Cavi Multicoppia Categoria 5

   EMBED


Share

Transcript

TX5000™ U/UTP Copper Cable S P E C I F I C AT I O N S H E E T specifications Category 5 cable shall meet the ANSI/TIA-568-C.2 and ISO 11801 Category 5 component standards. The conductors shall be 24 AWG with HDPE insulation. The copper conductors shall be twisted in pairs, separated by an integrated pair separator, and covered with a UV- and abrasion-resistant PVC jacket. technical information Electrical performance: Certified channel performance in a 4-connector configuration up to 100 meters and exceeds ISO 11801 Class D and ANSI/TIA-568-C.2 Category 5 standards at swept frequencies up to 100 MHz Certified component performance up to 100 meters and exceeds the component requirement of IEC 61156-5 and ANSI/TIA-568-C.2 Category 5 component standards at swept frequencies up to 100 MHz Conductors/ insulators: 24 AWG solid bare annealed copper Flame rating: CM: UL 1685 Installation tension: 400 N (90 lbf) maximum Temperature rating: 0°C to 50°C (32°F to 122°F) during installation -20°C to 60°C (-4°F to 140°F) during operation Cable jacket: CM: Flame-retardant PVC Cable diameter: 25-pair: 11.8mm (0.465 in.) nominal 50-pair: 17.5mm (0.689 in.) nominal 100-pair: 24.5mm (0.964 in.) nominal Cable weight: 25-pair: 61.7 kg/305m (136 lbs./1000 ft.) 50-pair: 146.1 kg/305m (322 lbs./1000 ft.) 100-pair: 186.9 kg/305m (412 lbs./1000 ft.) Packaging: 305m (1000 ft.) on a reel Package tested to ISTA Procedure 1A key features and benefits Easy payout reel Ensures proper performance and provides quick installation; supplied 305m (1000 ft.) on a reel Descending length cable markings Easy identification of remaining cable reduces installation time and cable scrap Reduced attenuation Maximizes the amount of signal that reaches the receiver and increases bandwidth applications TX5000 ™ U/UTP Copper Cable is a component of the Panduit ® TX5000 ™ Copper Cabling System. This end-to-end system provides Gigabit Ethernet performance with usable bandwidth beyond 100 MHz. With certified performance to the ANSI/TIA-568-C.2 Category 5 and ISO 11801 Class D standards, this system will support the following applications: • Ethernet 10BASE-T, 100BASE-T (Fast Ethernet), 1000BASE-T (Gigabit Ethernet) • 155 Mb/s ATM, 622 Mb/s ATM • Token Ring 4/16 w w w. p a n d u i t . c o m TX5000 ™ U/UTP Multi-Pair Copper Cable 25-pair: 50-pair: 100-pair: PUC5025WH-A PUC5050WH-A PUC50100WH-A TX5000™ U/UTP Copper Cable additional specifications Mechanical Test Ultimate Breaking Strength >2500 N (562 Ibf) Minimum Bend Radius 2x cable diameter Electrical Test Nominal Velocity of Propagation (NVP) 67% cable construction Conductor Wire Conductor Wire Conductor Insulator Twisted Pair Conductor Insulator Twisted Pair Polyester Film Polyester Film Sheath (PVC or LSZH) Sheath (PVC or LSZH) Unit (12 or 13 Pairs) Unit (25 Pairs) Sub-Unit (3 or 4 Pairs Grouped Together) Rip Cord Sub-Unit (3 or 4 Pairs Grouped Together) 25 PAIR Unit Binder Tape 50 PAIR Conductor Wire Twisted Pair Conductor Insulator Polyester Film Sheath (PVC or LSZH) Unit (25 Pairs) Sub-Unit (3 or 4 Pairs Grouped Together) Rip Cord 100 PAIR Unit Binder Tape WORLDWIDE SUBSIDIARIES AND SALES OFFICES PANDUIT CANADA Markham, Ontario [email protected] Phone: 800.777.3300 PANDUIT EUROPE LTD. London, UK [email protected] Phone: 44.20.8601.7200 PANDUIT SINGAPORE PTE. LTD. Republic of Singapore [email protected] Phone: 65.6305.7575 PANDUIT JAPAN Tokyo, Japan [email protected] Phone: 81.3.6863.6000 PANDUIT LATIN AMERICA Guadalajara, Mexico [email protected] Phone: 52.33.3777.6000 PANDUIT AUSTRALIA PTY. LTD. Victoria, Australia [email protected] Phone: 61.3.9794.9020 For a copy of Panduit product warranties, log on to www.panduit.com/warranty For more information Visit us at www.panduit.com Contact Customer Service by email: [email protected] or by phone: 800.777.3300 and reference COSP205 ©2011 Panduit Corp. ALL RIGHTS RESERVED. WW-COSP205 7/2011