TecomTM Series / Data Gathering Panels
TS082x Series
Challenger Data Gathering Panels
Overview
Features
TS082x series of data gathering panels (DGPs) are used to expand the number of inputs and outputs (or relays) on the Challenger system.
•
TS0820/TS0824 - 8 zone inputs
•
TS0827 - 4 zone inputs
•
8-input DGPs can be expanded to 32 inputs
•
8-input DGPs can be used with TS0840, TS0841, or TS0842 expanders to add 8 or 16 relays or outputs
•
DGPs are polled for online state
•
1 siren output (except when used at DGP address 15)
•
Tamper input
DGPs allow installers to easily terminate wiring connections for inputs and relay outputs at locations away from the panel. Up to 15 DGPs can be connected directly to each Challenger control panel over a reliable RS-485 data bus, thereby minimizing cable runs. If a communications failure occurs, the data gathering panel remembers its last alarm, helping to identify possible reasons for faults. The TS0820 and TS0824 includes 8 standard inputs and a siren output. This standard configuration can be expanded to 32 inputs and 16 outputs. The TS0827 is an economy DGP that has similar features but offers only four inputs and no integrated power supply or siren output. No expansion is possible. DGPs and other expansion modules can be mounted in Challenger metal housings.
www.interlogix.com.au
Interlogix
National Sales Enquiries 1300 361 479
TS082x Series
271-273 Wellington Road Mulgrave Vic 3170 T +61 3 9239 1200 F +61 3 9239 1298
Challenger Data Gathering Panels System Block Diagram
Specifications TS0820 AC
TS0824 DC
TS0827 DC
120mA
120mA
45mA
16.8VAC 8 to 32 1
13.8VDC 8 to 32 1
13.8VDC 4 No siren
Maximum outputs
16
16
0
Maximum number per panel
15
15
15
Dynamic battery testing Max. distance from panel (may be extended with LAN isolation interfaces) Data bus monitoring
Yes
Not applicable
Not applicable
1,500 m
1,500 m
1,500 m
Yes
Yes
Yes
PCB size
Size A
Size A
Size B
Enclosure
TS0304
No enclosure
No enclosure
Power supply Current consumption (Add 10mA for each expander fitted) Voltage Inputs Siren output
Environmental Operating temperature
0-500C 0-500C 95% 95% non-condensing non-condensing ACMA C-Tick for Australia and New Zealand
Humidity Regulatory
0-500C 95% non-condensing
Ordering information TS0820 TS0820B TS0824 TS0827
AC DGP board with Plug Pack and TS0304 Enclosure AC DGP, board only DC DGP, board only DC four-input DGP, board only
Specifications subject to change without notice. © 2013 Interlogix. All rights reserved. Interlogix is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation.