Centripro_duplex_nema1_indoor_panel_tech_brochure

   EMBED


Share

Transcript

TECHNICAL BROCHURE BCP2 R6 DUPLEX NEMA1 INDOOR PANEL D10020N1 SINGLE PHASE CONTROL PANEL CentriPro Wastewater APPLICATIONS FEATURES Superior quality duplex liquid level controller, automatic alternation for two pump operation. High level alarm warning designed for a variety of sump, effluent, sewage and water transfer applications. Not for use in damp, outdoor or weatherproof applications. • Provides fully automatic operation for two pumps. SPECIFICATIONS • Non-modifiable — No options available. • Accepts single or dual power feed. • Two hand-off-automatic (H-O-A) pump switches. • On-off control circuit switch. Alternates pump starting to distribute operating time. Provides extra pumping capacity in times of high inflow by energizing both pumps. • Solid state pump alternator circuit with float status lights for ease of installation or trouble shooting. • Alternator selector switch allows a choice of automatic alternation or operation of only pump 1 or pump 2. Typically used if one pump is down for maintenance. • Lag pump start delay built-in. • Numbered terminal strip-screw type. • High level alarm circuit includes through door mounted silence switch for manual silence of alarm horn. • NEMA 1, 30 watt, flashing red light. • Two through door mounted pump run lights. • NEMA 1, steel enclosure. • Top mounted high intensity flashing red light provides 360° visibility. • Two oversized magnetic contactors. • NEMA 1, alarm horn – 95db. • Pulsating, corrosion proof alarm horn. • Auxiliary alarm contacts. • Auxiliary alarm contacts provided for remote alarm connection. • Alternator selector switch • Lag pump start delay Single Phase • Lag pump start delay built-in. Delays starting lag pump for 5 seconds if both pumps attempt to start simultaneously as after a power outage. • Field adjustable for 115 or 230 V, 60 Hz. • Color coded wiring, screw type terminals and plug • Two pump 25 amp circuit breakers. in sockets, insure ease of field servicing. • Enclosure: 12.3" W x 14.3" H x 6" D. • Field wiring diagram, panel schematic and installa- NOTE: Enclosure dimensions do not include 3" high light. • Factory wired for operation with three float switches. PANEL MODEL INFORMATION • Panel can be wired for a single power feed for ORDER NUMBER D10020N1 Panel is non-modifiable. AMP RANGE 0-20 tion instructions included. An easy field modification for four float switch operation using separate “lag-on” and “alarm switches” is provided. pumps and control circuit or the control circuit can be wired to a separate power supply to insure alarm integrity in case of a tripped main breaker. • Float Switches – Note: Please order float switches separately. Requires three narrow angle switches or optional fourth float for lag pump. • Entire unit is UL and CUL listed. PAGE 2 CentriPro Wastewater 25 A S1 1 FOR 120 VOLT OPERATION USE TERMINALS (L1) AND (N) JUMP TERMINALS (N) AND (L2) 2 S2 25 A L1 230 VAC SINGLE PHASE 60 Hz PUMP NO. 1 1T 1 2T PUMP NO. 2 2 L2 WHITE N GND CONTROL ON-OFF RUN A 230 VOLT SYSTEM REQUIRES A 4 WIRE POWER SUPPLY LINE L1, L2, N AND GND. WITHOUT A NEUTRAL THE CONTROL CIRCUIT WILL NOT WORK. HAND BLACK OFF YELLOW PURPLE S1 AUTO RUN HAND BLACK OFF ORANGE BLUE S2 AUTO RED R1 ➀ FOR SEPARATE 120 VAC CONTROL POWER SUPPLY, REMOVE JUMPER (J1) FROM TERMINALS (H) AND (L1). CONNECT 15 AMP MAX. PROTECTED 120 VAC SUPPLY TO TERMINALS (L1) AND (N). WITH THE NEUTRAL OF THE SUPPLY TO (N). ➁ FOR USE WITH WIDE ANGLE FLOAT SWITCH (ONE FLOAT FOR BOTH ON AND OFF OPERATION). JUMP TERMINALS (3) AND (4), INSTALL WIDE ANGLE FLOAT TO TERMINALS (1) AND (2). TEST PUMP 1 ALT PUMP 2 TEST SILENCE R2 MUTE C RESET OFF RED LEAD LAG YEL YELLOW RESET BRW BROWN ALARM FLASHING L1 N H L1 N PINK SONALERT 1 2 3 4 5 6 7 8 9 10 FLASH RED WHITE HORN 11 R1 BLACK R2 Power and Pump Wiring Terminals DRY CONTACTS J1➀ J2 C ALARM FLOAT ③ FACTORY WIRED FOR (3) FLOAT OPERATION. FOR (4) FLOAT OPERATION, REMOVE JUMPER (J2) FROM TERMNALS (6) AND (8). INSTALL LAG FLOAT ON TERMINALS (5) AND (6). L1 LAG FLOAT (OPTIONAL)③ L2 N 1 2 1T 1 2 L1 2T H LEAD FLOAT OFF FLOAT➁ J1➀ 120/230 VAC ➁ SINGLE PHASE 60 Hz PUMP NO. 1 PUMP NO. 2 PAGE 3 L1 D10020N1 COMPONENTS 1. NEMA 1 enclosure 8. H-O-A selector switches 2. Flashing alarm light 9. Alarm reset selector switch 3. Alarm horn 10. Contactors 4. Pump run lights 11. Terminal strip 5. Horn on/off selector switch 12. Terminal strip 6. Alarm test selector switch 13. Control board 7. Control power on/off selector switch 14. Motor circuit breakers 2 4 8 4 8 9 5 6 7 3 14 14 13 10 11 10 12 1 Xylem, Inc. 2881 East Bayard Street Ext., Suite A Seneca Falls, NY 13148 Phone: (866) 325-4210 Fax: (888) 322-5877 www.xyleminc.com/brands/centripro CentriPro is a trademark of Xylem Inc. or one of its subsidiaries. © 2012 Xylem, Inc. BCP2 R6 April 2012