Transcript
CCTV Rack Mount Power Supplies Installation Guide Models Include:
Vertiline24C Vertiline24CD
- 24VAC or 28VAC @ 10 amp - Twenty-four (24) fuse protected outputs
- 24VAC or 28VAC @ 10 amp - Twenty-four (24) PTC protected outputs
Vertiline246C Vertiline246CD
- 24VAC or 28VAC @ 14 amp - Twenty-four (24) fuse protected outputs
Rev. 031808
- 24VAC or 28VAC @ 14 amp - Twenty-four (24) PTC protected outputs
More than just power.TM
Overview: Altronix Vertiline CCTV Rack Mount Power Supplies provide 24 power outputs in a space saving 1U EIA 19” rack mount chassis which may be rack, wall or shelf mounted. The units feature individually selectable 24VAC and/or 28VAC power outputs with surge suppression. Vertiline CCTV Rack Mount Power Supplies are also available in eight (8) and sixteen (16) output models with various power ratings.
Specifications: Features (cont’d):
Input: • 115VAC 60 Hz.
• Illuminated master power disconnect circuit breaker with manual reset. • IEC 320 - 3-wire grounded line cord (detachable). • Removable terminal blocks with locking screw flange.
Output: • Twenty-four (24) individually selectable 24VAC or 28VAC power outputs with OFF position. • Twenty-four (24) external blade fuse or PTC protected outputs. • Surge suppression.
Mechanical: • Units can be rack, wall or shelf mounted. • Modular 1U standard EIA 19” rack mount chassis. • Enclosure Dimensions (H x W x D approx.): 1.625” x 19.125” x 8.5” (41.3mm x 486mm x 216mm).
Features: • Twenty-four (24) power LED indicators.
-
10 amp
24
-
PTC
14 amp
24
Fused
-
14 amp
24
-
PTC
3 3 amp amp 2.5 amp
10 3 amp amp
-
3 3 amp amp 2.5 amp
115VAC 60Hz Input Current
Fused
Main Fuse Rating
Class 2 Rated PowerLimited Output protection
24
Fuse Rating
Output Protection
10 amp
Current (max. per output)
Number of Outputs
Output Voltage (VAC) 24VAC Vertiline24C or 28VAC 24VAC Vertiline24CD or 28VAC 24VAC Vertiline246C or 28VAC 24VAC Vertiline246CD or 28VAC
Altronix Model Number
Total Output Current (Power)
Twenty-four (24) Output Rack Mount Configuration Reference Chart:
15 4 amp amp
-
Agency Listings
UL Listings and File Numbers
UL Listed for Commercial CCTV Equipment (UL 2044). CUL Listed - CSA Standard C22.2 No.1-04, Audio, Video and Similar Equipment.
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. This installation should be made by qualified service personnel and should conform to the National Electrical Code and all local codes. Installation Instructions:
1. 2. 3.
- 2 -
Attach mounting brackets to Vertiline unit for rack or wall mount installation (Figs. 4-5, pg. 7). Affix rubber pads to Vertiline for shelf installation (Fig. 6, pg. 7). Secure the unit in a rack, mount unit to a wall or place unit on a shelf as desired (unit should be spaced at least 3” from any video monitors). When installing the unit in a rack, allow for one half of a U spacing above the unit for ventilation. Plug the grounded AC line cord (included) into the IEC 320 connector of the Vertiline unit (Fig. 1f, pg. 4). Insert the plug end of the line cord into a grounded AC receptacle. Vertiline24C
4. Set illuminated master power disconnect circuit breaker to the (ON) position (Fig. 3, pg. 6). 5. Select 24VAC or 28VAC power output for cameras 1-24 with the corresponding voltage adjustment switches (Fig. 1b, pg. 4). 6. Measure output voltage before connecting cameras. This helps avoiding potential damage. All terminals with common suffix (P) “1P, 2P ...” are the same polarity. 7. Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 3, pg. 6). 8. Connect the power outputs of terminals marked [1P & 1N] to the power inputs of camera 1 (Fig. 2, pg. 5). Repeat this step for each additional camera (Outputs 2-24). After the wiring is completed, insert terminal block into the corresponding connector and secure by tightening the screws. 9. Upon completion of the wiring, set illuminated master power disconnect circuit breaker to the ON (RESET) position (Fig. 3, pg. 6). 10. The power LEDs (Green) on the faceplate for Outputs 1-24 will illuminate when AC power is present (Fig. 1a, pg. 4). If any of these LEDs are off, a loss of AC power output may be due to a blown fuse or a tripped PTC caused by a short circuit or overload condition. If all of the LEDs are OFF, there may be a complete loss of supply power to the Vertiline unit or the illuminated master power disconnect circuit breaker is in the OFF position or the main fuse 1-12 or 13-24 is blown (Fig. 1c, pg. 4).* To restore the power output for Vertiline24C or Vertiline246C: 1- Switch corresponding output voltage switch to the OFF position (Fig. 1b, pg. 4). 2- Eliminate the trouble condition. 3- Replace the corresponding automotive blade fuse.* 4- Switch output voltage switch to the 24VAC or 28VAC position as desired (Fig. 1b, pg. 4). To restore the power output for Vertiline24CD or Vertiline246CD: 1- Switch corresponding output voltage switch to the OFF position (Fig. 1b, pg. 4). 2- Eliminate the trouble condition. 3- Allow 1 minute for PTC to cool off. 4- Switch output voltage switch to the 24VAC or 28VAC position as desired (Fig. 1b, pg. 4). *Note: Replace fuses with same type and rating: Output fuses are rated @ 3 amp for all models. Main fuse ratings: 10 amp for Vertiline24C and Vertiline24CD. 15 amp for Vertiline246C and Vertiline246CD.
Vertiline24C
Automotive Blade Fuse
-3-
- 4 -
Vertiline24C
1
2
3
4 28VAC OFF 24VAC
5
N
P N
23
P N
22
P N
21
P N
20
P N
19
P N
18
P N
17
N
24
P N
23
P N
22
P N
21 P N
20 P N
19 P N
18 P N
17
P N
15
P N
28VAC OFF 24VAC
14
P N
P
N
16
P N
15
P N
14
9
P N
13
13
P
P
10
12
N
12
P N
28VAC OFF 24VAC
11
P N
10
P N
13
9
Main Fuse 1-12 N
12
P N
11
P N
10
P N
9
P
P
14
1d - Power Outputs: 24VAC or 28VAC.
Main Fuse 1-12
11
15
N
N
16
P N
7
P N
6
P N
17
5
P
18
19
N
4
20
P N
3
8
P N
7
P N
6
P N
5
P
N
4
P N
3
P N
P N
28VAC OFF 24VAC
1e - Output Fuses: Automotive blade fuses.
8
1b - Output voltage switches: Selects 24VAC or 28VAC or OFF for each output.
Vertiline24CD and Vertiline246CD do not have output fuses on the rear of the rack mount chassis. The output PTCs are located on the inside of the rack mount chassis.
Main Fuse 13-24
N
16
8
1c - Main Fuse: Protects the transformer against overload.
P
6
Vertiline24CD or Vertiline246CD (rear)
Main Fuse 13-24
24
Vertiline24C or Vertiline246C (rear)
OFF
RESET
7
1a - LED(s) 1-24: Power LED indicators.
Vertiline24C, Vertiline24CD, Vertiline246C or Vertiline246CD (front)
Fig. 1
2
2
P N
P N
21
1
1
P
P
23
24
AC POWER
AC POWER
1f - IEC 320 Connector: 115VAC 60Hz (grounded line cord included).
22
Vertiline24C
-5-
Main Fuse 13-24
OFF
RESET
Fig. 2
N
24
P N
23
P N
1
22
P N
21
2
P
3
4
N
20
P N
19
28VAC OFF 24VAC
P N
18
P N
5
17
P
6
7
N
16
8
P N
15
P N
28VAC OFF 24VAC
14
P N
9
13
P
10
Main Fuse 1-12
11
12
N
12
P N
28VAC OFF 24VAC
11
P N
Typical Hookup:
10
P N
13
9
P
14
15
N
16
8
P N
7
P N
6
P N
17
5
P
18
19
N
4
20
P N
3
P N
28VAC OFF 24VAC
2
P N
21
1
P
22
23
24
AC POWER
The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may be of sufficient magnitude to constitute an electric shock. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. CAUTION: To reduce the risk of electric shock do not open enclosure. There are no user serviceable parts inside. Refer servicing to qualified service personnel.
1U EIA 19” Rack Mount Chassis Mechanical Drawing & Dimensions (H x W x D): 1.625” x 19.125” x 8.5” (41.3mm x 486mm x 216mm) REAR 17.125” (434.97mm) 24
1.625” (41.275mm)
23
22
21
20
19
18
17
16
15
14
13
12
Main Fuse 13-24
11
10
9
8
7
6
5
4
3
2
1
Main Fuse 1-12 N
P N
P N
P N
P
N
P N
P N
P N
P
P N
N
P N
P N
P
N
P N
P N
P N
P
N
P N
P N
P N
P
N
P N
P N
P N
P AC POWER
TOP and BOTTOM
8.5” (215.9mm)
FRONT RESET
1
2
3
4
5 28VAC OFF 24VAC
6
7
8
28VAC OFF 24VAC
9
10
11
12
13 28VAC OFF 24VAC
14
15
16
17
18
19
20
28VAC OFF 24VAC
21
22
23
24
OFF
0.95” (24.13mm)
19.125” (485.775mm)
(ON)
Fig. 3 Power switch with built-in circuit breaker: OFF position - Switch not illuminated. Outputs not powered. RESET (ON) position - Switch illuminated. Outputs powered. Circuit breaker tripped - Switch not illuminated. Power LEDs on faceplate are not illuminated. Outputs not powered. To reset circuit breaker set power switch to the ON (RESET) position (Fig. 3, pg. 6).
- 6 -
Vertiline24C
Mounting Options: Rack Mount Installation 1. 2. 3.
Remove factory installed screws from both sides of rack chassis (Fig. 4a). Install mounting brackets (A) on the left and right sides of rack chassis using the two (2) flat head screws (B) (included) (Fig. 4b). Place unit into the desired EIA 19” rack position and secure with mounting screws (not included) (Fig. 4c).
Fig. 4 Fig. 4b
Fig. 4a Top
Fig. 4c Top
Front Left
Top Front Left
B
Front Left
Remove A
Wall Mount Installation 1. 2.
Install mounting brackets (A) on the left and right sides of rack chassis using two (2) flat head screws (B) (included) (Fig. 5a). Place unit at the desired location and secure with mounting screws (not included) (Fig. 5b). Caution: It is necessary to make sure that mounting screws are securely fastened to a beam when installing.
Fig. 5 Fig. 5b
Fig. 5a
B
A
Shelf Installation 1. Position and affix rubber pads (C) (included) at each corner on the bottom of the unit (Fig. 6). 2. Place unit in the desired location. Fig. 6
Mounting Hardware (Included):
A Two (2) mounting brackets Left Side
B Six (6) flat head screws for mounting brackets.
C Four (4) rubber pads. C
Vertiline24C
Rubber Pad -7-
Notes:
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 web site: www.altronix.com, e-mail:
[email protected], Lifetime Warranty, Made in U.S.A. IIVertiline24CSeries H05O - 8 -
MEMBER Vertiline24C