn the <@> dial to set the flash ratio.
6 Set the camera and shoot. Set the camera in the same way e with normal flash shooting.
a 42
W fb EUB EMF4 &ELAN IIE/6W@E, EOS REBEL 01500N, EOS UI, EOS IX UtellX7, EOS REBEL 20001300, and REBEL XS NI REBEL 5 Iff EOS 300DNE66,the flmh MUD cannot bSePwlth multipleSpeedlites.
I For slave , also set the flash exposure compensation as necessary.
43
2 Set the master unit and shoot Follow "Setting the Master Unit ar Shooting" on page 42. In step 4, select .
&i Bz Is sat,ftie siak u& ln s ~ a { & ~ ~ ; pw' iel l d d point the slave unit Inelave group toward the subject, the w i l ' ~ a v @ @ % $ -,
:;:,-I,,<:
st.
i t , ,
-. >,gd
g Flash If the camera has a depth-of-field preview button, pressing it will fire flash continuously for 1 sec. This is called the modeling flash. It enables you to.see the shadow effects on the subject and the ligh balance. You can fire We modeling flash for both wireless and norm flash shooting.
@~&m&eUngflacsh m m h n IQ c'bhqcu~~e tlmes. If ya J flre the modeling flash 10 consecutive times, allow the Spwdllte to rest forat least 10 min. to a~nidr),vfqhm.tlngand det4oPating the fia head. -
'!
&madell~Q fl& cannot be fired d h the EOS REBEL 20001300 and m e - B cameras (p.2).
m u t Slave Gyup Control Slave group A
For example, if you have the slave ID to for three slave units, all threc slave units will be controlled as if the were one Speedlite in slave group A.
E m l t h e Flash O u t m t a r Each Slave ith rnarlcral flash an
litcas, you can set a different flash
Press the button so that is displayed.
Press the button so that <-> blinks.
Select the flash ratio. Turn the < @ :.dial to select A: B> or , then press the <@> button.
Set the flash output. Press the <@> button. b The slave ID < A > will blink. Turn the <@> dial to set the flash output for ,then press the <@> button. The slave ID will blink. Turn the <@>dial to set the flash output for ,then press the <@> button. The slave ID will blink. Turn the <@> dial to set the flash output for , then press the <@> button. b All the slave IDSwill light.
Setting Manual Flash and Stroboscopic Flash with the Slave Manual flash or stroboscopic flash can be set manually with the slave unit. As with studio flash units, you can set the flash output individual with the slave units for wireless or manual flash.
b n u a l Flash Hold down the button f o ~ sec, or more. b will blink. Set the manual flash output (p.22).
Hold down the button Fc 2 sec. or more. b will blink. Press the button again and will blink. Set the stroboscopic flash (p.24).
580EX II System
(D Speedlite 580EX II @n-cameraIMaster unit) @ Speedlite Transmitter ST-E2
cD
@ 0
@
Dedicated transmitter for wireless control of 580EX 111430EX set as slave units. Compact Battery Pack CP-E4 Compact, lightweight, and portable extemal power pack. Provide the same level of dust- and water-resistance as the 580EX II. It u: eight size-AA alkaline or Ni-MH batteries. It can also use size-AA lithium batteries. EX-series Speedlite with slave function Off-Camera Shoe Cord OC-E3 Enables the 580EX II to be connected to the camera up to 60 cmlZ away. Provides the same level of dust- and water-resistance as tht 580EX II. All of the EOS camera's automatic functions can be use( Speedlite Bracket SB-E2
For the external power pa& use @ above. If a nonCanon, external m e r p a o k Is used, tt may cause malfunction.
&%;era's
white balance is set to
<'m> or
Wth your camera, see "White Balance"
=% pmf camera's instruction manual. About
# a@matfcally to make it easier to autofocus. The AFwarIfg'w1th all EOS cameras. The AF-assist beam is @I &mm and longer lenses. The effectwe range is shown
Troubleshooting Guide
-
If there is a problem, refer to this Troubleshooting Guide.
*am. *The batteries are installed in the wrong orientation. b Install the batteries in the correct orientation. (p.8) The Speedlite's internal batteries are exhausted. b If the flash recycling time takes 30 sec. or longer, replace the batteries. (p.8) b Install the Speedlite's internal batteries even when you use ar external power source. (p.8) The Speedlite is not attached securely t o the camera. b Attach the Speedlite's mounting foot securely to the camera. I The electrical contacts of the Speedlite and camera are d b Clean the contacts. (p.9) T
un&does not fire. The slave's wireless mode is not set to <->. b Set it to <->. (p.36) The slave unit(s) is not positioned properly. b Place the slave unit within the master unit's transmission rang (p.38) b Point the slave unit(s)'s sensor toward the master unit. (p.38)
whe power turns off by Itself. After 90 sec. of idle operation, auto power off took effect. b Press the shutter button halfway or press the test firing buttor (P.10)
The entins LCD panel blinks. The wide panel has been pulled out for bounce flash. b Retract the wide panel. (p.20)
le camera. the camera. (p.9)
&:&wentllted down by 7'. Ition. (p.19)
d@@
---A
setting was a higher I dark periphery. rage that is a lower number than the lens focal
b r n o f the plcture looks dark, you were too Wblect 1 3 s closer than 2 d 6 . 6 ft, tilt the flash head downward
k? flash). (p.19)
looks very dark or very bright. osure compensation, For a dark subject, set a 3d flash exposure. And for a bright subject, set an pal flash exposure. (p.14) Ed high-speed sync. bh-speed sync, the effective flash range will be shorter. Make b e subiect is within the effective flash range displayed. (p.17)
shooting mode was set to CAW, and the scene was dark. a tripod or set the shooting mode to . (p.12)
51
I
Specifications TYPe Type: Compatible cameras: Guide No.: Flash coverage:
Oncamera. E-TTL I I I E - M L autoflash Speedlite Type-A EOS cameras (E-TTL IIIE-TTL autoflash) Type-B EOS cameras ( T L autoflash) 581190 (at 105mm focal length, IS0 100 in meterslfeet) 24 - 105mm (14mm wilh wide panel) Auto zoom (Flash coverage set automatically to match lens focal length and image size) Manual zoom Swinginghiltingflash head (bounoe flash) Normal flash: 1.2 ms or shorter, Quick flash: 2.3 ms or st
Flash duration: Color temperature informationtransmission: Flash color temperature informationtransmitted to came when flash is fired
Exposure Control Exposure control system: ErmI I I E - T T m L autoflash, autolmanual external metering, manual flash Effectwe flash range: Normal flash: Approx. 0.5 - 30 m 1 1.6 - 98.4 R. (With EF5Omm 111.4 lens Quick flash: 0.5 - 7.5 m 1 1.6 24.6 R. (min), 0.5 - 21 m I at IS0 100) 68.9 A. (max) High-speedsync: 0.5 - 15 m 11.6 - 49.2 ft. (11250 sec.) Flash exposure Manual, FEE: *3 stops in 1A-stop increments (Manual E compensation: FEB can be combined) FE lock: With button or <*> button High-speed sync: Provided Stroboscopic flash: Provided (1 199 Hz) Flash exposure confirmation: Pilot lamp lights
-
-
Flash Recycling (with size-AA alkaline batteries) Recycling time1 Flash-ready indicator: Normal flash: Approx 0.1 - 5 sec. IRed pilot lamp lights Quick flash: Approx. 0.1 2.5 sac. IGreen pilot lamp ligt
-
m Wi Tran Cha Wire
nFF,Master, and Slave
-
-
Outdoors: 8 10 m 126.2 32.8 R. Master unit reception angle: t40° horizontal, t30' vertical
1:8 - 1:1 - 8:l in ID-stop increments Fired with camera's depth-of-field preview button
-
Periphery: 0.6 - 5 m 12.0 16.4 R.
'Size-AA Ni-MH and lithium batteriesalsb usable
Power off aRer certain period of idle operatian (Approx. 1.5 min. to 15 min.) (60 min. if set as slave) Compact Battery Pack CP-E4 76 x 137 x 117 mm 13.0 x 5.4 x 4.6 in. (excluding dust- and water-resistant adapter)
fications and external appearance are subject to change without
Mw (at IS0 100, in rneterslfeet) Normal Flash (Full Output) and Quick Flash
501
Same -
Manual Flash
164 -
12 to 116 manual flash
I
. autc)flash camera), autoflash, (With a Type-A
JW manual flash slave @@with stroboscopic flash
p-
rasn
lable with Type-B Cameras
wireless slave units
pecified in the instructions. If such changes or modificationsshould be ma you could be required to stop operation of the equipment. This equipment has been tested and found to comply with the limits for a cla B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a frequency energy and, if not installed and used in accordance with the insbuctions, may cause harmful interference to radio communications.
nshine, flre or the
that this product is not to be disposed of with , according to the WEEE Directive (20021961 law This product should be handed over to