Preview only show first 10 pages with watermark. For full document please download

新版规格书cg12-100.2 Model (1)

   EMBED


Share

Transcript

CGT12-160X 12V 160Ah(10hr) Gel battery shows some distinctive advantages over flooded battery or AGM battery, such as super thermal stability, high deep discharge capability, good recovery from deep discharge , even if the battery is left discharged for three days, it will recover to 100% of capacity. With the above-mentioned advantages, the gel battery has long service life, specially suitable for motive power applications, such as golf trailer, sruubber, folklift,etc.The deep discharge cycles increased 50% as compared with the AGM battery. Battery Construction Component Positive plate Negative plate Container Cover Safety valve Terminal Raw material Lead dioxide Lead ABS ABS Rubber Copper General Features ● Nanometer SiO 2 and H 2 SO 4 gelled electrolyte technology for efficiency gas recombination of up to 99% and freedom from electrolyte maintenance or water adding. ● Not restricted for air transport-complies with IATA/ICAO Special Provision A67. ● Can be mounted in any orientation. ● Computer designed lead, calcium tin alloy grid for high power density. ● Long service life, float or cyclic applications. ● Maintenance-free operation. ● Low self discharge. ● Case and cover avaiable in both standard and flame restardant ABS. Dimensions and Weight Length(mm / inch) Width(mm / inch) Height(mm / inch) Total Height(mm / inch) Approx. Weight(Kg / lbs) 546 / 21.5 125 / 4.92 317 / 12.5 323 / 12.7 53.5 / 118 Separator PVC Electrolyte Gelled acid Performance Characteristics Nominal Voltage 12V Number of cell 6 Design Life 12 years Nominal Capacity 77oF(25oC) 10 hour rate (16.0A, 10.8V) 160Ah 5 hour rate (26.4A, 10.5V) 132Ah 1 hour rate (104A, 9.6V) 104Ah Internal Resistance 5.0mOhms Fully Charged battery 77oF(25oC) Self-Discharge 2% of capacity declined per month at 20oC(average) Operating Temperature Range Discharge -20~60oC Charge -10~60oC Storage -20~60oC 1000A(5s) Max. Discharge Current 77oF(25oC) Charge Methods: Constant Voltage Charge 77oF(25oC) Cycle use Charge Voltage: 14.28V-14.52V Maximum charging current 20% of the rated capacity -30mV/ oC Temperature compensation Standby use 13.38V-13.68V No charge current limit is required -20mV/ oC Temperature compensation Discharge Constant Current (Amperes at 77oF25oC) End point 10min 15min volts/cell 1.60V 340 280 1.65V 325 270 1.70V 308 259 1.75V 290 247 1.80V 270 234 30min 1h 3h 5h 10h 165 162 158 154 149 104 102 99.8 97.4 95.0 42.6 42.1 41.5 40.8 40.0 27.2 27.0 26.7 26.4 26.0 16.3 16.3 16.2 16.1 16.0 Discharge Constant Power (Watts per cell at 77oF25oC) End point 10min 15min volts/cell 1.60V 520 450 1.65V 496 435 1.70V 470 420 1.75V 443 404 1.80V 415 387 30min 1h 3h 5h 10h 310 305 300 294 286 200 196 191 185 178 80.0 79.2 78.3 77.4 76.2 55.0 54.6 54.2 53.6 53.0 31.0 30.8 30.6 30.4 30.2 (Note)The above characteristics data are average values obtained within three charge/discharge cycles not the mimimum values. page1 of 2 www.vision-batt.com Battery voltage(V) Charged Volume Constant voltage charge characteristic (0.25CA,20 oC) 140 16A 40.8A 26.4A 9.6 340A 120 0.25 100 0.20 80 160A 104A 0.15 60 1 2 3 20 30 5 10 min 60 3 2 5 10 20 20 0.05 0 0 h CHARGE VOLTAGE CHARGING CURRENT 11.0 0 2 4 6 8 10 12 14 16 Charging time (hours) Capacity(%) 7.8 5.2 2.6 15.0 10.0 7.5 5.0 2.5 14.4 9.6 7.2 4.8 2.4 13.8 9.2 6.9 4.6 2.3 60 13.2 8.8 6.6 4.4 2.2 50 -10 0 10 20 30 40 50 70 40 60 0 3 6 9 12 15 18 21 Storage time: months 24 Cycle service life in relation to depth of discharge Life characteristics of standby use Capacity(%) 100 80 Testing conditions: floating voltage: 2.27 to 2.30V/Cell ambient temperature: 20oC(68 oF) 20 0 2 4 6 Life(year) 8 10 12 Number of cycles(cycles) Temperature effects on float life Temperature effects on capacity 2.27V/Cell 10 Capacity (%) Life(years) 15 5 0 10 30 80 Ambient temperature( oC) 0 27 90 10.4 40 20 100 15.6 60 18 110 (V/CELL) (V/6V) (V/4V) 14.0 Self-discharge characteristic Relationship between charging voltage and temperature (V/8V) CHARGED VOLUME 12.0 Discharge time 120 15.0 13.0 0.10 40 (V/12V) 12V 160Ah Charge characteristic curve (%) (XCA) (V) 12.0 0 Voltage O Discharge characteristic (20 C) Current CGT12-160X 20 30 40 50 Temperature( C) o THE INTERNATIONAL CERTIFICATION NETWORK ISO9001:2000 MH25860 G4M19906-9202-E-16 www.vision-batt.com Shenzhen Center Power Tech. Co., Ltd. Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China Tel: (+86-755) 8431 8088 Fax: (+86-755) 8431 8038 E-mail: [email protected] Copy Right Shenzhen Center Power Technology Co., Ltd (Edition 2010-10) Page 2 of 2