Preview only show first 10 pages with watermark. For full document please download

Cem3 Data Terminations Guide

   EMBED


Share

Transcript

ETC® Setup Guide Sensor ®3 CEM3 Data Terminations Guide I n t r o d u c ti o n This guide provides information for terminating the low-voltage data wiring required for a Sensor®3 rack with CEM3 control. Terminating the data wiring requires that you work inside the rack with all of the modules removed and in close proximity to the high voltage bus bars. All power must be turned off before working in the rack. WARNING: RISK OF ELECTRIC SHOCK! Failure to disconnect all power to the rack before working in the rack could result in serious injury or death. Ref erenced E T C Ter minat ion Kit s ETC Part # Description 4100A1012 DMX Preparation Kit (w/ Screw Connector) 4100A1013 DMX Preparation Kit (w/ IDC Connector) 4101A2003 ETC Ethernet Termination Kit Te r m i n a t i o n s The CEM3 backplane uses the same terminal strip connectors and termination kits as ETC’s DMX wall plate. Wire preparation will vary with the type of wire and termination kit being used. Please refer to the instructions included with the kit for specific information on wire preparation. Ethernet Network Termination - RJ45 Connector Step 1: Note: Step 2: Step 3: Follow the directions provided in the Ethernet Termination Kit to terminate the incoming Ethernet cable in the RJ45 UTP connector in the surface mounting box. The kit is included with the dimmer rack door (along with this guide) except the SR3-6, where it is shipped inside the rack. Use the instructions provided with the kit for proper Category 5 cable termination. Install the surface mount box inside the rack with double-sided tape, • SR3-48: to the rear wall of the rack interior behind the CEM3 backplane • SR3-6, SR3-12, and SR3-24: to the bottom of the rack interior, behind the backplane Use the provided male-to-male Ethernet patch cable to connect the surface mounting box female RJ45 connector to the female RJ45 connector on the CEM3 backplane. Corporate Headquarters  3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA  Tel +608 831 4116  Fax +608 836 1736 London, UK  Unit 26-28, Victoria Industrial Estate, Victoria Road, London W3 6UU, UK  Tel +44 (0)20 8896 1000  Fax +44 (0)20 8896 2000 Rome, IT  Via Pieve Torina, 48, 00156 Rome, Italy  Tel +39 (06) 32 111 683  Fax +39 (06) 32 656 990 Holzkirchen, DE  Ohmstrasse 3, 83607 Holzkirchen, Germany  Tel +49 (80 24) 47 00-0  Fax +49 (80 24) 47 00-3 00 Hong Kong  Rm 1801, 18/F, Tower I Phase 1 Enterprise Square, 9 Sheung Yuet Road, Kowloon Bay, Kowloon, Hong Kong  Tel +852 2799 1220  Fax +852 2799 9325 Service: (Americas) [email protected]  (UK) [email protected]  (DE) [email protected]  (Asia) [email protected] Web: www.etcconnect.com  QSF 4.1.9.1  Copyright © 2016 ETC. All Rights Reserved.  Product information and specifications subject to change. 7141M2200  Rev D  Released 2016-02 Sens or 3 CEM3 Te r min at i ons Gu id e Pa ge 1 of 2 El ect r on ic T he at r e Con tr o ls, I nc. Setup Guide: Sensor3 CEM3 Data Terminations Guide DMX Input Termination Below is the DMX termination layout for two different styles of connectors. At top is the layout for screw-terminal connectors that are intended for use with Belden 9729 cable or equivalent cable type. Cable other than Belden 9729 may have a different color code for its wire pairs. The lower portion illustrates the layout for IDC connectors that are intended for use with Category 5 solid core cable (or equivalent/better cable types) 1 2 3 4 5 6 7 8 Turn on DMX termination in the last rack that is physically connected in the DMX chain. If daisy-chaining to another rack or DMX device... COM Data - (Black) Data + (Red) From source DMX A n/c n/c n/c n/c COM n/c Data - (Black) n/c n/c n/c n/c If daisy-chaining to another rack or DMX device... 1 2 3 4 5 6 7 8 n/c Data + (Red) From source DMX B When using IDC Connectors From source DMX B From source DMX A ORG W/BRN COM Data - GRN BRN Data + W/ORG W/GRN BLU W/BLU W/BRN ORG Data - W/GRN BLU GRN BRN Data + W/ORG COM 1 2 3 4 5 6 7 8 W/BLU To Sensor3 compatible stations To external indicators (such as a lamp or relay) +24Vdc (max 25mA each) 1 2 3 4 5 6 7 8 To external indicators (such as a lamp or relay) +24Vdc (max 25mA each) ORG W/BRN COM DMX A Thru Data - COM W/BRN Data + W/ORG ORG DMX B Thru Data - n/c Data + W/ORG n/c If daisy-chaining to another rack or DMX device... To trigger Panic, use a Maintained Closure Please see this job’s prints for wiring specifics of these terminations. For Panic SEND/RTN: NO - Normally Open closure Disabled - Panic Disabled NC - Normally Closed closure 1 2 3 4 5 6 7 8 Sens or 3 CEM3 Te r min at i ons Gu id e Pa ge 2 of 2 El ect r on ic T he at r e Con tr o ls, I nc.