Preview only show first 10 pages with watermark. For full document please download

Category 6 Sftp Lan Cable

   EMBED


Share

Transcript

Category 6 SFTP LAN Cable Linxcom Shielded and Foiled Twisted Pair (SFTP) Category 6 (CAT6) copper cable is a 23 American Wire Gauge (AWG) used ideally for Gigabit Ethernet, Multimedia, video, voice and data. Our cables are verified by EC and third party organization and comply with ISO11801. All outer jackets can be PVC or LSZH upon customers’ requests. Features & Benefits           UL & 3P Certified 4 pairs twisted pair cable Performance characterized to 600 MHz All cables meet or exceed the requirement proposed by TIA /EIA 568 B .2 ,ISO/IEC 11801 Category 6 23AWG insulated copper conducts with PVC jacket Twisted pairs are brightly coloured and distinguished at a glance the cross frameworks are stripped to match corresponding colour pairs Ultra smooth jacket makes this cable easy to pull in tight spaces 305 metres packaged in full boxes or 500m reels Application  Horizontal wiring in Local Area Networks (LAN) Colouring Pair 1 Blue, Blue/White Pair 2 Orange, Orange/White Construction Conductor American Wire Gauge (AWG) Insulation Average Thickness (±0.03mm) Minimum Point Thickness (mm) Insulation Diameter (±0.05mm) Twisting Lay Length (mm) Cable Laying Length (±mm) Filler Jacket Average Thickness (±0.05mm) Minimum Point Thickness (mm) Outer Diameter (±0.2mm) Drain Wire/Braiding Solid Bare Copper 23 HDPE 0.22 0.20 1.00 30 (underneath) 140 PE PVC or LSZH 0.50 0.40 6.20 Tinned Copper/CCAM Pair 3 Green, Green/White Pair 4 Brown, Brown/White Category 6 SFTP LAN Cable Electrical Characteristics Category 6 SFTP LAN Cable Frequency (MHz) 1 4 8 10 16 20 25 31.25 62.5 100 150 200 250 Return loss (dB) 20.0 23.0 24.5 25.0 25.0 25.0 24.3 23.6 21.5 20.1 18.9 18 17.3 Attenuation (dB/100m) 2.0 3.8 5.3 6.0 7.6 8.5 9.5 10.7 15.4 19.8 24.7 29.0 32.8 NEXT (dB) 74.3 65.3 60.8 59.3 56.2 54.8 53.3 51.9 47.4 44.3 41.7 39.8 38.3 ACR (dB) 72.3 61.5 55.4 53.3 48.7 46.3 43.8 41.2 32.0 24.5 16.9 10.8 5.5 Frequency (MHz) 1 4 8 10 16 20 25 31.25 62.5 100 150 200 250 PSNEXT (dB) 72.3 63.3 58.8 57.3 54.2 52.8 51.3 49.9 45.4 42.3 39.7 37.8 36.3 ELFEXT (dB/100m) 67.8 55.8 49.7 47.8 43.7 41.8 39.8 37.9 31.9 27.8 24.3 21.8 19.8 PSELFEXT (dB/100m) 64.8 52.8 46.7 44.8 40.7 38.8 36.8 34.9 28.9 24.8 21.3 18.8 16.8 Delay (ns/100m) 570.0 552.0 546.7 545.4 543.0 542.0 541.2 540.4 538.6 537.6 536.9 536.5 536.3 1.0-100.0MHz Impedance (ohms) 100.0-250MHz Delay Skew (ns/100m) 1.0-250.0MHz Impedance (ohms) Pair-to-Ground Capacitance Unbalance (pF/100m) Max. Conductor DC Resistance 20oC (ohms/km) Resistance Unbalance (%) 100 ± 15 100 ± 22 <=45 <=330 73.2 <=5 Category 6 SFTP LAN Cable Mechanical Characteristics Test Object Test Material Before Tensile Strength (Mpa) Aging Elongation (%) Aging Condition (oC x hrs) After Tensile Strength (Mpa) Aging Elongation (%) Cold Bend (-20±2oCx4hrs) Jacket PVC >=13.8 >=100 100 x 240 >=85% of unaged >=50% of unaged No crack Electrical Information Voltage Current Dielectric Withstanding Voltage Operating Temperature 150V 1.5A 1000V RMS -20°C to 65°C Ordering Information Using the available configurations amend/create a part number using the formula below. Construction SFTP (Shielded & Foiled SFTP Twisted Pair) SFTP 6 Category Category 6 (CAT6) 6 Jacket PVC PVC LSZH LSZH PVC Length 305m Box 305 500m Reel 500 Example: SFTP6PVC305 – Category 6 Shielded & Foiled Twisted Pair LAN Cable PVC Jacket – 305m Box For any queries, please contact the Linxcom team using the details below. 305