Preview only show first 10 pages with watermark. For full document please download

Catalog- Trane Advantage Vrf Indoor Unit

   EMBED


Share

Transcript

Product Catalog Trane Advantage™ VRF Indoor Unit September 2013 VRF-PRC006-EN Table of Contents Products.................................................................................................................................................................... 5 Slim 1 way cassette................................................................................................................................................ 8 1-1. Specifications......................................................................................................................................................................8 1-2. Dimensional drawing.........................................................................................................................................................9 1-3. Electrical wiring diagram.................................................................................................................................................10 1-4. Sound pressure level.......................................................................................................................................................11 1-5. Temperature and air flow distribution...........................................................................................................................12 Mini 4 way cassette.............................................................................................................................................. 13 2-1. Specifications....................................................................................................................................................................13 2-2. Dimensional drawing.......................................................................................................................................................14 2-3. Electrical wiring diagram.................................................................................................................................................15 2-4. Sound pressure level.......................................................................................................................................................16 2-5. Temperature and air flow distribution.............................................................................................................................17 4 way cassette....................................................................................................................................................... 19 3-1. Specifications....................................................................................................................................................................19 3-2. Dimensional drawing.......................................................................................................................................................21 3-3. Electrical wiring diagram..................................................................................................................................................22 3-4. Sound pressure level.......................................................................................................................................................23 3-5. Temperature and air flow distribution...........................................................................................................................24 Slim duct................................................................................................................................................................ 33 4-1. Specifications....................................................................................................................................................................33 4-2. Dimensional drawing.......................................................................................................................................................35 4-3. Electrical wiring diagram.................................................................................................................................................38 4-4. Sound pressure level.......................................................................................................................................................40 4-5. Recommended operation range....................................................................................................................................42 2 VRF-PRC006-EN MSP (Middle static pressure) duct..................................................................................................................... 44 5-1. Specifications....................................................................................................................................................................44 5-2. Dimensional drawing.......................................................................................................................................................46 5-3. Dimensional drawing.......................................................................................................................................................48 5-4. Electrical wiring diagram.................................................................................................................................................49 5-5. Sound pressure level.......................................................................................................................................................50 5-6. Recommended operation range....................................................................................................................................52 HSP (High static pressure) duct.......................................................................................................................... 53 Indoor units 6-1. Specifications....................................................................................................................................................................53 6-2. Dimensional drawing.......................................................................................................................................................54 6-3. Electrical wiring diagram.................................................................................................................................................56 6-4. Sound pressure level.......................................................................................................................................................57 6-5. Recommended operation range....................................................................................................................................58 Ceiling Suspended (Floor)................................................................................................................................... 59 7-1. Specifications....................................................................................................................................................................59 7-2. Dimensional drawing.......................................................................................................................................................60 7-3. Electrical wiring diagram.................................................................................................................................................61 7-4. Sound pressure level.......................................................................................................................................................62 7-5. Temperature and air flow distribution...........................................................................................................................63 High Wall................................................................................................................................................................ 65 8-1. Specifications....................................................................................................................................................................65 8-2. Dimensional drawing.......................................................................................................................................................67 8-3. Electrical wiring diagram.................................................................................................................................................69 8-4. Sound pressure level.......................................................................................................................................................70 8-5. Temperature and air flow distribution...........................................................................................................................72 EEV Kit Application Table.................................................................................................................................... 74 VRF-PRC006-EN 3 Nomenclature Indoor Units Nomenclature 4 T V D 0 0 1 8 B 1 0 0 N B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Digit 1 — Refrigerant 4 = R-410a Digit 2 — Brand Name T = Trane Digit 3 — System Type V = Variable Refrigerant Flow Digit 4 — Configuration Type A B C D E L X W = = = = = = = = High Pressure Static Duct Type Mini 4-Way Cassette 4-Way Cassette Mid Pressure Static Duct Type 1-Way Cassette Slim Duct Type (Low Pressure) Convertible Floor/Ceiling High Wall Type Digit 5 — Reserved for Future Use Digit 11 — Reserved for Future Use 0 0 = Not currently used = Not currently used Digit 6, 7, 8 — Nominal Capacity (Btu/h x 1,000) Digit 12 — Reserved for Future Use 007= 009= 012= 015= 018= 024= 030= 036= 048= 076= 096= 0 7,000 Btu/h 9,000 Btu/h 12,000 Btu/h 15,000 Btu/h 18,000 Btu/h 24,000 Btu/h 30,000 Btu/h 36,000 Btu/h 48,000 Btu/h 76,000 Btu/h 96,000 Btu/h = Not currently used Digit 13 — Region of Sale N = North America (UL or ETL) Digit 14 — Minor Design Sequence B = Second Design Sequence Digit 9 — Major Development Sequence B = Second Development Sequence Digit 10 — Electric Power Supply Characteristics 1 = 208~230/60/1 VRF-PRC008-EN 4 5 VRF-PRC006-EN VRF-PRC008-EN.book Page 6 Thursday, August 15, 2013 4:08 PM 1 Products Products Application Matrix Capacity Type 7.5MBH 9.0MBH 9.5MBH 12MBH 18MBH 20MBH 24MBH 30MBH 36MBH 48MBH 76.8MBH 96MBH Slim 1 way cassette Indoor units 4 way cassette Mini 4 way cassette Slim duct MSP duct HSP duct Ceiling High Wall 6 VRF-PRC006-EN VRF-PRC008-EN 5 Products Products Controls Family Integrated System Management Building Management System Gateways Centralized Control Systems Zone Controllers Interface Modules Sensors Commissioning and Utility Kits VRF-PRC008-EN 6 Description Trane Model Number VRF System Controller TVCTRLTIMD00A0 VRF Enterprise Management Software TVCTRLTSTP3P00 VRF Power Meter Interface Module TVCTRLTIMB16A0 VRF System Controller+BACnet TVCTRLTIMB17A0 VRF System Controller+LONTalk TVCTRLTIMB18A0 VRF Central On/Off Controller TVCTRLTCMA202D VRF System TouchScreen Control TVCTRLTCMA300T VRF Mode Select Switch TVCTRLTCMC2000 VRF Wireless Remote Control TVCTRLTRDH00UT VRF Wired Remote Control TVCTRLTWRWE10T VRF Duct Signal Receiver & Wire TVCTRLTRKA10N0 VRF External Contact Interface Module TVCTRLTIMB14A0 VRF Ext. Room Temp Sensor TVCTRLTRWTA000 VRF Motion Sensor Mini 4Way MOTIONSEN4TVB VRF Auto-Commissioning Tool TVCTRLTIMC1000 VRF Technician Utilities TVCTRLTIMC0300 7 VRF-PRC006-EN Products Accessories Family Y-joint (High Pressure Gas for HR) Outdoor T Joint (Outdoor Connection) Header Joint MCU-KIT EEV Kits (For Wall-mounted & Ceiling indoor unit AHU Kit DRAIN PUMP CASSETTE PANEL 8 VRF-PRC006-EN Trane Model Number 4YDK1509B0051A VRF Y-joint 51-138MBh 4YDK2512B0138A VRF Y-joint 138-160MBh 4YDK2812B0160A VRF Y-joint 160-240MBh 4YDK2815B0240A VRF Y-joint 240-336MBh 4YDK3419B0336A VRF Y-joint 336-468MBh 4YDK4119B0468A VRF Y-joint >468MBh 4YDK4422B0999A VRF Y-joint HR ≤80MBh 4YDK1500B0080A VRF Y-joint HR 80-240MBh 4YDK2500B0240A VRF Y-joint HR 240-468MBh 4YDK3100B0468A VRF Y-joint HR >468MBh 4YDK3800B0999A VRF T-joint ≤468MBh 4TDK3819B0000A VRF T-joint HR ≤468MBh 4TDK3100B0000A VRF Header Joint 4Units <160MBh 4HJK2512B0159A VRF Header Joint 8Units ≤240MBh 4HJK3115B0241A VRF Header Joint 8Units >240MBh 4HJK3819B0998A VRF MCU Kit up to 6 IDU 4MCUCUY6NCE000 VRF MCU Kit up to 4 IDU 4MCUCUY4NCE000 VRF MCU Kit 2 IDU HSP Only 4MCUCUY2NCE000 VRF EEV 1x 7-15.5& 1x 17-31MBh 4EEVXDA24K132A VRF EEV Kit 2Unit 7-15.5MBh 4EEVXDA24K200A VRF EEV Kit 2Unit 17-31MBh 4EEVXDA32K200A VRF EEV 2x 7-15.5& 1x 17-31MBh 4EEVXDA24K232A VRF EEV Kit 3Unit 7-15.5MBh 4EEVXDA24K300A VRF EEV 1x 7-15.5& 2x 17-31MBh 4EEVXDA32K224A VRF EEV Kit 3Unit 17-31MBh 4EEVXDA32K300A VRF EEV Kit 1Unit 7-15.5MBh 4EEVEVA24SA000 VRF EEV Kit 1Unit 17-31MBh 4EEVEVA32SA000 VRF AHU Kit 24-30MBh 4EEVAKA40K1025 VRF AHU Kit 48-60MBh 4EEVAKA40K1050 VRF AHU Kit 72-90MBh 4EEVAKA64K1075 VRF AHU Kit 96-112MBh 4EEVAKA64K1100 VRF Drain Pump Slim Duct CONDPUMPXVLB01 VRF Drain Pump MSP 18/24MBh CONDPUMPXVMB01 VRF Drain Pump MSP 30/36MBh CONDPUMPXVMB02 VRF Drain Pump MSP48/ HSP36-48MBh CONDPUMPXVDB01 VRF Drain Pump HSP 76.8/96MBh CONDPUMPXVHB01 VRF Cassette Panel Slim 1Way TVEPANPC1NUSET VRF Cassette Panel Sliding 1Way TVEPANPC1NUAET VRF Cassette Panel Mini 4Way TVEPANPC4SUSET VRF Cassette Panel 4Way TVEPANPC4NUSET Indoor units Y- joint Description VRF Y-joint <51MBh VRF-PRC008-EN 7 1 Slim 1 way cassette 1-1. Specifications Technical specifications Model Name 4TVE0007B100NB 4TVE0009B100NB 4TVE0012B100NB Power Supply 208~230/60/1 208~230/60/1 208~230/60/1 Performance Capacity (Nominal)1 Cooling Btu/h 7,500 9,500 12,000 Heating Btu/h 8,500 10,500 13,500 Power Input (Nominal)1 Cooling 40.0 45.0 50.0 40.0 45.0 50.0 Current Input (Nominal)1 Cooling 0.23 0.25 0.28 0.23 0.25 0.28 Power Motor Fan Piping Connections Refrigerant Sound2 External Dimensions Heating Heating Additional Features - Crossflow Fan Crossflow Fan Crossflow Fan Output (Each) W 20 x 1 20 x 1 20 x 1 280/245/210 Airflow Rate H/M/L External Static Pressure Min/Std/Max CFM 245/210/175 245/210/175 in. WG - - - Liquid Pipe Ø inch 1/4 1/4 1/4 Gas Pipe Ø inch 1/2 1/2 1/2 Drain Pipe Ø inch VP 20 (OD 1", ID 3/4") VP 20 (OD 1", ID 3/4") VP 20 (OD 1", ID 3/4") Type - R410A R410A R410A Control Method - EEV (Included) EEV (Included) EEV (Included) dB(A) 27.0/25.0/23.0 29.0/27.0/24.0 35.0/31.0/27.0 Net Weight lbs. 23.15 23.15 23.15 Shipping Weight lbs. 29.75 29.75 29.75 Net Dimensions (Wxhxd) inches 38 1/4 x 5 3/8 x 16 1/8 38 1/4 x 5 3/8 x 16 1/8 38 1/4 x 5 3/8 x 16 1/8 Shipping Dimensions (Wxhxd) inches 43 7/8 x 8 3/8 x 15 13/16 43 7/8 x 8 3/8 x 15 13/16 43 7/8 x 8 3/8 x 15 13/16 - TVEPANPC1NUSET TVEPANPC1NUSET TVEPANPC1NUSET - TVEPANPC1NUAET TVEPANPC1NUAET TVEPANPC1NUAET Net Weight lbs. 6.61 6.61 6.61 Shipping Weight lbs. 11.0 11.0 11.0 Sound Pressure H/M/L Net Dimensions (Wxhxd) inches 46 1/2 x 1.0 x 18 1/8 46 1/2 x 1.0 x 18 1/8 46 1/2 x 1.0 x 18 1/8 Shipping Dimensions (Wxhxd) inches 49 5/8 x 5 11/16 x 21.25 49 5/8 x 5 11/16 x 21.25 49 5/8 x 5 11/16 x 21.25 Model Name - Built-in Built-in Built-in Max. Lifting Height inches 29.5 29.5 29.5 Displacement Gal/Hr. 6.25 6.25 6.25 - Washable Filter Washable Filter Washable Filter Drain Pump Air Filter 1. 2. 3. 4. 8 A Type (Qty.) Model Name Cassette Panel3 W Nominal capacity based on 25 ft. of equivalent refrigerant piping with 0 ft. level difference. - Cooling: Indoor temperature 80°F DB, 67°F WB/Outdoor temperature 95°F DB, 75°F WB - Heating: Indoor temperature 70°F DB, 60°F WB/Outdoor temperature 47°F DB, 43°F WB Sound pressure was acquired in a dead room. Actual noise level may be different depending on installation conditions. Cassette panel must be ordered separately Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. VRF-PRC006-EN 1-2. Dimensional drawing Unit: mm(inch) Indoor units 280(11) 410(16-1/8) 4 970(38-1/4) 1036(40-3/4) Suspension bolts(M8~M10) X 4EA 2 25(1) 3 135(5-3/8) 150(5-7/8) 85(3-3/8) 415(16-3/8) 52(2-1/16) 119(4-5/8) 160(6-1/4) 50(1-15/16) 1 1180(46-1/2) 6 863(34) 460(18-1/8) 197(7-3/4) 94(3-3/4) 5 861(33-7/8) No. Name 1 Liquid pipe connection Gas pipe connection Drain pipe connection Conduit for power supply & communication wiring Air inlet grille Air outlet louver 2 3 4 5 6 VRF-PRC006-EN Description 7.5 MBH 9.5 MBH 12.0 MBH Ø6.35(1/4") Flare Ø12.70(1/2") Flare VP20 (OD 26, ID 20) / VP20 (OD 1", ID 3/4") - 9 1 Slim 1 way cassette 1-3. Electrical wiring diagram 10 VRF-PRC006-EN 1-4. Sound pressure level Operation sound level Unit : dB(A) 1m 1m Model High Low 4TVE0007B100NB 27 23 4TVE0009B100NB 29 24 4TVE0012B100NB 35 27 Microphone Indoor units  Note  These operation values were obtained in an anechoic room. Sound pressure level will vary depending on a range of factors such as the construction of the particular room where the equipment is installed.  Operation sound level may differ depending on operation and ambient conditions. 2) NC curves (1) 4TVE0007B100NB (2) 4TVE0009B100NB 45 45 NC 45 NC 40 35 30 NC 35 HIGH NC 30 25 LOW 20 NC 25 15 NC 20 10 NC 15 5 0 NC 45 40 Sound pressure level (dB) Sound pressure level (dB) 40 NC 40 35 HIGH NC 35 30 25 NC 30 LOW 20 NC 25 15 NC 20 10 NC 15 5 63 125 250 500 1000 2000 4000 0 8000 Octave band center frequency(Hz) 63 125 250 500 1000 2000 4000 8000 Octave band center frequency(Hz) (3) 4TVE0012B100NB 45 NC 45 40 Sound pressure level (dB) HIGH NC 40 35 30 NC 35 LOW NC 30 25 20 NC 25 15 NC 20 10 NC 15 5 0 63 125 250 500 1000 2000 4000 8000 Octave band center frequency(Hz) VRF-PRC006-EN 11 1 Slim 1 way cassette 1-5. Temperature and air flow distribution 4TVE0007-0012B100NB (1) Cooling air velocity distribution  Discharge angle : 60° 3m (9.8 ft) Ceiling height 1.0m/s (3.28ft/s) 0.2m/s (0.66ft/s) 0m (0 ft) 2m (6.6 ft) 1m (3.3 ft) 2m (6.6 ft) 0.8m/s (2.62ft/s) 1m (3.3 ft) 0.2m/s (0.66ft/s) 0.6m/s 0.6m/s (1.97ft/s) (1.97ft/s) 3m (9.8 ft) 5m 4m (16.4 ft) (13.1 ft) Floor distance 6m (19.7 ft) 2) Cooling temperature distribution 7m (23.0 ft) 8m (26.2 ft)  Discharge angle : 60° Ceiling height 3m (9.8 ft) 22 (71.6°F) 25 (77.0°F) 2m (6.6 ft) 25 (77.0°F) 1m (3.3 ft) 23 (73.4°F) 0m (0 ft) 1m (3.3 ft) 24 (75.2°F) 23 (73.4°F) 24 (75.2°F) 2m (6.6 ft) 5m 3m 4m (16.4 ft) (9.8 ft) (13.1 ft) Floor distance 6m (19.7 ft) 3) Heating air velocity distribution 7m (23.0 ft)  Discharge angle : 60° 3m (9.8 ft) 0.2m/s (0.66ft/s) 0.4m/s (1.31ft/s) Ceiling height 8m (26.2 ft) 2m (6.6 ft) 0.6m/s (1.97ft/s) 1m (3.3 ft) 0.4m/s (1.31ft/s) 0.2m/s (0.66ft/s) 0m (0 ft) 1m (3.3 ft) 2m (6.6 ft) 5m 3m 4m (16.4 ft) (9.8 ft) (13.1 ft) Floor distance 6m (19.7 ft) 4) Heating temperature distribution 7m (23.0 ft)  Discharge angle : 60° 3m (9.8 ft) Ceiling height 23 (73.4°F) 25 (77.0°F) 33 (91.4°F) 31 (87.8°F) 23 (73.4°F) 27 (80.6°F) 8m (26.2 ft) 2m (6.6 ft) 25 (77.0°F) 1m (3.3 ft) 21 (69.8°F) 0m (0 ft) 12 1m (3.3 ft) 2m (6.6 ft) 5m 3m 4m (16.4 ft) (9.8 ft) (13.1 ft) Floor distance 6m (19.7 ft) 7m (23.0 ft) 8m (26.2 ft) VRF-PRC006-EN 12 Mini 4 way cassette 2-1. Specifications Technical specifications Model Name Power Supply Performance Sound2 External Dimensions 208~230/60/1 208~230/60/1 208~230/60/1 208~230/60/1 Capacity (Nominal)1 9,500 12,000 18,000 20,000 Heating Btu/h 10,500 13,500 20,000 23,000 Power Input (Nominal)1 Cooling 24.0 28.0 36.0 38.0 24.0 28.0 36.0 38.0 Current Input (Nominal)1 Cooling 0.17 0.19 0.27 0.30 Heating Heating Type (Qty.) Output (Each) A - 0.17 0.19 0.27 0.30 Turbo Fan Turbo Fan Turbo Fan Turbo Fan W 65 x 1 65 x 1 65 x 1 65 x 1 350/300/265 370/335/280 460/390/335 475/425/360 In. WG - - - - Liquid Pipe Ø inch 1/4 1/4 1/4 1/4 Gas Pipe Ø inch 1/2 1/2 1/2 Drain Pipe Ø inch H/M/L External Static Pressure Min/Std/Max Type - Control Method VP 25 (OD 1 1/4", ID 1") VP 25 (OD 1 1/4", ID 1") VP 25 (OD 1 1/4", ID 1") R410A R410A R410A 1/2 VP 25 (OD 1 1/4", ID 1") R410A - EEV (Included) EEV (Included) EEV (Included) EEV (Included) Db(A) 34.0/30.0/26.0 36.0/34.0/31.0 40.0/37.0/34.0 41.0/38.0/35.0 Net Weight lbs. 26.5 26.5 26.5 26.5 Shipping Weight lbs. 30.9 30.9 30.9 30.9 22 3/4 x 9 3/4 22 3/4 22 3/4 x 9 3/4 22 3/4 22 3/4 x 9 3/4 22 3/4 Sound Pressure H/M/L Net Dimensions (WxHxD) inches Shipping Dimensions (WxHxD) inches Net Weight Shipping Weight 24 1/2 x 11 3/4 x 22 3/4 24 1/2 x 11 3/4 x 22 3/4 24 1/2 x 11 3/4 x 22 3/4 22 3/4 x 9 3/4 22 3/4 24 1/2 x 11 3/4 x 22 3/4 - TVEPANPC4SUSET TVEPANPC4SUSET TVEPANPC4SUSET TVEPANPC4SUSET lbs. 6 6 6 6 lbs. 9.25 9.25 9.25 9.25 Net Dimensions (WxHxD) inches 26 3/8 X 1 3/4 X 26 3/8 26 3/8 X 1 3/4 X 26 3/8 26 3/8 X 1 3/4 X 26 3/8 26 3/8 X 1 3/4 X 26 3/8 Shipping Dimensions (WxHxD) inches 28 1/8 X 4 3/16 X 28 1/2 28 1/8 X 4 3/16 X 28 1/2 28 1/8 X 4 3/16 X 28 1/2 28 1/8 X 4 3/16 X 28 1/2 Model Name Drain Pump Additional Features 1. 2. 3. 4. 5. W Cfm Airflow Rate Model Name Cassette Panel3 4TVB0020B100NB Indoor units Refrigerant 4TVB0018B100NB Btu/h Motor Piping Connections 4TVB0012B100NB Cooling Power Fan 4TVB0009B100NB - Built-in Built-in Built-in Built-in Max. Lifting Height inches 29.5 29.5 29.5 29.5 Displacement Gal/Hr. 6.25 6.25 6.25 6.25 Air Filter - Washable Filter Washable Filter Washable Filter Washable Filter Motion Sensor4 - MOTIONSEN4TVB MOTIONSEN4TVB MOTIONSEN4TVB MOTIONSEN4TVB Nominal capacity based on 25 ft. of equivalent refrigerant piping with 0 ft. level difference. - Cooling: Indoor temperature 80°F DB, 67°F WB/Outdoor temperature 95°F DB, 75°F WB - Heating: Indoor temperature 70°F DB, 60°F WB/Outdoor temperature 47°F DB, 43°F WB Sound pressure was acquired in a dead room. Actual noise level may be different depending on installation conditions. Cassette panel must be ordered separately Motion sensor must be ordered separately Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. VRF-PRC006-EN 13 2 Mini 4 way cassette 2-2. Dimensional drawing Unit: mm(inch) 585-630(23-24.8) Ceiling opening 500(19.7) Suspension position 585-630(23-24.8) Ceiling opening 500(19.7) Suspension position 1 3 2 575(22.6) .9" 47.5(1.9) 575(22.6) 47.5(1.9) 47.5(1.9) 4 575(22.6) 47.5(1.9) 41(1.6) ) 7 165(6.5) 249(9.8) 269(10.6) 40(1.6) 131(5.2) 250(9.8) 225(8.9) 295(11.6) 43(1.7) 195(7.7) 00(3 176(6.9) Ø1 670(26.4) 5 57(2.2) 381(15) 381(15) 670(26.4) 6 120(4.7) 300(11.8) 150(5.9) No. Name 1 Liquid pipe connection Gas pipe connection Drain pipe connection Conduit for power supply & communication wiring Air inlet grille Air outlet louver Fresh air intake 2 3 4 5 6 7 14 Description 9.5 MBH 12.0 MBH 18.0 MBH 20.0 MBH Ø6.35(1/4") Flare Ø12.70(1/2") Flare VP25 (OD 32, ID 25)/VP25 (OD 1 1/4", ID 1") Ø100(3.9") VRF-PRC006-EN 2-3. Electrical wiring diagram Indoor units VRF-PRC006-EN 15 2 Mini 4 way cassette 2-4. Sound pressure level Operation sound level Unit : dB(A) Model 4TVB0009B100NB 4TVB0012B100NB 4TVB0018B100NB 4TVB0020B100NB 1.5m Microphone High Low 34 36 40 41 26 31 34 35  Note  These operation values were obtained in an anechoic room. Sound pressure level will vary depending on a range of factors such as the construction of the particular room where the equipment is installed.  Operation sound level may differ depending on operation and ambient conditions. 2) NC curves (2) 4TVB0012B100NB 60 60 50 50 NC 45 40 NC 40 HIGH 30 NC 35 Mid LOW NC 30 NC 25 20 NC 20 NC 15 10 0 63 125 250 500 1000 2000 4000 Sound pressure level (dB) Sound pressure level (dB) (1) 4TVB0009B100NB 40 NC 25 20 NC 20 NC 15 10 63 500 1000 2000 4000 8000 60 50 HIGH Mid NC 45 LOW NC 40 NC 35 30 NC 30 NC 25 20 NC 20 NC 15 10 63 125 250 500 1000 2000 4000 Octave band center frequency(Hz) 8000 Sound pressure level (dB) Sound pressure level (dB) 250 (4) 4TVB0020B100NB 60 16 125 Octave band center frequency(Hz) (3) 4TVB0018B100NB 0 NC 35 NC 30 Octave band center frequency(Hz) 40 NC 40 30 0 8000 NC 45 HIGH Mid LOW 50 HIGH Mid 40 NC 45 LOW NC 40 NC 35 30 NC 30 NC 25 20 NC 20 NC 15 10 0 63 125 250 500 1000 2000 4000 8000 Octave band center frequency(Hz) VRF-PRC006-EN 2-5. Temperature and air flow distribution 4TVB0009-0012B100NB (1) Cooling air velocity distribution  Discharge angle : 37° 3m (9.8 ft) 0.6m/s (1.97ft/s) Ceiling height 0.6m/s (1.97ft/s) 2m (6.6 ft) 0.4m/s (1.31ft/s) 0.4m/s (1.31ft/s) 2.5 m (8.2 ft) 1m (3.3 ft) 0.2m/s (0.66ft/s) 1.5 m (4.9 ft) 0m (0 ft) Floor distance 1.5m (4.9 ft) Indoor units 0.2m/s (0.66ft/s) 2.5 m (8.2 ft) (2) Cooling temperature distribution  Discharge angle : 37° Ceiling height 3m (9.8 ft) 21 (69.8°F) 24 (75.2°F) 21 (69.8°F) 22 (71.6°F) 24 (75.2°F) 22 (71.6°F) 23 (73.4°F) 23 (73.4°F) 24 (75.2°F) 2.5 m (8.2 ft) 1.5 m (4.9 ft) 0m (0 ft) Floor distance 1.5m (4.9 ft) 2m (6.6 ft) 1m (3.3 ft) 2.5 m (8.2 ft) (3) Heating air velocity distribution  Discharge angle : 49° 3m (9.8 ft) Ceiling height 1.0m/s (3.28ft/s) 1.0m/s (3.28ft/s) 0.8m/s (2.62ft/s) 0.6m/s (1.97ft/s) 0.4m/s (1.31ft/s) 0.2m/s (0.66ft/s) 2.5 m (8.2 ft) 1.5 m (4.9 ft) 0.8m/s (2.62ft/s) 0.6m/s (1.97ft/s) 0.4m/s (1.31ft/s) 0.2m/s (0.66ft/s) 0m (0 ft) Floor distance 1.5m (4.9 ft) 2m (6.6 ft) 1m (3.3 ft) 2.5 m (8.2 ft) (4) Heating temperature distribution  Discharge angle : 49° 3m (9.8 ft) Ceiling height 31 (87.8°F) 27 (80.6°F) 29 (84.2°F) 25 (77.0°F) 31 (87.8°F) 29 (84.2°F) 2m (6.6 ft) 27 (80.6°F) 1m (3.3 ft) 23 (73.4°F) 21 (69.8°F) 2.5 m (8.2 ft) VRF-PRC006-EN 1.5 m (4.9 ft) 0m (0 ft) Floor distance 1.5m (4.9 ft) 2.5 m (8.2 ft) 17 2 Mini 4 way cassette 4TVB0018-0020B100NB (1) Cooling air velocity distribution  Discharge angle : 37° 3m (9.8 ft) Ceiling height 0.8m/s (2.62ft/s) 0.8m/s (2.62ft/s) 0.4m/s (1.31ft/s) 2.5 m (8.2 ft) 1m (3.3 ft) 0.4m/s (1.31ft/s) 0.2m/s (0.66ft/s) 0.2m/s (0.66ft/s) 1.5 m (4.9 ft) 2m (6.6 ft) 0.6m/s (1.97ft/s) 0.6m/s (1.97ft/s) 0m (0 ft) Floor distance 2.5 m (8.2 ft) 1.5m (4.9 ft) (2) Cooling temperature distribution Ceiling height 25 (77.0°F)  Discharge angle : 37° 25 (77.0°F) 20 (68.0°F) 20 (68.0°F) 24 (75.2°F) 24 (75.2°F) 24 (75.2°F) 2.5 m (8.2 ft) 2m (6.6 ft) 23 (73.4°F) 23 (73.4°F) 1.5 m (4.9 ft) 0m (0 ft) Floor distance 1.5m (4.9 ft) 3m (9.8 ft) 1m (3.3 ft) 2.5 m (8.2 ft) (3) Heating air velocity distribution  Discharge angle : 49° 3m (9.8 ft) Ceiling height 0.8m/s (2.62ft/s) 0.8m/s (2.62ft/s) 0.4m/s (1.31ft/s) 2m (6.6 ft) 0.6m/s (1.97ft/s) 0.6m/s (1.97ft/s) 1m (3.3 ft) 0.2m/s (0.66ft/s) 2.5 m (8.2 ft) 1.5 m (4.9 ft) 0m (0 ft) Floor distance 1.5m (4.9 ft) 2.5 m (8.2 ft) (4) Heating temperature distribution  Discharge angle : 49° Ceiling height 3m (9.8 ft) 31 (87.8°F) 31 (87.8°F) 29 (84.2°F) 27 (80.6°F) 25 (77.0°F) 29 (84.2°F) 2m (6.6 ft) 27 (80.6°F) 1m (3.3 ft) 23 (73.4°F) 21 (69.8°F) 2.5 m (8.2 ft) 18 1.5 m (4.9 ft) 0m (0 ft) Floor distance 1.5m (4.9 ft) 2.5 m (8.2 ft) VRF-PRC006-EN 13 4 way cassette 3-1. Specifications Technical specifications Model Name Power Supply Performance 208~230/60/1 208~230/60/1 Capacity (Nominal)1 9,000 18,000 24,000 Heating Btu/h 10,000 20,000 27,000 Power Input (Nominal)1 Cooling 32.0 32.0 40.0 32.0 32.0 40.0 Current Input (Nominal)1 Cooling 0.25 0.25 0.30 Heating Heating Type (Qty.) Output (Each) Airflow Rate H/M/L External Static Pressure Min/Std/Max Piping Connections Gas Pipe Drain Pipe External Dimensions Type Control Method 0.25 0.25 0.30 Turbo Fan Turbo Fan Turbo Fan W 65 x 1 65 x 1 65 x 1 Cfm 510/460/390 545/495/425 615/565/495 In. WG - - - Ø inch 1/4 1/4 1/4 Ø inch 1/2 1/2 1/2 Ø inch VP 25 (OD 1 1/4", ID 1") VP 25 (OD 1 1/4", ID 1") VP 25 (OD 1 1/4", ID 1") - R410A R410A R410A EEV (Included) EEV (Included) EEV (Included) 34.0/33.0/31.0 34.0/33.0/31.0 36.0/35.0/34.0 Net Weight lbs. 33.1 33.1 33.1 Shipping Weight lbs. 40.8 40.8 40.8 Net Dimensions (WxHxD) inches 33 x 8 x 33 33 x 8 x 33 33 x 8 x 33 Shipping Dimensions (WxHxD) inches 35 3/8 x 10 7/8 x 35 3/8 35 3/8 x 10 7/8 x 35 3/8 35 3/8 x 10 7/8 x 35 3/8 - TVEPANPC4NUSET TVEPANPC4NUSET TVEPANPC4NUSET lbs. 12.8 12.8 12.8 Shipping Weight lbs. 18.5 18.5 18.5 Net Dimensions (WxHxD) inches 37 7/16 x 1 3/4 x 37 7/16 37 7/16 x 1 3/4 x 37 7/16 37 7/16 x 1 3/4 x 37 7/16 Shipping Dimensions (WxHxD) inches 39 9/16 x 4 x 39 9/16 39 9/16 x 4 x 39 9/16 39 9/16 x 4 x 39 9/16 - Built-in Built-in Built-in Max. Lifting Height inches 29.5 29.5 29.5 Displacement Gal/Hr. 6.25 6.25 6.25 - Washable Filter Washable Filter Washable Filter Model Name Drain Pump Air Filter 1. 2. 3. 4. - - Net Weight Additional Features A Db(A) Sound Pressure H/M/L Model Name Cassette Panel3 W Indoor units 208~230/60/1 Liquid Pipe Sound2 4TVC0024B100NB Btu/h Motor Refrigerant 4TVC0018B100NB Cooling Power Fan 4TVC0009B100NB Nominal capacity based on 25 ft. of equivalent refrigerant piping with 0 ft. level difference. - Cooling: Indoor temperature 80°F DB, 67°F WB/Outdoor temperature 95°F DB, 75°F WB - Heating: Indoor temperature 70°F DB, 60°F WB/Outdoor temperature 47°F DB, 43°F WB Sound pressure was acquired in a dead room. Actual noise level may be different depending on installation conditions. Cassette panel must be ordered separately Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. VRF-PRC006-EN 19 3 4 way cassette Technical specifications Model Name Power Supply Performance 208~230/60/1 208~230/60/1 208~230/60/1 Capacity (Nominal)1 30,000 36,000 48,000 Heating Btu/h 34,000 40,000 54,000 Power Input (Nominal)1 Cooling 65.0 75.0 95.0 65.0 75.0 95.0 Current Input (Nominal)1 Cooling 0.50 0.56 0.75 Heating Heating Type (Qty.) Output (Each) Airflow Rate H/M/L External Static Pressure Min/Std/Max Liquid Pipe Piping Connections Gas Pipe Drain Pipe Sound2 External Dimensions Type Control Method 0.50 0.56 0.75 Turbo Fan Turbo Fan Turbo Fan W 97 x 1 97 x 1 97 x 1 Cfm 775/690/600 845/775/705 1025/950/850 In. WG - - - Ø inch 3/8 3/8 3/8 Ø inch 5/8 5/8 5/8 Ø inch VP 25 (OD 1 1/4", ID 1") VP 25 (OD 1 1/4", ID 1") VP 25 (OD 1 1/4", ID 1") - R410A R410A EEV (Included) EEV (Included) EEV (Included) 40.0/37.0/33.0 44.0/42.0/39.0 Net Weight lbs. 40.8 40.8 40.8 Shipping Weight lbs. 50.7 50.7 50.7 Net Dimensions (WxHxD) inches 33 x 11 1/4 x 33 33 x 11 1/4 x 33 33 x 11 1/4 x 33 Shipping Dimensions (WxHxD) inches 35 3/8 x 14 x 35 3/8 35 3/8 x 14 x 35 3/8 35 3/8 x 14 x 35 3/8 - TVEPANPC4NUSET TVEPANPC4NUSET TVEPANPC4NUSET lbs. 12.8 12.8 12.8 Shipping Weight lbs. 18.5 18.5 18.5 Net Dimensions (WxHxD) inches 37 7/16 x 1 3/4 x 37 7/16 37 7/16 x 1 3/4 x 37 7/16 37 7/16 x 1 3/4 x 37 7/16 Shipping Dimensions (WxHxD) inches 39 9/16 x 4 x 39 9/16 39 9/16 x 4 x 39 9/16 39 9/16 x 4 x 39 9/16 - Built-in Built-in Built-in Max. Lifting Height inches 29.5 29.5 29.5 Displacement Gal/Hr. 6.25 6.25 6.25 - Washable Filter Washable Filter Washable Filter Drain Pump Air Filter 20 - 39.0/34.0/30.0 Model Name 1. 2. 3. 4. A - Net Weight Additional Features W Db(A) Sound Pressure H/M/L Model Name Cassette Panel3 4TVC0048B100NB Btu/h Motor Refrigerant 4TVC0036B100NB Cooling Power Fan 4TVC0030B100NB Nominal capacity based on 25 ft. of equivalent refrigerant piping with 0 ft. level difference. - Cooling: Indoor temperature 80°F DB, 67°F WB/Outdoor temperature 95°F DB, 75°F WB - Heating: Indoor temperature 70°F DB, 60°F WB/Outdoor temperature 47°F DB, 43°F WB Sound pressure was acquired in a dead room. Actual noise level may be different depending on installation conditions. Cassette panel must be ordered separately Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. VRF-PRC006-EN 3-2. Dimensional drawing Unit: mm(inch) 6 890~910(35~35.8) Celling opening 950(37.4) 735(28.9) Suspension position 950(37.4) 6 Indoor units 890~910(35~35.8) Celling opening 735(28.9) Suspension position 5 55(2.2) 840(33.0) 3 1 55(2.2) 370(14.6) 346(13.6) 185(7.3) 55(2.2) 840(33.1) 55(2.2) 45(1.8) A 86(3.4) 164(6.5) 216(8.5) 96(3.8) 120(4.7) B 2 240(9.4) 270(10.6) 300(11.8) 330(13) Sub duct connection 7 4 80(3.1) 92.6(3.6) E Fresh Air Intake 80(3.1) 4(0.2)-Ø3.3(0.1) 195(7.7) No. Name 1 Liquid pipe connection Gas pipe connection Drain pipe connection Conduit for power supply & communication wiring Air inlet grille Air outlet louver Sub-Duct 2 3 4 5 6 7 Description 9MBH 18MBH 24MBH 30MBH 36MBH 48MBH Ø6.35(1/4") Flare Ø9.52(3/8") Flare Ø12.70(1/2") Flare Ø15.88(5/8") Flare VP25 (OD 32, ID 25)/VP25 (OD 1 1/4", ID 1") Description A B VRF-PRC006-EN mm(inch) mm(inch) 9/18/24 MBH 204(8.0) 253(10.0) 30/36/48 MBH 288(11.3) 337(13.3) 21 3 4 way cassette 3-3. Electrical wiring diagram 22 VRF-PRC006-EN 3-4. Sound pressure level Operation sound level Unit: dB(A) Model 4TVC0009B100NB 4TVC0018B100NB 4TVC0024B100NB 4TVC0030B100NB 4TVC0036B100NB 4TVC0048B100NB 1.5m Microphone High 34 34 36 39 40 44 Low 31 31 34 30 33 39 Indoor units  Note  These operation values were obtained in an anechoic room. Sound pressure level will vary depending on a range of factors such as the construction of the particular room where the equipment is installed.  Operation sound level may differ depending on operation and ambient conditions. NC curves (1) 4TVC0009B100NB (2) 4TVC0018B100NB HIGH NC 40 NC 35 LOW NC 30 NC 25 20 NC 20 NC 15 10 0 63 125 250 500 1000 2000 4000 8000 (4) 4TVC0030B100NB HIGH NC 40 NC 35 LOW NC 30 NC 25 20 NC 20 NC 15 10 63 125 250 500 1000 2000 4000 8000 HIGH NC 45 LOW NC 40 NC 35 30 NC 30 NC 25 20 NC 20 NC 15 10 63 125 250 500 1000 2000 4000 8000 Octave band center frequency(Hz) VRF-PRC006-EN NC 45 HIGH LOW NC 35 NC 30 NC 25 20 NC 20 NC 15 10 0 NC 40 LOW NC 35 30 NC 30 NC 25 20 NC 20 NC 15 10 63 125 250 500 1000 2000 4000 8000 60 NC 40 30 NC 45 HIGH (6) 4TVC0048B100NB 50 40 40 Octave band center frequency(Hz) 60 50 50 0 (5) 4TVC0036B100NB Sound pressure level (dB) Sound pressure level (dB) 30 NC 45 Octave band center frequency(Hz) 60 0 40 0 Octave band center frequency(Hz) 40 50 63 125 250 500 1000 2000 4000 8000 Octave band center frequency(Hz) Sound pressure level (dB) 30 NC 45 Sound pressure level (dB) 50 40 60 60 Sound pressure level (dB) Sound pressure level (dB) 60 (3) 4TVC0024B100NB 50 40 HIGH NC 45 LOW NC 40 NC 35 30 NC 30 NC 25 20 NC 20 NC 15 10 0 63 125 250 500 1000 2000 4000 8000 Octave band center frequency(Hz) 23 3 4 way cassette 3-5. Temperature and air flow distribution 4TVC0009B100NB (1) Cooling air velocity distribution  Discharge angle : YU^” O_U`›P ·0.8m/s (2.62ft/s) ·0.2m/s (0.66ft/s) ·0.9m/s (2.95ft/s) ·0.7m/s (2.30ft/s) ·0.1m/s (0.33ft/s) ·0.6m/s Y” O]U]›P (1.97ft/s) ·0.5m/s (1.64ft/s) X” OZUZ›P ·0.4m/s ·0.1m/s (1.31ft/s) (0.33ft/s) ·0.3m/s ·0.1m/s ·0.2m/s (0.33ft/s) Y” O]U]›P (0.98ft/s) (0.66ft/s) (0.98ft/s) YU\” O_UY›P ·0.3m/s X” OZUZ›P X” OZUZ›P Y” O]U]›P (2) Cooling temperature distribution  Discharge angle : ·17℃ ·23℃ (62.6℉) (73.4 ℉) YU\” O_UY›P YU^” O_U`›P ·23℃ (73.4℉) ·17.5℃ (63.5℉) ·22℃ (71.6℉) ·18℃ (64.4℉) Y” O]U]›P ·18.5℃ (65.3℉) ·22℃ (71.6℉) ·21.5℃ ·19.5℃ (70.7 ℉) ·22℃ (71.6℉) X” OZUZ›P (67.1℉) ·21℃ ·21℃ ·20.5℃ (69.8℉) (69.8℉) (68.9 ℉) ·20.5℃ (68.9℉) YU\” O_UY›P 24 Y” O]U]›P X” OZUZ›P X” OZUZ›P Y” O]U]›P YU\” O_UY›P VRF-PRC006-EN 4TVC0009B100NB  Discharge angle : (3) Heating air velocity distribution YU^” O_U`›P ·1.3m/s ·0.14m/s (4.27fit/s) ·1.1m/s (0.46fit/s) ·0.28m/s (3.61fit/s) ·1m/s (0.92fit/s) ·0.85m/s (3.28fit/s) Y” O]U]›P ·0.7m/s (2.30fit/s) ·0.14m/s ·0.57m/s Indoor units (2.79fit/s) ·0.14m/s (0.46fit/s) (0.46fit/s) (1.87fit/s) ·0.42m/s (1.38fit/s) X” OZUZ›P ·0.28m/s (0.92fit/s) ·0.14m/s (0.46fit/s) ·0.14m/s (1.31fit/s) YU\” O_UY›P Y” O]U]›P X” OZUZ›P X” OZUZ›P Y” O]U]›P (4) Heating temperature distribution YU\” O_UY›P  Discharge angle : YU^” O_U`›P ·28.5℃ (83.3℉)·29.4℃ (84.9℉) ·29.4℃ ·35.5℃ ·34.5℃ (84.9℉) (95.9℉) (94.1℉) ·33.6℃ (92.5℉) Y” O]U]›P ·32.8℃ (91.8℉) ·30℃ ·30℃ (86℉) ·32℃ ·29.4℃ (89.6℉) (84.9℉) (86℉) ·28.5℃ ·31℃ (83.3℉) (87.8℉) ·32℃ ·32℃ (89.6℉) (89.6℉) X” OZUZ›P ·27.6℃ ·26.7℃ (81.7℉) (80.1℉) YU\” O_UY›P Y” O]U]›P VRF-PRC006-EN X” OZUZ›P X” OZUZ›P Y” O]U]›P YU\” O_UY›P 25 3 4 way cassette 4TVC0018B100NB (1) Cooling air velocity distribution YU^” O_U`›P ·0.3m/s ·0.9m/s (2.95fit/s) (0.98fit/s) ·1m/s (3.98fit/s) ·0.2m/s ·0.7m/s (0.66fit/s) (2.30fit/s) ·0.6m/s Y” O]U]›P ·0.1m/s (1.97fit/s) 0.33fit/s) ·0.1m/s ·0.5m/s (0.33fit/s) (1.64fit/s) X” OZUZ›P ·0.3m/s ·0.2m/s ·0.1m/s (0.66fit/s) YU^\” ·0.1m/s (0.33fit/s) ·0.2m/s (0.66fit/s) (0.33fit/s) X” Y” (0.98fit/s) X” YU^\” Y” (2) Cooling temperature distribution YU^” O_U`›P ·17℃ ·17.5℃ (63.6℉) ·23℃ (75.2℉) ·18℃ (73.4℉) (64.4℉) ·18.5℃ (73.4℉) ·24℃ (62.6℉) ·23℃ Y” O]U]›P (65.3℉) ·22℃ ·19.5℃ (67.1℉) (71.6℉) ·22℃ (71.6℉) ·21.5℃ (70.7℉) X” OZUZ›P ·21℃ ·21℃ (69.8℉) (69.8℉) ·20.5℃ ·20.5℃ (68.9℉) (68.9℉) YU^\” 26 Y” X” X” Y” YU^\” VRF-PRC006-EN 4TVC0018B100NB  Discharge angle : (3) Heating air velocity distribution YU^” O_U`›P ·0.14m/s (0.46fit/s) ·0.14m/s (0.46fit/s) ·0.42m/s ·1.6m/s (5..25fit/s) ·0.14m/s (1.38fit/s) (0.92fit/s) ·1.1m/s (0.46fit/s) ·0.28m/s ·1.4m/s ·0.14m/s (4.59fit/s) (0.46fit/s) (3.61fit/s) Indoor units (3.28fit/s) (0.46fit/s) ·0.85m/s Y” O]U]›P ·1m/s ·0.14m/s ·0.28m/s (2.79fit/s) (0.92fit/s) ·0.28m/s (0.92fit/s) ·0.7m/s (2.30fit/s) ·0.57m/s ·0.42m/s X” (1.87fit/s) (1.38fit/s) OZUZ›P ·0.28m/s (0.92fit/s) ·0.14m/s ·0.14m/s (0.46fit/s) (0.46fit/s) YU^\” X” Y” Y” X” (4) Heating temperature distribution YU^\”  Discharge angle : YU^” O_U`›P ·40.6℃ (105.1℉) ·35.3℃ (95.5℉) ·39.8℃ (103.6℉) ·35.3℃ (95.5 ℉) Y” O]U]›P ·34.6℃ (94.3℉) ·36.8℃ (98.2℉) ·39℃ ·36.1℃ (97.0 ℉) (102.2 ℉) ·33.8℃ ·38.3℃ (92.8℉) (100.9℉) ·37.6℃ (99.7 ℉) X” OZUZ›P ·39℃ (102.2℉) ·33℃ (91.4℉) ·30.7℃ ·30℃ YU^\” (86℉)Y” VRF-PRC006-EN ·31.5℃ (87.3℉) ·32.3℃ (90.1℉) ·30.7℃ (87.3 ℉) (88.7℉) X” X” Y” ·30℃ (86 ℉) YU^\” 27 3 4 way cassette 4TVC0024B100NB (1) Cooling air velocity distribution YU^” O_U`›P ·0.9m/s (2.95fit/s) ·1m//s (3.28fit/s) Y” O]U]›P ·0.8m/s ·0.7m/s (2.30fit/s) (2.62fit/s) ·0.5m/s (1.64fit/s) X” OZUZ›P ·0.2m/s ·0.1m/s (0.66fit/s) (0.33fit/s) ·0.1m/s (0.33fit/s) ·0.2m/s (0.66fit/s) ·0.3m/s ·0.3m/s (0.98fit/s) ZUX” Z” (0.98fit/s) X” Y” Y” X” Z” ZUX” (2) Cooling temperature distribution YU^” O_U`›P ·24℃ (75.2℉) ·17.5℃ (63.5℉) ·18.5℃ ·23℃ ·18℃ (73.4℉) (64.4℉) Y” O]U]›P (65.3℉) ·22℃ (71.6℉) ·22℃ (71.6℉) ·19℃ (66.2℉) ·21℃ (69.8℉) ·20℃ (68℉) ·21℃ ·21℃ ·20℃ (69.8℉) ZUX” Z” 28 Y” X” OZUZ›P (68℉) X” X” Y” Z” ZUX” VRF-PRC006-EN 4TVC0024B100NB  Discharge angle : (3) Heating air velocity distribution ·0.28m/s YU^” O_U`›P ·0.28m/s (0.92fit/s) (0.92fit/s) ·0.14m/s ·0.14m/s ·0.42m/s (0.46fit/s) (1.38fit/s) ·0.28m/s (0.92fit/s) ·1.3m/s (0.46fit/s) ·1.4m/s (4.59fit/s) ·1.1m/s ·0.14m/s ·0.14m/s (3.61fit/s) (0.46fit/s) Indoor units Y” O]U]›P (4.27fit/s) (0.46fit/s) ·1m/s (3.28fit/s) ·0.28m/s ·0.85m/s (0.92fit/s) (2.79fit/s) ·0.7m/s X” OZUZ›P (2.30fit/s) ·0.57m/s (1.87fit/s) ·0.42m/s (1.38fit/s) ·0.14m/s ·0.14m/s (0.46fit/s) (0.46fit/s) ZUX” Z” X” Y” Y” X” Z” (4) Heating temperature distribution ZUX”  Discharge angle : YU^” O_U`›P ·34.5℃ (94.1℉) ·41.5℃ (106.7℉) ·33.7℃ (92.7℉) ·40℃ (104℉) ·33.7℃ (92.7℉) ·34.5℃ ·42℃ (107.6℉) ·40.8℃ (94.1℉) (105.4℉) ·33.7℃ (92.7℉) ·34.5℃ (94.1℉) Y” O]U]›P ·34.5℃ (94.1℉) ·39.3℃ (102.7℉) ·33℃ ·33℃ ·35.3℃ (91.4℉) (95.5℉) ·35.3℃ (91.4℉) (95.5℉) ·38.5℃ X” OZUZ›P (101.3℉) ·32.3℃ ·32.3℃ (90.1℉) (90.1℉) ·31.6℃ ·31.6℃ (88.9℉) (88.9℉) ·30.8℃ ·30.8℃ (87.4℉) ZUX” Z” VRF-PRC006-EN Y” X” ·30℃ (87.9℉) Y” Z” ZUX” 29 3 4 way cassette 4TVC0030B100NB (1) Cooling air velocity distribution  Discharge angle : 45° 0.6m/s (1.97ft/s) Ceiling heigt 0.4m/s (1.31ft/s) 0.8m/s (2.62ft/s) 2.7m (8.9 ft) 0.4m/s (1.31ft/s) 0.6m/s (1.97ft/s) 0.2m/s (0.66ft/s) 2m (6.6 ft) 0.2m/s (0.66ft/s) 0.2m/s (0.66ft/s) 0.2m/s (0.66ft/s) 0.2m/s (0.66ft/s) 0.6m/s (1.97ft/s) 4m (13.1 ft) 3m (9.8 ft) 0.2m/s (0.66ft/s) 0.2m/s 0.2m/s (0.66ft/s) (0.66ft/s) 0.4m/s (1.31ft/s) 2m (6.6 ft) 0.2m/s (0.66ft/s) 0.6m/s (1.97ft/s) 1m (3.3 ft) 1m 0m (0 ft) (3.3 ft) Floor distance 0.2m/s (0.66ft/s) 2m (6.6 ft) 0.4m/s (1.31ft/s) Ceiling heigt  Discharge angle : 45° 22 (71.6°F) 20 (68.0°F) 4m (13.1 ft) 2m (6.6 ft) 1m (3.3 ft) 23 (73.4°F) 22 (71.6°F) 21 (69.8°F) 1m 0m (0 ft) (3.3 ft) Floor distance 2m (6.6 ft) Ceiling heigt 4m (13.1 ft) 0.6m/s (1.97ft/s) 0.4m/s (1.31ft/s) 0.2m/s (0.66ft/s) 0.2m/s (0.66ft/s) 3m (9.8 ft) 2m (6.6 ft) 2m (6.6 ft) 0.2m/s (0.66ft/s) 0.4m/s (1.31ft/s) 1m (3.3 ft) 0.2m/s (0.66ft/s) 1m 0m (0 ft) (3.3 ft) Floor distance 2m (6.6 ft) 1m (3.3 ft) Ceiling heigt 31 (87.8°F) 31 (87.8°F) 26 (78.8°F) 27 (80.6°F) 30 3m (9.8 ft) 2.7m (8.9 ft) 27 (80.6°F) 27 (80.6°F) 30 (86°F) 22 (71.6°F) 2m (6.6 ft) 1m (3.3 ft) 24 (75.2°F) 23 (73.4°F) 22 (71.6°F) 1m 0m (0 ft) (3.3 ft) Floor distance 30 (86°F) 31 (87.8°F) 30 (86°F) 26 (78.8°F) 21 (69.8°F) 4m (13.1 ft)  Discharge angle : 52° 27 (80.6°F) 31 (87.8°F) 4m (13.1 ft) 3m (9.8 ft) (4) Heating temperature distribution 30 (86°F) 2.7m (8.9 ft) 0.4m/s (1.31ft/s) 0.4m/s (1.31ft/s) 0.6m/s (1.97ft/s) 0.4m/s (1.31ft/s) 4m (13.1 ft) 3m (9.8 ft)  Discharge angle : 52° 0.2m/s (0.66ft/s) 0.4m/s (1.31ft/s) 1m (3.3 ft) 21 (69.8°F) (3) Heating air velocity distribution 0.2m/s (0.66ft/s) 2m (6.6 ft) 20 (68.0°F) 22 (71.6°F) 22 (71.6°F) 21 (69.8°F) 3m (9.8 ft) 22 (71.6°F) 2.7m (8.9 ft) 25 (77.0°F) 23 (73.4°F) 21 (69.8°F) 22 (71.6°F) 22 (71.6°F) 22 (71.6°F) 23 (73.4°F) 23 (73.4°F) 21 (69.8°F) 24 (75.2°F) 4m (13.1 ft) 3m (9.8 ft) (2) Cooling temperature distribution 22 (71.6°F) 1m (3.3 ft) 25 (77.0°F) 31 (87.8°F) 21 (69.8°F) 2m (6.6 ft) 2m (6.6 ft) 1m (3.3 ft) 21 (69.8°F) 3m (9.8 ft) 4m (13.1 ft) VRF-PRC006-EN 4TVC0036B100NB (1) Cooling air velocity distribution  Discharge angle : 45° 2.7m (8.9 ft) 1.0m/s (3.28ft/s) 0.4m/s (1.31ft/s) 0.4m/s (1.31ft/s) 1.0m/s (3.28ft/s) 2m (6.6 ft) Ceiling heigt 0.2m/s (0.66ft/s) 0.2m/s (0.66ft/s) 1.2m/s (3.94ft/s) 0.4m/s (1.31ft/s) 0.6m/s (1.97ft/s) 4m (13.1 ft) 0.2m/s (0.66ft/s) 2m (6.6 ft) 3m (9.8 ft) 0.2m/s (0.66ft/s) 0.2m/s (0.66ft/s) 1m (3.3 ft) 0.2m/s (0.66ft/s) 1m 0m (0 ft) (3.3 ft) Floor distance 0.6m/s (1.97ft/s) 0.4m/s (1.31ft/s) 2m (6.6 ft) Ceiling heigt  Discharge angle : 45° 23 (73.4°F) 22 (71.6°F) 22 (71.6°F) 22 (71.6°F) 22 (71.6°F) 2m (6.6 ft) 3m (9.8 ft) 1m (3.3 ft) 1m (3.3 ft) 22 (71.6°F) 21 (69.8°F) 21 (69.8°F) 1m 0m (0 ft) (3.3 ft) Floor distance 21 (69.8°F) 21 (69.8°F) 2m (6.6 ft) 4m (13.1 ft) 3m (9.8 ft) (3) Heating air velocity distribution  Discharge angle : 52° 0.2m/s (0.66ft/s) 0.2m/s (0.66ft/s) 0.2m/s (0.66ft/s) 0.4m/s (1.31ft/s) 0.4m/s (1.31ft/s) Ceiling heigt 2m (6.6 ft) 21 (69.8°F) 22 (71.6°F) 21 (69.8°F) 4m (13.1 ft) 2.7m (8.9 ft) 23 (73.4°F) 22 (71.6°F) 20 (68.0°F) 4m (13.1 ft) 3m (9.8 ft) (2) Cooling temperature distribution 23 (73.4°F) 1m (3.3 ft) Indoor units 0.6m/s (1.97ft/s) 0.6m/s (1.97ft/s) 1.0m/s (3.28ft/s) 0.2m/s (0.66ft/s) 0.6m/s (1.97ft/s) 0.4m/s (1.31ft/s) 1.2m/s (3.94ft/s) 1.0m/s (3.28ft/s) 2m (6.6 ft) 0.2m/s (0.66ft/s) 0.4m/s (1.31ft/s) 2.7m (8.9 ft) 0.4m/s (1.31ft/s) 0.2m/s (0.66ft/s) 0.4m/s (1.31ft/s) 1.0m/s (3.28ft/s) 1.0m/s (3.28ft/s) 0.4m/s (1.31ft/s) 1m (3.3 ft) 0.4m/s (1.31ft/s) 0.2m/s (0.66ft/s) 0.2m/s (0.66ft/s) 4m (13.1 ft) 0.2m/s (0.66ft/s) 2m (6.6 ft) 3m (9.8 ft) 1m (3.3 ft) 1m 0m (0 ft) (3.3 ft) Floor distance 2m (6.6 ft) (4) Heating temperature distribution 29 (84.2°F) 3m (9.8 ft) 4m (13.1 ft)  Discharge angle : 52° 2.7m (8.9 ft) 29 (84.2°F) 27 (80.6°F) 27 (80.6°F) 29 (84.2°F) Ceiling heigt 0.2m/s (0.66ft/s) 2m (6.6 ft) 33 (91.4°F) 29 (84.2°F) 25 (77.0°F) 4m (13.1 ft) 3m (9.8 ft) VRF-PRC006-EN 26 (78.8°F) 31 (87.8°F) 31 (87.8°F) 2m (6.6 ft) 25 (77.0°F) 1m (3.3 ft) 25 (77.0°F) 1m 0m (0 ft) (3.3 ft) Floor distance 29 (84.2°F) 25 (77.0°F) 2m (6.6 ft) 28 (82.4°F) 1m (3.3 ft) 25 (77.0°F) 3m (9.8 ft) 4m (13.1 ft) 31 3 4 way cassette 4TVC0048B100NB Cooling air velocity distribution  Discharge angle : 45° Ceiling heigt 0.6m/s (1.97ft/s) 0.8m/s (2.62ft/s) 1.4m/s (4.59ft/s) 4m (13.1 ft) 3m (9.8 ft) 0.2m/s (0.66ft/s) 0.2m/s (0.66ft/s) 2m (6.6 ft) 1m (3.3 ft) 1.2m/s (3.94ft/s) 0.2m/s (0.66ft/s) 0.2m/s (0.66ft/s) 1m 0m (0 ft) (3.3 ft) Floor distance 0.6m/s (1.97ft/s) 2m (6.6 ft) 18 (64.4°F) 17 (62.6°F) Ceiling heigt  Discharge angle : 45° 19 (66.2°F) 20 (68.0°F) 21 (69.8°F) 20 (68.0°F) 22 (71.6°F) 17 (62.6°F) 20 (68.0°F) 21 (69.8°F) 20 (68.0°F) 2m (6.6 ft) 1m (3.3 ft) 1m (3.3 ft) 20 (68.0°F) 1m 0m (0 ft) (3.3 ft) Floor distance 2m (6.6 ft)  Discharge angle : 52° Ceiling heigt 0.4m/s (1.31ft/s) 0.4m/s (1.31ft/s) 0.8m/s (2.62ft/s) 0.2m/s (0.66ft/s) 0.8m/s (2.62ft/s) 2m (6.6 ft) 1m (3.3 ft) 1m 0m (0 ft) (3.3 ft) Floor distance 2m (6.6 ft) 3m (9.8 ft) (4) Heating temperature distribution Ceiling heigt 31 (87.8°F) 31 (87.8°F) 4m (13.1 ft) 32 33 (91.4°F) 2m (6.6 ft) 31 (87.8°F) 27 (80.6°F) 29 (84.2°F) 2m (6.6 ft) 2.7m (8.9 ft) 34 (93.2°F) 34 (93.2°F) 3m (9.8 ft) 4m (13.1 ft) 31 (87.8°F) 32 (89.6°F) 34 (93.2°F) 2m (6.6 ft)  Discharge angle : 52° 29 (84.2°F) 31 (87.8°F) 2.7m (8.9 ft) 1m (3.3 ft) 0.6m/s (1.97ft/s) 0.6m/s (1.97ft/s) 0.2m/s (0.66ft/s) 0.2m/s (0.66ft/s) 3m (9.8 ft) 0.4m/s (1.31ft/s) 1.2m/s (3.94ft/s) 0.2m/s (0.66ft/s) 0.2m/s (0.66ft/s) 0.2m/s (0.66ft/s) 4m (13.1 ft) 0.4m/s (1.31ft/s) 0.2m/s (0.66ft/s) 0.2m/s (0.66ft/s) 0.4m/s (1.31ft/s) 4m (13.1 ft) 3m (9.8 ft) (3) Heating air velocity distribution 0.2m/s (0.66ft/s) 2m (6.6 ft) 19 (66.2°F) 20 (68.0°F) 20 (68.0°F) 20 (68.0°F) 3m (9.8 ft) 2.7m (8.9 ft) 20 (68.0°F) 18.0℃ 20 (68.0°F) 4m (13.1 ft) 4m (13.1 ft) 3m (9.8 ft) (2) Cooling temperature distribution 22 (71.6°F) 1m (3.3 ft) 0.8m/s (2.62ft/s) 0.2m/s (0.66ft/s) 0.2m/s (0.66ft/s) 2m (6.6 ft) 0.4m/s (1.31ft/s) 1.4m/s (4.59ft/s) 1.4m/s (4.59ft/s) 0.8m/s (2.62ft/s) 2.7m (8.9 ft) 0.2m/s (0.66ft/s) 0.6m/s (1.97ft/s) 0.4m/s (1.31ft/s) 0.2m/s (0.66ft/s) 0.4m/s (1.31ft/s) 27 (80.6°F) 27 (80.6°F) 1m (3.3 ft) 34 (93.2°F) 33 (91.4°F) 27 (80.6°F) 1m 0m (0 ft) (3.3 ft) Floor distance 2m (6.6 ft) 3m (9.8 ft) 1m (3.3 ft) 4m (13.1 ft) VRF-PRC006-EN 14 Slim duct 4-1. Specifications Technical specifications Model Name Power Supply Performance Sound2 External Dimensions 208~230/60/1 208~230/60/1 208~230/60/1 208~230/60/1 Capacity (Nominal)1 7,500 9,500 12,000 18,000 Heating Btu/h 8,500 10,500 13,500 20,000 Power Input (Nominal)1 Cooling 47.0 60.0 75.0 140.0 47.0 60.0 75.0 140.0 Current Input (Nominal)1 Cooling 0.32 0.40 0.51 0.94 Heating Heating Type (Qty.) Output (Each) A - 0.32 0.40 0.51 0.94 Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan W 40 x 1 50 x 1 60 x 1 100 x 1 282/247/212 318/282/247 353/300/247 547/495/441 in. WG 0.00/0.08/0.16 0.00/0.08/0.16 0.00/0.08/0.16 0.00/0.08/0.16 Liquid Pipe Ø inch 1/4 1/4 1/4 1/4 Gas Pipe Ø inch 1/2 1/2 1/2 1/2 Drain Pipe Ø inch VP 25 (OD 1 1/4", ID 1") VP 25 (OD 1 1/4", ID 1") VP 25 (OD 1 1/4", ID 1") VP 25 (OD 1 1/4", ID 1") - R410A R410A R410A R410A H/M/L External Static Pressure Min/Std/Max Type Control Method Sound Pressure H/M/L - EEV (Included) EEV (Included) EEV (Included) EEV (Included) dB(A) 26.0/24.0/21.0 27.0/25.0/23.0 29.0/28.0/27.0 36.0/34.0/31.0 Net Weight lbs. 54.0 54.0 54.0 66.1 Shipping Weight lbs. 62.8 62.8 62.8 76.0 Net Dimensions (WxHxD) inches Shipping Dimensions (WxHxD) inches 45 1/4 x 11 x 28 45 1/4 x 11 x 28 45 1/4 x 11 x 28 53 3/16 x 11 x 28 Drain Pump3 Air Filter 1. 2. 3. 4. W CFM Airflow Rate Model Name Additional Features 4TVL0018B100NB Indoor units Refrigerant 4TVL0012B100NB Btu/h Motor Piping Connections 4TVL0009B100NB Cooling Power Fan 4TVL0007B100NB 35 7/16 x 7 13/16 x 23 5/8 35 7/16 x 7 13/16 x 23 5/8 35 7/16 x 7 13/16 x 23 5/8 43 5/16 x 7 13/16 x 23 5/8 - CONDPUMPXVLB01 CONDPUMPXVLB01 CONDPUMPXVLB01 CONDPUMPXVLB01 Max. Lifting Height inches 29.5 29.5 29.5 29.5 Displacement Gal/Hr. 6.25 6.25 6.25 6.25 - Washable Filter Washable Filter Washable Filter Washable Filter Nominal capacity based on 25 ft. of equivalent refrigerant piping with 0 ft. level difference. - Cooling: Indoor temperature 80°F DB, 67°F WB/Outdoor temperature 95°F DB, 75°F WB - Heating: Indoor temperature 70°F DB, 60°F WB/Outdoor temperature 47°F DB, 43°F WB Sound pressure was acquired in a dead room. Actual noise level may be different depending on installation conditions. Internally installed drain pump must be ordered separately Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. VRF-PRC006-EN 33 4 Slim duct Technical specifications Model Name Power Supply Performance Refrigerant Sound2 External Dimensions 208~230/60/1 208~230/60/1 208~230/60/1 Capacity (Nominal)1 24,000 30,000 36,000 48,000 Heating Btu/h 27,000 34,000 40,000 54,000 Power Input (Nominal)1 Cooling 145.0 95.0 120.0 180.0 145.0 95.0 120.0 180.0 Current Input (Nominal)1 Cooling 0.98 0.80 1.05 1.40 Heating Heating Type (Qty.) Output (Each) 34 W A - 0.98 0.80 1.05 1.40 Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan W 110 x 1 80 x 1 100 x 1 160 x 1 CFM 582/530/477 880/810/705 950/880/810 1,235/1,165/1,060 in. WG 0.00/0.08/0.16 0.00/0.14/0.28 0.00/0.14/0.28 0.00/0.14/0.28 Liquid Pipe Ø inch 3/8 3/8 3/8 3/8 Gas Pipe Ø inch 5/8 5/8 5/8 5/8 Drain Pipe Ø inch VP 25 (OD 1 1/4", ID 1") VP 25 (OD 1 1/4", ID 1") VP 25 (OD 1 1/4", ID 1") VP 25 (OD 1 1/4", ID 1") Airflow Rate H/M/L External Static Pressure Min/Std/Max Type - R410A R410A R410A R410A Control Method - EEV (Included) EEV (Included) EEV (Included) EEV (Included) dB(A) 38.0/36.0/33.0 37.0/36.0/34.0 37.0/36.0/34.0 39.0/38.0/36.0 Net Weight lbs. 66.1 88.2 88.2 91.5 Shipping Weight lbs. 76.0 103.6 103.6 107.0 Sound Pressure H/M/L Net Dimensions (WxHxD) inches Shipping Dimensions (WxHxD) inches 53 3/16 x 11 x 28 62 x 14 9/16 x 32 7/8 62 x 14 9/16 x 32 7/8 62 x 14 9/16 x 32 7/8 Drain Pump3 Air Filter 1. 2. 3. 4. 4TVL0048B100NB 208~230/60/1 Model Name Additional Features 4TVL0036B100NB Btu/h Motor Piping Connections 4TVL0030B100NB Cooling Power Fan 4TVL0024B100NB 43 5/16 x 7 13/16 x 23 5/8 51 3/16 x 11 5/8 x 27 3/16 51 3/16 x 11 5/8 x 27 3/16 51 3/16 x 11 5/8 x 27 3/16 - CONDPUMPXVLB01 CONDPUMPXVLB01 CONDPUMPXVLB01 CONDPUMPXVLB01 Max. Lifting Height inches 29.5 29.5 29.5 29.5 Displacement Gal/Hr. 6.25 6.25 6.25 6.25 - Washable Filter Washable Filter Washable Filter Washable Filter Nominal capacity based on 25 ft. of equivalent refrigerant piping with 0 ft. level difference. - Cooling: Indoor temperature 80°F DB, 67°F WB/Outdoor temperature 95°F DB, 75°F WB - Heating: Indoor temperature 70°F DB, 60°F WB/Outdoor temperature 47°F DB, 43°F WB Sound pressure was acquired in a dead room. Actual noise level may be different depending on installation conditions. Internally installed drain pump must be ordered separately Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. VRF-PRC006-EN 4-2. Dimensional drawing 71(2-3/4) 100(4) 10(3/8) 4TVL0007B1-TVL0012B100NB 12(4/8) Unit : mm(inch) 3x256(10-1/8)=768(30-1/4) Suction 938(36-7/8) Indoor units 7 6 600(23-5/8) 600(23-5/8) 477(18-3/4) 900(35-3/8) Suspension bolts(M8~M10) X 4EA 8x100(3-7/8)=800(31-1/2) 860(33-7/8) Duct flange connection bolts(M4) X 22EA 8 No. Name 1 Liquid pipe connection Gas pipe connection Drain pipe connection without optional drain pump kits Drain pipe connection with optional drain pump kits Control unit Conduit for power supply & communication wiring Return air side Air outlet duct flange 2 3 4 5 6 7 8 VRF-PRC006-EN 2 182(7-1/8) 246(9-5/8) 333(13-1/8) 4 73(2-7/8) 55(2-1/8) 1 199(7-7/8) 152(6) 100(4) 146(5-3/4) 32(1-1/4) 116(4-5/8) OD31(1-1/4) 18(3/4) Discharge 3 5 Description 7.5 MBH 9.5 MBH 12.0 MBH Ø6.35(1/4") Flare Ø12.70(1/2") Flare VP25 (OD 32, ID 25) / VP25 (OD 1 1/4", ID 1") VP25 (OD 32, ID 25) / VP25 (OD 1 1/4", ID 1") - 35 4 Slim duct 71(2-3/4) 100(4) 10(3/8) 4TVL0018B1-TVL0024B100NB 13(1/2) Unit : mm(inch) 3x322(12-5/8)=966(38) Suction 6 1100(43-1/4) 600(23-5/8) 600(23-5/8) 505(19-7/8) 7 Suspension bolts(M8~M10) X 4EA Duct flange connection bolts(M4) X 26EA No. Name 1 Liquid pipe connection Gas pipe connection Drain pipe connection without optional drain pump kits Drain pipe connection with optional drain pump kits Control unit Conduit for power supply & communication wiring Return air side Air outlet duct flange 2 3 4 5 6 7 8 36 199(7-7/8) OD32(1-1/4) 31(1-1/4) 116(4-5/8) 146(5-3/4) 18(3/4) Discharge 1 2 4 182(7-1/8) 246(9-5/8) 333(13-1/8) 73(2-7/8) 55(2-1/8) 1060(41-3/4) 152(6) 100(4) 10x100(3-7/8)=1000(39-3/8) 8 3 5 Description 18.0 MBH 24.0 MBH Ø6.35(1/4") Flare Ø9.52(3/8") Flare Ø12.70(1/2") Flare Ø15.88(5/8") Flare VP25 (OD 32, ID 25) / VP25 (OD 1 1/4", ID 1") VP25 (OD 32, ID 25) / VP25 (OD 1 1/4", ID 1") - VRF-PRC006-EN 16(5/8) Unit : mm(inch) 4x290(11-3/8)=1160(45-5/8) Suction Indoor units 2(1/16)x 88(3-1/2)= 83(3-1/4) 176(6-7/8) 10(3/8) 4TVL0030B1-TVL0048B100NB 6 1338(52-5/8) 1300(51-1/8) 600(23-5/8) 477(18-3/4) 690(27-1/8) 7 Suspenslon bolts(M8~M10) X 4EA 12x100(4)=1200(47-1/4) 1260(49-5/8) Duct flange connection bolts(M4) X 32EA No. Name 1 Liquid pipe connection Gas pipe connection Drain pipe connection without optional drain pump kits Drain pipe connection with optional drain pump kits Control unit Conduit for power supply & communication wiring Return air side Air outlet duct flange 2 3 4 5 6 7 8 VRF-PRC006-EN 1 2 4 182(7-1/8) 246(9-5/8) 333(13-1/8) 3 73(2-7/8) 55(2-1/8) 146(5-3/4) 116(4-5/8) OD32(1-1/4) 29(1-1/8) Discharge 295(11-5/8) 248(9-3/4) 18(3/4) 2(1/16)x100(4)=200(7-7/8) 8 5 Description 30.0 MBH 36.0 MBH 48.0 MBH Ø9.52(3/8") Flare Ø15.88(5/8") Flare VP25 (OD 32, ID 25) / VP25 (OD 1 1/4", ID 1") VP25 (OD 32, ID 25) / VP25 (OD 1 1/4", ID 1") - 37 4 Slim duct 4-3. Electrical wiring diagram 4TVL0007B1-TVL0024B100NB 38 VRF-PRC006-EN 4TVL0030B1-TVL0048B100NB Indoor units VRF-PRC006-EN 39 4 Slim duct 4-4. Sound pressure level Operation sound level Unit : dB(A) Model 4TVL0007B100NB 4TVL0009B100NB 4TVL0012B100NB 4TVL0018B100NB High Low 26 27 29 36 21 23 27 31 Model 4TVL0024B100NB 4TVL0030B100NB 4TVL0036B100NB 4TVL0048B100NB High Low 38 37 37 39 33 34 34 36  Note  These operation values were obtained in an anechoic room. Sound pressure level will vary depending on a range of factors such as the construction of the particular room where the equipment is installed.  Operation sound level may differ depending on operation and ambient conditions. 2) NC curves (1) 4TVL0007B100NB (2) 4TVL0009B100NB 45 45 NC 45 35 HIGH 30 LOW NC 40 NC 35 NC 30 25 20 NC 25 15 NC 20 10 NC 15 5 0 NC 45 40 Sound pressure level (dB) Sound pressure level (dB) 40 35 30 NC 40 HIGH NC 35 LOW NC 30 25 20 NC 25 15 NC 20 10 NC 15 5 63 125 250 500 1000 2000 4000 0 8000 63 125 Octave band center frequency(Hz) (3) 4TVL0012B100NB 2000 4000 8000 NC 40 NC 35 LOW NC 30 25 20 NC 25 15 NC 20 10 NC 15 NC 45 40 Sound pressure level (dB) Sound pressure level (dB) HIGH 35 5 35 HIGH NC 40 LOW NC 35 30 NC 30 25 20 NC 25 15 NC 20 10 NC 15 5 63 125 250 500 1000 2000 4000 Octave band center frequency(Hz) 40 1000 45 NC 45 40 0 500 (4) 4TVL0018B100NB 45 30 250 Octave band center frequency(Hz) 8000 0 63 125 250 500 1000 2000 4000 8000 Octave band center frequency(Hz) VRF-PRC006-EN NC curves (5) 4TVL0024B100NB (6) 4TVL0030B100NB 45 45 NC 45 NC 40 HIGH NC 35 30 LOW NC 30 25 20 NC 25 15 NC 20 10 NC 15 Sound pressure level (dB) 35 5 0 NC 45 40 35 30 NC 40 HIGH NC 35 LOW NC 30 25 20 NC 25 15 NC 20 10 NC 15 5 63 125 250 500 1000 2000 4000 0 8000 63 Octave band center frequency(Hz) NC 40 1000 2000 4000 8000 HIGH NC 35 LOW NC 30 25 20 NC 25 15 NC 20 10 NC 15 5 NC 45 40 Sound pressure level (dB) Sound pressure level (dB) 500 45 NC 45 40 0 250 (8) 4TVL0048B100NB 45 30 125 Octave band center frequency(Hz) (7) 4TVL0036B100NB 35 Indoor units Sound pressure level (dB) 40 HIGH NC 40 LOW NC 35 35 30 NC 30 25 20 NC 25 15 NC 20 10 NC 15 5 63 125 250 500 1000 2000 4000 Octave band center frequency(Hz) VRF-PRC006-EN 8000 0 63 125 250 500 1000 2000 4000 8000 Octave band center frequency(Hz) 41 4 Slim duct 4-5. Recommended operation range  Adjust option code according to the actual installation condition (external static pressure). (3) 4TVL0012B100NB 4.0 0.16 34.3 3.5 0.14 34.3 3.5 0.14 34.3 3.5 0.14 29.4 3.0 0.12 29.4 3.0 0.12 29.4 3.0 0.12 2.5 0.10 2.5 0.10 2.5 0.10 2.0 0.08 2.0 0.08 2.0 0.08 24.5 19.6 14.7 9.8 1.0 4.9 0.5 0 0.06 1.5 0 4 (141) L(6.0) 5 (177) 6 (212) H(8.0) 7 (247) 8 (282) 24.5 19.6 14.7 0.04 9.8 1.0 0.02 4.9 0.5 0 9 (318) 0 0.06 1.5 0 5 (177) L(7.0) 6 (212) Air Flow Rate : CMM(CFM) H(9.0) 7 (247) 8 (282) 9 (318) 24.5 19.6 14.7 External Static Pressure (mmAq) 39.2 External Static Pressure (Pa) 0.16 External Static Pressure (inH2O) 4.0 External Static Pressure (mmAq) 39.2 External Static Pressure (Pa) 0.16 External Static Pressure (inH2O) 4.0 0.04 9.8 1.0 0.02 4.9 0.5 0 10 (353) 0 0.06 1.5 0 6 (212) L(7.0) H(10.0) External Static Pressure (inH2O) (2) 4TVL0009B100NB 39.2 External Static Pressure (mmAq) External Static Pressure (Pa) (1) 4TVL0007B100NB 0.04 0.02 7 (247) Air Flow Rate : CMM(CFM) 8 (282) 9 (318) 0 11 (388) 10 (353) Air Flow Rate : CMM(CFM) External Static Pressure (in H20) Option code External Static Pressure (in H20) Option code External Static Pressure (in H20) Option code 0.00 0.04 0.08 0.16 010054-1254AE-201616-331110 010054-1255D1-201616-331110 010054-1255D1-201616-331110 010054-125904-201616-331110 0.00 0.04 0.08 0.16 010054-121913-201C1C-331110 010054-121946-201C1C-331110 010054-121946-201C1C-331110 010054-121979-201C1C-331110 0.00 0.04 0.08 0.16 010054-121946-202323-331110 010054-121979-202323-331110 010054-121979-202323-331110 010054-1219AC-202323-331110 34.3 3.5 0.14 34.3 3.5 0.14 29.4 3.0 0.12 29.4 3.0 0.12 2.5 0.10 2.5 0.10 2.0 0.08 2.0 0.08 1.5 0.06 1.5 0.06 24.5 19.6 14.7 9.8 1.0 4.9 0.5 0 0 11.5 (406) L(12.5) 12.5 (441) H(15.5) 13.5 (477) 14.5 (512) 15.5 (547) 24.5 19.6 14.7 0.04 9.8 1.0 0.02 4.9 0.5 0 16.5 (582) 0 0 12 (424) L(13.5) H(16.5) 0.04 0.02 13 (459) Air Flow Rate : CMM(CFM) 14 (494) 15 (530) 16 (565) 17 (600) 0 18 (635) 68.6 7.0 0.28 58.8 6.0 0.24 49.0 5.0 0.20 4.0 0.16 3.0 0.12 2.0 0.08 39.2 29.4 19.6 9.8 0 1.0 L(23) 0 19.8 21.4 (699) (755) H(31) 23 (812) 24.6 (868) 26.2 (925) External Static Pressure (inH2O) 0.16 External Static Pressure (mmAq) 4.0 External Static Pressure (mmAq) 39.2 External Static Pressure (Pa) 0.16 External Static Pressure (inH2O) 4.0 External Static Pressure (Pa) (6) 4TVL0030B100NB External Static Pressure (inH2O) (5) 4TVL0024B100NB 39.2 External Static Pressure (mmAq) External Static Pressure (Pa) (4) 4TVL0018B100NB 0.04 0 27.8 29.4 31 32.6 (981) (1038) (1094) (1151) Air Flow Rate : CMM(CFM) Air Flow Rate : CMM(CFM) External Static Pressure (in H20) Option code External Static Pressure (in H20) Option code External Static Pressure (in H20) Option code 0.00 0.04 0.08 0.16 010054-1259BA-203434-331110 010054-1259ED-203434-331110 010054-1259ED-203434-331110 010054-125E10-203434-331110 0.00 0.04 0.08 0.16 010054-125D2D-204848-331110 010054-125E50-204848-331110 010054-125E50-204848-331110 010054-125E83-204848-331110 0.00 0.04 0.12 0.24 010054-1B5915-205A5A-331110 010054-1B5948-205A5A-331110 010054-1B599F-205A5A-331110 010054-1B5AE4-205A5A-331110  Note  ESP = External Static Pressure  The graphs display the available external static pressure range of installed indoor units. Therefore, they do not reflect the actual change of external static pressure and airflow rate according to adjusted airflow (High-Mid-Low) of installed indoor units. 42 VRF-PRC006-EN  Adjust option code according to the actual installation condition (external static pressure). 7.0 0.28 58.8 6.0 0.24 58.8 6.0 0.24 49.0 5.0 0.20 49.0 5.0 0.20 4.0 0.16 4.0 0.16 39.2 29.4 19.6 9.8 0 3.0 L(24) H(34) 0.12 39.2 29.4 2.0 0.08 19.6 1.0 0.04 9.8 0 20 (706) 22.5 (794) 24 (847) 26.5 (935) 29 (1024) 31.5 (1112) 0 34 36.5 (1200) (1288) 0 External Static Pressure (mmAq) 68.6 External Static Pressure (Pa) 0.28 External Static Pressure (inH2O) 7.0 External Static Pressure (mmAq) 68.6 3.0 L(27) H(38) 0.12 2.0 0.08 1.0 0.04 0 25.8 (911) 27 (953) 29.2 (1031) 31.4 (1108) 33.6 (1186) External Static Pressure (inH2O) (8) 4TVL0048B100NB Indoor units External Static Pressure (Pa) (7) 4TVL0036B100NB 0 35.8 38 40.2 (1264) (1341) (1419) Air Flow Rate : CMM(CFM) Air Flow Rate : CMM(CFM) External Static Pressure (in H20) Option code External Static Pressure (in H20) Option code 0.00 0.04 0.12 0.24 010054-1B5956-206E6E-331110 010054-1B5989-206E6E-331110 010054-1B5AD0-206E6E-331110 010054-1B5E25-206E6E-331110 0.00 0.04 0.12 0.24 010054-1B59B9-209191-331110 010054-1B59EC-209191-331110 010054-1B5E33-209191-331110 010054-1B5E88-209191-331110  Note  ESP = External Static Pressure  The graphs display the available external static pressure range of installed indoor units. Therefore, they do not reflect the actual change of external static pressure and airflow rate according to adjusted airflow (High-Mid-Low) of installed indoor units. VRF-PRC006-EN 43 5 MSP (Middle static pressure) duct 5-1. Specifications Technical specifications Model Name Power Supply Performance 208~230/60/1 208~230/60/1 208~230/60/1 Capacity (Nominal)1 18,000 24,000 30,000 Heating Btu/h 20,000 27,000 34,000 Power Input (Nominal)1 Cooling 165.0 220.0 260.0 165.0 220.0 260.0 Current Input (Nominal)1 Cooling 1.40 1.50 1.50 Heating Heating Type (Qty.) Output (Each) Airflow Rate H/M/L External Static Pressure Min/Std/Max Liquid Pipe Piping Gas Pipe Connections Drain Pipe Sound2 External Dimensions Type Control Method Sound Pressure 44 A - H/M/L 1.40 1.50 1.50 Sirocco Fan Sirocco Fan Sirocco Fan W 124 x 1 124 x 1 180 x 1 CFM 512/460/406 653/600/547 882/810/706 0.00/0.16.0.31 0.00/0.16.0.31 0.24/0.31/0.39 1/4 3/8 3/8 in. WG Ø inch 1/2 5/8 5/8 Ø inch VP 25 (OD 1 1/4", ID 1") VP 25 (OD 1 1/4", ID 1") VP 25 (OD 1 1/4", ID 1") - R-410A R-410A R-410A - EEV (Included) EEV (Included) EEV (Included) dB(A) 35.0/33.0/31.0 39.0/35.0/31.0 40.0/37.0/34.0 Net Weight lbs. 63.9 63.9 80.5 Shipping Weight lbs. 72.75 72.75 89.3 Net Dimensions (WxHxD) inches 35 7/16 x 10 1/4 x 18 7/8 35 7/16 x 10 1/4 x 18 7/8 45 1/4 x 12 5/8 x 18 7/8 Shipping Dimensions (WxHxD) inches 46 1/16 x 13 3/8 x 23 7/16 46 1/16 x 13 3/8 x 23 7/16 55 15/16 x 15 3/4 x 23 7/16 Drain Pump3 Air Filter 1. 2. 3. 4. W Ø inch Model Name Additional Features 4TVD0030B100NB Btu/h Motor Refrigerant 4TVD0024B100NB Cooling Power Fan 4TVD0018B100NB - CONDPUMPXVLB01 CONDPUMPXVMB01 CONDPUMPXVMB02 Max. Lifting Height inches 29.5 29.5 29.5 Displacement Gal/Hr. 6.25 6.25 6.25 - Washable Filter Washable Filter Washable Filter Nominal capacity based on 25 ft. of equivalent refrigerant piping with 0 ft. level difference. - Cooling: Indoor temperature 80°F DB, 67°F WB/Outdoor temperature 95°F DB, 75°F WB - Heating: Indoor temperature 70°F DB, 60°F WB/Outdoor temperature 47°F DB, 43°F WB Sound pressure was acquired in a dead room. Actual noise level may be different depending on installation conditions. Internally installed drain pump must be ordered separately Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. VRF-PRC006-EN Technical specifications Model Name Power Supply Performance 208~230/60/1 Capacity (Nominal)1 36,000 48,000 Heating Btu/h 40,000 54,000 Power Input (Nominal)1 Cooling 290.0 430.0 290.0 430.0 Current Input (Nominal)1 Cooling 1.60 2.45 Heating Heating Type (Qty.) Output (Each) Airflow Rate H/M/L External Static Pressure Min/Std/Max Liquid Pipe Piping Gas Pipe Connections Drain Pipe Sound2 External Dimensions Type Control Method - 1.60 2.45 Sirocco Fan Sirocco Fan W 180 x 1 218 x 1 CFM 954/880/812 1,236/1,165/1,059 0.24/0.31/0.39 0.24/0.31/0.39 3/8 3/8 in. WG Ø inch 5/8 5/8 Ø inch VP 25 (OD 1 1/4", ID 1") VP 25 (OD 1 1/4", ID 1") - R-410A R-410A - EEV (Included) EEV (Included) dB(A) 41.0/40.0/38.0 42.0/39.0/36.0 Net Weight lbs. 80.5 107 Shipping Weight lbs. 89.3 122.4 Sound Pressure H/M/L Net Dimensions (WxHxD) inches 45 1/4 x 12 5/8 x 18 7/8 47 1/4 x 14 3/16 x 25 5/8 Shipping Dimensions (WxHxD) inches 55 15/16 x 15 3/4 x 23 7/16 57 5/16 x 17 1/8 x 30 5/8 Drain Pump3 Air Filter 1. 2. 3. 4. A Ø inch Model Name Additional Features W - CONDPUMPXVMB02 CONDPUMPXVDB01 Max. Lifting Height inches 29.5 29.5 Displacement Gal/Hr. 6.25 6.25 - Washable Filter Washable Filter Indoor units 208~230/60/1 Btu/h Motor Refrigerant 4TVD0048B100NB Cooling Power Fan 4TVD0036B100NB Nominal capacity based on 25 ft. of equivalent refrigerant piping with 0 ft. level difference. - Cooling: Indoor temperature 80°F DB, 67°F WB/Outdoor temperature 95°F DB, 75°F WB - Heating: Indoor temperature 70°F DB, 60°F WB/Outdoor temperature 47°F DB, 43°F WB Sound pressure was acquired in a dead room. Actual noise level may be different depending on installation conditions. Internally installed drain pump must be ordered separately Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. VRF-PRC006-EN 45 5 MSP (Middle static pressure) duct 5-2. Dimensional drawing 4TVD0018B1-TVD0024B100NB 77(3) 12(0.5) 117(4.6) Unit: mm(inch) Suction 6 480(18.9) 480(18.9) 397(15.6) Suspension position 7 135(5.3) x 5(0.2) = 675(26.6) 844(33.2) Air outlet duct flange 900(35.4) 936(36.9) Suspension position 8 600(23.6) Suspension bolts(M8~M10) X 4EA Duct flange connection bolts(M4) X 16EA 260(10.2) 185(7.3) 90(3.5) Discharge 2 1 4 5 No. 1 2 3 4 5 6 7 8 46 3 76(3) 132(5.2) 139(5.5) Description 18MBH 24MBH Liquid pipe connection Ø6.35(1/4") Flare Ø9.52(3/8") Flare Gas pipe connection Ø12.70(1/2") Flare Ø15.88(5/8") Flare Drain pipe connection without optional drain pump kits VP25 (OD 32, ID 25) / VP25 (OD 1 1/4", ID 1") Drain pipe connection with optional drain pump kits VP25 (OD 32, ID 25) / VP25 (OD 1 1/4", ID 1") Control unit Conduit for power supply & communication wiring Return air side Air outlet duct flange Name VRF-PRC006-EN 4TVD0030B1-TVD0036B1NB Unit: mm(inch) 1 2 Indoor units 6 7 6x135(5-3/8)=810(31-7/8) 902(35-1/2) Air outlet duct flange 1150(45-1/4) 1186(46-3/4) Suspension position 480(18-7/8) 600(23-5/8) Suspension bolts(M8~M10) X 4EA Duct flange connection bolts(M4) X 18EA 77(3) 5 3 No. Name 1 Liquid pipe connection Gas pipe connection Drain pipe connection without optional drain pump kits Drain pipe connection with optional drain pump kits Control unit Conduit for power supply & communication wiring Return air side Air outlet duct flange 2 3 4 5 6 7 8 VRF-PRC006-EN 157(6-1/8) 4 27(1-1/8) 107(4-1/4) 121(4-3/4) 320(12-5/8) 229(9) 125(4-7/8) Discharge Air outlet flange 8 87(3-3/8) 222(8-6/8) 397(15-5/8) Suspension position Suction 132(5-1/4) 144(5-5/8) Description 30.0 MBH 36.0 MBH Ø9.52(3/8") Flare Ø15.88(5/8") Flare VP25 (OD 32, ID 25) / VP25 (OD 1 1/4", ID 1") VP25 (OD 32, ID 25) / VP25 (OD 1 1/4", ID 1") - 47 5 MSP (Middle static pressure) duct 5-3. Dimensional drawing 4TVD0048B100NB Unit: mm(inch) 1 2 6 Discharge 650(25-5/8) Duct flange connection bolts(M4) X 20EA 360(14-1/8) 253(10) Air outlet flange 8 Suspension bolts(M8~M10) X 4EA 2(1/8)x100(3-7/8)=200(7-7/8) 6x150(5-7/8)=900(35-3/8) 1000(39-3/8) Air outlet duct flange 1200(47-1/4) 1236(48-5/8) Suspension position 86(3-3/8) 222(8-3/4) Suction 534(21) Suspension position 7 4 5 3 80(3-1/8) 170(6-3/4) 244(9-5/8) 299(11-3/4) No. 1 2 3 4 5 6 7 8 48 Description 48.0 MBH Liquid pipe connection Ø9.52(3/8") Flare Gas pipe connection Ø15.88(5/8") Flare Drain pipe connection without optional drain pump kits VP25 (OD 32, ID 25) / VP25 (OD 1 1/4", ID 1") Drain pipe connection with optional drain pump kits VP25 (OD 32, ID 25) / VP25 (OD 1 1/4", ID 1") Control unit Conduit for power supply & communication wiring Return air side Air outlet duct flange Name VRF-PRC006-EN 5-4. Electrical wiring diagram Indoor units VRF-PRC006-EN 49 5 MSP (Middle static pressure) duct 5-5. Sound pressure level Operation sound level Unit : dB(A) Model 4TVD0018B100NB 4TVD0024B100NB 4TVD0030B100NB 4TVD0036B100NB 4TVD0048B100NB High Low 35 39 40 41 42 31 31 34 38 36  Note  These operation values were obtained in an anechoic room. Sound pressure level will vary depending on a range of factors such as the construction of the particular room where the equipment is installed.  Operation sound level may differ depending on operation and ambient conditions. 2) NC curves (1) 4TVD0018B100NB (2) 4TVD0024B100NB 45 45 NC 45 NC 40 35 30 HIGH 25 LOW NC 35 NC 30 20 NC 25 15 NC 20 10 NC 15 5 0 NC 45 40 Sound pressure level (dB) Sound pressure level (dB) 40 35 NC 40 HIGH NC 35 30 25 NC 30 LOW 20 NC 25 15 NC 20 10 NC 15 5 63 125 250 500 1000 2000 4000 0 8000 63 Octave band center frequency(Hz) 125 250 500 1000 2000 4000 8000 Octave band center frequency(Hz) (3) 4TVD0030B100NB (4) 4TVD0036B100NB 60 60 50 50 40 NC 45 HIGH NC 40 NC 35 30 NC 30 LOW NC 25 20 NC 20 NC 15 10 0 63 125 250 500 1000 2000 4000 Octave band center frequency(Hz) 50 8000 Sound pressure level (dB) Sound pressure level (dB) HIGH LOW NC 45 40 NC 40 NC 35 30 NC 30 NC 25 20 NC 20 NC 15 10 0 63 125 250 500 1000 2000 4000 8000 Octave band center frequency(Hz) VRF-PRC006-EN (5) 4TVD0048B100NB 50 40 HIGH NC 45 LOW NC 40 NC 35 30 NC 30 Indoor units Sound pressure level (dB) 60 NC 25 20 NC 20 NC 15 10 0 63 125 250 500 1000 2000 4000 8000 Octave band center frequency(Hz) VRF-PRC006-EN 51 5 MSP (Middle static pressure) duct 5-6. Recommended operation range  Adjust option code according to the actual installation condition (external static pressure). 14.0 0.55 68.6 7.0 0.28 68.6 7.0 0.28 127.5 13.0 0.51 58.8 6.0 0.24 58.8 6.0 0.24 117.7 12.0 0.47 5.0 0.20 5.0 0.20 49.0 39.2 29.4 4.0 L(11.5) H(14.5) 0.16 3.0 0.12 19.6 2.0 0.08 9.8 1.0 0.04 0 0 10 (353) 11 (388) 12 (424) 13 (459) 14 (494) 15 (530) 0 16 (565) 49.0 39.2 29.4 4.0 L(15.5) H(18.5) 0.16 8.0 9.8 1.0 0.04 68.6 7.0 58.8 6.0 16 (565) 0 0 14 (494) 15 (530) 16 (565) 17 (600) 18 (635) 19 (671) 0 20 (706) 127.5 13.0 0.51 127.5 13.0 0.51 117.7 12.0 0.47 117.7 12.0 0.47 11.0 0.43 10.0 0.39 9.0 0.35 L(23) 22 (777) H(27) 24 (847) 26 (918) 28 (988) 107.9 98.1 88.3 11.0 0.43 10.0 0.39 9.0 0.35 0.31 78.5 8.0 0.28 68.6 7.0 0.24 30 (1059) 58.8 6.0 26 (918) L(30) 0.24 0.31 0.39 0.47 22 (777) 24 (847) 26 (918) 0.24 28 (988) 0.24 0.31 0.39 0.47 Option code 010054-1259CE-205A5A-331110 010054-125E02-205A5A-331110 010054-125E46-205A5A-331110 Option code 010054-125E00-206E6E-331110 010054-125E44-206E6E-331110 010054-125E88-206E6E-331110 H(35) 0.31 0.28 28 (988) 30 (1059) 32 (1130) 34 (1200) 36 (1271) 0.24 38 (1341) Air Flow Rate : CMM(CFM) Air Flow Rate : CMM(CFM) External Static Pressure (in H20) 20 (706) External Static Pressure (inH2O) 0.55 External Static Pressure (mmAq) 14.0 External Static Pressure (Pa) 137.3 External Static Pressure (inH2O) 0.55 External Static Pressure (mmAq) External Static Pressure (Pa) 14.0 20 (706) 18 (635) (5) 4TVD0048B100NB 137.3 6.0 18 (635) 0.31 0.28 External Static Pressure (in H20) 010054-125904-204848-331110 010054-125936-204848-331110 010054-125979-204848-331110 010054-125DF9-204848-331110 010054-125DFC-204848-331110 (4) 4TVD0036B100NB H(25) Air Flow Rate : CMM(CFM) 0.00 0.08 0.16 0.24 0.31 58.8 L(20) Air Flow Rate : CMM(CFM) 010054-125571-203434-331110 010054-125593-203434-331110 010054-1255C5-203434-331110 010054-1255F5-203434-331110 010054-125957-203434-331110 7.0 0.35 78.5 0.00 0.08 0.16 0.24 0.31 68.6 9.0 0.08 Option code 8.0 0.39 2.0 External Static Pressure (in H20) 78.5 10.0 19.6 Option code 88.3 88.3 0.43 0.12 External Static Pressure (in H20) 98.1 98.1 11.0 3.0 Air Flow Rate : CMM(CFM) 107.9 107.9 External Static Pressure (mmAq) 137.3 External Static Pressure (Pa) 0.31 External Static Pressure (inH2O) 8.0 External Static Pressure (mmAq) 78.5 External Static Pressure (Pa) 0.31 External Static Pressure (inH2O) 8.0 External Static Pressure (inH2O) (3) 4TVD0030B100NB (2) 4TVD0024B100NB 78.5 External Static Pressure (mmAq) External Static Pressure (Pa) (1) 4TVD0018B100NB External Static Pressure (in H20) 0.24 0.31 0.39 0.47 Option code 010054-125E20-209191-331110 010054-125E43-209191-331110 010054-125E86-209191-331110  Note  ESP = External Static Pressure  The graphs display the available external static pressure range of installed indoor units. Therefore, they do not reflect the actual change of external static pressure and airflow rate according to adjusted airflow (High-Mid-Low) of installed indoor units. 52 VRF-PRC006-EN 16 HSP (High static pressure) duct 6-1. Specifications Technical specifications Model Name Power Supply Performance Power Refrigerant Sound2 208~230/60/1 208~230/60/1 208~230/60/1 208~230/60/1 Capacity (Nominal)1 36,000 48,000 76,800 96,000 Heating Btu/h 40,000 54,000 85,200 108,000 Power Input (Nominal)1 Cooling 210.0 330.0 530.0 790.0 210.0 330.0 530.0 790.0 1.47 1.47 3.80 5.90 Heating Current Input Cooling (Nominal)1 Heating Airflow Rate Type (Qty.) Output (Each) H/M/L A - 1.47 1.47 3.80 5.90 Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan W 183 x 2 183 x 2 400 x 1 400 x 1 CFM 989/880/777 1,377/1,183/989 2,048/1,835/1,660 2,543/2,295/2,047 0.20/0.39/0.79 0.20/0.39/0.79 0.20/0.59/0.98 0.20/0.59/1.10 3/8 3/8 3/8 3/8 in. WG Liquid Pipe Ø inch Gas Pipe Ø inch 5/8 5/8 3/4 7/8 Drain Pipe Ø inch VP 25 (OD 1 1/4", ID 1") VP 25 (OD 1 1/4", ID 1") VP 25 (OD 1 1/4", ID 1") VP 25 (OD 1 1/4", ID 1") Type - R-410A R-410A R-410A R-410A Control Method - EEV (Included) EEV (Included) EEV (Included) EEV (Included) 40.0/39.0/37.0 44.0/42.0/40.0 45.0/43.0/41.0 48.0/46.0/43.0 123.5 123.5 196.2 196.2 218.3 218.3 Sound Pressure H/M/L dB(A) lbs. Shipping Weight lbs. 138.9 138.9 Net Dimensions (WxHxD) inches 47 1/4 x 14 3/16 x 25 5/8 47 1/4 x 14 3/16 x 25 5/8 Shipping Dimensions (WxHxD) inches 58 1/4 x 16 9/16 x 31 1/8 58 1/4 x 16 9/16 x 31 1/8 59 5/16 x 22 x 45 1/2 59 5/16 x 22 x 45 1/2 CONDPUMPXVDB01 CONDPUMPXVDB01 CONDPUMPXVHB01 CONDPUMPXVHB01 29.5 29.5 29.5 29.5 Max. Lifting Drain Pump3 Height Displacement Air Filter 1. 2. 3. 4. W External Static Min/Std/Max Pressure Model Name Additional Features 4TVA0096B100NB Btu/h Net Weight External Dimensions 4TVA0076B100NB inches Indoor units Piping Connections 4TVA0048B100NB Cooling Motor Fan 4TVA0036B100NB 48 13/16 x 18 1/2 x 40 15/16 48 13/16 x 18 1/2 x 40 15/16 Gal/Hr. 6.25 6.25 6.25 6.25 - Washable Filter Washable Filter Washable Filter Washable Filter Nominal capacity based on 25 ft. of equivalent refrigerant piping with 0 ft. level difference. - Cooling: Indoor temperature 80°F DB, 67°F WB/Outdoor temperature 95°F DB, 75°F WB - Heating: Indoor temperature 70°F DB, 60°F WB/Outdoor temperature 47°F DB, 43°F WB Sound pressure was acquired in a dead room. Actual noise level may be different depending on installation conditions. Internally installed drain pump must be ordered separately Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. VRF-PRC006-EN 53 6 HSP (High static pressure) duct 6-2. Dimensional drawing 4TVA0036B1-TVA0048B100NB Unit : mm(inch) 1 2 6 Discharge 650(25-5/8) Duct flange connection bolts(M4) X 20EA 360(14-1/8) 253(10) Air outlet flange 8 Suspension bolts(M8~M10) X 4EA 2(1/8)x100(3-7/8)=200(7-7/8) 6x150(5-7/8)=900(35-3/8) 1000(39-3/8) Air outlet duct flange 1200(47-1/4) 1236(48-5/8) Suspension position 86(3-3/8) 222(8-3/4) Suction 534(21) Suspension position 7 4 5 3 80(3-1/8) 170(6-3/4) 244(9-5/8) 299(11-3/4) No. 1 2 3 4 5 6 7 8 54 Description 36.0 / 48.0 MBH Liquid pipe connection Ø9.52(3/8") Flare Gas pipe connection Ø15.88(5/8") Flare Drain pipe connection without optional drain pump kits VP25 (OD 32, ID 25) / VP25 (OD 1 1/4", ID 1") Drain pipe connection with optional drain pump kits VP25 (OD 32, ID 25) / VP25 (OD 1 1/4", ID 1") Control unit Conduit for power supply & communication wiring Return air side Air outlet duct flange Name VRF-PRC006-EN 4TVA0076B1-TVA0096B100NB 7 1306(51.4) Suspension position 1040(40.9) Indoor units 1188(46.8) Air intlet duct flange 140(5.5) x 8(0.3) = 1120(44.1) 914(36) Suspension position 8 Unit : mm(inch) 6 34(1.3) 80(3.1) 1240(48.8) 385(15.2) 100(3.9) x 2(0.1) = 200(7.9) 93(3.7) 22(0.9) 29(1.1) 470(18.5) OD Ø32(1.3) 35(1.4) 660(26) 647(25.5) 598(23.5) 209(8.2) 236(9.3) 140(5.5) x 8(0.3) = 1120(44.1) 1188(46.8) Air outlet duct flange Discharge side 5 No. 1 Name Liquid pipe connection 2 Gas pipe connection 3 Drain pipe connection without optional drain pump kits Drain pipe connection with optional drain pump kits Power supply/Communication connection Air discharge grille flange Suction flange Hook 4 5 6 7 8 VRF-PRC006-EN Suction side 1 2 3 4 Description Ø9.52 (3/8”) 76.0 MBH : Ø19.05 (3/4”) 96.0 MBH : Ø22.22 (7/8”) VP25 (OD 32, ID 25) VP25 (OD 32, ID 25) 3/8” or M10 55 6 HSP (High static pressure) duct 6-3. Electrical wiring diagram 4TVA0036-0096B100NB 56 VRF-PRC006-EN 6-4. Sound pressure level Operation sound level Unit : dB(A) Model 4TVA0036B100NB 4TVA0048B100NB 4TVA0076B100NB 4TVA0096B100NB High Low 40 44 45 48 37 40 41 43 Indoor units  Note  These operation values were obtained in an anechoic room. Sound pressure level will vary depending on a range of factors such as the construction of the particular room where the equipment is installed.  Operation sound level may differ depending on operation and ambient conditions. NC curves (1) 4TVA0036B100NB (2) 4TVA0048B100NB 60 60 HIGH 50 LOW NC 45 40 NC 40 NC 35 30 NC 30 NC 25 20 NC 20 NC 15 10 0 63 125 250 500 1000 2000 4000 Sound pressure level (dB) Sound pressure level (dB) HIGH 50 NC 45 40 NC 40 NC 35 30 NC 30 NC 25 20 NC 20 NC 15 10 0 8000 LOW 63 Octave band center frequency(Hz) 80 80 70 NC 70 HIGH NC 60 LOW NC 50 40 NC 40 30 NC 30 20 NC 20 10 Sound pressure level (dB) Sound pressure level (dB) 90 0 500 1000 2000 4000 8000 (4) 4TVA0096B100NB 90 50 250 Octave band center frequency(Hz) (3) 4TVA0076B100NB 60 125 70 NC 70 HIGH 60 NC 60 LOW 50 NC 50 40 NC 40 30 NC 30 20 NC 20 10 63 125 250 500 1000 2000 4000 Octave band center frequency(Hz) VRF-PRC006-EN 8000 0 63 125 250 500 1000 2000 4000 8000 Octave band center frequency(Hz) 57 6 HSP (High static pressure) duct 6-5. Recommended operation range  Adjust option code according to the actual installation condition (external static pressure). 15.0 0.59 147.1 15.0 0.59 98.0 10.0 L(22) H(28) 5.0 49.0 0.40 0.20 98.0 49.0 10.0 L(28) H(39) 5.0 0.40 30.0 1.18 245.2 25.0 0.98 196.1 147.1 98.0 0 19 (671) 21 (741) 23 (812) 25 (883) 27 (953) 0 29 31 33 (1024) (1094) (1165) 0 0 0 24 26 28 30 32 34 36 38 40 42 44 (847) (918) (988) (1059) (1130) (1200) (1271) (1341) (1412) (1483) (1553) Air Flow Rate : CMM(CFM) 15.0 L(47) H(58) 0.59 10.0 0.40 5.0 0.20 0.20 49.0 0 0.79 20.0 External Static Pressure (inH2O) 147.1 294.2 External Static Pressure (mmAq) 0.79 External Static Pressure (mmAq) 20.0 External Static Pressure (Pa) 196.1 External Static Pressure (inH2O) 0.79 External Static Pressure (Pa) (3) 4TVA0076B100NB 20.0 External Static Pressure (inH2O) (2) 4TVA0048B100NB 196.1 External Static Pressure (mmAq) External Static Pressure (Pa) (1) 4TVA0036B100NB 0 0 0 44 46 48 50 52 54 56 58 60 62 64 (1553)(1624) (1694) (1765) (1836) (1906) (1977) (2047) (2118) (2189) (2259) Air Flow Rate : CMM(CFM) External Static Pressure (in H20) Option code External Static Pressure (in H20) Option code 0.20 0.40 0.59 0.79 010054-1355C6-206E6E-331110 010054-1355C6-206E6E-331110 010054-13596E-206E6E-331110 010054-135AE4-206E6E-331110 0.20 0.40 0.59 0.79 010054-135926-209191-331110 010054-135999-209191-331110 010054-135E23-209191-331110 010054-135E9A-209191-331110 Air Flow Rate : CMM(CFM) External Static Pressure (in H20) Option code 0.20 0.40 0.59 0.79 0.98 011054-195097-20DCDC-331110 011054-1950C7-20DCDC-331110 011054-1950E8-20DCDC-331110 011054-19544D-20DCDC-331110 011054-19549F-20DCDC-331110 30.0 1.18 274.6 28.0 1.10 245.2 25.0 0.98 196.1 147.1 98.0 49.0 0 0.79 20.0 15.0 L(58) H(72) 0.59 10.0 0.40 5.0 0.20 External Static Pressure (inH2O) 294.2 External Static Pressure (mmAq) External Static Pressure (Pa) (4) 4TVA0096B100NB 0 0 50 54 58 62 66 70 74 76 80 (1765) (1906) (2047) (2189) (2330) (2471) (2612) (2683) (2824) Air Flow Rate : CMM(CFM) External Static Pressure (in H20) Option code 0.20 0.40 0.59 0.79 0.98 1.10 011054-195407-231C1C-331110 011054-195429-231C1C-331110 011054-19545B-231C1C-331110 011054-19549E-231C1C-331110 011054-1955D1-231C1C-331110 011054-1955F3-231C1C-331110  Note  ESP = External Static Pressure  The graphs display the available external static pressure range of installed indoor units. Therefore, they do not reflect the actual change of external static pressure and airflow rate according to adjusted airflow (High-Mid-Low) of installed indoor units. 58 VRF-PRC006-EN 17 Ceiling Suspended (Floor) 7-1. Specifications Technical specifications Model Name Power Supply Performance 208~230/60/1 Capacity (Nominal)1 18,000 24,000 Heating Btu/h 20,000 27,000 Power Input (Nominal)1 Cooling 72.0 80.0 72.0 80.0 Current Input (Nominal)1 Cooling 0.42 0.48 Heating Heating Type (Qty.) Output (Each) Airflow Rate H/M/L External Static Pressure Min/Std/Max Liquid Pipe Refrigerant Sound2 Additional Features A - 0.42 0.48 Sirocco Fan Sirocco Fan W 25 x 1 35 x 1 Cfm 495/460/420 635/580/530 In. Wg - - Ø inch 1/4 3/8 Gas Pipe Ø inch 1/2 5/8 Drain Pipe Ø in (mm) ID 11/16" hose ID 11/16" hose Type - R-410A R-410A Control Method3 - EEV (not included) EEV (not included) Db(A) 40.0/37.0/34.0 44.0/42.0/40.0 lbs. 46.3 46.3 Sound Pressure Net Weight External Dimensions W Shipping Weight H/M/L lbs. 56.2 56.2 Net Dimensions (WxHxD) inches 39 3/8 x 25 1/2 x 7 7/8 39 3/8 x 25 1/2 x 7 7/8 Shipping Dimensions (WxHxD) inches 42 1/2 x 28 3/4 x 11 13/16 42 1/2 x 28 3/4 x 11 13/16 - Washable Filter Washable Filter Air Filter Indoor units 208~230/60/1 Btu/h Motor Piping Connections 4TVX0024B100NB Cooling Power Fan 4TVX0018B100NB 1. Nominal capacity based on 25 ft. of equivalent refrigerant piping with 0 ft. level difference. - Cooling: Indoor temperature 80°F DB, 67°F WB/Outdoor temperature 95°F DB, 75°F WB - Heating: Indoor temperature 70°F DB, 60°F WB/Outdoor temperature 47°F DB, 43°F WB 2. Sound pressure was acquired in a dead room. Actual noise level may be different depending on installation conditions. 3. EEV kit to be ordered separately, see application guide on page 74. 4. Condensate pump, if necessary, to be field supplied 5. Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. VRF-PRC006-EN 59 7 Ceiling Suspended (Floor) 7-2. Dimensional drawing Unit: mm(inch) 6 253(10) 650(25.6) 1000(39.4) 868(34.2) 200(7.9) 5 4 11(0.4) 240(9.4) Suspension position 3 Ø22(0 197(7.8) .9) 2 39(1.5) No. 922(36.3) Suspension position Name Description 18.0 MBH 24.0 MBH 1 Liquid pipe connection Ø6.35(1/4") Flare 2 Gas pipe connection Drain pipe connection Conduit for power supply & communication wiring Air inlet grille Air outlet louver Ø12.70(1/2") Flare Ø15.88(5/8") Flare ID18 Hose/ID11/16" Hose 3 4 5 6 60 1 Ø9.52(3/8") Flare - VRF-PRC006-EN 7-3. Electrical wiring diagram Indoor units VRF-PRC006-EN 61 7 Ceiling Suspended (Floor) 7-4. Sound pressure level Operation sound level Unit : dB(A) 1m 1m Model High Low 4TVX0018B100NB 40 1m 44 34 4TVX0024B100NB 40 1m Microphone Microphone  Note  These operation values were obtained in an anechoic room. Sound pressure level will vary depending on a range Microphone of factors such as the construction of the particular room where the equipment is installed.  Operation sound level may differ depending on operation and ambient conditions. 1m 1m 2) NC curves (2) 4TVX0024B100NB 60 60 50 50 NC 45 40 NC 40 30 NC 35 HIGH NC 30 20 NC 25 LOW NC 20 NC 15 10 0 63 125 250 500 1000 2000 4000 Octave band center frequency(Hz) 62 8000 Sound pressure level (dB) Sound pressure level (dB) (1) 4TVX0018B100NB NC 45 40 NC 40 30 NC 35 HIGH NC 30 20 NC 25 LOW NC 20 NC 15 10 0 63 125 250 500 1000 2000 4000 8000 Octave band center frequency(Hz) VRF-PRC006-EN 7-5. Temperature and air flow distribution 4TVX0018-0024B100NB (Floor installation) (1) Cooling air velocity distribution  Discharge angle : 36° 3m (9.8 ft) Ceiling height 0.2m/s (0.66ft/s) 0.4m/s (1.31ft/s) 0m (0 ft) 2m (6.6 ft) 1m (3.3 ft) 5m 4m (13.1 ft) (16.4 ft) Floor distance 3m (9.8 ft) 6m (19.7 ft) (2) Cooling temperature distribution 7m (23.0 ft) 1m (3.3 ft) Indoor units 0.6m/s (1.97ft/s) 2m (6.6 ft) 8m (26.2 ft)  Discharge angle : 36° Ceiling height 3m (9.8 ft) 2m (6.6 ft) 25 (77.0°F) 22 (71.6°F) 21 (69.8°F) 23 (73.4°F) 24 (75.2°F) 1m (3.3 ft) 24 (75.2°F) 25 (77.0°F) 0m (0 ft) 2m (6.6 ft) 1m (3.3 ft) 5m 4m (13.1 ft) (16.4 ft) Floor distance 3m (9.8 ft) 6m (19.7 ft) (3) Heating air velocity distribution Ceiling height 0.4m/s (1.31ft/s) 0.2m/s (0.66ft/s) 0.6m/s (1.97ft/s) 0.8m/s (2.62ft/s) 7m (23.0 ft) 8m (26.2 ft)  Discharge angle : 54° 3m (9.8 ft) 0.6m/s (1.97ft/s) 1.0m/s (3.28ft/s) 0.4m/s (1.31ft/s) 2m (6.6 ft) 0.2m/s (0.66ft/s) 1.2m/s (3.94ft/s) 1m (3.3 ft) 0m (0 ft) 1m (3.3 ft) 2m (6.6 ft) 3m (9.8 ft) 5m 4m (13.1 ft) (16.4 ft) Floor distance 6m (19.7 ft) (4) Heating temperature distribution 7m (23.0 ft) 8m (26.2 ft)  Discharge angle : 54° 3m (9.8 ft) 27 (80.6°F) Ceiling height 29 (84.2°F) 31 (87.8°F) 29 (84.2°F) 2m (6.6 ft) 27 (80.6°F) 25 (77.0°F) 1m (3.3 ft) 23 (73.4°F) 21 (69.8°F) 0m (0 ft) 1m (3.3 ft) VRF-PRC006-EN 2m (6.6 ft) 3m (9.8 ft) 5m 4m (13.1 ft) (16.4 ft) Floor distance 6m (19.7 ft) 7m (23.0 ft) 8m (26.2 ft) 63 8 Ceiling Suspended (Floor) 4TVX0018-0024B100NB (Ceiling installation) (1) Cooling air velocity distribution  Discharge angle : 36° 3m (9.8 ft) Ceiling height 1.0m/s (3.28ft/s) 2m (6.6 ft) 0.2m/s (0.66ft/s) 0.2m/s (0.66ft/s) 0m (0 ft) 1m (3.3 ft) 1m (3.3 ft) 0.4m/s (1.31ft/s) 0.6m/s (1.97ft/s) 2m (6.6 ft) 5m 4m (13.1 ft) (16.4 ft) Floor distance 3m (9.8 ft) 6m (19.7 ft) (2) Cooling temperature distribution 7m (23.0 ft) 8m (26.2 ft)  Discharge angle : 36° 3m (9.8 ft) Ceiling height 25 (77.0°F) 21 (69.8°F) 2m (6.6 ft) 24 (75.2°F) 24 (75.2°F) 1m (3.3 ft) 23 (73.4°F) 0m (0 ft) 1m (3.3 ft) 23 (73.4°F) 2m (6.6 ft) 5m 4m (13.1 ft) (16.4 ft) Floor distance 3m (9.8 ft) 6m (19.7 ft) (3) Heating air velocity distribution 7m (23.0 ft)  Discharge angle : 54° 3m (9.8 ft) Ceiling height 0.2m/s (0.66ft/s) 0.8m/s (2.62ft/s) 2m (6.6 ft) 0.4m/s (1.31ft/s) 1.0m/s (3.28ft/s) 0.6m/s (1.97ft/s) 8m (26.2 ft) 0.4m/s (1.31ft/s) 1m (3.3 ft) 0.2m/s (0.66ft/s) 0m (0 ft) 1m (3.3 ft) 2m (6.6 ft) 5m 4m (13.1 ft) (16.4 ft) Floor distance 3m (9.8 ft) 6m (19.7 ft) (4) Heating temperature distribution 7m (23.0 ft) 8m (26.2 ft)  Discharge angle : 54° 3m (9.8 ft) Ceiling height 25 (77.0°F) 2m (6.6 ft) 33 (91.4°F) 31 (87.8°F) 27 (80.6°F) 64 1m (3.3 ft) 1m (3.3 ft) 23 (73.4°F) 21 (69.8°F) 0m (0 ft) 25 (77.0°F) 21 (69.8°F) 2m (6.6 ft) 3m (9.8 ft) 5m 4m (13.1 ft) (16.4 ft) Floor distance 6m (19.7 ft) 7m (23.0 ft) 8m (26.2 ft) VRF-PRC006-EN 18 High Wall 8-1. Specifications Technical specifications Model Name Power Supply Performance 208~230/60/1 208~230/60/1 Capacity (Nominal)1 7,500 9,500 12,000 Heating Btu/h 8,500 10,500 13,500 Power Input (Nominal)1 Cooling 37.0 37.0 45.0 37.0 37.0 45.0 Current Input (Nominal)1 Cooling 0.25 0.25 0.30 Heating Heating Type (Qty.) Output (Each) Airflow Rate H/M/L External Static Pressure Min/Std/Max Sound2 Additional Features 1. 2. 3. 4. 5. A - 0.25 0.25 0.30 Crossflow Fan Crossflow Fan Crossflow Fan W 23 x 1 23 x 1 23 x 1 Cfm 275/240/200 290/255/215 325/295/255 In. Wg - - - Ø inch 1/4 1/4 1/4 Gas Pipe Ø inch 1/2 1/2 1/2 Drain Pipe Ø in (mm) ID 11/16" hose ID 11/16" hose ID 11/16" hose Type - R-410A R-410A R-410A Control Method3 - EEV (not included) EEV (not included) EEV (not included) Db(A) 31.0/29.0/27.0 31.0/29.0/27.0 37.0/33.0/29.0 lbs. 18.75 18.75 18.75 Sound Pressure H/M/L Net Weight External Dimensions W Shipping Weight lbs. 24.25 24.25 24.25 Net Dimensions (WxHxD) inches 32 1/2 x 11.25 x 7 1/2 32 1/2 x 11.25 x 7 1/2 32 1/2 x 11.25 x 7 1/2 Shipping Dimensions (WxHxD) inches 35 1/2 x 13 7/8 x 10 3/8 35 1/2 x 13 7/8 x 10 3/8 35 1/2 x 13 7/8 x 10 3/8 - Washable Filter Washable Filter Washable Filter Air Filter Indoor units 208~230/60/1 Liquid Pipe Refrigerant R-410A 4TVW0012B100NB Btu/h Motor Piping Connections 4TVW0009B100NB Cooling Power Fan 4TVW0007B100NB Nominal capacity based on 25 ft. of equivalent refrigerant piping with 0 ft. level difference. - Cooling: Indoor temperature 80°F DB, 67°F WB/Outdoor temperature 95°F DB, 75°F WB - Heating: Indoor temperature 70°F DB, 60°F WB/Outdoor temperature 47°F DB, 43°F WB Sound pressure was acquired in a dead room. Actual noise level may be different depending on installation conditions. EEV kit to be ordered separately, see application guide on page 74. Condensate pump, if necessary, to be field supplied Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. VRF-PRC006-EN 65 8 High Wall Technical specifications Model Name Power Supply Performance 208~230/60/1 208~230/60/1 208~230/60/1 Capacity (Nominal)1 18,000 20,000 23,200 Heating Btu/h 20,000 23,000 23,800 Power Input (Nominal)1 Cooling 55.0 57.0 60.0 55.0 57.0 60.0 Current Input (Nominal)1 Cooling 0.36 0.38 0.40 Heating Heating Type (Qty.) Output (Each) Airflow Rate H/M/L External Static Pressure Min/Std/Max Liquid Pipe Refrigerant Sound2 Additional Features 1. 2. 3. 4. 5. 66 W A - 0.36 0.38 0.40 Crossflow Fan Crossflow Fan Crossflow Fan W 40 x 1 40 x 1 40 x 1 Cfm 425/370/315 495/440/385 495/440/385 In. Wg - - - Ø inch 1/4 1/4 3/8 Gas Pipe Ø inch 1/2 1/2 5/8 Drain Pipe Ø in (mm) ID 11/16" hose ID 11/16" hose ID 11/16" hose Type - R-410A R-410A R-410A Control Method3 - EEV (not included) EEV (not included) EEV (not included) Db(A) 44.0/41.0/38.0 44.0/41.0/38.0 45.0/42.0/38.0 lbs. 27.55 27.55 27.55 Sound Pressure H/M/L Net Weight External Dimensions 4TVW0024B100NB Btu/h Motor Piping Connections 4TVW0020B100NB Cooling Power Fan 4TVW0018B100NB lbs. 34.2 34.2 34.2 Net Dimensions (WxHxD) Shipping Weight inches 41 7/8 x 11 3/4 x 8 5/8 41 7/8 x 11 3/4 x 8 5/8 41 7/8 x 11 3/4 x 8 5/8 Shipping Dimensions (WxHxD) inches 44 3/4 x 14 7/8 x 11 7/8 44 3/4 x 14 7/8 x 11 7/8 44 3/4 x 14 7/8 x 11 7/8 - Washable Filter Washable Filter Washable Filter Air Filter Nominal capacity based on 25 ft. of equivalent refrigerant piping with 0 ft. level difference. - Cooling: Indoor temperature 80°F DB, 67°F WB/Outdoor temperature 95°F DB, 75°F WB - Heating: Indoor temperature 70°F DB, 60°F WB/Outdoor temperature 47°F DB, 43°F WB Sound pressure was acquired in a dead room. Actual noise level may be different depending on installation conditions. EEV kit to be ordered separately, see application guide on page 74. Condensate pump, if necessary, to be field supplied Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. VRF-PRC006-EN 8-2. Dimensional drawing 4TVW0007-0012B100NB Unit:mm(inch) Indoor units 285(11-1/4) 5 6 825(32-1/2) 189(7 1/2) 4 2 No. 1 3 Name 1 Liquid pipe connection 2 Gas pipe connection Drain pipe connection Conduit for power supply & communication wiring Air inlet grille Air outlet louver 3 4 5 6 VRF-PRC006-EN 7.5 MBH Description 9.5 MBH 12.0 MBH Ø6.35 (1/4") Flare Ø12.70 (1/2") Flare ID 18 hose / ID 11/16" hose - 67 8 High Wall 4TVW0018-0024B100NB Unit : mm(inch) 298(11-3/4) 5 6 1065(41-7/8) 218(8-5/8) 4 2 No. Name 3 18.0 MBH Description 20.0 MBH 23.2 MBH 1 Liquid pipe connection Ø6.35 (1/4") Flare 2 Gas pipe connection Drain pipe connection Conduit for power supply & communication wiring Air inlet grille Air outlet louver Ø12.70 (1/2") Flare Ø15.88 (5/8") Flare ID 18 hose / ID 11/16" hose 3 4 5 6 68 1 Ø9.52 (3/8") Flare - VRF-PRC006-EN 8-3. Electrical wiring diagram Indoor units VRF-PRC006-EN 69 8 High Wall 8-4. Sound pressure level Operation sound level Unit : dB(A) 1m 1m Microphone Model High Low Model High Low 4TVW0007B100NB 31 27 4TVW0018B100NB 44 38 4TVW0009B100NB 31 27 4TVW0020B100NB 44 38 4TVW0012B100NB 37 29 4TVW0024B100NB 45 38  Note  These operation values were obtained in an anechoic room. Sound pressure level will vary depending on a range of factors such as the construction of the particular room where the equipment is installed.  Operation sound level may differ depending on operation and ambient conditions. NC curves (1) 4TVW0007B100NB (2) 4TVW0009B100NB 45 45 NC 45 NC 40 35 30 HIGH NC 35 LOW NC 30 25 20 NC 25 15 NC 20 10 NC 15 5 0 NC 45 40 Sound pressure level (dB) Sound pressure level (dB) 40 NC 40 35 30 HIGH NC 35 LOW NC 30 25 20 NC 25 15 NC 20 10 NC 15 5 63 125 250 500 1000 2000 4000 0 8000 63 Octave band center frequency(Hz) (3) 4TVW0012B100NB 1000 2000 4000 8000 60 HIGH NC 40 LOW NC 35 NC 30 25 20 NC 25 15 NC 20 10 NC 15 Sound pressure level (dB) Sound pressure level (dB) 500 NC 45 40 30 250 (4) 4TVW0018B100NB 45 35 125 Octave band center frequency(Hz) 50 HIGH 40 LOW NC 45 NC 40 NC 35 30 NC 30 NC 25 20 NC 20 NC 15 10 5 0 63 125 250 500 1000 2000 4000 Octave band center frequency(Hz) 70 8000 0 63 125 250 500 1000 2000 4000 8000 Octave band center frequency(Hz) VRF-PRC006-EN NC curves (5) 4TVW0020B100NB (6) 4TVW0024B100NB 60 40 LOW HIGH NC 45 NC 40 NC 35 30 NC 30 NC 25 20 NC 20 NC 15 10 0 63 125 250 500 1000 2000 4000 Octave band center frequency(Hz) VRF-PRC006-EN 8000 Sound pressure level (dB) HIGH 45 NC 45 LOW NC 40 35 NC 35 Indoor units Sound pressure level (dB) 55 50 NC 30 25 NC 25 NC 20 15 5 NC 15 63 125 250 500 1000 2000 4000 8000 Octave band center frequency(Hz) 71 8 High Wall 8-5. Temperature and air flow distribution 4TVW0007-0012B100NB (1) Cooling air velocity distribution  Discharge angle : 60° Ceiling height 3m (9.8 ft) 2m (6.6 ft) 1.4m/s (4.59ft/s) 1.2m/s (3.94ft/s) 1.0m/s 0.2m/s 0.6m/s (3.28ft/s) (0.66ft/s) (1.97ft/s) 0.8m/s 0.6m/s (2.62ft/s) (1.97ft/s) 0m (0 ft) 2m (6.6 ft) 1m (3.3 ft) 1m (3.3 ft) 0.4m/s (1.31ft/s) 0.2m/s (0.66ft/s) 5m 4m (13.1 ft) (16.4 ft) Floor distance 3m (9.8 ft) 6m (19.7 ft) (2) Cooling temperature distribution 7m (23.0 ft) 8m (26.2 ft)  Discharge angle : 60° Ceiling height 3m (9.8 ft) 2m (6.6 ft) 26 (78.8°F) 23 (73.4°F) 1m (3.3 ft) 25 (77.0°F) 0m (0 ft) 24 (75.2°F) 25 (77.0°F) 2m (6.6 ft) 1m (3.3 ft) 5m 4m (13.1 ft) (16.4 ft) Floor distance 3m (9.8 ft) 6m (19.7 ft) (3) Heating air velocity distribution 7m (23.0 ft) 8m (26.2 ft)  Discharge angle : 60° 3m (9.8 ft) Ceiling height 0.2m/s (0.66ft/s) 0.4m/s (1.31ft/s) 2m (6.6 ft) 1.8m/s (5.90ft/s) 1.2m/s (3.94ft/s) 1.0m/s (3.28ft/s) 0.2m/s (0.66ft/s) 0.4m/s (1.31ft/s) 0.6m/s (1.97ft/s) 1m (3.3 ft) 0.8m/s (2.62ft/s) 0m (0 ft) 1m (3.3 ft) 2m (6.6 ft) 5m 4m (13.1 ft) (16.4 ft) Floor distance 3m (9.8 ft) 6m (19.7 ft) (4) Heating temperature distribution 7m (23.0 ft) 8m (26.2 ft)  Discharge angle : 60° Ceiling height 3m (9.8 ft) 2m (6.6 ft) 25 (77.0°F) 27 (80.6°F) 31 (87.8°F) 25 (77.0°F) 23 (73.4°F) 1m (3.3 ft) 21 (69.8°F) 29 (84.2°F) 0m (0 ft) 72 1m (3.3 ft) 2m (6.6 ft) 3m (9.8 ft) 5m 4m (13.1 ft) (16.4 ft) Floor distance 6m (19.7 ft) 7m (23.0 ft) 8m (26.2 ft) VRF-PRC006-EN 4TVW0018-0024B100NB (1) Cooling air velocity distribution  Discharge angle : 60° Ceiling height 3m (9.8 ft) 2m (6.6 ft) 1.4m/s (4.59ft/s) 1.0m/s (3.28ft/s) 0m (0 ft) 0.8m/s (2.62ft/s) 2m (6.6 ft) 1m (3.3 ft) 0.6m/s (1.97ft/s) 3m (9.8 ft) Indoor units 1m (3.3 ft) 1.2m/s (3.94ft/s) 0.4m/s (1.31ft/s) 5m 4m (13.1 ft) (16.4 ft) Floor distance 6m (19.7 ft) 7m (23.0 ft) (2) Cooling temperature distribution 8m (26.2 ft)  Discharge angle : 60° 3m (9.8 ft) Ceiling height 25 (77.0°F) 2m (6.6 ft) 24 (75.2°F) 23 (73.4°F) 1m (3.3 ft) 22 (71.6°F) 23 (73.4°F) 0m (0 ft) 22 (71.6°F) 1m (3.3 ft) 2m (6.6 ft) 3m (9.8 ft) 5m 4m (13.1 ft) (16.4 ft) Floor distance 6m (19.7 ft) 7m (23.0 ft) (3) Heating air velocity distribution 8m (26.2 ft)  Discharge angle : 60° 3m (9.8 ft) 0.2m/s (0.66ft/s) Ceiling height 0.4m/s (1.31ft/s) 0.6m/s (1.97ft/s) 1.2m/s (3.94ft/s) 1.0m/s (3.28ft/s) 0.8m/s (2.62ft/s) 0m (0 ft) 1m (3.3 ft) 2m (6.6 ft) 0.2m/s (0.66ft/s) 3m (9.8 ft) 5m 4m (13.1 ft) (16.4 ft) Floor distance 6m (19.7 ft) 7m (23.0 ft) (4) Heating temperature distribution 2m (6.6 ft) 1m (3.3 ft) 8m (26.2 ft)  Discharge angle : 60° Ceiling height 3m (9.8 ft) 2m (6.6 ft) 27 (80.6°F) 27 (80.6°F) 29 (84.2°F) 31 29 (84.2°F) (87.8°F) 0m (0 ft) 1m (3.3 ft) VRF-PRC006-EN 2m (6.6 ft) 3m (9.8 ft) 5m 4m (13.1 ft) (16.4 ft) Floor distance 25 (77.0°F) 1m (3.3 ft) 23 (73.4°F) 6m (19.7 ft) 7m (23.0 ft) 8m (26.2 ft) 73 EEV Kit Application Table Indoor unit type and combinations EEV KIT Single room application Double room application Triple room application 4TVW0018B100NB 4TVW0020B100NB 4TVW0024B100NB 4TVW0007B100NB 4TVW0009B100NB 4TVW0012B100NB 4TVX0018B100NB 4TVX0024B100NB 4EEVEVA24SA000 Any 1 N/A 4EEVEVA32SA000 N/A Any 1 4EEVXDA24K132A Any 1 4EEVXDA24K200A Any 2 N/A 4EEVXDA32K200A N/A Any 2 4EEVXDA24K232A Any 2 4EEVXDA24K300A Any 3 4EEVXDA32K224A Any 1 4EEVXDA32K300A N/A Plus Plus Any 1 Any 1 N/A Plus Any 2 Any 3 Note: Cassette and concealed (fan coil) type indoor units come with a factory installed and cannot be installed with the above EEV kits. 74 VRF-PRC006-EN Variable Refrigerant Flow (VRF) Multi-Split AC and HP AHRI Standard 1230 Trane optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, Trane offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.Trane.com. Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. © 2013 Trane  All rights reserved VRF-PRC006-EN  19 Sep 2013 (NEW) We are committed to using environmentally conscious print practices that reduce waste.