Preview only show first 10 pages with watermark. For full document please download

Cb_sp_at(p)

   EMBED


Share

Transcript

RAV Light Commercial SUPER DIGITAL INVERTER INVERTER OUTDOOR UNIT SP_AT(P) Vector controlled inverter The Super Digital Inverter, series 4, sets a new limit for the industry energy performance. Advanced air management system: high efficiency fan motors, larger fans and new fan grille design. Piping and operating limits improved. The new system can work at extremely low temperatures, in cooling and heating. Admitted pipe length is up to 75 m. Intelligent Power Drive Unit, which produces a power supply whose wide range of frequencies and voltage provide superb control and energy efficiency. The structure and magnetic action of the new Eco-driving twin- rotary compressors provide excellent energy performance at full load as well as in partial load conditions (operation down to 10 rps). Long pipe runs, up to 75 m length and 30 m elevation for increased installation flexibility (4HP ÷ 6HP). Wide operating range: down to -15 °C in cooling mode and down to -20 °C in heating mode (2HP ÷ 6HP). OUTDOOR UNITS RAV-SP404ATP-E RAV-SP454ATP-E RAV-SP564ATP-E 66 RAV-SP804ATP-E RAV-SP1104AT-E RAV-SP1104AT8-E RAV-SP1404AT-E RAV-SP1404AT8-E RAV-SP1604AT8-E CASSETTE DUCTED HI-WALL CEILING RAV-SM_UTP RAV-SM_MUT RAV-SM_BTP RAV-SM_SDT RAV-SM_KRT RAV-SM_CTP Physical data Outdoor unit / Single phase / Series 4 SP_AT(P) Outdoor unit Air Flow (max) Sound pressure level (h) Sound power level (h) Operating range (DB) Sound pressure level (h) Sound power level (h) Operating range (WB) Dimensions (HxWxD) Weight Compressor type Flare connections Gas Liquid Minimum pipe length Maximum pipe length Maximum height difference Chargeless pipe length Power supply m3/h - l/s dB(A) dB(A) °C dB(A) dB(A) °C mm kg C C C H H H inch inch m m m m V-ph-Hz RAV-SP454ATP-E 1,7 HP RAV-SP564ATP-E 2 HP RAV-SP804ATP-E 3 HP RAV-SP1104AT-E 4 HP RAV-SP1404AT-E 5 HP 2400 - 667 45 62 -15~43 47 64 -15~15 550 x 780 x 290 40 DC Twin Rotary 2400 - 667 45 62 -15~43 47 64 -15~15 550 x 780 x 290 40 DC Twin Rotary 2400 - 667 47 63 -15 ~ 43 48 64 -20~15 550 x 780 x 290 44 DC Twin Rotary 3000 - 833 48 64 -15~43 49 65 -20~15 890 x 900 x 320 66 DC Twin Rotary 6060 - 1683 49 66 -15~43 50 67 -20~15 1340 × 900 × 320 93 DC Twin Rotary 6180 - 1716 51 68 -15~43 52 69 -20~15 1340x900x320 93 DC Twin Rotary 1/2 1/4 5 30 30 20 220/240-1-50 1/2 1/4 5 30 30 20 220/240-1-50 1/2 1/4 5 50 30 20 220/240-1-50 5/8 3/8 5 50 30 30 220/240-1-50 5/8 3/8 3 75 30 30 220/240-1-50 5/8 3/8 3 75 30 30 220/240-1-50 Physical data Outdoor unit / Three phase / Series 4 SP_AT8 Outdoor unit Air Flow (max) Sound pressure level (h) Sound power level (h) Operating range (DB) Sound pressure level (h) Sound power level (h) Operating range (WB) Dimensions (HxWxD) Weight Compressor type Flare connections Gas Liquid Minimum pipe length Maximum pipe length Maximum height difference Chargeless pipe length Power supply RAV-SP404ATP-E 1,5 HP m3/h - l/s dB(A) dB(A) °C dB(A) dB(A) °C mm kg inch inch m m m m V-ph-Hz C C C H H H RAV-SP1104AT8-E 4 HP RAV-SP1404AT8-E 5 HP RAV-SP1604AT8-E 6 HP 6060 - 1683 49 66 -15 ~ 46 50 67 -20 ~ 15 1340x900x320 95 DC Twin Rotary 6180 - 1717 51 68 -15 ~ 46 52 69 -20 ~ 15 1340x900x320 95 DC Twin Rotary 6180 - 1717 51 68 -15 ~ 46 53 70 -20 ~ 15 1340x900x320 95 DC Twin Rotary 5/8 3/8 3 75 30 30 380/415-3N-50 5/8 3/8 3 75 30 30 380/415-3N-50 5/8 3/8 3 75 30 30 380/415-3N-50 C = cooling mode H = heating mode h= high speed 67