Preview only show first 10 pages with watermark. For full document please download

Cf/cs Series

   EMBED


Share

Transcript

Power Relays Type CS30/CF30 Monostable • • • • • • • • • • • CS30 Compressor control relay Switching capacity 30 A DC coils 6 to 48 VDC AC coils 24 to 277 VAC 2 normally open contacts, 2 change over contacts Reinforced insulation 4 KV / 8 mm Meets class F construction PCB or Fast-on terminal General purpose, power loads Standard as sealed UL, CUL approved CF30 Product Description Relay high power output. It is sealed designed for C S30 A 002 12 Ordering Key vending machines, compressors load. and Type Terminal version (S30= Soldering - F30= Fast-on) Coil version (A=AC - D=DC) Contact code Coil rated voltage Type Selection Contact configuration Contact rating Contact code 2 normally open contact (DPST {2-form A}) 30 A 200 2 change over contact (DPDT {2-form C}) 30 A 002 Coil Characteristics, AC (20°C) Coil Characteristics, DC (20°C) Rated voltage Pick-up voltage Drop-out voltage Coil resistance Rated voltage Pick-up voltage Drop-out voltage VDC Max. allowable voltage VDC VDC VDC Ω ±10% VAC VAC 6 12 24 48 4.5 9.0 18.0 36.0 0.6 1.2 2.4 4.8 6.6 13.2 26.4 52.8 22 86 350 1390 24 120 240 277 19.2 96.0 192.0 221.6 Coil resistance VAC Max. allowable voltage VAC 4.8 24.0 48.0 55.4 26.4 132.0 264. 304.7 39 950 3800 5485 Ω ±10% Contact Characteristics UL rating Contact rating Material Initial contact resistance Current Max. switching current Max. switching power Voltage Max. switching voltage Life Electrical life Mechanical life 8 200 (NO) 30 A -120/277 VAC 2 HP - 250 VAC TV 10 30 A -120/270 VAC Silver alloy 50 mΩ max. (1A-6VDC) (NO) 20 A - 28 VDC / 227VAC 2 HP - 250 VAC TV 10 20 A - 28 VDC /227 VAC Silver alloy 50 mΩ max. (1A-6VDC) (NC) 1 HP - 120 VAC 2 HP - 250 VAC TV 10 3 A - 28 VDC/277 VAC Silver alloy 50 mΩ max. (1A-6VDC) 30 A 8.310 VA / 840 W 30 A 8.310 VA / 840 W 30 A 8.310 VA / 840 W 277 VAC 277 VAC 277 VAC 5 1 x 110 ops/min. 6 5 x 10 ops/min. 1 x 110 ops/min. 6 5 x 10 ops/min. 002 5 5 1 x 110 ops/min. 6 5 x 10 ops/min. Specifications are subject to change without notice Gross Automation (877) 268-3700 · www.carlogavazzisales.com · [email protected] Power Relays Type CS30/CF30 Monostable Insulation Test voltage (1 min.) Open contacts Contacts/coil Contact/poles Surge voltage Contacts/coil Initial insulation resistance at 500 VDC 4000 Vrms 1500 Vrms 2000 Vrms 10000 VAC 1000 MΩ General Data Nominal coil power Operate time at nom. voltage Release time at nom. voltage Ambient temperature AC DC Vibration resistance AC version 4 VA DC version 1.7 W 15 ms 10 ms -40 °C to +65 °C -55 °C to +85 °C 1.65 mm p.p. 10 to 55 Hz Dimensions Humidity Weight Enclosure CS30 . 002 . CF30 . 200 . CF30 . 002 . 7.85 14.86 4.12 7.85 1.83 5.16 41.1 52.32 CS30 . 200 . 5.16 14.86 1.32 85 °C max. 60 °C max. 100 m/s2 1000 m/s2 35% to 85% , 40 ~ 86 g Dust cover sealed Wiring Diagram CS30 . 200/002 . 34.54 16 6.4 Shock resist. AC DC Malfunction Mechanical Pin View CS30 . 200/002 . 1.19 Temperature rise 30.48 1.32 25.4 CF30 . 200/002 . CF30 . 200/002 . 4.12 7.85 6.35 6.35 59.71 41.1 52.32 14.86 0.8 7.85 34.54 16 4.58 26.42 Ø 1.8 4.7 14.86 3.96 37.72 25.4 Diagrams 0.8 4.7 Approvals Allowed temperature (°C) 1 Ambient temperature C U.S.A. CANADA The approvals stated are not generally applicable to all relay versions of a particular type. Coil voltage (V%) Specifications are subject to change without notice Gross Automation (877) 268-3700 · www.carlogavazzisales.com · [email protected] 9