Transcript
SynthesisTM Casework Medical Catalog Items Installation
Applies to Models: Catalog (E1 thru E7)
Special Tools:
Attention:
Note
none
For OSHPD Regulated Installations, please go to www.midmark.com to download the appropriate OSHPD Pre-Approval and Installation documents.
Language of origin: English
TP200 Rev. A
All Plumbing must be made by a licensed plumbing contractor and conform to local, city, and national codes pertaining to the installation.
© 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
1
Style A
003-2841-00 Rev. A (4/15/15)
Installation Instructions
Table of Contents
TP200 Rev. A
INSTALLATION INSTRUCTIONS Elevations
E1 Exam Room Casework Package............. 3 E2 Exam Room Casework Package............. 4 E3 Exam Room Casework Package............. 5 E4 Exam Room Casework Package............. 6 E5 Exam Room Casework Package............. 7 E6 Exam Room Casework Package............. 8 E7 Exam Room Casework Package............. 9 Overhead Installation.................................10-12 Base Installation............................................. 13 Wall Hanging Sink (ADA) Installation........14-17 Mobile Cart Installation.......................................18 Adjustments.................................................... 19 Handle Installation.......................................... 20
© 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
2
Style A
E1
Drywall N.I.C. 13.88”
48.00”
Support Back N.I.C.
24”
78” 17.91” 19.00”
49.00”
80”
4” Drawer 4” Drawer 36.09”
TP200 Rev. A
34.50”
4.25”
Open Back
15.25”
48.00” RH Sink Shown © 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
3
Style A
003-2841-00
E2
Drywall N.I.C. 48.00”
13.88”
Support Back N.I.C.
24”
17.91”
49.00”
19.00”
78”
80”
4” Drawer 4” Drawer 4” Drawer
34.50” 36.09”
TP200 Rev. A
8” Drawer 4.25”
Open Back
15.25” RH Sink Shown
48.00”
© 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
17.88” 4
Style A
003-2841-00
E3
Drywall N.I.C. 48.00”
13.88”
Support Back N.I.C.
24”
Kydex Contour Top
17.91”
55.00”
19.00”
78”
80”
4” Drawer 4” Drawer
34.50” 36.09”
4” Drawer
TP200 Rev. A
8” Drawer 4.25”
Open Back 27.00” 30.00”
15.25” 24.00”
17.88”
RH Sink Shown © 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
5
Style A
003-2841-00
E4
Drywall N.I.C. 48.00”
13.88”
Support Back N.I.C.
24”
17.91” 49.00”
80”
19.00”
78”
4” Drawer 4” Drawer 33.59”
TP200 Rev. A
34.50”
4.25” 15.25” 24.00”
24.00”
17.88”
RH Sink Shown © 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
6
Style A
003-2841-00
E5
Drywall N.I.C. 13.88”
48.00”
Support Back N.I.C.
24”
Kydex Contour Top
55.00”
19.00”
17.91” 80” 78”
4” Drawer 34.50”
4” Drawer
36.09”
4” Drawer
TP200 Rev. A
8” Drawer
27.00” 30.00”
24.00”
RH Sink Shown © 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
7
Style A
003-2841-00
E6
Drywall N.I.C. 48.00”
13.88”
Support Back N.I.C.
24”
49.00”
19.00”
20.41” 80” 78”
4” Drawer
34.00” (Sink Flange)
4” Drawer
33.59” 8” Drawer
32.00”
TP200 Rev. A
4.25” 15.25” 18.00”
30.00” 17.88”
RH Sink Shown © 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
8
Style A
003-2841-00
E7
Drywall N.I.C. 48.00”
Support Back N.I.C.
13.88”
24”
20.41”
Kydex Contour Top
61.00”
19.00”
80” 78” 34.00”
4” Drawer
(Sink Flange)
4” Drawer
33.59” 32”
TP200 Rev. A
8” Drawer
27.00” 30.00”
30.00”
RH Sink Shown © 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
9
Style A
003-2841-00
Overhead Installation
Hanging Bracket
TP200 Rev. A
Towel Guides
Step 1:
Remove hanging bracket, doors and shelves (if applicable) for easier installation. © 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
10
Style A
003-2841-00
Overhead Installation Ceiling
Ceiling
2-1/16” (5.2 cm) 78” (198.1 cm)
Step 2:
Step 3:
Measure up 78” (198.1 cm) to mark for top of overhead cabinet. Use level to extend line. Note: Make sure line is not longer than overhead cabinet.
Measure 2-1/16” (5.2 cm) lower than the desired height of cabinet top and mark for bottom of hanging bracket. Extend line using level.
Hanging Bracket Top
Attention: Ceiling
TP200 Rev. A
Wall
Step 4:
Mount hanging bracket to wall using hardware (not supplied).
Ceiling
Local, city, or national building codes should be followed before using midmark suggested fasteners for installation.
Note: Suggested Fasteners
- Stud walls (standard): #10 x 2 wood screws (coarse threaded). - Steel studded walls: sheet metal #10 fine screws. - Hollow type or masonry walls: #10 machine screw expansion anchors of adequate length. A 3/16” short molly or other type of fastener may be used if pre-drilled. - Rough solid concrete or brick wall: #10 round head wood screw or a specialized masonry fastener.
Caution
Installer must secure bracket to at least one stud and use wall anchors on any screws that cannot be secured to studs.
© 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
11
Step 5:
Place overhead unit onto hanging bracket. Adjust and level to desired position. Style A
003-2841-00
Overhead Installation 5 oz. Cups 2
1
Shelf Clip
Gloves
Towel Guides
TP200 Rev. A
Z Towels
C Towels
Step 6:
Install Doors, Shelves with Shelf Clips, Gloves, Cups, and Towel Guides with Towels as needed. © 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
12
Style A
003-2841-00
Base Installation
Step 2:
Install Countertop and secure with screws provided.
TP200 Rev. A
Lower Cabinet
Step 1:
Raise Cabinet
Equipment Alert
Do not adjust leveling screws more then 1-1/2 (3.8 cm) to prevent loss of stability.
Move base into position and level as needed.
Equipment Alert
Unit needs to be level to ensure the doors and drawers do not rub wall when opening.
© 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
13
Step 3:
Install Sink into countertop. Note: Use installation instructions provided with sink. Style A
003-2841-00
TP200 Rev. A
Wall Hanging Sink Installation
Step 1:
Remove sink base covers and lay aside for further inatallation. © 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
14
Style A
003-2841-00
Wall Hanging Sink Installation
2-1/2” (6.4 cm) 2-1/8” (5.4 cm)
Equipment Alert
Unit needs to be level to ensure the doors and drawers do not rub wall when opening.
Step 2: E5 & E7
Use level to mark a line from top of connecting cabinet.
Hanging Bracket Top
TP200 Rev. A
Note: Sink Height
For ADA compliance height of top countertop surface or top of sink (whichever is higher) can be no more than 34” Non-ADA sinks have no restrictions on maximum height.
Step 4:
Mount hanging bracket to wall using hardware (not supplied).
Raise Cabinet
Step 2: E3 shown
Measure up to mark desired height of sink cabinet top. Extend line using level.
Wall
Lower Cabinet
Step 3: E3 shown
Measure 2-1/8” (5.4 cm) lower than desired height of sink top and mark for bottom of hanging bracket. Measure 2 1/2” (6.4 cm) from connecting cabinet and mark for start of bracket (if applicable).
Attention:
Local, city, or national building codes should be followed before using midmark suggested fasteners for installation.
Note: Suggested Fasteners
- Stud walls (standard): #10 x 2 wood screws (coarse threaded). - Steel studded walls: sheet metal #10 fine screws. - Hollow type or masonry walls: #10 machine screw expansion anchors of adequate length. A 3/16” short molly or other type of fastener may be used if pre-drilled. - Rough solid concrete or brick wall: #10 round head wood screw or a specialized masonry fastener.
Caution
Installer must secure bracket to at least one stud and use wall anchors on any screws that cannot be secured to studs.
© 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
15
Style A
003-2841-00
Wall Hanging Sink Installation (ADA)
Hex Screws
Hex Screws
L-Bracket
Step 5: E4 &E6 shown
Place unit onto hanging bracket. Secure sink base to connecting cabinet using hex screws provided.
Step 5: E5 & E7 shown
Place sink base onto hanging bracket.
Step 6:
Install L bracket above bottom of plumbing cut-out with hardware (not supplied). Note: Refer to Caution and Notes from step 4.
L-Bracket
TP200 Rev. A
Filler
Step 7: E3; E5; & E7 shown
Attach countertop filler to underside of countertop using hardware supplied. This filler will allow the countertop to be attached to the support bracket so a line accordingly.
Step 7: E3; E5; & E7 shown
Attach support leg onto countertop with L-Bracket using hardware supplied.
© 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
16
Style A
003-2841-00
Wall Hanging Sink Installation (ADA)
Step 8: E5 & E7 shown
Secure countertop to sink using (#10 x 3/4”) wood screws along front and sides of cabinet. Secure L-Bracket to wall and leg with screws provided.
Step 8: E4 & E6 shown
Secure countertop to sink and base unit using (#10 x 3/4”) wood screws along front and sides of cabinet.
Step 8: E3 shown
Secure countertop to base unit using (#10 x 3/4”) wood screws along front and sides of cabinet. Secure L-Bracket to wall and leg with screws provided.
C
TP200 Rev. A
H
Step 9:
Install sink using manufacturer’s instructions.
Step 10:
Reinstall inside front cover under lip. (x2 screws) Reinstall main front cover. (x2 screws)
© 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
17
Style A
003-2841-00
Mobile Cart Installation
C
C
H
H
Step 1: E5 & E7 shown
Step 1: E3 shown
Check Mobile Unit can be moved into place.
TP200 Rev. A
Check Mobile Unit can be moved into place.
© 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
18
Style A
003-2841-00
Door Adjustment
In
Down
Left
Out Right
Door Adjustment Side to Side
Door Adjustment Up and Down
Turn cam screw located in center of mounting plate to adjust door position up or down (+ or - 2 mm).
Door Adjustment Away or Closer
Turn Spiral Tech cam screw located furthest from door to position the door farther from or closer to cabinet (+3 mm or -2 mm).
TP200 Rev. A
Turn screw located closest to door to increase or decrease the door overlay side to side (+ or - 2 mm).
Up
© 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
19
Style A
003-2841-00
Installing Doors & Handles 2
1
Adhesive Covers
Installing Handles (If applicable)
Installing Handles (If applicable)
Removing Drawer (if applicable)
Installing Drawer (if applicable)
TP200 Rev. A
Install door handle using hardware supplied.
Remove drawer buy pulling on sides of drawer to relase tabs and pull forward.
Install drawer handle using hardware supplied. Place adhesive covers over screw heads.
Installing Doors
Install doors as shown.
Slide drawer into back tabs and push down onto slides.
© 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com
20
Style A
003-2841-00