Preview only show first 10 pages with watermark. For full document please download

Catalog: Anchoring And Fastening Systems For Concrete And

   EMBED


Share

Transcript

Simpson Strong-Tie ® Anchoring and Fastening Systems for Concrete and Masonry GCN-MEP   Gas-Actuated Concrete Nailer The new GCN-MEP gas-actuated concrete nailer is the ideal solution for attaching light-duty fixtures to concrete and metal deck for mechanical, electrical and plumbing (MEP) applications. Since the tool does not require electrical cords or pneumatic hoses, the gas-actuated GCN-MEP is completely portable, increasing productivity. NEW FEATURES Easy magazine attachment with no extra tools Power to drive .125" diameter pins Pin-depth control dial Easy nose piece change-out (for .25" and .300" headed fasteners) with no extra tools • High-voltage spark for cleaner fuel combustion • Comfortable, “sure-grip” rubber handle • Battery charge indicator light • Ladder hook SPECIFICATIONS • Tool dimensions: • Length – 15.3" (439mm), 17.3" with magazine • Width – 4.2" (107mm) • Height – 15.3" (389mm) • Tool weight: 8.3 lbs (3.7kg) • Suitable Fasteners: • Length – 1⁄2" (12.7mm) to 1 1⁄2" (38mm), • Diameter – For .25" and .300" headed pins • Magazine capacity: 40 + 2 pins* • Average number of shots per fuel cell: 1,200 • Average number of shots per battery charge: 3,300 • 6V NiMH batteries • Average battery charge time: 2 hours • Operates at temperatures between 20°F–120°F (-6°C­– 49°C) • 2 shots per second *To ensure the tool does not discharge without pins in the magazine, all but the last two pins will be used before reloading is necessary. KEY FASTENING APPLICATIONS: • • • • • Conduit clips Ceiling clips Low-voltage cable Cable straps Drywall track to concrete, steel, CMU or lightweight concrete on metal deck with magazine Magazine sold separately (MEP-MAG1KT) Gas and Powder-Actuated Fastening Systems C-SAS-2012 © 2012 Simpson Strong-Tie Company Inc. • • • • The GCN-MEP Gas-Actuated Concrete Nailer Kit includes: • • • • • • • GCN-MEP nailer or GCN-MEPMAG 2 batteries Battery charger Allen wrenches Safety glasses and ear plugs Operator’s manual/tool schematic Rugged tool box Replacement Parts Model Description GCN-APP012 GCN-CHG007 GCN-PPA020 Adaptor Charger (U.S.) Battery (U.S.) GCN-MEPKT or GCN-MEPMAGKT (with magazine) 179 Simpson Strong-Tie ® Anchoring and Fastening Systems for Concrete and Masonry GCN-MEP   Fasteners and Accessories GCN-MEP Gas-Actuated Pins and Assemblies for Mechanical, Electrical and Plumbing (MEP) Applications New, pre-assembled MEP fasteners are available for use with the GCN-MEP gas-actuated concrete nailer designed for high-volume applications such as affixing conduit clips, rod hangers, cable ties and drywall track. With their .300" heads, these versatile pins and assemblies can also be used with common powderactuated tools when fastening into harder substrates (structural steel or extra hard concrete) when required. Codes: ICC-ES ESR-2811 Mechanical, Electrical and Plumbing Pins GCC Model No. GRH25-R100 GRH37-R100 Description ⁄4" Rod Hanger w/ .125" Dia. x 1" Length Pin 3 ⁄8" rod hanger w/ .125" Dia. Shank x 1" Length Pin Pack Qty. 100 100 Compatible Gas-Actuated Nailer GCN-MEP, T3 GCN-MEP, T3 Model No. GCC50-R100 GCC75-R100 GCC100-R100 Description 1 ⁄2" Conduit Clip w/ .125" Dia. x 1" Length Pin 3 ⁄4" Conduit Clip w/ .125" Dia. x 1" Length Pin 1" Conduit Clip w/ .125" Dia. x 1" Length Pin 1" Conduit Clip (13 Gauge Steel) w/ .125" Dia. x 1" Length Pin Pack Qty. 100 100 100 Compatible Gas-Actuated Nailer GCN-MEP, T3 GCN-MEP, T3 GCN-MEP, T3 50 GCN-MEP, T3 Description ⁄2" Conduit Clamp w/ .125" Dia. x 1" Length Pin 3 ⁄4" Conduit Clamp w/ .125" Dia. x 1" Length Pin Pack Qty. 50 25 Compatible Gas-Actuated Nailer GCN-MEP, T3 GCN-MEP, T3 Model No. GAC-R100 Description Angle Clip w/ .125" Dia. x 1" Length Pin Pack Qty. 100 Compatible Gas-Actuated Nailer GCN-MEP, T3 Model No. GCT-R50 Description Tie Strap Holder w/ .125" Dia x 1" Length Pin Pack Qty. 50 Compatible Gas-Actuated Nailer GCN-MEP, T3 Model No. Description ⁄2" Dome Washer w/ .111"/ .125" Dia. x 1⁄2" Length Pin (Step Shank Pin) 1 ⁄2" Dome Washer w/ .125" Dia. x 3⁄4" Length Pin Pack Qty. Compatible Gas-Actuated Nailer 200 GCN-MEP, T3 200 GCN-MEP, T3 ⁄2" Dome Washer w/ .125" Dia. x 1" Length Pin 200 GCN-MEP, T3 Description ⁄4-20 thread, 1⁄2" length thread, 3⁄4" length shank (.125" dia shank) Pack Qty. Compatible Gas-Actuated Nailer 200 GCN-MEP, T3 Model No. Description Pack Qty. Compatible Gas-Actuated Nailer GBR2-R25 2" Dia. Ring, w/ .125" Dia. x 1" Length Pin 25 GCN-MEP, T3 Model No. Description Pack Qty. Compatible Gas-Actuated Nailer GTH-R200 .125" Dia. x 1" Length Pin 200 GCN-MEP, T3 GCC125-R50 Gas and Powder-Actuated Fastening Systems Model No. GCL50-R50 GCL75-R25 GW50-R200 GW75-R200 GW100-R200 1 1 1 Model No. GTS-45075-R200 1 GCL GAC GCT GW GTS GBR GTH GDP Strip Pins (with GCN-MEP MAGKT and 1 fuel cell) 180 NEW Model No. Description Qty. Pins/Pack Compatible Gas-Actuated Nailer + 1 Fuel Cell 1,000 GCN150, GCN-MEP, TF1100, C3 GDP-50KT .106" dia. x ½" pin GDP-562KT .106" dia. x 5⁄8" pin 1,000 GCN150, GCN-MEP, TF1100, C3 GDP-75KT .106" dia. x ¾" pin 1,000 GCN150, GCN-MEP, TF1100, C3 GDP-100KT .106" dia. x 1" pin 1,000 GCN150, GCN-MEP, TF1100, C3 GDP-125KT .106" dia. x 1¼" pin 1,000 GCN150, GCN-MEP, TF1100, C3 GDP-150KT .106" dia. x 1½" pin 1,000 GCN150, GCN-MEP, TF1100, C3 Model No. Description Pack Qty. Compatible Gas-Actuated Nailer GDPS-50 1.09"/1.11" dia. x ½" pin 1,000 GCN150, GCN-MEP, TF1100, C3 GDPS-62 1.09"/1.11" dia. x 5⁄8" pin 1,000 GCN150, GCN-MEP, TF1100, C3 GDPS-75 1.09"/1.11" dia. x ¾" pin 1,000 GCN150, GCN-MEP, TF1100, C3 Model No. Description Pack Qty. Compatible Gas-Actuated Nailer GDPSK-137KT .110" dia. X 13⁄8" spiral knurled pin 1,000 GCN150, GCN-MEP, F100, C3 GDP GDPS GDPSK C-SAS-2012 © 2012 Simpson Strong-Tie Company Inc. All single-shot pins are .125" diameter x 1" except where specified. 1 GRH Simpson Strong-Tie ® Anchoring and Fastening Systems for Concrete and Masonry GCN-MEP   Gas-Actuated Concrete Nailer * GCN-MEP Fasteners - Tension and Shear Loads in Normal-Weight Concrete Model No. GW-75, GW-100, GTH Shank Minimum Diameter Penetration In. In. (mm) (mm) 0.125 (3.2) Allowable Tension Load - lbs. (kN) Allowable Shear Load - lbs. (kN) Minimum Spacing f'c ≥ 2,000 psi f'c ≥ 3,000 psi f'c ≥ 4,000 psi f'c ≥ 2,000 psi f'c ≥ 3,000 psi f'c ≥ 4,000 psi In. (13.8 MPa) (20.7 MPa) (27.6 MPa) (13.8 MPa) (20.7 MPa) (27.6 MPa) (mm) Concrete Concrete Concrete Concrete Concrete Concrete Minimum Edge Distance In. (mm) 5 ⁄8 (15.9) 3 (76.2) 4 (101.6) 60 (0.27) 70 (0.31) 95 (0.42) 55 (0.27) 65 (0.29) 95 (0.42) 3 ⁄4 (19.1) 3 (76.2) 4 (101.6) 85 (0.38) 105 (0.47) 190 (0.85) 120 (0.53) 145 (0.65) 215 (0.96) 1. The fasteners must not be driven until the concrete has reached the designated minimum compressive strength. 2. Minimum concrete thickness must be three times the fastener embedment into the concrete. 3. The allowable tension and shear values are only for the fastener in the concrete. Members connected to the concrete must be investigated in accordance with accepted design criteria. * GCN-MEP Fasteners - Tension and Shear Loads in Sand-Lightweight Concrete over Metal Deck Shank Diameter In. (mm) GW-75, GW-100, GTH 0.125 (3.2) Minimum Penetration In. (mm) Minimum Spacing In. (mm) 5 ⁄8 (15.9) 3 (76.2) 3 ⁄4 (19.1) 3 (76.2) Installed in Concrete Installed Thru. 3-inch "w" deck Allow. Tension Load lbs. (kN) Allow. Shear Load lbs. (kN) Allow. Tension Load lbs. (kN) Allow. Shear Load lbs. (kN) 4 (101.6) 60 (0.27) 110 (0.49) 35 (0.16) 215 (0.96) 4 (101.6) 115 (0.51) 130 (0.58) 55 (0.24) 235 (1.05) *See page 13 for an explanation of the load table icons 1. The fasteners must not be driven through the steel deck and into the light3. The steel deck must have a minimum thickness of 20 gauge and a minimum weight concrete until the lightweight concrete has reached the designated yield strength of 38 ksi. minimum compressive strength. 4. The fasteners must be installed through the steel deck and into the concrete 2. The allowable tension and shear values are only for the fasteners driven at the lower flute. The fastener must be a minimum of 11⁄8" from the edge of the lower flute and 3 inches from the end of the deck. through the steel deck and into the lightweight concrete. Members connected by the fastener, driven through the steel deck and into the lightweight concrete, must be investigated in accordance with accepted design criteria. * C-SAS-2012 © 2012 Simpson Strong-Tie Company Inc. GCN-MEP Fasteners - Tension and Shear Loads in Hollow CMU Installed in CMU Face Shell Model No. Shank Diameter In. (mm) Minimum Penetration In. (mm) Minimum Edge Distance In. (mm) Minimum Spacing In. (mm) Allow. Tension Load – lbs. (kN) Allow. Shear Load – lbs. (kN) GW-75, GW-100, GTH 0.125 (3.2) 5 ⁄8 (15.9) 3 (76.2) 8 (203.2) 55 (0.24) 65 (0.29) GAS ACTUATED FASTENER STEEL THICKNESS 1. The tabulated allowable load values are for the fasteners only. Members connected to the CMU receiving elements shall be designed in accordance with the applicable code and accepted design criteria. 2. The tabulated allowable load values are for fasteners installed in hollow CMUs conforming to ASTM C 90. The minimum allowable nominal size of the CMU must be 8 inches high by 8 inches wide by 16 inches long, with a minimum,1¼"-thick face shell thickness, medium-weight and normal-weight concrete masonry units. 3. The tabulated allowable load values are for fasteners installed in the center of a hollow CMU face shell. Gas and Powder-Actuated Fastening Systems Model No. Minimum Edge Distance In. (mm) ENTIRE POINTED PORTION OF THE FASTENER MUST PENETRATE THROUGH THE STEEL Detail A * GCN-MEP Fasteners - Tension and Shear Loads in Steel Steel Thickness - (In.) Minimum 3 1 3 Minimum ⁄ 16 ⁄4 ⁄8 Edge Spacing Distance Allow. Tension Allow. Shear Allow. Tension Allow. Shear Allow. Tension Allow. Shear In. In. Load – lbs. Load – lbs. Load – lbs. Load – lbs. Load – lbs. Load – lbs. (mm) (mm) (kN) (kN) (kN) (kN) (kN) (kN) Model No. Shank Diameter In. (mm) GW-50, GTH-50 0.111/0.125 (2.8/3.2) ⁄2 (12.7) GW-50, GTH-50 0.111/0.125 (2.8/3.2) ⁄2 (12.7) ASTM A36 1 1 (25.4) 225 (1.00) 400 (1.78) 275 (1.22) 345 (1.53) 2454 (1.09) 3104 (1.38) 3254 (1.45)4 2804 (1.25)4 3504 (1.56)4 ASTM A572 Grade 50 or A992 1 1 (25.4) 240 (1.07) 1. The entire pointed portion of the fastener must penetrate through the steel to obtain the tabulated values, see Detail A, except as noted in footnote 4. 2. The allowable tension and shear values are for the fastener only. Members connected to the steel must be separately in accordance with accepted design criteria.investigated. 380 (1.69) 2154 (0.96)4 3. Steel must conform to ASTM A36 (Fy = 36 ksi, F4 = 58 ksi), ASTM A572 Grade 50 (Fy = 50 ksi, F4 = 65 ksi), or ASTM A992 (Fy = 50 ksi, F4 = 65 ksi). 4. Tabulated values are based on minimum penetration of the fastener point into steel of 0.25 inch (6.4mm). 181