Preview only show first 10 pages with watermark. For full document please download

Capture Brightfield Images With Exceptional Detail - Av-iq

   EMBED


Share

Transcript

DP26 specifications Type Imaging sensor DP26 PC configuration system diagram Single chip color CCD camera Microscope Digital Camera Size 2/3 inch color CCD Effective pixels 5.05 megapixels (total: 5.24 megapixels) DP26 DP2-DKTB DP26 Scanning method Progressive scan Color filter RGB Bayer primary color filter Recording range 8.45mm (H)×6.62mm (V) 10.733mm (diagonal length) Mount C-mount Sensitivity Equivalent to ISO 100/200/400 Metering modes 1% center (spot), 30% center (average) Exposure control Auto/Manual Exposure time Auto: 2–1/20,000s Manual: 8–1/20,000s Camera I/F DP26 Camera head DP21-DKT C-mount camera adapter IEEE1394b PC connection Image size (file format) Stand-alone 2448×1920 1224× 960 612× 480 1224× 960 (2×2 binning) 612× 480 (4×4 binning) According to cellSens specifications and ROI available Live image display (frame rate) TIFF JPEG-LOW (Compression ratio 1/2.7) JPEG-HIGH (Compression ratio 1/8) 2448×1920 1224× 960 612× 480 1224× 960 Binning 612× 480 Binning Movie (AVI) 408×320 DP21-LPT PC interface *3 Download from our web site — — Camera head: IEEE1394b (9 pin) For desktop PC system: <1394b cable connection> DP2-DKTB (9 pin): PCI-e slot x1 For desktop PC system: <1394a cable connection> DP21-DKT (6 pin)*1: PCI or PCI-e slot x1 For laptop PC system: DP21-LPT (4 pin): 1394a port (AC adapter connection required to camera head) Camera I/F: IEEE1394b I/F: USB2.0 Display output: DVI-I Digital/Analog RGB Wired LAN: 100Base-TX/10Base-T Serial port: RS-232C D-SUB 9pin According to cellSens specifications View scale/Hide scale Available microscope total magnification: 0.01× to 9999.99× •Up to 8 total magnifications can be set Measuring functions According to cellSens specifications Distance of 2 Points, 3 Points Circle, Distance between 2 Circle Centers, 3 Points Angle, 4 Points Angle, Perpendiculars, Polygon Area, Boundary Length, Distance of Parallel Lines, XY Distance, Count, Poly Line, and Cross Line DP21-DKT: Desktop PC configuration (IEEE1394a combination) DP21-LPT: Laptop PC combination A Superior 5-Megapixel Digital Camera with Intuitive Imaging Software *4 Laptop PC incorporated with IEEE1394a board, or IEEE1394a card required DP26 stand-alone configuration system diagram USB memory, network PC Scale display Camera head AC adapter DP2-DKTB: Desktop PC configuration (IEEE1394b combination) 7 fps 2448×1920 16 fps 1224× 960 16 fps 612× 480 1920×1200 WUXGA (Image display area 1600×1200) 1680×1050 WSXGA+ (Image display area 1280×960) 1280× 854 WSXGA (Image display area 1024× 768) 1280× 768 WXGA (Image display area 1024×768) 1024× 600 WSVGA (Image display area 800×600) 800× 480 WVGA (Image display area 640×480) Capture Brightfield Images with Exceptional Detail Laptop PC*4 1600×1200 UXGA 1280×1024 SXGA (Image display area 1280 x 960) 1280× 960 SXGA 1024× 768 XGA 800× 600 SVGA Storage media cellSens Standard Basic Software or DP2-TWAIN*3 Image Acquisition Software Microscope Power cord 7 fps (resolution: 2448 ×1920) 16 fps (resolution: 1224× 960) 16 fps (resolution: 612× 480) Max. 31 fps (ROI) 3.5 fps (resolution: 2448×1920) 14 fps (resolution: 1224×960) 16 fps (resolution: 612×480: binning) Max. 31 fps (ROI) Compatible image display Desktop PC IEEE1394b Firewire PCI Board DP26 Control unit AC adapter DP26 Camera cable Camera head Power cord Display cable C-mount camera adapter USB memory Microscope Handset Display 77 (W)×84 (D)×42.5 (H) mm Dimensions Control unit — Handset 180 (W)×215 (D)×45 (H) mm — 102 (W)×102 (D)×24 (H) mm (excluding cable) 1 * Commercially available bus powered IEEE1394 board is required System requirements*2 for DP2-TWAIN, cellSens CPU Intel Core i5, Intel Core i7, Intel Xeon (QuadCore CPU recommended) Memory 8 GB or larger recommended (4 GB minimum) HDD Free space of 1 GB or more at the time of installation (SSD Hard disk recommended) Display 1280×1024 recommended (1024×768 or larger), 32-bit video card Drive DVD-ROM drive OS Windows7 Ultimate/Professional (32bit, 64bit) with SP1 Windows Vista Ultimate/Business (32bit) with SP2 Windows XP Professional (32bit) with SP3 OS language Japanese, English Web browser IE8.0 or later *2 Please refer to our website for the applicable PCs Specimen images courtesy of: Dr. Hiroshi Uozaki, Associate Professor, Department of Pathology, Graduate School of Medicine, The University of Tokyo Cover page; page 1, lower right: kidney (IgA nephropathy, Azan); page 1, upper left: liver (fulminant hepatitis, Azan); page 1, lower left: colon (adenocarcinoma, H&E); page 2, upper left: kidney (membranoproliferative glomerulonephritis, Periodic acid-methenamine-silver) • OLYMPUS CORPORATION is ISO14001 certified. • OLYMPUS CORPORATION is FM553994/ISO9001 certified. • All company and product names are registered trademarks and/or trademarks of their respective owners. • Images on the PC monitors are simulated. • Specifications and appearances are subject to change without any notice or obligation on the part of the manufacturer. Shinjuku Monolith, 3-1, Nishi Shinjuku 2-chome, Shinjuku-ku, Tokyo, Japan 21 Gilby Road, Mt. Waverley, VIC 3149, Melbourne, Australia Wendenstrasse 14-18, 20097 Hamburg, Germany 5301 Blue Lagoon Drive, Suite 290 Miami, FL 33126, U.S.A. 3500 Corporate Parkway, Center Valley, Pennsylvania 18034-0610, U.S.A. A8F, Ping An International Financial Center, No. 1-3, Xinyuan South Road, Chaoyang District, Beijing, China, 100027 491B River Vallay Road, #12-01/04 Valley Point Office Tower, Singapore 24837 Printed in Japan M1723E-082012 Not for clinical diagnostic use. Image Quality High Fidelity Color Reproduction Maintains Detail Even After Enlargement Faithful Reproduction Equivalent to Direct View Equipped with an exceptional 5-megapixel CCD, the DP26 digital camera captures images at up to 2448 x 1920 pixel resolution. Large areas captured at low magnification offer exceptionally vivid clarity, even when enlarged several times. The color profile of the DP26 reproduces color faithful to live displayed specimens in real time. Distinguish even the most subtle color differences with natural tones equivalent to those seen through the eyepieces. Comparison of Images (4×) 5 Megapixels 2 Megapixels Observation using 4x objective Smooth, Live Images in Exceptional Detail Capturing Highly Detailed 5-Megapixel Images Just Got Easier Live Display Enhances Identification of Target Sites The DP26 offers smooth 1224 x 960-pixel display in real time at 16 frames per second for more efficient identification of target sites. Furthermore, live display at 2448 x 1920 pixels makes low-magnification focusing (1.25x−4x) easy. Such high-level functionality is supported by progressive scanning that eliminates color shift, while high-speed IEEE 1394b connectivity* adds a further level of versatility. Highly Efficient with a Convenient Handset A Handset Designed for Intuitive Operation As an alternative to a PC-based controller, the DP26 comes also with a convenient handset that allows the user to work comfortably. It enables smooth and easy change of settings, capture of images, simple measurements and data archiving, while its simple key arrangement allows the user to carry out all actions without ever having to glance at a computer keyboard. For added convenience, all captured data can be automatically saved directly to USB memory. The handset is ideal for presentations and teaching environments where the display outputs to a large screen monitor or projector. * Available when connected to a desktop computer and IEEE 1394b card. Greater Convenience cellSens Imaging Software (Not for clinical diagnostic use.) Refined Performance for Ease of Use Adjust white balance, switch to live display and capture images, all at the touch of a button. cellSens offers an array of image processing capabilities, including a versatile shading function that enables real-time correction for variations in peripheral field illumination intensity. In addition, exposure settings, magnifications, and other parameters are saved with acquired images for easy storage and retrieval. DP26 with BX53 Configuration Multiple Functions for Specimen Observation The innovative cellSens software offers a wide array of useful and easy-to-use functions. Split-screen display, for example, provides simultaneous viewing of multiple images, or a live image and the most recently captured image. Pictures taken at adjacent locations can also be stitched together to create a single image using the Multi-Image Array functionality. cellSens software may also store user comments with captured images, which can be referred to as necessary or searched using the cellSens Database. Split-screen Display File Management + + + + Automatic & Manual Image Stitching