Cg2-600 - Valbis Trade Ltd

   EMBED


Share

Transcript

CG2-600 2V 600Ah(10hr) Gel battery shows some distinctive advantages over flooded battery or AGM battery, such as super thermal stability, high deep discharge capability, good recovery from deep discharge , even if the battery is left discharged for three days, it will recover to 100% of capacity. With the above-mentioned advantages, the gel battery has long service life, specially suitable for motive power applications, such as golf trailer, sruubber, folklift,etc.The deep discharge cycles increased 50% as compared with the AGM battery. Battery Construction Component Positive plate Negative plate Container Cover Safety valve Terminal Raw material Lead dioxide Lead ABS ABS Rubber Copper General Features ● Nanometer SiO 2 and H 2 SO 4 gelled electrolyte technology for efficiency gas recombination of up to 99% and freedom from electrolyte maintenance or water adding. ● Not restricted for air transport-complies with IATA/ICAO Special Provision A67. ● UL-recognized component. ● Can be mounted in any orientation. ● Computer designed lead, calcium tin alloy grid for high power density. ● Long service life, float or cyclic applications. ● Maintenance-free operation. ● Low self discharge. ● Case and cover avaiable in both standard and flame restardant ABS. Dimensions and Weight Length(mm / inch) Width(mm / inch) Height(mm / inch) Total Height(mm / inch) Approx. Weight(Kg / lbs) 302 / 11.9 175 / 6.89 330 / 13.0 367 / 14.5 40 / 88.2 * Weight deviation: ± 3% Separator PVC Electrolyte Gelled acid Performance Characteristics Nominal Voltage 2V Number of cell 1 Design Life 20 years Nominal Capacity 77oF(25oC) 10 hour rate (60.0A, 1.80V) 600Ah 5 hour rate (106A, 1.75V) 530Ah 1 hour rate (372A, 1.60V) 372Ah Internal Resistance Fully Charged battery 77oF(25oC) ≤ 0.7mOhms Self-Discharge 2% of capacity declined per month at 20oC(average) Operating Temperature Range Discharge -20~60oC Charge -10~60oC Storage -20~60oC 2200A(5s) Max. Discharge Current 77oF(25oC) Charge Methods: Constant Voltage Charge 77oF(25oC) 2.40-2.45VPC Cycle use Charge Voltage: Maximum charging current 120A -5mV/ oC Temperature compensation 2.20-2.30VPC Standby use -3.3mV/ oC Temperature compensation Discharge Constant Current (Amperes at 77oF25oC) End point volts/cell 1.60V 1.65V 1.70V 1.75V 1.80V 10min 15min 30min 1260 1188 1116 1044 972 1032 960 912 840 768 600 588 576 564 540 1h 3h 5h 10h 20h 372 360 348 336 318 156 152 148 146 140 114 110 108 106 102 63.0 62.4 61.2 60.6 60.0 33.6 33.0 32.4 32.1 31.5 Discharge Constant Power (Watts at 77oF25oC) End point volts/cell 1.60V 1.65V 1.70V 1.75V 1.80V Total height with removeable cover: 367 10min 15min 30min 2157 2053 2000 1904 1804 1750 1736 1663 1559 1475 1123 1073 1023 993 950 1h 3h 5h 10h 20h 696 662 635 613 585 292 277 263 250 235 219 207 197 193 180 122 111 109 105 97.9 66.1 62.3 59.6 57.5 55.4 (Note)The above characteristics data are average values obtained within three charge/discharge cycles not the mimimum values. All data shall be changed without notice,Vision reserves the right to explain and update the information contained hereinto. page1 of 2 www.vision-batt.com CG2-600 O Charging characteristic for Cycle use 2.40 100 0.14 2.20 600A 372A 80 60 40 1.60 0.05 1.40 0 8 12 16 20 24 Self-discharge characteristic 110 (V/CELL) 100 Capacity(%) (V/6V) (V/4V) 4 Charging time (hours) Relationship between charging voltage and temperature (V/8V) 100%(0.1CAx10H) ---- 50%(0.1CAx5H) Charge Charge Voltage(2.45V/Cell) Charge Current 0.1CA o Temperature25 C 1.80 0.08 Discharge time (V/12V) Discharge 2.00 0.11 0.02 20 )Ratio Voltage(V)/PerCell 0.17 ChargeCurrent(CA) 146A 106A 60A 1260A 120 Charged Volume(%) Battery voltage(V) Discharge characteristic (25 C) 2V 600Ah 90 15.6 10.4 7.8 5.2 2.6 15.0 10.0 7.5 5.0 2.5 14.4 9.6 7.2 4.8 2.4 13.8 9.2 6.9 4.6 2.3 60 13.2 8.8 6.6 4.4 2.2 50 -10 0 10 20 30 40 50 80 70 40 60 Ambient temperature( oC) 0 3 6 9 12 15 18 21 Storage time: months 24 27 30 Cycle service life in relation to depth of discharge Capacity(%) Life characteristics of Standby use 50% Depth of discharge Number of cycles(cycles) Life(year) Temperature effects on capacity Capacity (%) Life(years) Temperature effects on float life Temperature( oC) THE INTERNATIONAL CERTIFICATION NETWORK ISO9001:2008 MH25860 G4M19906-9202-E-16 www.vision-batt.com Shenzhen Center Power Tech. Co., Ltd. Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China Tel: (+86-755) 8431 8088 Fax: (+86-755) 8431 8038 E-mail: [email protected] Copy Right Shenzhen Center Power Technology Co., Ltd (Edition 2014-1) Page 2 of 2