Technical features The particular design of this tank offer a larger heating surface (larger than one square meter) wrapped in a special heating cover. Once powered up, the cover reaches a temperature of 120°C and keeps the temperature inside the tank walls at 85°C, increasing the thermal exchange with water and, at the same time, preventing lime scale deposition.
Operational characteristics Cold water flowing into the tank from below is directed along the heated walls, therefore the temperature exchange between water and the walls is more effective and water is heated up more quickly. This results in reduced and optimized power consumption thanks to: (1) The heater layer – which is made up of Carbon Fiber cables (Carbon Fiber reduces power consumption by 40% offering the same temperature) and (2) power consumption restriction (470 W - 1220 W -1470W in “Plus” mode). The process is supervised by an electronic control unit. This control unit, provided with a display, is connected to the two temperature probes, which are working continuously: one of them is installed in the lower part of the tank and the second in the upper part. The control unit allows users to •
Set two working time slots per day.
•
Manage the operational temperature and restrict power consumption according to the user’s demand for hot water.
•
Electric power management.
Advantages Thanks to the characteristics from above, Thermal Technology’s Carbon Boiler is able to:
Thermal Technology® www.thermaltt.com
20
•
produce hot water quantities which cannot be compared with similar water heaters;
•
ensure significant power savings and respect for the environment;
•
economize due to the modulation operation mode, which is a basic requirement for energy savings and rationalization.
TESTED PERFORMANCES DT = 25°C DT = 45°C Maximum operating temperature Thermal loss at 65°C during 24 hrs Quantity of water at 40°C prevailed (Cold water entering temperature: 15°C) 5 minutes long cycles for water at 40°C intake (35 liters inlet water per cycle - 7 liters/1 minute) with 15 min breaks Interval between intakes in minutes (inlet water at 15°C) 7 min long water intake cycles at 40°C (50 l inlet water per cycle - 7 liters/1 min) with 15 min breaks Interval between intakes in minutes (inlet water at 15°C) NUMBER OR PERSONS
TEMPERATURE SETTING
HOT WATER
4 people 3 people 2 people 1 people
65°C 60°C 55°C 45°C
245lt. 190lt. 135lt. 90lt.
POWER CONSUMPTION IN kWh / day 6,25 kWh 5,15 kWh 4,10 kWh 2,45 kWh
Consumption 1,56 kWh Consumption 3,00 kWh
140 lt.
7 cycles
245 liters inlet water
4 cycles
200 liters inlet water
COST €
EXAMPLE
€ 1,13 € 0,93 € 0,74 € 0,45
The above mentioned performance combined with the use of the electronic control unit allow to set the hot water volume in dependence of your needs.
This calculation is made depending on the number of residents; the daily consumption parameters are calculated considering water debit intervals and resetting of the set temperature. The kWh cost used in the calculation is € 0,18.
Technical data
1 hour, 30 minuts 2 hours, 50 minuts 90°C 1,40 kWh
Technical data: A typical Carbon boiler consists of: •
TIG and a micro-plasma AISI 316L welded stainless steel body with pickling treatment both inside and outside.
•
Protection device for residual current and corrosion with a replaceable magnesium anode.
•
Inspection flange (diam. 12cm).
•
Max. operating pressure: 6bar.
•
Hot and cold water connections: 1/2”.
•
High-density, extra-thick (40mm) PU foam insulation -CFC and HCFC-free.
•
Epoxy powder painted steel shell.
•
Anti-static, shock-proof ABS lower and upper plates.
•
Display indicating storage water temperature, operating power range, ON/OFF status, time.
NTA1.A
NTA1.B
NTA1.C
50 250/710 1020 230
75 470/1220 1470 230
100 470/1630 1880 230
h. min.
*
2,32
*
°C kWh/24h bar kg
90 * 6 21
90 1,37 6 29
90 * 6 33
•
Thermostatic valve for manual control of output water temperature.
•
Safety valve (compulsory).
•
Power options: 470W - 1220W - 1470W (ref. to 75lt.).
mm mm mm mm
485 450 560 680
485 450 830 950
485 450 1060 1180
•
Net weight: 29kg ( NTA1.B.C00.2A2).
•
IP40 protection.
Capacity
l
Power
W
Voltage Time to raise temperature (Δt= 45°C) Max operating temperature Heat loss at 65°C Maximum operating pressure Size Dimension A B C D
V
Warranty 5 years (except of failure of electronic components due to electrical phenomena).
Installation recommendations •
Of an expansion tank with hot water adjustment function is highly recommended.
•
Installation of an inlet water pressure adjustment unit.
•
The installation of a water treatment system is highly recommended.
•
For clearing rough water (up to 25°f) we recommend the installation of the polyphosphates dispenser which prevents the limestone ingress into the boiler tank. For cleaning the water rougher than 25°f it is necessary to install the plasticizer (UNI8065 Directive).
21 Thermal Technology® www.thermaltt.com