Preview only show first 10 pages with watermark. For full document please download

Ceiling-floor

   EMBED


Share

Transcript

Console & Ceiling Type Simple yet Functional Ceiling type indoor unit has two way installation options for the ceiling and floor, enabling you to use your available space more efficiently. You can enjoy crisp, powerful air spreading throughout your entire space from the compact unit in your ceiling or floor. Slim and Elegant Console 2Way Installation Features Depending on the available space and the purpose of the air conditioner, the indoor unit can be installed under the ceiling or on the floor. Indoor units Under Ceiling Floor Standing Compact but Powerful 200% Samsung Ceiling type air conditioner boasts a slim, compact design - half the size of our competitor’s with cooling power comparable to our competitor’s larger products. 136% Smaller 123% Lighter 118% 100% 100% SAMSUNG Company B Company A SAMSUNG Company B Company A 7.1kW Model Size 78 Weight 2013 SAMSUNG System Air Conditioners 79 9 Ceiling 9-1. Specifications 1) Technical specifications Model Power Supply Mode*1) Capacity Performance (Nominal) Power Cooling*2) Heating*3) *2) Power Input Cooling (Nominal) Heating*3) *2) Current Input Cooling (Nominal) Heating*3) Fan 7.1 Btu/h 19,100 24,200 kW 6.3 8.0 Btu/h 21,500 27,300 72 80 W A 72 77 0.33 0.35 Output W 60 120 Number of unit EA 1 1 CMM 14.00/13.00/12.00 18.00/16.50/15.00 Min / Std / Max l/s 233.33/216.67/200.00 300.00/275.00/250.00 mmAq - - Pa - - WG - - - 013054-105000-203838-330010 013054-105000-204747-330010 9.52 Ø, mm 6.35 Ø, inch 1/4 3/8 Ø, mm 12.70 15.88 Ø, inch 1/2 5/8 Ø, mm ID 18 HOSE ID 18 HOSE Power Below 20m / Source Wire over 20m mm2 1.5 / 2.5 1.5 / 2.5 Transmission Cable mm2 0.75~1.5 0.75~1.5 Type - R410A R410A Control Method - EEV NOT INCLUDED EEV NOT INCLUDED Drain Pipe Sound Pressure High / Mid / Low*4) dBA 40 / 37 / 34 44 / 42 / 40 Net Weight kg 21.00 21.00 Shipping Weight kg 25.50 25.50 mm 1000 x 650 x 200 1000 x 650 x 200 mm 1080 x 730 x 300 1080 x 730 x 300 - - - Panel Net Weight kg - - Shipping Weight kg - - Net Dimensions (W×H×D) mm - - Shipping Dimensions (W×H×D) mm - - - / Model - - mm/liter/h - - - Long life filter Long life filter Dimensions Net Dimensions (W×H×D) Shipping Dimensions (W×H×D) Panel model Panel Size 5.6 0.29 Piping Connections Gas Pipe Sound HP/HR kW Sirocco Fan Liquid Pipe Refrigerant HP/HR 0.28 Option Code Field Wiring 1, 2, 220~240, 50 - Sirocco Fan Air Flow Rate H/M/L (UL) External Pressure AM071FNCDEH✴✴✴ 1, 2, 220~240, 50 - Type Motor AM056FNCDEH✴✴✴ Ø, #, V, Hz Drain pump Drain pump Additional Accessories Air Filter Max. lifting Height / Displacement * Specifications may be subject to change without prior notice for product improvement. *1) Mode - HP : Heat Pump, HR : Heat Recovery *2) Nominal cooling capacities are based on; - Indoor temperature : 27°C DB, 19°C WB - Outdoor temperature : 35°C DB, 24°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m *3) Nominal heating capacities are based on; - Indoor temperature : 20°C DB, 15°C WB - Outdoor temperature : 7°C DB, 6°C WB, Equivalent refrigerant piping : 7.5m, Level differences : 0m *4) Sound pressure was acquired in an anechoic room. Thus actual noise level may be different depending on the installation conditions. 112 9-2. Capacity tables 1) Cooling Model 056 Outdoor temperature (ºC, DB) 10 12 14 16 18 20 21 23 25 27 29 31 33 35 37 39 10 12 14 16 18 20 21 23 25 27 29 31 33 35 37 39 20 (ºC, DB) 14 (ºC, WB) TC SHC 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 3.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 23 (ºC, DB) 16 (ºC, WB) TC SHC 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 4.4 26 (ºC, DB) 18 (ºC, WB) TC SHC 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 3.7 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 5.3 6.7 6.7 6.7 6.7 6.7 6.7 6.7 6.7 6.7 6.7 6.7 6.7 6.7 6.7 6.7 6.7 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 5.6 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 7.1 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 28 (ºC, DB) 20 (ºC, WB) TC SHC 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 5.8 7.4 7.4 7.4 7.4 7.4 7.4 7.4 7.4 7.4 7.4 7.4 7.4 7.4 7.4 7.3 7.3 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.9 4.8 4.8 2) Heating Model 056 071 30 (ºC, DB) 22 (ºC, WB) TC SHC 6.3 6.3 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.2 6.1 6.1 8.0 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.9 7.8 7.7 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.7 3.7 4.9 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.8 4.7 4.6 32 (ºC, DB) 24 (ºC, WB) TC SHC 6.7 6.7 6.7 6.6 6.6 6.6 6.6 6.6 6.6 6.6 6.6 6.6 6.6 6.6 6.5 6.4 8.5 8.5 8.5 8.4 8.4 8.4 8.4 8.4 8.4 8.4 8.4 8.4 8.4 8.4 8.2 8.1 3.7 3.7 3.7 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.6 3.5 3.4 4.7 4.7 4.7 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.6 4.5 4.4 TC : Total Capacity(kW) Outdoor temperature (ºC) DB -20 -17 -15 -12 -10 -7 -5 -3 0 3 5 7 9 11 13 15 -20 -17 -15 -12 -10 -7 -5 -3 0 3 5 7 9 11 13 15 WB -21 -18 -16 -13 -11 -8 -6 -4 -1 2.2 4.1 6 7.9 9.8 12 14 -21 -18 -16 -13 -11 -8 -6 -4 -1 2.2 4.1 6 7.9 9.8 12 14 Indoor temperature (ºC, DB) 16.0 TC kW 3.9 4.0 4.2 4.4 4.6 4.9 5.2 5.4 5.7 5.9 6.2 6.5 6.7 6.9 7.1 7.3 4.9 5.1 5.3 5.6 5.9 6.2 6.5 6.9 7.2 7.6 7.9 8.2 8.5 8.7 9.0 9.2 18.0 TC kW 3.8 4.0 4.1 4.3 4.6 4.8 5.1 5.3 5.6 5.9 6.1 6.4 6.5 6.6 6.7 6.8 4.9 5.0 5.2 5.5 5.8 6.1 6.5 6.8 7.1 7.5 7.8 8.1 8.2 8.4 8.5 8.6 20.0 TC kW 3.8 3.9 4.0 4.2 4.5 4.8 5.0 5.3 5.5 5.8 6.0 6.3 6.3 6.3 6.3 6.3 4.8 4.9 5.1 5.4 5.7 6.0 6.4 6.7 7.0 7.3 7.7 8.0 8.0 8.0 8.0 8.0 22.0 TC kW 3.7 3.8 3.9 4.2 4.4 4.7 4.9 5.1 5.3 5.6 5.7 5.8 5.8 5.8 5.8 5.8 4.7 4.8 4.9 5.3 5.6 5.9 6.2 6.4 6.7 7.1 7.2 7.4 7.4 7.4 7.4 7.4 24.0 TC kW 3.7 3.8 3.8 4.1 4.4 4.5 4.7 4.9 5.0 5.3 5.3 5.3 5.3 5.3 5.3 5.3 4.7 4.8 4.8 5.2 5.6 5.8 6.0 6.2 6.4 6.8 6.8 6.8 6.8 6.8 6.8 6.8 113 Indoor units 071 TC : Total Capacity(kW), SHC : Sensible Heat Capacity(kW) Indoor temperature (ºC, WB) 27 (ºC, DB) 19 (ºC, WB) TC SHC 9 Ceiling 9-3. Dimensional drawing Unit:mm 6 5 3 4 2 No. Name Description 5.6kW 7.1kW 1 Liquid pipe connection Ø6.35 Flare 2 Gas pipe connection Drain pipe connection Conduit for power supply & communication wiring Air inlet grille Air outlet louver Ø12.70 Flare Ø15.88 Flare ID18 Hose 3 4 5 6 114 1 Ø9.52 Flare - 9 Ceiling 9-5. Sound pressure level 1) Operation sound level Unit : dB(A) 1m 1m Model High Low AM056FNCDEH✴✴✴ 40 1m 44 34 AM071FNCDEH✴✴✴ 40 1m Microphone Microphone  Note  These operation values were obtained in an anechoic room. Sound pressure level will vary depending on a range Microphone of factors such as the construction of the particular room where the equipment is installed.  Operation sound level may differ depending on operation and ambient conditions. 1m 1m 2) NC curves (2) AM071FNCDEH✴✴✴ 60 60 50 50 NC 45 40 NC 40 30 NC 35 HIGH NC 30 20 NC 25 LOW NC 20 NC 15 10 0 63 125 250 500 1000 2000 4000 Octave band center frequency(Hz) 116 8000 Sound pressure level (dB) Sound pressure level (dB) (1) AM056FNCDEH✴✴✴ NC 45 40 NC 40 30 NC 35 HIGH NC 30 20 NC 25 LOW NC 20 NC 15 10 0 63 125 250 500 1000 2000 4000 Octave band center frequency(Hz) 8000 9-6. Temperature and air flow distribution 1) AM071FNCDEH✴✴✴ (Floor installation) (1) Cooling air velocity distribution  Discharge angle : 36° Ceiling height 3m 0.2m/s 2m Indoor units 0.4m/s 1m 0.6m/s 0m 2m 1m 3m 5m 4m Floor distance 6m 7m (2) Cooling temperature distribution 8m  Discharge angle : 36° Ceiling height 3m 2m 25 24 22 23 21 1m 24 25 0m 2m 1m 3m 5m 4m Floor distance 6m (3) Heating air velocity distribution 7m 8m  Discharge angle : 54° 3m 0.6m/s 0.8m/s 0.6m/s 0.4m/s 1.0m/s Ceiling height 0.2m/s 0.4m/s 2m 0.2m/s 1.2m/s 1m 0m 2m 1m 3m 5m 4m Floor distance 6m (4) Heating temperature distribution 7m 8m  Discharge angle : 54° 3m 27 Ceiling height 29 2m 27 29 31 25 1m 23 21 0m 1m 2m 3m 5m 4m Floor distance 6m 7m 8m 117 9 Ceiling 9-6. Temperature and air flow distribution 2) AM071FNCDEH✴✴✴ (Ceiling installation) (1) Cooling air velocity distribution  Discharge angle : 36° 3m Ceiling height 1.0m/s 2m 0.2m/s 1m 0.4m/s 0.2m/s 0.6m/s 0m 2m 1m 5m 4m Floor distance 3m 6m (2) Cooling temperature distribution 7m 8m  Discharge angle : 36° 3m Ceiling height 25 2m 21 24 24 1m 23 23 0m 2m 1m 5m 4m Floor distance 3m 6m (3) Heating air velocity distribution 7m 8m  Discharge angle : 54° 3m Ceiling height 0.2m/s 2m 0.4m/s 1.0m/s 0.8m/s 1m 0.6m/s 0.4m/s 0.2m/s 0m 2m 1m 3m 5m 4m Floor distance 6m (4) Heating temperature distribution 7m 8m  Discharge angle : 54° 3m Ceiling height 25 2m 33 31 25 27 1m 23 21 21 0m 118 1m 2m 3m 5m 4m Floor distance 6m 7m 8m