Preview only show first 10 pages with watermark. For full document please download

Cereport R2m2

   EMBED


Share

Transcript

Shenzhen BST Technology Co., Ltd. Reprt No. BTRE0804071110 EMC TEST REPORT For FINGERTEC WORLDWIDE SDN BHD FINGERPRINT Model: R2/M2 Prepared For : FINGERTEC WORLDWIDE SDN BHD NO.6, 8 & 10, JALAN BK 3/2, BANDAR KINRARA, 47100 PUCHONG, SELANGOR Prepared By : Shenzhen BST Technology Co., Ltd. 3F,Weames Technology Building,No. 10 Kefa Road, Science Park,Nanshan District,Shenzhen,Guangdong,China Date of Test : Date of Report : Report Number: Apr.07-08,2008 Apr.09,2008 BTRE0804071110 Page 1 of 27 Shenzhen BST Technology Co., Ltd. Reprt No. BTRE0804071110 TABLE OF CONTENT Description Test Report Declaration Page 1. GENERAL INFORMATION.................................................................................................. 4 1.1. 1.2. 1.3. Description of Device (EUT)............................................................................................................4 Test Facility ......................................................................................................................................4 Test Uncertainty................................................................................................................................4 2. TEST INSTRUMENT USED .................................................................................................. 5 2.1. 2.2. 2.3. 2.4. For Electrostatic Discharge Immunity Test ......................................................................................5 For RF Strength Susceptibility Test..................................................................................................5 For Radiated Emission Measurement ...............................................................................................5 For Conducted Emission Test...........................................................................................................5 3. POWER LINE CONDUCTED EMISSION TEST ............................................................... 6 3.1. 3.2. 3.3. 3.4. 3.5. 3.6. 3.7. Block Diagram of Test Setup............................................................................................................6 Test Standard ....................................................................................................................................6 Power Line Conducted Emission Limit ............................................................................................6 EUT Configuration on Test ..............................................................................................................6 Operating Condition of EUT ............................................................................................................6 Test Procedure ..................................................................................................................................7 Power Line Conducted Emission Test Results .................................................................................8 4. RADIATED EMISSION TEST............................................................................................... 9 4.1. 4.2. 4.3. 4.4. 4.5. 4.6. 4.7. Block Diagram of Test Setup............................................................................................................9 Test Standard ....................................................................................................................................9 Radiated Emission Limit ..................................................................................................................9 EUT Configuration on Test ............................................................................................................10 Operating Condition of EUT ..........................................................................................................10 Test Procedure ................................................................................................................................10 Radiated Emission Test Results......................................................................................................11 5. ELECTROSTATIC DISCHARGE TEST ........................................................................... 12 5.1. 5.2. 5.3. 5.4. 5.5. 5.6. 5.7. Block Diagram of Test Setup..........................................................................................................12 Test Standard ..................................................................................................................................12 Severity Levels and Performance Criterion ....................................................................................12 EUT Configuration on Test ............................................................................................................12 Operating Condition of EUT ..........................................................................................................13 Test Procedure ................................................................................................................................13 Test Results.....................................................................................................................................13 6. RF FIELD STRENGTH SUSCEPTIBILITY TEST........................................................... 15 6.1. Block Diagram of Test Setup..........................................................................................................15 6.2. Test Standard ..................................................................................................................................15 6.3. Severity Levels and Performance Criterion ....................................................................................16 6.4. EUT Configuration on Test ............................................................................................................16 6.5. Operating Condition of EUT ..........................................................................................................16 8.7. Test Results........................................................................................................................................16 APPENDIX I APPENDIX II Page 2 of 27 Shenzhen BST Technology Co., Ltd. Reprt No. BTRE0804071110 TEST REPORT DECLARATION Applicant : Manufacturer : EUT Description : FINGERTEC WORLDWIDE SDN BHD FINGERTEC WORLDWIDE LIMITED FINGERPRINT (A) MODEL NO. : R2/M2 (B) Remark : N/A Test Procedure Used: EN55022:1998+A1:2000+A2:2003 EN55024:1998+A1:2001+A2:2003 (EN61000-4-2:1995+A1:1998+A2:2001, EN61000-4-3:2002,EN61000-4-4:1995+A1:2001 EN61000-4-5: 1995+A1:2001,EN61000-4-6: 1996+A1:2001 EN61000-4-8: 1996+A1:2001) The device described above is tested by US to determine the maximum emission levels emanating from the device, the severe levels which the device can endure and EUT’s performance criterion. The test results are contained in this test report. Shenzhen BST Technology Co., Ltd. is assumed of full responsibility for the accuracy and completeness of these tests. Also, this report shows that the EUT is technically compliant with the EN55022, EN55024 standards. This report applies to above tested sample only and shall not be reproduced in part without written approval of Shenzhen BST Technology Co., Ltd. Date of Test : Apr.07-08,2008 Prepared by : Jack Li / Assistant Reviewer : Mary Du / Supervisor Approved & Authorized Signer : Christina / Manager Page 3 of 27 Shenzhen BST Technology Co., Ltd. Reprt No. BTRE0804071110 1. GENERAL INFORMATION 1.1. Description of Device (EUT) Description : FINGERPRINT Model Number : Applicant : FINGERTEC WORLDWIDE SDN BHD NO.6, 8 & 10, JALAN BK 3/2, BANDAR KINRARA, 47100 PUCHONG, SELANGOR Manufacturer : FINGERTEC WORLDWIDE LIMITED Peking University Founder Shiyan Science Park, Bao’an, Shezhen, China. 518108 Date of Test : Apr.07-08,2008 R2/M2 1.2. Test Facility Site Description EMC Lab. : Certificated by TUV,TIMCO Name of Firm : Shenzhen BST Technology Co., Ltd. Site Location : 3F,Weames Technology Building, No. 10 Kefa Road,Science Park, Nanshan District,Shenzhen,Guangdong,China 1.3. Test Uncertainty Conducted Emission Uncertainty = ±2.66dB Radiated Emission Uncertainty ±4.26dB = Page 4 of 27 Shenzhen BST Technology Co., Ltd. Reprt No. BTRE0804071110 2. TEST INSTRUMENT USED 2.1. For Electrostatic Discharge Immunity Test Item Equipment 1. ESD Tester Manufacturer HAEFELY Model No. PSD 1600 Serial No. H911’292 Last Cal. Jun. 02, 07 Cal. Interval 1 Year 2.2. For RF Strength Susceptibility Test Item 1. 2. 3. 4. 5. 6. 7. 8. Equipment Signal Generator Amplifier Amplifier Isotropic Field Monitor Isotropic Field Probe Biconic Antenna Log-periodic Antenna PC Manufacturer HP A&R A&R A&R A&R EMCO A&R N/A Model No. 8648A 500A100 100W/1000M1 FM2000 FP2000 3108 AT1080 486DX2 Serial No. 3633A02081 17034 17028 16829 16755 9507-2534 16812 N/A Last Cal. Cal. Interval Jun. 03, 07 1 Year NCR NCR NCR NCR NCR NCR Jun. 03, 07 1 Year NCR NCR NCR NCR N/A N/A 2.3. For Radiated Emission Measurement Item Equipment 1. Spectrum Analyzer 2. Test Receiver 3. 4. 5. 6. 7. 8. 9. Bilog Antenna 50 Coaxial Switch Cable Cable Cable Cable Signal Generator Manufacturer ANRITSU Rohde&Schwar z Schwarzbeck Anritsu Corp Schwarzbeck Rosenberger Schwarzbeck Schwarzbeck HP Model No. MS2661C ESC830 Serial No. Last Cal. 6200140915 Jun 01,07 828982/018 Jun 01,07 Cal. Interval 1 Year 1 Year VULB9163 MP59B AK9513 N/A AK9513 AK9513 864A 142 6100237248 ACRX1 FR2RX2 CRRX2 CRRX2 3625U00573 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year Jun 01,07 Jun 01,07 Jun 01,07 Jun 01,07 Jun 01,07 Jun 01,07 Jun 01,07 2.4. For Conducted Emission Test Item 1. 2. 3. 4. 5. 6. Equipment Test Receiver Pulse Limiter L.I.S.N. Conical Voltage Probe Coaxial Switch Manufacturer Rohde & Schwarz Rohde & Schwarz Rohde & Schwarz Emtek Schwarzbeck Anritsu Model No. ESHS30 ESH3-Z2 ESH2-Z5 N/A TK9416 MP59B Serial No. 828985/018 100006 834549/005 N/A N/A 6100214550 Last Cal. Jun. 01, 07 Jun. 01, 07 Jun. 01, 07 N/A Jun. 01.07 Jun. 01, 07 Cal. Interval 1 Year 1 Year 1 Year N/A 1 Year 1 Year Page 5 of 27 Shenzhen BST Technology Co., Ltd. Reprt No. BTRE0804071110 3. POWER LINE CONDUCTED EMISSION TEST 3.1. Block Diagram of Test Setup Telcom Line/AC MAIN L.I.S.N. #1 Test Receiver EUT (EUT: FINGERPRINT ) 3.2. Test Standard EN 55022: 2006 3.3. Power Line Conducted Emission Limit Power Port limits Telecommunication Telecommunication (dBµV) Port Limits (dBµA) Port Limits (dBµV) Quasi-peak Average Quasi-peak Average Quasi-peak Average 0.15MHz ~ 0.5MHz 79 66 53~43* 40~30* 97~87* 84~74* Frequency 0.5MHz ~ 30MHz 73 60 43 30 87 74 * Decreasing linearly with logarithm of the frequency 3.4. EUT Configuration on Test The following equipments are installed on conducted emission test to meet EN55013 requirement and operating in a manner, which tends to maximize its emission characteristics in a normal application. 3.4.1. EUT Model Number Serial Number Manufacturer : R2/M2 : N/A : FINGERTEC WORLDWIDE SDN BHD. 3.5. Operating Condition of EUT 3.5.1. Setup the EUT and simulators as shown in Section 3.1. 3.5.2. Turn on the power of all equipments. 3.5.3. Let the EUT work in test modes (EUT Working) and test it. Page 6 of 27 Shenzhen BST Technology Co., Ltd. Reprt No. BTRE0804071110 3.6. Test Procedure The EUT is put on the ground and connected to the AC mains through a Artificial Mains Network (AMN). This provided 50ohm-coupling impedance for the tested equipments. Both sides of AC line are checked to find out the maximum conducted emission levels according to the EN55022 regulations during conducted emission test. The bandwidth of the test receiver (R&S Test Receiver ESHS30) is set at 10KHz. The frequency range from 150 KHz to 30 MHz is investigated. Page 7 of 27 Shenzhen BST Technology Co., Ltd. Reprt No. BTRE0804071110 3.7. Power Line Conducted Emission Test Results PASS. The frequency range 150KHz to 30MHz is investigated. reported below are too low against the prescribed limit. All the emission levels not Page 8 of 27 Shenzhen BST Technology Co., Ltd. Reprt No. BTRE0804071110 4. RADIATED EMISSION TEST 4.1.1. Block Diagram of Test Setup EUT AC MAINS (EUT: FINGERPRINT ) 4.1.2. Open Site Setup Diagram ANTENNA TOWER ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS 3 METERS EUT TURN TABLE 0.8 METER GROUND PLANE 4.2. Test Standard EN 55022:2006 4.3. Radiated Emission Limit All emanations from a Class B computing devices or system, including any network of conductors and apparatus connected thereto, shall not exceed the level of field strengths specified below: FREQUENCY (MHz) DISTANCE (Meters) 30 ~ 230 230 ~ 1000 3 3 FIELD STRENGTHS LIMITS (dBµV/m) 40 47 Note:(1) The tighter limit shall apply at the edge between two frequency bands. (2) Distance refers to the distance in meters between the measuring instrument antenna and the closed point of any part of the EUT. Page 9 of 27 Shenzhen BST Technology Co., Ltd. Reprt No. BTRE0804071110 4.4. EUT Configuration on Test The EN55022 Class B regulations test method must be used to find the maximum emission during radiated emission test. 4.5. Operating Condition of EUT 4.5.1. Setup the EUT as shown on Section 3.1. 4.5.2. Turn on the power of all equipments. 4.5.3. Let the EUT work in test mode and measure it. 4.6. Test Procedure The EUT is placed on a turn table which is 0.8 meter above ground. The turn table can rotate 360 degrees to determine the position of the maximum emission level. The EUT is set 3 meters away from the receiving antenna which is mounted on a antenna tower. The antenna can move up and down between 1 to 4 meters to find out the maximum emission level. Broadband antenna (calibrated by dipole antenna) are used as a receiving antenna. Both horizontal and vertical polarization of the antenna are set on test. The bandwidth setting on the test receiver (R&S TEST RECEIVER ESCS20) is 120 KHz. The EUT is tested in Anechoic Chamber. All the test results are listed in Section 4.7. and all the scanning waveform are attached within Appendix I. . Page 10 of 27 ShenzhenBST Technology Co., Ltd. Reprt No.BTRE0804071110 4.7. Radiated Emission Test Results PASS. The frequency range from 30MHz to 1000MHz is investigated. following pages. Please see the Page 11 of27 Shenzhen BST Technology Co., Ltd. . Report No.BTRE0804071110 5. ELECTROSTATIC DISCHARGE TEST 5.1.1. Block Diagram of Test Setup EUT AC MAINS (EUT: FINGERPRINT ) 5.1.2. Block Diagram of ESD Test Setup ESD Tester EUT AC Mains 0.8 m AC Mains Remark: is Discharge Electrode 5.2. Test Standard EN 55024:1998+A1:2001+A2: 2003 (EN61000-4-2:1995+A1:1998+A2:2001) Severity Level 3 for Air Discharge at 8KV Severity Level 2 for Contact Discharge at 4KV 5.3. Severity Levels and Performance Criterion 5.3.1. Severity level Level 1. Test Voltage Contact Discharge (KV) 2 Test Voltage Air Discharge (KV) 2 2. 4 4 3. 6 8 4. 8 15 X. Special Special 5.3.2. Performance criterion: B 5.4. EUT Configuration on Test The configuration of EUT are listed in Section 3.4.. Page 12 of 27 Shenzhen BST Technology Co., Ltd. . Report No.BTRE0804071110 5.5. Operating Condition of EUT 5.5.1. Setup the EUT as shown in Section 5.1.. 5.5.2. Turn on the power of all equipments. 5.5.3. Let the EUT work in test mode (off hook) and test it. 5.6. Test Procedure 5.6.1. Air Discharge: This test is done on a non-conductive surfaces. The round discharge tip of the discharge electrode shall be approached as fast as possible to touch the EUT. After each discharge, the discharge electrode shall be removed from the EUT. The generator is then re-triggered for a new single discharge and repeated 10 times for each pre-selected test point. This procedure shall be repeated until all the air discharge completed. 5.6.2. Contact Discharge: All the procedure shall be same as Section 7.6.1. except that the tip of the discharge electrode shall touch the EUT before the discharge switch is operated. 5.6.3. Indirect discharge for horizontal coupling plane At least 20 single discharges shall be applied to the horizontal coupling plane, at points on each side of the EUT. The discharge electrode positions vertically at a distance of 0.1m from the EUT and with the discharge electrode touching the coupling plane. 5.6.4. Indirect discharge for vertical coupling plane At least 20 single discharge shall be applied to the center of one vertical edge of the coupling plane. The coupling plane, of dimensions 0.5m X 0.5m, is placed parallel to, and positioned at a distance of 0.1m from the EUT. Discharges shall be applied to the coupling plane, with this plane in sufficient different positions that the four faces of the EUT are completely illuminated. 5.7. Test Results PASS. Please refer to the following page. Page 13 of 27 Shenzhen BST Technology Co., Ltd. . Report No.BTRE0804071110 Electrostatic Discharge Test Results Shenzhen BST Technology Co., Ltd. 04/08/2008 Applicant : FINGERTEC WORLDWIDE SDN Test Date : Apr.08,2008 BHD EUT : FINGERPRINT Temperature : 22℃ M/N : R2/M2 Humidity : 50% Power Supply : Test Mode : Off Hook Test Engineer : Deng Yong Air Discharge: ±8KV For each point positive 10 times and negative 10 times discharge. Contact Discharge: ±4KV Kind A-Air Discharge C-Contact Discharge Location Result Slots 10 points A PASS Button 20 points A PASS LED 2 points A PASS Enclosure 20 points A PASS Screw 3 points C PASS Ports 2 points C PASS HCP 5 points C PASS VCP 5 points C PASS Discharge should be considered on Contact and Air and Horizontal Coupling Plane (HCP) and Vertical Coupling Plane (VCP). Reviewer: Page 14 of 27 Shenzhen BST Technology Co., Ltd. . Report No.BTRE0804071110 6. RF FIELD STRENGTH SUSCEPTIBILITY TEST 6.1. Block Diagram of Test Setup 6.1.1. Block Diagram of the EUT and the simulators AC MAINS EUT (EUT: FINGERPRINT ) 6.1.2. R/S Test Setup 3 Meters EUT and Simulators System Anechoic Chamber 0.8 Meter Measurement Room Power Amp Signal Generator 6.2. Test Standard EN 55024:1998+A1:2001+A2: 2003 Severity Level 2 at 3V / m (EN61000-4-3:2002) Page 15 of 27 Shenzhen BST Technology Co., Ltd. . Report No.BTRE0804071110 6.3. Severity Levels and Performance Criterion 6.3.1. Severity level Level Field Strength V/m 1. 1 2. 3 3. 10 X. Special 6.3.2. Performance criterion : A 6.4. EUT Configuration on Test The configuration of EUT are listed in Section 3.4.. 6.5. Operating Condition of EUT Setup the EUT as shown in Section 6.1.. The operating condition of EUT are listed in section 3.5. 8.6. Test Procedure The EUT and its simulators are placed on a turn table which is 0.8 meter above the ground. The EUT is set 3 meters away from the transmitting antenna which is mounted on an antenna tower. Both horizontal and vertical polarization of the antenna are set on test. Each of the four sides of EUT must be faced this transmitting antenna and measured individually. In order to judge the EUT performance, a CCD camera is used to monitor the EUT. All the scanning conditions are as follows : Condition of Test ---------------------------------------------1. Fielded Strength 2. Radiated Signal 3. Scanning Frequency 4. Sweeping time of radiated 5. Dwell Time Remarks ---------------------------------3 V/m (Severity Level 2) Modulated 80 - 1000 MHz 0.0015 decade/s 1 Sec. 8.7. Test Results PASS. Please refer to the following page. Page 16 of 27 Shenzhen BST Technology Co., Ltd. . Report No.BTRE0804071110 RF Field Strength Susceptibility Test Results Shenzhen BST Technology Co., Ltd. Date :04/08/2008 Applicant : FINGERTEC WORLDWIDE SDN Test Date : Apr.08,2008 BHD EUT : FINGERPRINT Temperature : 22℃ M/N : R2/M2 Humidity : 50% Power Supply : Test Mode Test Engineer : Deng Yong Frequency Range : Modulation: ; AM … Pulse : Off Hook 80 MHz to 1000 MHz …none 1 KHz 80% Criterion : A Frequency Rang : 80-1000 Steps 1% 1% Horizontal Vertical Front Pass Pass Right Pass Pass Rear Pass Pass Left Pass Pass Reviewer : Page 17 of 27 Shenzhen BST Technology Co., Ltd. . Report No.BTRE0804071110 APPENDIX I Page 18 of 27 Shenzhen BST Technology Co., Ltd. . Att 0 dB dBµV ↑ D1 227 dBµV 100 1 MHz RBW 9 kHz MT 1 ms PREAMP OFF Report No.BTRE0804071110 Marker 1 [T1 ] 40.78 dBµV 170.000000000 kHz 10 MHz 90 1 PK MAXH 2 AV MAXH 80 70 TDF CE022BQP 60 CE022BAV 50 1 40 30 20 10 0 150 kHz Date: 7.APR.2008 30 MHz 16:35:33 Page 19 of 27 Shenzhen BST Technology Co., Ltd. . Att 0 dB dBµV ↑ D1 227 dBµV 100 1 MHz RBW 9 kHz MT 1 ms PREAMP OFF Report No.BTRE0804071110 Marker 1 [T1 ] 36.68 dBµV 174.000000000 kHz 10 MHz 90 1 PK MAXH 2 AV MAXH 80 70 TDF CE022BQP 60 CE022BAV 50 40 1 30 20 10 0 150 kHz Date: 7.APR.2008 30 MHz 16:36:26 Page 20 of 27 Shenzhen BST Technology Co., Ltd. . Report No.BTRE0804071110 APPENDIX II Page 21 of 27 Shenzhen BST Technology Co., Ltd. . Att 0 dB dBµV /m ↑ D1 227 dB* 100 Report No.BTRE0804071110 RBW 120 kHz Marker 1 [T1 ] MT 100 µs 43.25 dBµV/m 250.000000000 MHz PREAMP OFF 100 MHz 1 GHz 90 1 PK MAXH 80 70 TDF 60 50 1 RE55022B 40 30 20 10 0 30 MHz Date: 7.APR.2008 1 GHz 16:26:43 Page 22 of 27 Shenzhen BST Technology Co., Ltd. . Att 0 dB dBµV /m ↑ D1 227 dB* 100 Report No.BTRE0804071110 RBW 120 kHz Marker 1 [T1 ] 38.37 dBµV/m MT 100 µs 335.440000000 MHz PREAMP OFF 100 MHz 1 GHz 90 1 PK MAXH 80 70 TDF 60 50 RE55022B 1 40 30 20 10 0 30 MHz Date: 7.APR.2008 1 GHz 16:28:19 Page 23 of 27 Shenzhen BST Technology Co., Ltd. . Report No.BTRE0804071110 APPENDIX III (Photos of the EUT) Page 24 of 27 Shenzhen BST Technology Co., Ltd. . Report No.BTRE0804071110 Figure 1 General Appearance of EUT Figure 2 General Appearance of EUT Page 25 of 27 Shenzhen BST Technology Co., Ltd. . Report No.BTRE0804071110 Figure 3 Inside of EUT Figure 4 Inside of EUT Page 26 of 27 Shenzhen BST Technology Co., Ltd. . Report No.BTRE0804071110 Figure 5 Test scene Figure 6 Test scene Page 27 of 27