Transcript
CellPipe™ IAD 4A and CellPipe™ IAD 8T Hardware Installation Guide
Part Number: 7820-0791-001 For software version 2.0 January 2001
Copyright © 2001 Lucent Technologies Inc. All rights reserved.
This material is protected by the copyright laws of the United States and other countries. It may not be reproduced, distributed, or altered in any fashion by any entity (either internal or external to Lucent Technologies), except in accordance with applicable agreements, contracts, or licensing, without the express written consent of Lucent Technologies. For permission to reproduce or distribute, please email your request to
[email protected]. Notice
Every effort was made to ensure that the information in this document was complete and accurate at the time of printing, but information is subject to change. Safety, Compliance, and Warranty Information
Before handling any Lucent Access Networks hardware product, read the Edge Access Safety and Compliance Guide included in your product package. See that guide also to determine how products comply with the electromagnetic interference (EMI) and network compatibility requirements of your country. See the warranty card included in your product package for the limited warranty that Lucent Technologies provides for its products. Security Statement
In rare instances, unauthorized individuals make connections to the telecommunications network through the use of access features. Copyrights for Third-Party Software Included in Lucent Access Networks Software Products
C++ Standard Template Library software copyright© 1994 Hewlett-Packard Company and copyright© 1997 Silicon Graphics. Permission to use, copy, modify, distribute, and sell this software and its documentation for any purpose is hereby granted without fee, provided that the above copyright notice appear in all copies and that both that copyright notice and this permission notice appear in supporting documentation. Neither Hewlett-Packard nor Silicon Graphics makes any representations about the suitability of this software for any purpose. It is provided “as is” without express or implied warranty. Berkeley Software Distribution (BSD) UNIX software copyright© 1982, 1986, 1988, 1993 The Regents of California. All rights reserved. Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: 1. Redistributions of source code must retain the above copyright notice, this list of conditions, and the following disclaimer. 2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions, and the following disclaimer in the documentation and/or other materials provided with the distribution. 3. All advertising materials mentioning features or use of this software must display the following acknowledgement: This product includes software developed by the University of California, Berkeley, and its contributors. 4. Neither the name of the University nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission. THIS SOFTWARE IS PROVIDED BY THE REGENTS AND CONTRIBUTORS “AS IS” AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Feedback
Lucent Technologies appreciates your comments, either positive or negative, about this manual. Please send them to
[email protected].
Lucent Technologies
Trademarks
Trademarks 4ESS, 5ESS, A Network of Expertise, AnyMedia, APX 8000, AqueView, AUDIX, B-STDX 8000, B-STDX 9000, ...Beyond Compare, CaseView, Cajun, CajunDocs, CAJUNVIEW, Callmaster, CallVisor, CBX 500, CellPipe, ChoiceNet, ClearReach, ComOS, cvMAX, DACScan, Dacsmate, Datakit, DEFINITY, Definity One, DSLMAX, DSL Terminator, DSLPipe, DSLTNT, Elemedia, Elemedia Enhanced, EMMI, End to End Solutions, EPAC, eSight, ESS, EVEREST, Gigabit-scaled campus networking, Globalview, GRF, GX 250, GX 550, HyperPATH, Inferno, InfernoSpaces, Intragy, IntragyAccess, IntragyCentral, Intuity, IP Navigator, IPWorX, LineReach, LinkReach, MAX, MAXENT, MAX TNT, Multiband, Multiband PLUS, Multiband RPM, MultiDSL, MultiVoice, MultiVPN, Navis, NavisAccess, NavisConnect, NavisCore, NavisRadius, NavisXtend, NetCare, NetLight, NetPartner, OneVision, Open Systems Innovations, OpenTrunk, P550, PacketStar, PathStar, Pinnacle, Pipeline, PMVision, PortMaster, SecureConnect, Selectools, Series56, SmoothConnect, Stinger, SYSTIMAX, True Access, WaveLAN, WaveMANAGER, WaveMODEM, WebXtend, and Where Network Solutions Never End are trademarks of Lucent Technologies Inc. Advantage Pak, Advantage Services, AnyMedia, ...Beyond Compare, End to End Solutions, Inter.NetWorking, MAXENT, and NetWork Knowledge Solutions are service marks of Lucent Technologies Inc. Other trademarks, service marks, and trade names mentioned in this publication belong to their respective owners.
Ordering Information You can order the most up-to-date product information and computer-based training online at http://www.lucent.com/ins/bookstore.
Customer Service To obtain product and service information, software upgrades, and technical assistance, visit the eSight™ Service Center at http://www.esight.com. The center is open 24 hours a day, seven days a week.
CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide
iii
Customer Service
Finding information and software The eSight Service Center at http://www.esight.com provides technical information, product information, and descriptions of available services. Log in and select a service. The eSight Service Center also provides software upgrades, release notes, and addenda. Or you can visit the FTP site at ftp://ftp.ascend.com for this information.
Obtaining technical assistance The eSight™ Service Center at http://www.esight.com provides access to technical support. You can obtain technical assistance through email or the Internet, or by telephone. If you need to contact Lucent Technologies for assistance, make sure that you have the following information available: •
Active contract number, product name, model, and serial number
•
Software version
•
Software and hardware options
•
If supplied by your carrier, service profile identifiers (SPIDs) associated with your line
•
Your local telephone company’s switch type and operating mode, such as AT&T 5ESS Custom or Northern Telecom National ISDN-1
•
Whether you are routing or bridging with your Lucent product
•
Type of computer you are using
•
Description of the problem
Obtaining assistance through email or the Internet If your services agreement allows, you can communicate directly with a technical engineer through Email Technical Support or eSight Live chat. Select one of these sites when you log in to http://www.esight.com.
Calling the technical assistance center (TAC) If you cannot find an answer through the tools and information on eSight or if you have a very urgent need, contact TAC. Access the eSight Service Center at iv
CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide
Important safety instructions
http://www.esight.com and click Contact Us below the Lucent Technologies logo for a list of telephone numbers inside and outside the United States. You can alternatively call (800) 272-3634 for a menu of Lucent services, or call (510) 769-6001 for an operator. If you do not have an active services agreement or contract, you will be charged for time and materials.
Important safety instructions 1
Read and follow all warning notices and instructions marked on the product or included in the manual.
2
There are no operator serviceable parts within the unit. Refer all servicing to trained service personnel.
3
Product installation should be performed by trained service personnel only.
4
Install only in restricted-access areas in accordance with UL1950, C22.2 No. 950, and IEC60950
5
The maximum recommended operating ambient is 122° F (50° C). Allow sufficient air circulation or space between units when installed in a closed or multiple-rack assembly.
6
Slots and openings in the cabinet are provided for ventilation. To ensure reliable operation of the product and to protect it from overheating, these slots and openings must not be blocked or covered. Installation without sufficient airflow can be unsafe.
7
Equipment mounted in a rack should be distributed to prevent a possible hazardous condition due to uneven loading. The rack should safely support the combined weight of all equipment. This product weighs 8 lbs.
8
The power source has to be adequately rated to assure safe operation of the equipment. The building installation and/or power source must provide overload protection.
9
Protective earth (PE) connection is essential to ensure safe operation before connecting to the power supply and telecommunication network. Do not defeat the purpose of the grounding-type plug by modifying the plug or using an adapter. Use an outlet tester or a voltmeter to check the ac receptacle for the presence of earth ground. If the receptacle is not properly grounded, the
CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide
v
Important safety instructions
installation must not proceed until a qualified electrician has corrected the problem. If the power supply is fed from a power source with no protective-earthing path (such as in certain Nordic countries), connect an earth-grounded copper wire to the dedicated wiring terminal marked with (PE symbol) on the chassis. The minimum size of the wire for a Pipeline unit with rated input current not exceeding 6A is AWG 18 and cross-sectional area 0.75 mm2. Models with ac power inputs are intended for use with a single-phase three-wire power cord (which includes earthing conductor). For models with dc power inputs, the protective earth connection must be established by using the dedicated earthing terminal marked with the PE symbol or, if provided, the earthing pin of the input terminal block. 10 Models with dc power inputs must be connected to a -48V dc supply source that is electrically isolated from the ac source in accordance with UL1950, C22.2 No. 950, and IEC60950. 11 For products installed in Nordic countries (except Central Office equipment), a type B plug or permanent connection must be used for connections to the main power supply. 12 Before installing wires to the dc power terminal block, verify that these wires are not connected to any power source. Installing live wires (that is, wires connected to a power source) is hazardous. 13 Do not allow anything to rest on the power cord, and do not locate the product where people will walk on the power cord. 14 Do not attempt to service this product yourself. Opening or removing covers can expose you to dangerous high voltage points or other risks. Refer all servicing to qualified service personnel. 15 General purpose cables are provided with this product. Special cables, which might be required by the regulatory inspection authority for the installation site, are the responsibility of the customer. 16 When installed in the final configuration, the product must comply with the applicable safety standards and regulatory requirements of the country in which it is installed. If necessary, consult with the appropriate regulatory agencies and inspection authorities to ensure compliance. 17 A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings. If products installed in separate buildings are interconnected, the voltage potential might cause a hazardous condition. Consult vi
CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide
Important safety instructions
a qualified electrical consultant to determine whether or not this phenomenon exists. In addition, if the equipment is to be used with telecommunications circuits, take the following precautions: •
Never install telephone wiring during a lightning storm.
•
Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.
•
Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface.
•
Use caution when installing or modifying telephone lines.
•
Avoid using equipment connected to telephone lines (other than a cordless telephone) during an electrical storm. There is a remote risk of electric shock from lightning.
•
Do not use a telephone or other equipment connected to telephone lines to report a gas leak in the vicinity of the leak.
!
Warning: To reduce the risk of fire, communication cable conductors must be 26 AWG (0.13 mm2) or larger.
!
Avertissement: Afin de réduire les risques d'incendie, les fils conducteurs du câble de communication doivent être d'un calibre minimum de 26 AWG (American Wire Gauge), c'est-à-dire d'un minimum de 0,13 mm².
!
Warnung: Um Feuer-Risiko zu reduzieren, müsssen die Querschnitte der Kommunikationskabel-Leiter 0,13 mm² oder größer sein.
CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide
vii
Contents Trademarks .............................................................................................................. iii Ordering Information ............................................................................................... iii Customer Service ..................................................................................................... iii Important safety instructions ..................................................................................... v
Introduction ............................................................................. 1 New CellPipe products .............................................................................................. Lucent TURN-UP ...................................................................................................... Serial connection ....................................................................................................... Configuring your communications software ............................................................. Preparing to upgrade .................................................................................................. Locating the software binary file(s) ......................................................................... Power supply .............................................................................................................
1 2 2 2 3 3 4
CellPipe IAD 4A ....................................................................... 5 Connecting a CellPipe IAD 4A unit .......................................................................... 5 Checking the activity of CellPipe IAD 4A status lights ............................................ 6 Configuring a CellPipe IAD 4A unit ......................................................................... 8
CellPipe IAD 8T ....................................................................... 9 Connecting a CellPipe IAD 8T unit .......................................................................... 9 Checking the activity of CellPipe IAD 8T status lights .......................................... 10 Configuring a CellPipe IAD 8T unit ....................................................................... 12
Connector Pinouts ................................................................ 15 TERMINAL pinouts ................................................................................................ 15
CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide
ix
Contents
10/100 LAN connector pinouts ............................................................................... 15 T1 Connector pinouts .............................................................................................. 16 ADSL connector pinouts ......................................................................................... 16
FCC Regulations .................................................................. 17 FCC Part 15 Notice .................................................................................................. 17 IC CS-03 Notice ...................................................................................................... 18
x
CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide
Introduction
New CellPipe products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Lucent TURN-UP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Serial connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Configuring your communications software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Preparing to upgrade. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Locating the software binary file(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
New CellPipe products The CellPipe IAD 4A and CellPipe IAD 8T are now part of the CellPipe™ product line that run the IAD (Integrated Access Device) v. 2.0 software. These are integrated access devices supporting both voice and data communications. This Hardware Installation Guide provides information for connecting these new units to your computer. For additional information, refer to the CellPipe™ IAD User’s Guide.
CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide
1
Introduction Lucent TURN-UP
Lucent TURN-UP The CellPipe IAD 4A and CellPipe IAD 8T units support the Lucent TURN-UP automated provisioning system. TURN-Up is enabled when a user powers up his unit, which is then automatically configured via the configuration server located at his Internet Service Provider (ISP). TURN-UP eliminates the need for user configuration of units and provides centralized management of configuration information.
!
Caution: If you attempt to manually configure the unit, a Delete Management Port message will appear. If you select this option, the Lucent TURN-UP feature will be disabled to enable you to reconfigure the unit.
Serial connection You need to establish a serial connection to upgrade software and manually configure the CellPipe units. Connect a serial cable (a serial communication cable designed for connecting an external device) from your computer to the CellPipe unit. The cable must be a high-speed cable that supports the hardware handshaking technique used by almost all recently manufactured modems. The cable must have the appropriate connector for connection to a serial communication port on your computer and a DB-9 connector for connection to the TERMINAL port on the CellPipe unit.
Configuring your communications software Use a communications program (such as HyperTerm, PROCOMM PLUS, Zterm, or any other program that supports VT100 terminal emulation) to open a session directly with the port to which the IAD unit is connected. Configure your communications software with the following settings. If you are not already familiar with the settings listed, see the documentation that accompanies your communications software. If you are using the software for the first time, going through an online or printed tutorial is a good way to get started. •
2
Direct connection—Indicate that a serial cable connects the IAD directly to the computer. CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide
Introduction Preparing to upgrade
•
Serial port—Specify which of the computer’s serial ports the software uses. If the only serial port available is currently used by an internal modem, you may need to use your computer’s setup software to specify an external connector for the port that will be used in place of the internal modem. In some cases, you also may need to remove the modem. See the manual for the modem and your computer’s user manual for details.
•
Terminal type—Specify VT100.
•
Duplex—Most communications software support full-duplex transmission by default. If given a choice, set Full duplex.
•
Bits per second—Specify 9600.
•
Data bits—Specify 8.
•
Parity—Specify None.
•
Stop bits—Specify 1.
•
Flow control—Disable software flow control (XON/XOFF) and, if possible, hardware flow control (RTS/CTS).
When you establish the connection, the command-line interface appears.
Preparing to upgrade Set up a TFTP server on the network that is accessible by your CellPipe unit prior to upgrading the software. Also, configure an IP address on the 10BaseT port of the CellPipe unit and test the connection to the TFTP server by pinging the server.
Locating the software binary file(s) !
Caution: Do not upgrade to an earlier software version. Uploading older software causes the unit to loose configuration, and you will have to return it for replacement.
You can locate the software binary file (or collection of software binary files) for the IAD CellPipes at ftp://ftp.ascend.com/pub/Software-Releases/CellPipe. CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide
3
Introduction Power supply
The software loads for each CellPipe unit are different. Make certain that you download the correct file. If you use the wrong file to upgrade, your unit will stop functioning and you will have to restore your configuration from a backup. Extract and save the appropriate file to the TFTP boot directory from which you will upgrade your unit.
Power supply All CellPipe units are shipped with a power supply. However, European users need to purchase an additional wall outlet cable due to the regional variations in wall outlets. Please check with your Sales Representative for the power supply and cables required for your environment. Refer to the illustrations below.
Domestic power supply
4
European power supply
CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide
CellPipe IAD 4A
Connecting a CellPipe IAD 4A unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Checking the activity of CellPipe IAD 4A status lights. . . . . . . . . . . . . . . . . . . . . . 6 Configuring a CellPipe IAD 4A unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
The CellPipe IAD 4A supports four POTS (plain old telephone service) lines over ATM (Asynchronous Transfer Mode), PPP (Point-to-Point Protocol) over ATM, Frame Relay or HDLC (High-Level Data Link Control) over an ADSL (asymmetrical digital subscriber line) WAN interface. This unit supports asymmetrical transmission and receive downstream rates of 64 Kbps to 8.1 Mbps and upstream rates of 64 Kbps to 800 Kbps.
Connecting a CellPipe IAD 4A unit The CellPipe IAD box you receive contains the following items: 1
CellPipe IAD unit
2
10BaseT Ethernet crossover cable (yellow)
3
ADSL WAN cable with RJ-11 modular plug connectors (blue)
4
Power supply
5
CellPipe™ IAD User’s Guide
6
Hardware Installation Guide
CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide
5
CellPipe IAD 4A Checking the activity of CellPipe IAD 4A status lights
7
Warranty card
To connect to the CellPipe IAD 4A unit, proceed as follows: 1
Connect one end of the yellow Ethernet cable to the port labeled LAN on your unit and the other end to the Ethernet adapter on your computer. Note: To connect the CellPipe unit to an Ethernet hub, use a straight-through Ethernet cable (not supplied).
2
Connect one end of the blue WAN cable to the port labeled WAN and plug the other end into the wall jack.
3
Connect up to four telephone lines to the four POTS ports.
4
Connect the power cable to your unit.
5
Plug the other end of the power cable into a wall outlet.
Note: The unit has no power switch and connecting the power cable turns on the CellPipe IAD unit.
Checking the activity of CellPipe IAD 4A status lights Observe the activity pattern of the lights on the front of the CellPipe IAD 4A unit to verify that the unit is connected properly.
6
CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide
CellPipe IAD 4A Checking the activity of CellPipe IAD 4A status lights
When all the cables are connected, verify that the following status light behavior takes place: •
The pwr light is on initially and remains on. If not on, make sure the power supply is properly connected.
•
The act light blinks during any LAN traffic. Otherwise, it remains off.
•
The lnk light is on if an Ethernet connection is established. If not on, check to make sure your Ethernet cable is properly connected.
•
The wan light blinks until a DSL connection is established, and then it remains on.
•
The con light is on only during the CellPipe IAD unit self-test and blinks when a voice port is offhook.
CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide
7
CellPipe IAD 4A Configuring a CellPipe IAD 4A unit
Configuring a CellPipe IAD 4A unit !
Caution: If you attempt to manually configure the unit, a Delete Management Port message appears. The unit disables Lucent TURN-UP to enable you to manually configure the unit.
The Main menu items for the CellPipe IAD 4A unit are similar to those of other IAD CellPipe units. Refer to the CellPipe™ IAD User’s Guide for a discussion of the Main menu items. The menu exception for the CellPipe IAD 4A can be found in its Configure WAN menu. To configure the WAN interface on the CellPipe IAD 4A unit, proceed as follows: 1
Select Configure WAN from the Main Menu.
2
Select Configure Physical Interface under the WAN Configuration menu.
3
Set the ADSL Standard. See Table 1.
.
Table 1.
ADSL ATU-R configuration menu
Menu option
Description
Set ADSL Standard
Current ADSL Standard: T1.413 Choose an ADSL Standard: 1. T1.413 2. G.Lite 3. G.DMT 4. Alcatel 1.4 5. Multi-Mode 6. ADI 7. Alcatel
8
CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide
CellPipe IAD 8T
Connecting a CellPipe IAD 8T unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Checking the activity of CellPipe IAD 8T status lights . . . . . . . . . . . . . . . . . . . . . 10 Configuring a CellPipe IAD 8T unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
The CellPipe IAD 8T supports eight POTS lines over ATM, PPP over ATM, Frame Relay or HDLC (High-Level Data Link Control) over a T1 WAN interface. This voice-over-T1 solution supports symmetrical transmission and receive rates of 1.544 Mbps.
Connecting a CellPipe IAD 8T unit The CellPipe IAD box you receive contains the following items: 1
CellPipe IAD unit
2
10BaseT Ethernet crossover cable (yellow)
3
T1 WAN cable (blue)
4
Power supply
5
CellPipe™ IAD User’s Guide
6
Hardware Installation Guide
CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide
9
CellPipe IAD 8T Checking the activity of CellPipe IAD 8T status lights
7
Warranty card
To connect to the CellPipe IAD 8T unit, proceed as follows: 1
Connect one end of the yellow Ethernet cable to the port labeled LAN on your unit and the other end to the Ethernet adapter on your computer. Note: To connect the CellPipe unit to an Ethernet hub, use a straight-through Ethernet cable (not supplied).
2
Connect one end of the blue WAN cable to the port labeled WAN and plug the other end into the wall jack.
3
Connect up to eight telephone lines to the eight POTS ports.
4
Connect the power cable to your unit.
5
Plug the other end of the power cable into a wall outlet.
Note: The unit has no power switch and connecting the power cable turns on the CellPipe IAD unit.
Checking the activity of CellPipe IAD 8T status lights Observe the activity pattern of the lights on the front of the CellPipe IAD 8T unit to verify that the unit is connected properly.
10
CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide
CellPipe IAD 8T Checking the activity of CellPipe IAD 8T status lights
When all the cables are connected, verify the following status light behavior takes place: •
The pwr light is on initially and remains on. If not on, make sure the power supply is properly connected.
•
The lan lnk light is on if an Ethernet connection is established. If not on, check to make sure your Ethernet cable is properly connected.
•
The lan act light blinks during any LAN traffic. Otherwise, it remains off.
•
The wan lnk light blinks until a connection is established, and then it remains on.
•
The voice light is on only when a voice port is offhook.
CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide
11
CellPipe IAD 8T Configuring a CellPipe IAD 8T unit
Configuring a CellPipe IAD 8T unit !
Caution: If you attempt to manually configure the unit, a Delete Management Port message appears. The unit disables Lucent TURN-UP to enable you to manually configure the unit.
The Main menu items for the CellPipe IAD 8T unit are similar to those of other IAD CellPipe units. Refer to the CellPipe™ IAD User’s Guide for a discussion of the Main menu items. The menu exception for the CellPipe IAD 8T can be found in its Configure WAN menu. To configure the WAN interface on the CellPipe IAD 8T unit, proceed as follows: 1
Select Configure WAN from the Main Menu.
2
Select Configure Physical Interface under the WAN Configuration menu.
3
Set the desired frame mode.
4
Proceed with the remaining configurations. See Table 2.
Table 2.
12
T1 Configuration menu
Menu option
Description
Select Frame Mode
Choose between ESF (T1) Frame Mode or D4 Frame Mode.
CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide
CellPipe IAD 8T Configuring a CellPipe IAD 8T unit
Table 2.
T1 Configuration menu (continued)
Menu option
Description
Select Line Build
Displays the Select Line Build Out submenu, which contains the following commands that set compensation for signal or line loss during the T1 connection. Check with your service provider for the appropriate signal loss (dB). –
1. 0 to 133 Feet (0 dB)
–
2. 133 to 266 Feet
–
3. 266 to 399 Feet
–
4. 399 to 533 Feet
–
5. 533 to 655 Feet
–
6.0 – 7.5 dB
–
7.0 – 15 dB
–
8. 0 – 22.5 dB
Enable/Disable B8ZS
Enables and disables bipolar 8-zero substitution (B8ZS) line code.
Configure Transmit Channels
Allows you to set the number of transmission channels (maximum 24) for the WAN interface.
Configure Receive Channels
Allows you to set the number of receive channels (maximum 24) for the WAN interface.
Configure Clock Source
Choose the Internal or External Clock Source.
Change to E1 Mode
Currently not supported.
CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide
13
Connector Pinouts TERMINAL pinouts Pin
Signal
1
GND
2
Tx Data
3
Rx Data
10/100 LAN connector pinouts Pin
Signal
1
Tx
2
Tx
3
Rx
4
NC
5
NC
6
Rx
7
NC
8
NC
CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide
15
Connector Pinouts T1 Connector pinouts
T1 Connector pinouts Pin
Signal
1
Rx Ring
2
Rx Tip
3
NC
4
Tx Tip
5
Tx Ring
6
NC
7
NC
8
NC
ADSL connector pinouts Pin
Signal
1
NC
2
NC
3
Tip
4
Ring
5
NC
6
NC
16
CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide
FCC Regulations FCC Part 15 Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 IC CS-03 Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
FCC Part 15 Notice !
Warning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential environment. This equipment generates, uses, and can radiate radio frequency energy, and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is unlikely to cause harmful interference. But if it does, the user will be required to correct the interference at his or her own expense. The authority to operate this equipment is conditioned by the requirement that no modifications will be made to the equipment unless the changes or modifications are expressly approved by Lucent Technologies.
CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide
17
FCC Regulations IC CS-03 Notice
IC CS-03 Notice The Industry Canada label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational, and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document(s). The Department does not guarantee that the equipment will operate to the user’s satisfaction. Before installing this equipment, users should make sure that it is permissible to be connected to the facilities of the local telecommunications company. An acceptable method of connection must be used to install the equipment. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certified equipment should be coordinated by a representative designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines, and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. Warning: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate.
18
CellPipe IAD 4A and CellPipe IAD 8T Hardware Installation Guide