Preview only show first 10 pages with watermark. For full document please download

Casework Medical Catalog Items

   EMBED


Share

Transcript

SynthesisTM Casework Medical Catalog Items Installation Applies to Models: Catalog (E1 thru E7) Special Tools: Attention: Note none For OSHPD Regulated Installations, please go to www.midmark.com to download the appropriate OSHPD Pre-Approval and Installation documents. Language of origin: English TP200 Rev. A All Plumbing must be made by a licensed plumbing contractor and conform to local, city, and national codes pertaining to the installation. © 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com 1 Style A 003-2841-00 Rev. A (4/15/15) Installation Instructions Table of Contents TP200 Rev. A INSTALLATION INSTRUCTIONS Elevations E1 Exam Room Casework Package............. 3 E2 Exam Room Casework Package............. 4 E3 Exam Room Casework Package............. 5 E4 Exam Room Casework Package............. 6 E5 Exam Room Casework Package............. 7 E6 Exam Room Casework Package............. 8 E7 Exam Room Casework Package............. 9 Overhead Installation.................................10-12 Base Installation............................................. 13 Wall Hanging Sink (ADA) Installation........14-17 Mobile Cart Installation.......................................18 Adjustments.................................................... 19 Handle Installation.......................................... 20 © 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com 2 Style A E1 Drywall N.I.C. 13.88” 48.00” Support Back N.I.C. 24” 78” 17.91” 19.00” 49.00” 80” 4” Drawer 4” Drawer 36.09” TP200 Rev. A 34.50” 4.25” Open Back 15.25” 48.00” RH Sink Shown © 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com 3 Style A 003-2841-00 E2 Drywall N.I.C. 48.00” 13.88” Support Back N.I.C. 24” 17.91” 49.00” 19.00” 78” 80” 4” Drawer 4” Drawer 4” Drawer 34.50” 36.09” TP200 Rev. A 8” Drawer 4.25” Open Back 15.25” RH Sink Shown 48.00” © 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com 17.88” 4 Style A 003-2841-00 E3 Drywall N.I.C. 48.00” 13.88” Support Back N.I.C. 24” Kydex Contour Top 17.91” 55.00” 19.00” 78” 80” 4” Drawer 4” Drawer 34.50” 36.09” 4” Drawer TP200 Rev. A 8” Drawer 4.25” Open Back 27.00” 30.00” 15.25” 24.00” 17.88” RH Sink Shown © 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com 5 Style A 003-2841-00 E4 Drywall N.I.C. 48.00” 13.88” Support Back N.I.C. 24” 17.91” 49.00” 80” 19.00” 78” 4” Drawer 4” Drawer 33.59” TP200 Rev. A 34.50” 4.25” 15.25” 24.00” 24.00” 17.88” RH Sink Shown © 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com 6 Style A 003-2841-00 E5 Drywall N.I.C. 13.88” 48.00” Support Back N.I.C. 24” Kydex Contour Top 55.00” 19.00” 17.91” 80” 78” 4” Drawer 34.50” 4” Drawer 36.09” 4” Drawer TP200 Rev. A 8” Drawer 27.00” 30.00” 24.00” RH Sink Shown © 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com 7 Style A 003-2841-00 E6 Drywall N.I.C. 48.00” 13.88” Support Back N.I.C. 24” 49.00” 19.00” 20.41” 80” 78” 4” Drawer 34.00” (Sink Flange) 4” Drawer 33.59” 8” Drawer 32.00” TP200 Rev. A 4.25” 15.25” 18.00” 30.00” 17.88” RH Sink Shown © 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com 8 Style A 003-2841-00 E7 Drywall N.I.C. 48.00” Support Back N.I.C. 13.88” 24” 20.41” Kydex Contour Top 61.00” 19.00” 80” 78” 34.00” 4” Drawer (Sink Flange) 4” Drawer 33.59” 32” TP200 Rev. A 8” Drawer 27.00” 30.00” 30.00” RH Sink Shown © 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com 9 Style A 003-2841-00 Overhead Installation Hanging Bracket TP200 Rev. A Towel Guides Step 1: Remove hanging bracket, doors and shelves (if applicable) for easier installation. © 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com 10 Style A 003-2841-00 Overhead Installation Ceiling Ceiling 2-1/16” (5.2 cm) 78” (198.1 cm) Step 2: Step 3: Measure up 78” (198.1 cm) to mark for top of overhead cabinet. Use level to extend line. Note: Make sure line is not longer than overhead cabinet. Measure 2-1/16” (5.2 cm) lower than the desired height of cabinet top and mark for bottom of hanging bracket. Extend line using level. Hanging Bracket Top Attention: Ceiling TP200 Rev. A Wall Step 4: Mount hanging bracket to wall using hardware (not supplied). Ceiling Local, city, or national building codes should be followed before using midmark suggested fasteners for installation. Note: Suggested Fasteners - Stud walls (standard): #10 x 2 wood screws (coarse threaded). - Steel studded walls: sheet metal #10 fine screws. - Hollow type or masonry walls: #10 machine screw expansion anchors of adequate length. A 3/16” short molly or other type of fastener may be used if pre-drilled. - Rough solid concrete or brick wall: #10 round head wood screw or a specialized masonry fastener. Caution Installer must secure bracket to at least one stud and use wall anchors on any screws that cannot be secured to studs. © 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com 11 Step 5: Place overhead unit onto hanging bracket. Adjust and level to desired position. Style A 003-2841-00 Overhead Installation 5 oz. Cups 2 1 Shelf Clip Gloves Towel Guides TP200 Rev. A Z Towels C Towels Step 6: Install Doors, Shelves with Shelf Clips, Gloves, Cups, and Towel Guides with Towels as needed. © 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com 12 Style A 003-2841-00 Base Installation Step 2: Install Countertop and secure with screws provided. TP200 Rev. A Lower Cabinet Step 1: Raise Cabinet Equipment Alert Do not adjust leveling screws more then 1-1/2 (3.8 cm) to prevent loss of stability. Move base into position and level as needed. Equipment Alert Unit needs to be level to ensure the doors and drawers do not rub wall when opening. © 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com 13 Step 3: Install Sink into countertop. Note: Use installation instructions provided with sink. Style A 003-2841-00 TP200 Rev. A Wall Hanging Sink Installation Step 1: Remove sink base covers and lay aside for further inatallation. © 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com 14 Style A 003-2841-00 Wall Hanging Sink Installation 2-1/2” (6.4 cm) 2-1/8” (5.4 cm) Equipment Alert Unit needs to be level to ensure the doors and drawers do not rub wall when opening. Step 2: E5 & E7 Use level to mark a line from top of connecting cabinet. Hanging Bracket Top TP200 Rev. A Note: Sink Height For ADA compliance height of top countertop surface or top of sink (whichever is higher) can be no more than 34” Non-ADA sinks have no restrictions on maximum height. Step 4: Mount hanging bracket to wall using hardware (not supplied). Raise Cabinet Step 2: E3 shown Measure up to mark desired height of sink cabinet top. Extend line using level. Wall Lower Cabinet Step 3: E3 shown Measure 2-1/8” (5.4 cm) lower than desired height of sink top and mark for bottom of hanging bracket. Measure 2 1/2” (6.4 cm) from connecting cabinet and mark for start of bracket (if applicable). Attention: Local, city, or national building codes should be followed before using midmark suggested fasteners for installation. Note: Suggested Fasteners - Stud walls (standard): #10 x 2 wood screws (coarse threaded). - Steel studded walls: sheet metal #10 fine screws. - Hollow type or masonry walls: #10 machine screw expansion anchors of adequate length. A 3/16” short molly or other type of fastener may be used if pre-drilled. - Rough solid concrete or brick wall: #10 round head wood screw or a specialized masonry fastener. Caution Installer must secure bracket to at least one stud and use wall anchors on any screws that cannot be secured to studs. © 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com 15 Style A 003-2841-00 Wall Hanging Sink Installation (ADA) Hex Screws Hex Screws L-Bracket Step 5: E4 &E6 shown Place unit onto hanging bracket. Secure sink base to connecting cabinet using hex screws provided. Step 5: E5 & E7 shown Place sink base onto hanging bracket. Step 6: Install L bracket above bottom of plumbing cut-out with hardware (not supplied). Note: Refer to Caution and Notes from step 4. L-Bracket TP200 Rev. A Filler Step 7: E3; E5; & E7 shown Attach countertop filler to underside of countertop using hardware supplied. This filler will allow the countertop to be attached to the support bracket so a line accordingly. Step 7: E3; E5; & E7 shown Attach support leg onto countertop with L-Bracket using hardware supplied. © 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com 16 Style A 003-2841-00 Wall Hanging Sink Installation (ADA) Step 8: E5 & E7 shown Secure countertop to sink using (#10 x 3/4”) wood screws along front and sides of cabinet. Secure L-Bracket to wall and leg with screws provided. Step 8: E4 & E6 shown Secure countertop to sink and base unit using (#10 x 3/4”) wood screws along front and sides of cabinet. Step 8: E3 shown Secure countertop to base unit using (#10 x 3/4”) wood screws along front and sides of cabinet. Secure L-Bracket to wall and leg with screws provided. C TP200 Rev. A H Step 9: Install sink using manufacturer’s instructions. Step 10: Reinstall inside front cover under lip. (x2 screws) Reinstall main front cover. (x2 screws) © 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com 17 Style A 003-2841-00 Mobile Cart Installation C C H H Step 1: E5 & E7 shown Step 1: E3 shown Check Mobile Unit can be moved into place. TP200 Rev. A Check Mobile Unit can be moved into place. © 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com 18 Style A 003-2841-00 Door Adjustment In Down Left Out Right Door Adjustment Side to Side Door Adjustment Up and Down Turn cam screw located in center of mounting plate to adjust door position up or down (+ or - 2 mm). Door Adjustment Away or Closer Turn Spiral Tech cam screw located furthest from door to position the door farther from or closer to cabinet (+3 mm or -2 mm). TP200 Rev. A Turn screw located closest to door to increase or decrease the door overlay side to side (+ or - 2 mm). Up © 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com 19 Style A 003-2841-00 Installing Doors & Handles 2 1 Adhesive Covers Installing Handles (If applicable) Installing Handles (If applicable) Removing Drawer (if applicable) Installing Drawer (if applicable) TP200 Rev. A Install door handle using hardware supplied. Remove drawer buy pulling on sides of drawer to relase tabs and pull forward. Install drawer handle using hardware supplied. Place adhesive covers over screw heads. Installing Doors Install doors as shown. Slide drawer into back tabs and push down onto slides. © 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | midmark.com 20 Style A 003-2841-00