Power Relays Type CS30/CF30 Monostable • • • • • • • • • • • CS30
Compressor control relay Switching capacity 30 A DC coils 6 to 48 VDC AC coils 24 to 277 VAC 2 normally open contacts, 2 change over contacts Reinforced insulation 4 KV / 8 mm Meets class F construction PCB or Fast-on terminal General purpose, power loads Standard as sealed UL, CUL approved
CF30
Product Description Relay high power output. It is sealed designed for
C S30 A 002 12
Ordering Key
vending machines, compressors load.
and
Type Terminal version (S30= Soldering - F30= Fast-on) Coil version (A=AC - D=DC) Contact code Coil rated voltage
Type Selection Contact configuration
Contact rating
Contact code
2 normally open contact
(DPST {2-form A})
30 A
200
2 change over contact
(DPDT {2-form C})
30 A
002
Coil Characteristics, AC (20°C)
Coil Characteristics, DC (20°C) Rated voltage
Pick-up voltage
Drop-out voltage
Coil resistance
Rated voltage
Pick-up voltage
Drop-out voltage
VDC
Max. allowable voltage VDC
VDC
VDC
Ω ±10%
VAC
VAC
6 12 24 48
4.5 9.0 18.0 36.0
0.6 1.2 2.4 4.8
6.6 13.2 26.4 52.8
22 86 350 1390
24 120 240 277
19.2 96.0 192.0 221.6
Coil resistance
VAC
Max. allowable voltage VAC
4.8 24.0 48.0 55.4
26.4 132.0 264. 304.7
39 950 3800 5485
Ω ±10%
Contact Characteristics
UL rating
Contact rating Material Initial contact resistance Current Max. switching current Max. switching power Voltage Max. switching voltage Life Electrical life Mechanical life
8
200 (NO) 30 A -120/277 VAC 2 HP - 250 VAC TV 10 30 A -120/270 VAC Silver alloy 50 mΩ max. (1A-6VDC)
(NO) 20 A - 28 VDC / 227VAC 2 HP - 250 VAC TV 10 20 A - 28 VDC /227 VAC Silver alloy 50 mΩ max. (1A-6VDC)
(NC) 1 HP - 120 VAC 2 HP - 250 VAC TV 10 3 A - 28 VDC/277 VAC Silver alloy 50 mΩ max. (1A-6VDC)
30 A 8.310 VA / 840 W
30 A 8.310 VA / 840 W
30 A 8.310 VA / 840 W
277 VAC
277 VAC
277 VAC
5
1 x 110 ops/min. 6 5 x 10 ops/min.
1 x 110 ops/min. 6 5 x 10 ops/min.
002
5
5
1 x 110 ops/min. 6 5 x 10 ops/min.
Specifications are subject to change without notice
Gross Automation (877) 268-3700 · www.carlogavazzisales.com ·
[email protected]
Power Relays Type CS30/CF30 Monostable
Insulation Test voltage (1 min.) Open contacts Contacts/coil Contact/poles
Surge voltage Contacts/coil Initial insulation resistance at 500 VDC
4000 Vrms 1500 Vrms 2000 Vrms
10000 VAC 1000 MΩ
General Data Nominal coil power Operate time at nom. voltage Release time at nom. voltage Ambient temperature AC DC Vibration resistance
AC version 4 VA DC version 1.7 W 15 ms 10 ms -40 °C to +65 °C -55 °C to +85 °C 1.65 mm p.p. 10 to 55 Hz
Dimensions
Humidity Weight Enclosure
CS30 . 002 .
CF30 . 200 .
CF30 . 002 .
7.85 14.86
4.12
7.85
1.83
5.16
41.1
52.32
CS30 . 200 .
5.16 14.86
1.32
85 °C max. 60 °C max. 100 m/s2 1000 m/s2 35% to 85% , 40 ~ 86 g Dust cover sealed
Wiring Diagram
CS30 . 200/002 . 34.54 16
6.4
Shock resist.
AC DC Malfunction Mechanical
Pin View
CS30 . 200/002 .
1.19
Temperature rise
30.48
1.32
25.4
CF30 . 200/002 .
CF30 . 200/002 .
4.12
7.85
6.35
6.35
59.71 41.1
52.32
14.86
0.8
7.85
34.54 16 4.58
26.42
Ø 1.8
4.7
14.86
3.96
37.72
25.4
Diagrams
0.8
4.7
Approvals
Allowed temperature (°C)
1 Ambient temperature
C U.S.A.
CANADA
The approvals stated are not generally applicable to all relay versions of a particular type.
Coil voltage (V%) Specifications are subject to change without notice
Gross Automation (877) 268-3700 · www.carlogavazzisales.com ·
[email protected]